You are on page 1of 115

midas Design+

Structural Component Design & Detailing

midas Gen
One Stop Solution for Building
and General Structures

Training
Session 01
Basic RC Modeling,
Design and Consideration
ANALYSIS •DESIGN •REPORT •DRAWINGS •ANALYSIS •DESIGN •REPORT •DRAWINGS
2

Product Overview
Product Overview
Structure Overview
Basic Navigation Keys / Modelling
Load & Boundaries
Analysis & Results
Design
Design + Overview
Design
Drawing
3 Features
Seismic Specific Functionality
• Static Seismic Loads
• Response Spectrum Analysis
• Time History Analysis (Linear & Non-linear)
• Base Isolators and Dampers
• Pushover Analysis
• Fiber Analysis
• Ductile Design: ACI 318

Comprehensive Design
• RC Design: ACI318, Eurocode 2 & 8, BS8110, IS:456 & 13920, CSA-A23.3, GB50010, AIJ-WSD, TWN-USD,
• Steel Design: AISC-ASD & LRFD, AISI-CFSD, Eurocode 3, BS5950, IS:800, CSA-S16, GBJ17 & GB50017, AIJ-ASD,
TWN-ASD & LSD,
• SRC Design: SSRC, JGJ138, CECS28, AIJ-SRC, TWN-SRC
• Footing Design: ACI318, BS8110
• Slab & Wall Design: ACI 318
• Ductile Design (Strong column-weak beam): ACI 318

High-rise Specific Functionality


• 3-D Column Shortening Reflecting change in Modulus, Creep and Shrinkage
• Construction Stage Analysis accounting for change in geometry, supports and loadings
• Building model generation wizard
• Automatic mass conversion
• Material stiffness changes for cracked section

Intuitive User Interface


• Works Tree (Input summary with powerful modeling capabilities)
• Models created and changed with ease
• Floor Loads defined by area and on inclined plane
• Built-in Section property Calculator
• Tekla Structures, Revit Structures & STAAD interfaces
4 Project Applications

▪ Building ▪ Plant Structures ▪ Spatial Structures ▪ Specialty Structures


5

Structure Overview
Product Overview
Structure Overview
Basic Navigation Keys / Modelling
Load & Boundaries
Analysis & Results
Design
Design + Overview
Design
Drawing
6 Plan

RENDERED VIEW
2-STOREY Commercial Building with Roofdeck
ANALYSIS •DESIGN •REPORT •DRAWINGS

ELEVATION (m)
FOOTING -1.80
GF FINISH FLOOR LEVEL 0.00
2F FINISH FLOOR LEVEL 4.00
RD FINISH FLOOR LEVEL 7.60

GROUND FLOOR PLAN


7 Plan

SECOND FLOOR PLAN ROOF DECK PLAN


8 Design Criteria

1. Design Code: NSCP 2015, UBC 1997,ACI318-14 B. Live Load (check NSCP Section 205)
2. Material Properties a. @2F 6.00 kPa
A. Concrete Strength (f’c): 4000 psi b. @Roofdeck 6.00 kPa
B. Reinforcement
a. ≤ 12mmØ Yield Strength (fy): 276 MPa C. Static Seismic Load:
b. ≥ 16mmØ Yield Strength (fy): 414 MPa a. Importance Factor, I: 1.00
c. Modulus of Elasticity 200 Gpa b. Soil Profile Type: Sc
3. Allowable Soil Bearing Capacity: 100 kPa c. Distance from WVF System 10 km
4. Design Loads d. Zone Factor, Z 0.40
A. Dead Load e. Seismic Source Type A
a. Selfweight Z-1 f. Ductility Capacity, R 8.5
b. Concrete slab 150mm 3.54 kPa
c. Walls 10 kN/m 5. Load Combination: ACI318-14, NSCP 2015
d. SIDL @ 2F 2.00 kPa
e. SIDL @ roofdeck 1.80 kPa

(check NSCP Section 204)


9 Design Criteria

PRELIMINARY SECTIONS:
C1 600X600mm
PERSPECTIVE
C2 750X750mm 2B 300X600mm
GB 300X500mm RG1 350X700mm
2G1 400X800mm RG2 350X700mm
2G2 400X800mm RB 300X600mm
10

