Professional Documents
Culture Documents
Midas Expert Training 01 Midas Gen PDF
Midas Expert Training 01 Midas Gen PDF
midas Gen
One Stop Solution for Building
and General Structures
Training
Session 01
Basic RC Modeling,
Design and Consideration
ANALYSIS •DESIGN •REPORT •DRAWINGS •ANALYSIS •DESIGN •REPORT •DRAWINGS
2
Product Overview
Product Overview
Structure Overview
Basic Navigation Keys / Modelling
Load & Boundaries
Analysis & Results
Design
Design + Overview
Design
Drawing
3 Features
Seismic Specific Functionality
• Static Seismic Loads
• Response Spectrum Analysis
• Time History Analysis (Linear & Non-linear)
• Base Isolators and Dampers
• Pushover Analysis
• Fiber Analysis
• Ductile Design: ACI 318
Comprehensive Design
• RC Design: ACI318, Eurocode 2 & 8, BS8110, IS:456 & 13920, CSA-A23.3, GB50010, AIJ-WSD, TWN-USD,
• Steel Design: AISC-ASD & LRFD, AISI-CFSD, Eurocode 3, BS5950, IS:800, CSA-S16, GBJ17 & GB50017, AIJ-ASD,
TWN-ASD & LSD,
• SRC Design: SSRC, JGJ138, CECS28, AIJ-SRC, TWN-SRC
• Footing Design: ACI318, BS8110
• Slab & Wall Design: ACI 318
• Ductile Design (Strong column-weak beam): ACI 318
Structure Overview
Product Overview
Structure Overview
Basic Navigation Keys / Modelling
Load & Boundaries
Analysis & Results
Design
Design + Overview
Design
Drawing
6 Plan
RENDERED VIEW
2-STOREY Commercial Building with Roofdeck
ANALYSIS •DESIGN •REPORT •DRAWINGS
ELEVATION (m)
FOOTING -1.80
GF FINISH FLOOR LEVEL 0.00
2F FINISH FLOOR LEVEL 4.00
RD FINISH FLOOR LEVEL 7.60
1. Design Code: NSCP 2015, UBC 1997,ACI318-14 B. Live Load (check NSCP Section 205)
2. Material Properties a. @2F 6.00 kPa
A. Concrete Strength (f’c): 4000 psi b. @Roofdeck 6.00 kPa
B. Reinforcement
a. ≤ 12mmØ Yield Strength (fy): 276 MPa C. Static Seismic Load:
b. ≥ 16mmØ Yield Strength (fy): 414 MPa a. Importance Factor, I: 1.00
c. Modulus of Elasticity 200 Gpa b. Soil Profile Type: Sc
3. Allowable Soil Bearing Capacity: 100 kPa c. Distance from WVF System 10 km
4. Design Loads d. Zone Factor, Z 0.40
A. Dead Load e. Seismic Source Type A
a. Selfweight Z-1 f. Ductility Capacity, R 8.5
b. Concrete slab 150mm 3.54 kPa
c. Walls 10 kN/m 5. Load Combination: ACI318-14, NSCP 2015
d. SIDL @ 2F 2.00 kPa
e. SIDL @ roofdeck 1.80 kPa
PRELIMINARY SECTIONS:
C1 600X600mm
PERSPECTIVE
C2 750X750mm 2B 300X600mm
GB 300X500mm RG1 350X700mm
2G1 400X800mm RG2 350X700mm
2G2 400X800mm RB 300X600mm
10
• Properties
• Material Properties
• Section Properties
• Stiffness Modifier
• Geometry
• Building Generation
• Story Data
Product Overview
• Boundary Condition
Structure Overview • Support
Design • Results
• Load Combination
Design + Overview
• Reaction/Force/Displacement
• Design
Drawing
• RC Design
11 Graphic User Interface
Ribbon Menu Toolbar
Task Pane
Work Tree
Table Window
Message Window
2. Click ‘New’
3. Click ‘icon’
6. Click ‘Save’
15 Define Material
Grade 4000psi concrete
3. Click ‘Add’ in
Properties tab`
6. Click ‘OK’
16 Define Section
C1 600x600mm
4. Input a section
name.
2. Click ‘Add’
4. Click ‘User’
5. Enter section
size as shown.
6. Click ‘Apply’
17 Define Section
C2 750x750mm
1. Input a section
name.
2. Enter section
size as shown.
Previously added
section properties.
3. Click ‘Apply’
18 Define Section
GB 300x500mm
1. Input a section
name.
2. Enter section
size as shown.
