Quotation TMC-200915

We thank you for your inquiry, and are pleased to quote according to the enclosed specification.
TMC compressors are single-stage, oil-lubricated marine screw compressors, constructed for continuous operation in high
ambient temperatures. The compressor is supplied as a complete self-contained unit with all necessary equipment installed,
including starter. The compressor need only be connected to main power, air outlet and - if required - cooling water.

Equipment. Qty. Price Amount


TMC 49-10 1 38 905,- 38 905,-
EWNA SW - Sea water cooled - Noise red. canopy TMC 49 1
CC2 - Compressor Controller 1
Ambient temperature 45 1
400V/50Hz Y/D 1
Type Approval - DNV/GL 1
Cable Entry Bottom 1
Units Of Pressure Gauge - Bar(G) (Standard) 1
Grease Nipple El-motor DIN 71412 (Standard) 1
Total price per ship set: EUR 38 905.00

Optional equipment:

Equipment. Qty. Price Amount


TMC 44-10 1 32 293,- 32 293,-
EWNA SW - Sea water cooled - Noise reduction canopy 1
CC2 - Compressor Controller 1
Ambient temperature 45 1
400V/50Hz Y/D 1
Type Approval - DNV/GL 1
Cable Entry Bottom 1
Units Of Pressure Gauge - Bar(G) (Standard) 1

Tamrotor Marine Compressors AS

Street address/Deliveries: Tel.: +47-22 91 85 00 Bank information:


Prof. Birkelands vei 24D Fax: +47-22 91 84 93 Skandinaviska Enskilda Banken AB
NO-1081 Oslo, Norway E-mail: mail@tmc.no 0252 Oslo, Norway
Web: www.tmc.no
Postal address: Account: 9750.04.57493 (EURO)
P.O. Box 3 Furuset Organization no.: SWIFT: ESSENOKX
IBAN: 9750.04.57485 (USD)
NO-1001 Oslo, Norway NO 976 516 648 MVA SWIFT: ESSESGSG
IBAN: 9750.06.56933 (NOK)
SWIFT: ESSENOKX
GENERAL TERMS AND CONDITIONS:

Warranty: 12 months from first use, 18 months after dispatch from manufacturer, or whichever comes first. Ref.
TMC Warranty terms doc. No. 10000.

Prices: The prices given are without tax and customs duties, unless otherwise agreed upon.

Prices quoted are valid for deliveries within 31.12.2020.

Currency: Unless otherwise stated, the quoted currency is EURO.

Delivery time: 12-14 weeks, reservations to changes caused by Corona virus outbreak

Delivery: Ex Works our address according to INCOTERMS 2020. Delivery conditions according to ”General
conditions for supply of plant and machinery for export”, formula ECE 188 with addendum of 1992.
Equipment quoted as “In Stock” is subject to prior sale.

Payment: In advance

Validity: 30 days from date of offer.

Not included in the quotation, unless clearly specified:


Class society approval.
Commissioning/final approval on operation site.
Freight, travel and living expenses in connection with commissioning and warranty work.

We trust that our quotation is of interest. If further information is required, we will be pleased to be at your service.

Best regards,
Tamrotor Marine Compressors AS

Arne T. Rekdal
Senior Sales Engineer Offshore

E-Mail: ARekdal@tmc.no
Mobile: +47 99204943

Tamrotor Marine Compressors AS

Street address/Deliveries: Tel.: +47-22 91 85 00 Bank information:


Prof. Birkelands vei 24D Fax: +47-22 91 84 93 Skandinaviska Enskilda Banken AB
NO-1081 Oslo, Norway E-mail: mail@tmc.no 0252 Oslo, Norway
Web: www.tmc.no
Postal address: Account: 9750.04.57493 (EURO)
P.O. Box 3 Furuset Organization no.: SWIFT: ESSENOKX
IBAN: 9750.04.57485 (USD)
NO-1001 Oslo, Norway NO 976 516 648 MVA SWIFT: ESSESGSG
IBAN: 9750.06.56933 (NOK)
SWIFT: ESSENOKX
TMC40074 rev.00/13.02.2018

TMC 49-84 – Compressor controller 2 (TMC-CC2)


This compressor from Tamrotor Marine Compressor is a single stage, oil-lubricated marine
screw compressor, designed and manufactured for continuous operation in high ambient
temperatures. The compressor is supplied as a complete unit, including starter, with all
necessary equipment assembled on a common skid, ready for use without any special
foundations.