• Properties
• Material Properties

• Section Properties

• Stiffness Modifier

• Geometry

Basic Navigation Keys


• Frame Wizard

• Building Generation

• Story Data
Product Overview
• Boundary Condition
Structure Overview • Support

Basic Navigation Keys / Modelling • Load


• Static Loads
Load & Boundaries
• Analysis
Analysis & Results • Static Analysis

Design • Results
• Load Combination
Design + Overview
• Reaction/Force/Displacement

Design • Story Drift

• Design
Drawing
• RC Design
11 Graphic User Interface
Ribbon Menu Toolbar

Task Pane

Work Tree

Table Window

Message Window

Command Line Context Status Bar


Menu
12 Basic Controls

For Modified Selection Selected Node/Beam Number For Activation of views


13 Basic Controls
Iso View Front View Top View
Right View
(Ctrl+Shift+I) (Ctrl+Shift+F) (Ctrl+Shift+T
(Ctrl+Shift+R)
)

Shrink (Ctrl+K) Perspective (Ctrl+J) Display a Hidden (Ctrl+H)


Display the modeled elements in perspective 3- Display the model shape reflecting the sectional
proportionally reduced sizes. dimensional view of the model. shapes of elements and their thicknesses as it
would truly appear.
14 Create New File
1. Open Midas Gen

2. Click ‘New’

3. Click ‘icon’

4. Select ‘Save as’

5. Input file name ‘expert01’

6. Click ‘Save’
15 Define Material
Grade 4000psi concrete

1. Click ‘Properties’ 4. Select ‘Concrete’


2. Click ‘Material
Properties’
5. Select
‘Grade C4000’

3. Click ‘Add’ in
Properties tab`

6. Click ‘OK’
16 Define Section
C1 600x600mm

4. Input a section
name.

1. Click ‘Section’ 3. Select ‘Solid


Rectangle’

2. Click ‘Add’
4. Click ‘User’

5. Enter section
size as shown.

6. Click ‘Apply’
17 Define Section
C2 750x750mm

1. Input a section
name.

2. Enter section
size as shown.
Previously added
section properties.

3. Click ‘Apply’
18 Define Section
GB 300x500mm

1. Input a section
name.

2. Enter section
size as shown.
Previously added
section properties.

(Optional) Click
‘Change Offset’

3. Click ‘Apply’
19 Define Section
2G1 400x800mm

1. Input a section
name.

2. Enter section
size as shown.

3. Click ‘Apply’
20 Define Section
2G2 400x800mm

1. Input a section
name.

2. Enter section
size as shown.

3. Click ‘Apply’
21 Define Section
2B 300x600mm

1. Input a section
name.

2. Enter section
size as shown.

3. Click ‘Apply’
22 Define Section
RG1 350x700mm

1. Input a section
name.

2. Enter section
size as shown.

3. Click ‘Apply’
23 Define Section
RG2 350x700mm

1. Input a section
name.

2. Enter section
size as shown.

3. Click ‘Apply’
24 Define Section
RB 300x600mm

1. Input a section
name.

2. Enter section
size as shown.

5. Click ‘Close’

4. Click ‘OK’ 3. Click ‘Apply’


25 Modify Stiffness
1. Click ‘Scale Factor’

2. Select columns
C1 and C2
3. Input Scale Factor

4. Click ’Add/Replace’
26 Modify Stiffness

1. Select ALL
beam sections
2. Input Scale Factor

Previously added
scaled factors for
column.

It can also be viewed in


the ‘Works’ Tree Menu 3. Click ’Add/Replace’