Previously added
section properties.
(Optional) Click
‘Change Offset’
3. Click ‘Apply’
19 Define Section
2G1 400x800mm
1. Input a section
name.
2. Enter section
size as shown.
3. Click ‘Apply’
20 Define Section
2G2 400x800mm
1. Input a section
name.
2. Enter section
size as shown.
3. Click ‘Apply’
21 Define Section
2B 300x600mm
1. Input a section
name.
2. Enter section
size as shown.
3. Click ‘Apply’
22 Define Section
RG1 350x700mm
1. Input a section
name.
2. Enter section
size as shown.
3. Click ‘Apply’
23 Define Section
RG2 350x700mm
1. Input a section
name.
2. Enter section
size as shown.
3. Click ‘Apply’
24 Define Section
RB 300x600mm
1. Input a section
name.
2. Enter section
size as shown.
5. Click ‘Close’
2. Select columns
C1 and C2
3. Input Scale Factor
4. Click ’Add/Replace’
26 Modify Stiffness
1. Select ALL
beam sections
2. Input Scale Factor
Previously added
scaled factors for
column.
4. Click ’Add/Replace’
27 Modelling
Frame Wizard
1. Click ‘Structure’
2. Select ‘Frame’
28 Modelling
Frame Wizard
Previously added
coordinates.
1. Input Distance: 6
2. Input Repeat: 4
Check last X-
coordinate: 31.5
1. Input Distance: 7.5
2. Input Repeat: 1
1. Input Distance: 7
2. Input Repeat: 3
Plotted nodes
through the
coordinates.
3. Click ‘Add Z-Coord.
32 Modelling
Frame Wizard
2. Input Repeat: 1
1. Click ‘Edit’
1. Click ‘Generate
frame’
2. Select Material
‘Grade C4000’
3. Select Section
‘GB 300x500’
35 Modelling
Frame Wizard
1. Click ‘Insert’
2. Input Rotation
Check insertion Alpha: -90
point: 0,0,0
Rotation
Alpha =X
Beta =Y
Gamma =Z
The generated
frame is in X-Z
plane. Follow
the steps above
to change it in
X-Y plane.
3. Click ‘Apply’
4. Click ‘Close’
36 Display Option
1. Click ‘Display
Option’ icon
2. Click ‘Draw’
5. Click ‘Random
Color’
Repeat Step 5 until you are
satisfied with the color set.
6. Click ‘Apply’
7. Click ‘Apply’
37 Modelling
Main Frame
1. Go to ‘Node/Element’
3. Select ’Element
Local Axis’
4. Input Beta
Angle: 0
38 Modelling
Main Frame
2. Scroll down
3. Apply
39 Modelling
Main Frame
1. Click ‘Extrude’
2. Select ‘Node
to Line Element’
4. Select Element
Attribute
40 Modelling
Main Frame
1. Go to ‘Structure’ tab
4. Input:
Number of copies = 1
Distance (Global Z) = 4
5. Click ‘Add’
ELEVATION (m)
FOOTING -1.80
GF FINISH FLOOR LEVEL 0.00
2F FINISH FLOOR LEVEL 4.00
RD FINISH FLOOR LEVEL 7.60
41 Modelling
Main Frame
1. Input:
Number of copies = 1
Distance (Global Z) = 3.6
2. Click ‘Add’
2. Click
‘Activate’
1. Right click
Section C1 600x600
from the tree menu.
2. Click ‘Select’ to
select elements by
property.
Option:
You can double click the
section name to select
the elements by property.
43 Modelling
Main Frame
1. Change View
to Front View
2. Use ‘Select
by Window’ 1
3. Create a window
selection from left to
right to select
internal columns.
4. Select Section C2
750x750. Then, drag & drop
to the model area to assign
section in the selected
elements.
2
44 Modelling
Main Frame
2. Change View
4. Click ‘XY 3. Click a node at to Isometric.
Plane’ Roof deck level to
select a Z position.
5. Click ‘Close’
45 Modelling
Main Frame
2. Go to ‘Node/Element’ tab
5. Select ‘Grade
C4000’
7. Uncheck
Intersect ‘Element’
48 Modelling
Intermediate Roof beams
2. Click ‘Intersect’
4. Click ‘Apply’
5. Click ‘Close’
1. Change
Selection Filter
to ‘none’
49 Modelling
Intermediate Floor beams
5. Click ‘Select’ to
select elements by
property.
50 Modelling
Intermediate Floor beams
1. Click ‘Translate’
in Elements tab.
