TEST REPORT F QC 07 Rev.No.002 Dated: 01.04.2015

M/s. EAST CENTRAL RAILWAY - DHANBAD ( DHANBAD ) Date : 12/08/2021


Size : 1C X 1.33 SQ.MM. INDOOR RAILWAYSIGNALLING CABLE GTP No. :
(RED) Tested By : BHAVESH PARMAR
Type : INDOOR RAILWAY SIGNALLING CABLE Date of Testing : 02/08/2021
Mfg. Date : 31/07/2021 Test Ref. : IRS S : 76-89.
Batch No. : A70418/21-22 Total : 2107 Mtrs.
Sr. No. : UIL/TC/21-22/0970
Description : 1C X 1.33 Sq.mm. multistrand Bare Copper Conductor, PVC Insulated ( Type-A) for rated voltage upto and
including 650 V, Single Core Indoor Railway Signalling Cable.
Test Parameter Obseved Value Required Value
Conductor Diameter 3 x 0.751 3 X 0.75 (+ 0.02 mm & - 0.02 mm)

Overall Dimension 5.06 mm 5.00 mm (+ 0.20 mm & - 0.20 mm)

Ovality (%) 4.50 % 15 % (Max.)

Annealing test (Elongation of Copper) 27.80 % 22.00 % (Min.)

Conductor Resistance (Ohm/Km) 12.47 13.26 (Max.)

Thickness of Insulation Avg. : 1.55 mm, Min. : 1.49 mm Nom. : 1.50 mm & Min. : 1.25 mm

High Voltage Withstood 4 KV for 5 Minutes

Water Immersion Test Withstood To be withstand 8 kV@60 Deg.C. for 5


Minutes

Insulation Resistance (@ 50 Deg.C) Wet IR : 13.14 Wet IR : 5.0 (Min.)


(Mohm-Km)

Tensile Strength of PVC 201.36 150 (Min.)


Insulation(Before ageing)(kg/cm^2)

Tensile Strength of PVC 200.41 150 Min.


Insulation(After ageing)(kg/cm^2)

Elongation of PVC Insulation (Before 209.80 150 (Min.)


ageing) (%)

Elongation of PVC Insulation (after 208.70 150 (Min.)


ageing) (%)

Loss of Mass test of insulation 1.30 2.00 (Max.)


(mg/cm^2)

Shrinkage (%) 1.05 2.00 (Max.)

Spark Test (10 kV) Withstood To be withstand

Specific Gravity (g/cm^3) of insulation 1.36 1.42 (Max.)

Thermal Stability of PVC Insulation 97 80 (Min.)


(Minutes)

TRUSHAL VEKARIYA
Q.C. In-Charge Approved By Date : 12/08/2021

Note : Computer Generated Document, No Signature is required. Page 1 of 2


Ultracab (India) Limited
Sr. No. 262, B/h. Galaxy Bearings Ltd. Shapar (Veraval) - 360 024, Dist. Rajkot
Gujarat (India) Phone : 02827 - 253122 / 23, Fax : 02827 - 252725
Email : info@ultracab.in Web : www.ultracab.in
Customer Care : 1800 313 0323, Email ID : complain@ultracab.in
TEST REPORT F QC 07 Rev.No.002 Dated: 01.04.2015

M/s. EAST CENTRAL RAILWAY - DHANBAD ( DHANBAD ) Date : 12/08/2021


Size : 1C X 1.33 SQ.MM. INDOOR RAILWAYSIGNALLING CABLE GTP No. :
(RED) Tested By : BHAVESH PARMAR
Type : INDOOR RAILWAY SIGNALLING CABLE Date of Testing : 02/08/2021
Mfg. Date : 31/07/2021 Test Ref. : IRS S : 76-89.
Batch No. : A70418/21-22 Total : 2107 Mtrs.
Sr. No. : UIL/TC/21-22/0970
Description : 1C X 1.33 Sq.mm. multistrand Bare Copper Conductor, PVC Insulated ( Type-A) for rated voltage upto and
including 650 V, Single Core Indoor Railway Signalling Cable.
Test Parameter Obseved Value Required Value
Visual inspection OK (All good)

TRUSHAL VEKARIYA
Q.C. In-Charge Approved By Date : 12/08/2021

Note : Computer Generated Document, No Signature is required. Page 2 of 2