4. Click ’Add/Replace’
27 Modelling
Frame Wizard

1. Click ‘Structure’

2. Select ‘Frame’
28 Modelling
Frame Wizard

1. Input Distance: 7.5


2. Input Repeat: 1

3. Click ‘Add X-Coord.


29 Modelling
Frame Wizard

Previously added
coordinates.
1. Input Distance: 6

2. Input Repeat: 4

3. Click ‘Add X-Coord.


30 Modelling
Frame Wizard

Check last X-
coordinate: 31.5
1. Input Distance: 7.5

2. Input Repeat: 1

3. Click ‘Add Z-Coord.


31 Modelling
Frame Wizard

1. Input Distance: 7

2. Input Repeat: 3
Plotted nodes
through the
coordinates.
3. Click ‘Add Z-Coord.
32 Modelling
Frame Wizard

1. Input Distance: 8.5

2. Input Repeat: 1

3. Click ‘Add Z-Coord.


33 Modelling
Frame Wizard

1. Click ‘Edit’

Check last Z-coordinate: 37


34 Modelling
Frame Wizard

1. Click ‘Generate
frame’

2. Select Material
‘Grade C4000’

3. Select Section
‘GB 300x500’
35 Modelling
Frame Wizard

1. Click ‘Insert’

2. Input Rotation
Check insertion Alpha: -90
point: 0,0,0
Rotation
Alpha =X
Beta =Y
Gamma =Z
The generated
frame is in X-Z
plane. Follow
the steps above
to change it in
X-Y plane.

3. Click ‘Apply’

4. Click ‘Close’
36 Display Option
1. Click ‘Display
Option’ icon

2. Click ‘Draw’

3. Select 4. Click ‘Section/


‘Element Color’ Thickness Color’

5. Click ‘Random
Color’
Repeat Step 5 until you are
satisfied with the color set.

6. Click ‘Apply’

7. Click ‘Apply’
37 Modelling
Main Frame

1. Go to ‘Node/Element’

2. Click ‘Change Parameters’

3. Select ’Element
Local Axis’

4. Input Beta
Angle: 0
38 Modelling
Main Frame

1. Click ‘Select All’ You can choose different


mode of selection then
select all elements.

2. Scroll down

3. Apply
39 Modelling
Main Frame

1. Click ‘Extrude’

2. Select ‘Node
to Line Element’

3. Click ‘Reverse I-J’

4. Select Element
Attribute
40 Modelling
Main Frame

1. Go to ‘Structure’ tab

2. Click ‘Control Data’

3. Click ‘Building Generation’

4. Input:
Number of copies = 1
Distance (Global Z) = 4

5. Click ‘Add’

ELEVATION (m)
FOOTING -1.80
GF FINISH FLOOR LEVEL 0.00
2F FINISH FLOOR LEVEL 4.00
RD FINISH FLOOR LEVEL 7.60
41 Modelling
Main Frame

1. Input:
Number of copies = 1
Distance (Global Z) = 3.6

2. Click ‘Add’

Added floor heights. ELEVATION (m)


FOOTING -1.80
3. Click ‘Apply’. GF FINISH FLOOR LEVEL 0.00
Then ‘Close’ 2F FINISH FLOOR LEVEL 4.00
RD FINISH FLOOR LEVEL 7.60
42 Modelling
Main Frame

2. Click
‘Activate’

1. Right click
Section C1 600x600
from the tree menu.

2. Click ‘Select’ to
select elements by
property.

Option:
You can double click the
section name to select
the elements by property.
43 Modelling
Main Frame

1. Change View
to Front View

2. Use ‘Select
by Window’ 1
3. Create a window
selection from left to
right to select
internal columns.

4. Select Section C2
750x750. Then, drag & drop
to the model area to assign
section in the selected
elements.
2
44 Modelling
Main Frame

3. Use ‘Select 1. Click


by Plane’ ‘Activate All’

2. Change View
4. Click ‘XY 3. Click a node at to Isometric.
Plane’ Roof deck level to
select a Z position.

5. Click ‘Close’
45 Modelling
Main Frame

1. Click ‘Activate’ 2. Change View


to Top View

4. Use ‘Select All’

4. Select Section RG1


350x700. Then, drag & drop
to the model area to assign
section. 3. Change
Selection Filter
to ‘x’
46 Modelling
Main Frame

2. Use ‘Select All’

3. Select Section RG2


350x700. Then, drag & drop
to the model area to assign
section. 1. Change
Selection Filter
to ‘y’
47 Modelling
Intermediate Roof beams

2. Go to ‘Node/Element’ tab

3. Click ‘Create 8. Start creating Intermediate


Elements’ beams through the snap points.