2. Select ‘Copy’
3. Input: dz=-3.6 to
translate beams to
2nd floor framing level
4. Check ‘Intersect
Node & Element.
5. Click ‘Apply’
6. Click ‘Close’
51 Modelling
Intermediate Floor beams
5. Click ‘Close’
52 Modelling
Intermediate Floor beams
3. Select Section 2B
300x600. Then, drag & drop
to the model area to assign
in the selected beams.
1. Right click
Section RB 300x600
from the tree menu.
2. Click ‘Select’ to
select elements by
property.
53 Modelling
Intermediate Floor beams
4•
•3
5. Press ‘delete’.
In your keyboard.
54 Modelling
Main Frame
1
1. Use ‘Select by window’
2
2. Create series of window
selection from left to right to
select main beam elements
parallel to X direction.
5. Click ‘Select’ to
select elements by
property.
57 Modelling
Apply beam end release
1. Go to
‘Boundary’ tab.
2. Click ‘Beam
End Release’
3. Click
‘Pinned-Pinned
4. Click ‘Apply’
5. Click ‘Close’
58 Modelling
Main Frame
1. Go to ‘Structure’ tab
3. Click ‘Story’
2. Select ‘1F’
4. Click ‘OK’
61 Modelling
Define Story
2. Click ‘Close’
62
• Properties
• Material Properties
• Section Properties
• Stiffness Modifier
• Geometry
• Building Generation
• Story Data
Product Overview
• Boundary Condition
Structure Overview • Support
Design • Results
• Load Combination
Design + Overview
• Reaction/Force/Displacement
• Design
Drawing
• RC Design
63 Boundary
Panel Zone Effects
2. Check:
‘Align Top of Beam Section….’
‘Align Top of Slab (Plate) Section….’
1. Click ‘OK’
64 Boundary
Panel Zone Effects
1. Go to ‘Boundary’ tab.
2. Select as shown:
Click ‘Auto Calculate Panel
Zone Offset Distances.
Click ‘Offset Position’
3. Click ‘OK’
65 Boundary
Panel Zone Effects
ORIGINAL GEOMETRY
AFTER APPLICATION OF
PANEL ZONE EFFECTS
1. Change View
to Isometric
2. Click ‘Define Supports’
1. Go to ‘Load’ tab.
3. Click ‘Static
Load Cases’
2. Click
‘Static Loads’ 4. Input: Name = DL
5. Select ‘Dead Load (D)’
6. Click ‘Add’
8. Click ‘Close’
68 Loads
Convert Selfweight into Masses
1. Go to ‘Structure’ tab.
2. Click
‘Structure Type’
Previously defined
4. Click ‘OK’ Supports
69 Loads
Static Load Cases
1. Go to ‘Load’ tab.
2. Click
3. Click ‘Loads
‘Static Loads’
to masses’
4. Select ‘X,Y’
7. Click ‘Add’
8. Click ‘OK’
70 Loads
DL Selfweight
1. Click ‘Selfweight’
2. Input Z: ‘-1’
3. Click ‘Add’
4. Click ‘Close’
71 Loads
DL Element Load
5. Click ‘Close’
72 Modelling
DL Element Load
1
3. Use ‘Select by window’
2
5. Select Load
Case Name: DL 4. Create series of window
selection from left to right to
6. Select select external beam elements
‘Uniform Loads’
7. Direction:
‘Global Z’
9. Click ‘Apply’.
Then, ‘Close’.
73 Loads
Floor Load
1. Click button
2. Click ‘Define
Floor Load Type’
4. Input: DL + LL Store
5. Input:
Load Case Floor Load
1. DL -5.54 (slab weight + SIDL)
2. LL -6
NOTE: Values can locate in NSCP 2015 Chapter 2, Section 204
and 205
6. Click ‘Add’
74 Loads
Floor Load
2. Input: DL + LL Roofdeck
3. Input:
Load Case Floor Load
1. DL -5.34 (slab weight + SIDL)
2. LL -6
NOTE: Values can locate in NSCP 2015 Chapter 2, Section 204
and 205
4. Click ‘Add’
5. Click ‘Close’
75 Loads
Floor Load
5. Click ‘Close’
76 Loads
Floor Load
3. Click ‘Assign
Floor Loads’
4. Select Floor Load
Type: ‘2F’
Distribution: ‘Two way’
2 3
2
77 Loads
Floor Load
9 8
1. Select the nodes from 1
marking 1 to 9 respectively
to assign load to the rest of
the floor area. 6 7 Do a selection avoiding
this area since it is an
open floor.