4. Select ‘General/ Tapered Beam

5. Select ‘Grade
C4000’

6. Select Section 1. Set Element


‘RB 300x600’ Snap Control: 3

7. Uncheck
Intersect ‘Element’
48 Modelling
Intermediate Roof beams

2. Click ‘Intersect’

3. Use ‘Select All’

4. Click ‘Apply’

5. Click ‘Close’

1. Change
Selection Filter
to ‘none’
49 Modelling
Intermediate Floor beams

1. Click 2. Change View


‘Activate All’ to Isometric

3. Press ‘Ctrl+ H’. In your


keyboard to change
4. Right click display into wireframe.
Section RB 300x600
from the tree menu.

5. Click ‘Select’ to
select elements by
property.
50 Modelling
Intermediate Floor beams

1. Click ‘Translate’
in Elements tab.
2. Select ‘Copy’

3. Input: dz=-3.6 to
translate beams to
2nd floor framing level

4. Check ‘Intersect
Node & Element.

5. Click ‘Apply’

6. Click ‘Close’
51 Modelling
Intermediate Floor beams

1. Use ‘Select 4. Click ‘Activate’


by Plane’

2. Click ‘XY 3. Click a node at 2nd Floor


Plane’ level to select a Z position.

5. Click ‘Close’
52 Modelling
Intermediate Floor beams

3. Select Section 2B
300x600. Then, drag & drop
to the model area to assign
in the selected beams.

1. Right click
Section RB 300x600
from the tree menu.

2. Click ‘Select’ to
select elements by
property.
53 Modelling
Intermediate Floor beams

2. Press ‘Ctrl+ H’. In your 1. Change View


keyboard to change to Top view
display from wireframe.
3. Use ‘Select by window’
to select the beams at the
floor opening.
4. Create a
2
• window selection
from right to left.
• 1

4•

•3
5. Press ‘delete’.
In your keyboard.
54 Modelling
Main Frame

1
1. Use ‘Select by window’
2
2. Create series of window
selection from left to right to
select main beam elements
parallel to X direction.

3. Select Section 2G1


400x800. Then, drag & drop
to the model area to assign
in the selected beams.
55 Modelling
Main Frame

2. Use ‘Select All’

3. Select Section 2G2


400x800. Then, drag & drop
to the model area to assign
section.
1. Change
Selection Filter
to ‘y’
56 Modelling
Apply beam end release

1. Click 2. Change View


‘Activate All’ to Isometric
4. To do a multiple selection of
sections, Click Section 2B 300x600,
Press ‘Ctrl ‘ in your keyboard then
select Section RB 300x600 3. Press ‘Ctrl+ H’. In your
keyboard to change
4. Right click display into wireframe.
Section RB 300x600
from the tree menu.

5. Click ‘Select’ to
select elements by
property.
57 Modelling
Apply beam end release

1. Go to
‘Boundary’ tab.

2. Click ‘Beam
End Release’

My and Mz will be activated.


Default value = 0. For partial
release consideration, use
value: 0<value<1.

3. Click
‘Pinned-Pinned

4. Click ‘Apply’

5. Click ‘Close’
58 Modelling
Main Frame

Beam End Release is


displayed in the model
area and in tree menu.
59 Modelling
Define Story

1. Go to ‘Structure’ tab

2. Click ‘Control Data’

3. Click ‘Story’

Use default ground level = 0 since Click ‘…’ to launch


the modeled structure considers ‘Building Control’. Check
the ground beams are in same for details to consider
level with the finish ground level. before clicking ‘OK’
60 Modelling
Define Story

2. Select ‘1F’

3. Click ‘<-’ to remove it


from selection of story data.

1. Click ‘Auto generate…

4. Click ‘OK’
61 Modelling
Define Story

Defined Story data. Click the drop-down button


to choose if Floor Diaphragm
will be considered or not.
Default = Considered.

1. Select ‘Do not consider’


for Story 1F.

2. Click ‘Close’
62

• Properties
• Material Properties

• Section Properties

• Stiffness Modifier

• Geometry

Load & Boundaries


• Frame Wizard

• Building Generation

• Story Data
Product Overview
• Boundary Condition
Structure Overview • Support

Basic Navigation Keys / Modelling • Load


• Static Loads
Load & Boundaries
• Analysis
Analysis & Results • Static Analysis

Design • Results
• Load Combination
Design + Overview
• Reaction/Force/Displacement

Design • Story Drift

• Design
Drawing
• RC Design
63 Boundary
Panel Zone Effects

1. Click ‘Structure Type’

2. Check:
‘Align Top of Beam Section….’
‘Align Top of Slab (Plate) Section….’

1. Click ‘OK’
64 Boundary
Panel Zone Effects

1. Go to ‘Boundary’ tab.

2. Select as shown:
Click ‘Auto Calculate Panel
Zone Offset Distances.
Click ‘Offset Position’

3. Click ‘OK’
65 Boundary
Panel Zone Effects

ORIGINAL GEOMETRY

AFTER APPLICATION OF
PANEL ZONE EFFECTS

•Top of beam will be moved at the floor level. New


CG of beam will be considered in the analysis.

•Length of beam to be designed will be the clear


distance measured from the face of column
66 Boundary
Define Support

1. Change View
to Isometric
2. Click ‘Define Supports’

3. Click ‘D-All’ 4. Select nodes at the bottom


to assign the defined support.
1
2

5. Click ‘Apply’. Then, click ‘Close’


67 Loads
Static Load Cases

1. Go to ‘Load’ tab.

3. Click ‘Static
Load Cases’
2. Click
‘Static Loads’ 4. Input: Name = DL
5. Select ‘Dead Load (D)’

6. Click ‘Add’

7. Repeat Step 4 to add the other Load Cases


Name Type
1. DL Dead Load (D)
2. LL Live Load (L)
3. EX Earthquake (E)
4. EY Earthquake (E)

8. Click ‘Close’
68 Loads
Convert Selfweight into Masses

1. Go to ‘Structure’ tab.

2. Click
‘Structure Type’

3. Click ‘Convert Self-


weight into Masses’

4. Click ‘Convert to X,Y’

Previously defined
4. Click ‘OK’ Supports
69 Loads
Static Load Cases

1. Go to ‘Load’ tab.

2. Click
3. Click ‘Loads
‘Static Loads’
to masses’

4. Select ‘X,Y’

5. Select ‘DL’ If you want to consider the Load


Factor of Liveload to Static
6. Input Scale
Factor: 1
Seismic, repeat steps 5-7.

7. Click ‘Add’

8. Click ‘OK’
70 Loads
DL Selfweight

1. Click ‘Selfweight’

2. Input Z: ‘-1’

3. Click ‘Add’

4. Click ‘Close’
71 Loads
DL Element Load

1. Use ‘Select 4. Click


by Plane’ ‘Activate’

2. Click ‘XY 3. Click a node at 2nd


Plane’ floor and ground level
to select Z positions.

5. Click ‘Close’
72 Modelling
DL Element Load

2. Click ‘Element’ 1. Change View


Beam Load to Top View

1
3. Use ‘Select by window’
2

5. Select Load
Case Name: DL 4. Create series of window
selection from left to right to
6. Select select external beam elements
‘Uniform Loads’

7. Direction:
‘Global Z’

8. Select ‘Relative’ Value


Input:
X1 = 0
X2 = 0
W = -10

9. Click ‘Apply’.
Then, ‘Close’.
73 Loads
Floor Load

1. Click button

2. Click ‘Define
Floor Load Type’

3. Input Name: ‘2F’

4. Input: DL + LL Store

5. Input:
Load Case Floor Load
1. DL -5.54 (slab weight + SIDL)
2. LL -6
NOTE: Values can locate in NSCP 2015 Chapter 2, Section 204
and 205

6. Click ‘Add’
74 Loads
Floor Load

1. Input Name: ‘Roofdeck’

2. Input: DL + LL Roofdeck

3. Input:
Load Case Floor Load
1. DL -5.34 (slab weight + SIDL)
2. LL -6
NOTE: Values can locate in NSCP 2015 Chapter 2, Section 204
and 205

4. Click ‘Add’

5. Click ‘Close’
75 Loads
Floor Load

2. Use ‘Select 6. Click


1. Change View
by Plane’ ‘Activate’
to Isometric

3. Click ‘XY 4. Click a node at


Plane’ 2nd floor level to
select a Z position.