5 4
2 3
3
2. Click this area to
start selecting nodes.
2
78 Loads
Floor Load
2. Change View
to Isometric
5. Click ‘Close’
80 Loads
Floor Load
1. Click button
2. Click ‘Assign
Floor Loads’
2 3
6. Click ‘Close’
81 Loads
Static Seismic Load
3. Input:
1. Click ‘Seismic Loads’
Load Case Name = EX
Seismic Load Code = UBC(1997)
2. Click ‘Add’
4. Input:
Soil Profile Type = Sc
Seismic Zone Factor = 4(0.40)
Seismic Source Type = A
Distance to Seismic Source =
10km
Importance Factor = 1.0
1. Click ‘Period
2. Select ‘2. T = 0.030Hn(^3/4)’ Calculator…’
4. Input: R = 8.5
3. Click ‘OK’
83 Loads
Static Seismic Load
1. Input:
X-Direction = 1
Y-Direction = 0
2. Select ‘None’
3. Click ‘Apply’
84 Loads
Static Seismic Load
1. Select Load
Case Name = EY
2. Input:
4. Click ‘Close’ X-Direction = 0
Y-Direction = 1
3. Click ‘OK’
85
• Properties
• Material Properties
• Section Properties
• Stiffness Modifier
• Geometry
• Building Generation
• Story Data
Product Overview
• Boundary Condition
Structure Overview • Support
Design • Results
• Load Combination
Design + Overview
• Reaction/Force/Displacement
• Design
Drawing
• RC Design
86 Analysis
Perform Analysis
1. Go to ‘Analysis’ tab
2. Click ‘Perform
Analysis’
87 Results
Load Combination
1. Go to ‘Results’ tab
2. Click ‘Load
Combination’ 5. Select ‘ACI318-14’
3. Click ‘Concrete
Design’
4. Click ‘Auto
Generation…’
88 Results
Load Combination
1. Check ‘Consider
Orthogonal Effect’
3. Select
Load Case 1: EX(ST)
Load Case 2: EY(ST)
4. Click ‘Add’
5. Click ‘OK’
6. Click ‘OK’
89 Results
Load Combination
1. Click ‘Reactions’
2. Select ‘Reaction
Forces/Moments’
4. Click ‘Apply’
91 Results
Deformations
1. Click ‘Deformations’
4. Click ‘Apply’
92 Results
Displacement
3. Click ‘Apply’
93 Results
Forces
1. Click ‘Forces’
4. Click ‘Apply’
94 Results
Story Drift
2. Click ‘Story’
1. Select these
Load Cases.
2. Click ‘OK’
96 Results
Drift Check
1. Cd = 0.7R = 0.7x8.5
(refer to note below)
2. Importance Factor: 1
Section 208.6.5.1
Calculated storey drift using ΔM shall
not exceed 0.025 times the storey height
for the structures having a fundamental
period less than 0.7 sec. For structures
4. Click ‘OK’ having a fundamental period of 0.7 sec.
or greater, the calculated storey drift shall
not exceed 0.020 times the storey height.
97 Results
Drift Check
1. Select results
98
• Properties
• Material Properties
• Section Properties
• Stiffness Modifier
• Geometry
Design
• Frame Wizard
• Building Generation
• Story Data
Product Overview
• Boundary Condition
Structure Overview • Support
Design • Results
• Load Combination
Design + Overview
• Reaction/Force/Displacement
• Design
Drawing
• RC Design
99 Design
RC Design
1. Go to ‘Design’ tab
2. Click ‘RC Design’
3. Select Design
Code: ACI318M-14
4. Check Beam
Deflection
5. Click ‘OK’
10
0 Design
RC Design
4. Select
‘ASTM(RC)’
5. Select:
Main Rebar = Grade 60
Sub-Rebar = Grade 40 6. Click ‘Modify’
then ‘Close’
101 Design
Rebar Parameters
5. Click ‘OK’
102 Design
Member Assignment
1. Click ‘General
Design Parameter’
2. Click ‘Member
Assignment’
103 Design
Member Assignment
2. Select ‘Automatic’
4. Click ‘Apply’
then, ‘Close’
104 Design
Batch Design
2. Select ‘Analysis’
4. Click ‘Run’
105 Design
Design Result
1. Click button to
view the table summary
106 Design
Beam Design Result
107 Design
Beam Design Result
1. Check summary
Graphic
113 Design
Column Design Result - Detailed
114 Design
Column Design Result - Detailed
THANK YOU!
Midas IT Philippines
115