5. Click ‘Close’
76 Loads
Floor Load

2. Click button 1. Change View


to Top View

3. Click ‘Assign
Floor Loads’
4. Select Floor Load
Type: ‘2F’
Distribution: ‘Two way’

Do a selection avoiding this


area since it is an open floor.
9 8 5
1 4

5. Click this area to 6. Select the nodes from


start selecting nodes. marking 1 to 9 respectively
7 6
to form a closed figure.

2 3

2
77 Loads
Floor Load

9 8
1. Select the nodes from 1
marking 1 to 9 respectively
to assign load to the rest of
the floor area. 6 7 Do a selection avoiding
this area since it is an
open floor.
5 4

2 3

3
2. Click this area to
start selecting nodes.

2
78 Loads
Floor Load

2. Change View
to Isometric

1. Click ‘Activate All’


79 Loads
Floor Load

1. Use ‘Select 4. Click


by Plane’ ‘Activate’

2. Click ‘XY 3. Click a node at


Plane’ roof level to select
a Z position.

5. Click ‘Close’
80 Loads
Floor Load

1. Click button

2. Click ‘Assign
Floor Loads’

3. Select Floor Load


5
Type: ‘Roofdeck’ 1 4
Distribution: ‘Two way’
5. Select the nodes from
marking 1 to 5 respectively
to form a closed figure.

4. Click this area to


start selecting nodes.

2 3
6. Click ‘Close’
81 Loads
Static Seismic Load

3. Input:
1. Click ‘Seismic Loads’
Load Case Name = EX
Seismic Load Code = UBC(1997)
2. Click ‘Add’

4. Input:
Soil Profile Type = Sc
Seismic Zone Factor = 4(0.40)
Seismic Source Type = A
Distance to Seismic Source =
10km
Importance Factor = 1.0

Note: Values are from NSCP


2015 Chapter 2, Section 208
82 Loads
Static Seismic Load

1. Click ‘Period
2. Select ‘2. T = 0.030Hn(^3/4)’ Calculator…’

4. Input: R = 8.5

3. Click ‘OK’
83 Loads
Static Seismic Load

1. Input:
X-Direction = 1
Y-Direction = 0

2. Select ‘None’

3. Click ‘Apply’
84 Loads
Static Seismic Load

1. Select Load
Case Name = EY

2. Input:
4. Click ‘Close’ X-Direction = 0
Y-Direction = 1

3. Click ‘OK’
85

• Properties
• Material Properties

• Section Properties

• Stiffness Modifier

• Geometry

Analysis & Design


• Frame Wizard

• Building Generation

• Story Data
Product Overview
• Boundary Condition
Structure Overview • Support

Basic Navigation Keys / Modelling • Load


• Static Loads
Load & Boundaries
• Analysis
Analysis & Results • Static Analysis

Design • Results
• Load Combination
Design + Overview
• Reaction/Force/Displacement

Design • Story Drift

• Design
Drawing
• RC Design
86 Analysis
Perform Analysis

1. Go to ‘Analysis’ tab

2. Click ‘Perform
Analysis’
87 Results
Load Combination

1. Go to ‘Results’ tab

2. Click ‘Load
Combination’ 5. Select ‘ACI318-14’

3. Click ‘Concrete
Design’

4. Click ‘Auto
Generation…’
88 Results
Load Combination

2. Click ‘Set Cases..’

1. Check ‘Consider
Orthogonal Effect’

3. Select
Load Case 1: EX(ST)
Load Case 2: EY(ST)

4. Click ‘Add’

5. Click ‘OK’

6. Click ‘OK’
89 Results
Load Combination

Displays the auto generated


load combinations.
90 Results
Reactions

1. Click ‘Reactions’

2. Select ‘Reaction
Forces/Moments’

3. Set-up your desired


display results

4. Click ‘Apply’
91 Results
Deformations

1. Click ‘Deformations’

2. Select ‘Deformed Shape’

3. Set-up your desired


display results.

4. Click ‘Apply’
92 Results
Displacement

1. Select ‘Displacement Contour’

2. Set-up your desired


display results.

3. Click ‘Apply’
93 Results
Forces

1. Click ‘Forces’

2. Select ‘Beam Diagrams’

3. Set-up your desired


display results

4. Click ‘Apply’
94 Results
Story Drift

1. Click ‘Results Table’

2. Click ‘Story’

3. Select ‘Story Drift’


95 Results
Drift Check

1. Select these
Load Cases.

2. Click ‘OK’
96 Results
Drift Check

1. Cd = 0.7R = 0.7x8.5
(refer to note below)
2. Importance Factor: 1

3. Input Allowable Note: From NSCP 2015


Ratio: 0.025
Eq. 208-21
ΔM = 0.7RΔs

Section 208.6.5.1
Calculated storey drift using ΔM shall
not exceed 0.025 times the storey height
for the structures having a fundamental
period less than 0.7 sec. For structures
4. Click ‘OK’ having a fundamental period of 0.7 sec.
or greater, the calculated storey drift shall
not exceed 0.020 times the storey height.
97 Results
Drift Check

2. Check the results

1. Select results
98

• Properties
• Material Properties

• Section Properties

• Stiffness Modifier

• Geometry

Design
• Frame Wizard

• Building Generation

• Story Data
Product Overview
• Boundary Condition
Structure Overview • Support

Basic Navigation Keys / Modelling • Load


• Static Loads
Load & Boundaries
• Analysis
Analysis & Results • Static Analysis

Design • Results
• Load Combination
Design + Overview
• Reaction/Force/Displacement

Design • Story Drift

• Design
Drawing
• RC Design
99 Design
RC Design

1. Go to ‘Design’ tab
2. Click ‘RC Design’

3. Select Design
Code: ACI318M-14

4. Check Beam
Deflection

5. Click ‘OK’
10
0 Design
RC Design

1. Click ‘RC Design’


2. Select ‘Modify
Concrete Material’

3. Select ‘Grade C4000’

4. Select
‘ASTM(RC)’

5. Select:
Main Rebar = Grade 60
Sub-Rebar = Grade 40 6. Click ‘Modify’
then ‘Close’
101 Design
Rebar Parameters

1. Click ‘RC Design’


3. Input:
Main Rebar = 20mm
Stirrups = 10mm
Side Bar = 12mm
Arrangement = 3
dT = dB = 0 (Value is
Zero if you want to auto-
calculate the dT and dB
Doubly Rebar = No
2. Select ‘Design
Criteria for Rebar’ 4. Input:
Main Rebar = 20mm
Ties = 10mm
Arrangement Y = 6
Arrangement Z = 6
do = 0 (Value is Zero if
you want to auto-
calculate the dT and dB

5. Click ‘OK’
102 Design
Member Assignment

1. Click ‘General
Design Parameter’

2. Click ‘Member
Assignment’
103 Design
Member Assignment

3. Click ‘Select All’

1. Click ‘Allow Single


Element Member’

2. Select ‘Automatic’

4. Click ‘Apply’
then, ‘Close’
104 Design
Batch Design

1. Click ‘Perform Batch Design’

2. Select ‘Analysis’

3. Select ‘Concrete Beam


Design’ and ‘Concrete
Column Design’

4. Click ‘Run’
105 Design
Design Result

1. Click button to
view the table summary
106 Design
Beam Design Result
107 Design
Beam Design Result

2. Results can be sorted


by Member or by Property

1. Check summary

3. Results can also be sorted by All,


OK (Passed Sections), or NG (No
Good or Failed Sections)

4. You can also Copy the


Table and Paste it to Excel
108 Design
Beam Design Result

1. Select Any Section

2. Click whether you want to view the:


•‘Graphic…’ = Graphical Display
•‘Detail…’ =Detailed Calculation
(Must be sorted by Member)
•‘Summary’ = Summary of Calculation
109 Design
Beam Design Result - Graphic
110 Design
Beam Design Result - Detailed
111 Design
Beam Design Result - Detailed
112 Design
Column Design Result - Graphic

Draw P-M Curve

Graphic
113 Design
Column Design Result - Detailed
114 Design
Column Design Result - Detailed
THANK YOU!
Midas IT Philippines

For more info, contact us on:


FB: Midas IT Philippines
Email: phinquiry@midasit.com / philippines@midasit.com

115

You might also like