TECHNICAL SPECIFICATION

Control system - Main motor


- TMC Compressor Controller (TMC-CC2) lubrication service
- Pressure transmitter (analogue pressure control) time
- Temperature sensors (analogue) - Inlet valve service
- Star-Delta starting method, DOL on request time
- Phase control - Discharge valve
- Modbus ready service time

Full automatic, continuous running control Fault log


The compressor runs continuously, idling and loading - Memorises the last 15 failures with time and date
according to the air consumption. Goes to standby stop if - Second fault alarm signal gives new alarm in case of
there is no air consumption. active signal

Automatic stop/start running control Signals for remote monitoring (potential free contacts)
The compressor runs automatically, it stops and starts - Electric motor running signal
within the adjusted pressure levels. The number of starts - Common alarm signal
per hour is limited by a timer, and corresponds to the - Load/off-load signal
recommendations of the motor manufacturer - Stand-by signal
- Local/remote feedback
Digital display - External pressure reading (4 – 20mA)
- Pressure display, discharge pressure
- Running temperature Signals for remote control
- Menu-based text and graphic display, compressor - Remote start/stop, 2-wire, 4-wire or 24V
monitoring - Remote emergency stop
- Ampere meter - Remote load/unload
- Running hours and load hours
Electrical motor
Control panel equipment - IP 55, F-class insulation, 2-poled
- Main switch - Space heater with switch and orange lamp
- On button, off button, reset button (integrated in - Thermistor protection
controller) - Duty cycle - S1 continuous
- Emergency stop button - Dimensioned tested for operation in relevant
- Red alarm LED (integrated in controller) temperature
- Green running LED (integrated in controller) - Fan on main motor shaft
- White power on LED (integrated in controller) - Grease nipples and vibration probes
- Local/Remote switch
- Separate IE/PE Other standard equipment
- Three stage oil separation system
Alarm indication - Oil level sight glass
- Common alarm lamp + display text - Air/oil separator equipped with safety valve
- High running temperature - Oil separator receiver
- High discharge temperature - Liquid tight baseplate with drain plug
- Inlet filter element diff. pressure high - Inlet valve
- Oil separator element, differential - Discharge/non-return valve
pressure high - Inlet filter
- Service time - Oil filter
- Oil separator filters
Safety shut downs - Oil cooler and compressed air after cooler
- Constant alarm light indication (shut down) - Thermal mixing valve
- Common alarm lamp + display text - Water separator
- Excessive running temperature - Aut. drain control
- Motor overload, thermistor-based - Sound absorbing canopy
- High pressure shut down at 10% above max - Halogen free marine cables
pressure - Built in vibration dampers
- Over current, phase fault - Cable marking
- Door stopper on el. box
Service countdown system for - Paint colour, Munsell No. 7.5 BG 7/2
- Oil change
- Inlet filter element change
- Oil filter element change
- Oil separator elements change
1/1
Doc.no MDATA2032 FOR QUOTATION ONLY TMC 49 - 10 EA / EW
400 V / 50 Hz Y/D 690 V / 50 Hz DOL Max Amb. 45 C° 10

Capacity and power consumption


Normal working pressure (barg) 9
Capacity at normal working pressure (m³/h) 508,2
Capacity at normal working pressure (m³/min) 8,47
Shaft power at normal working pressure (kW) 60,3
Maximum working pressure (barg) / (MPag) 10 / 1
Minimum working pressure (barg) / (MPag) 5 / 0,5
Idling shaft power consumption (kW) 13,3
Male rotor speed (rpm) 4592
Transmission: Gear, i= 1,541

Cooling
Allowed ambient temperature MIN - MAX (C°) 0 - 45
Compressed air temp. above cooling medium temp. (C°) * 6- 8
Air cooled compressors (EA) *
Max. cooling air pressure drop (Pa) 30
Cooling air temperature rise (C°) 17
Water cooled compressors (EW)
Water flow (l/s), Fresh water cooled at 60% air humidity / 45°C temp 0,8
Water in (max) / water out (max) (C°), Fresh water cooled 36 / 61
Min water inlet pressure with zero back pressure (bar)/(MPa), Fresh water 1,0 / 0,10
Water flow (l/s), Sea water cooled at 60% air humidity / 45°C temp 1,5
Water in (max) / water out (max) (C°), Sea water cooled 36 / 50
Min water inlet pressure with zero back pressure (bar)/(MPa), Sea water 2,0 / 0,20
Max. water inlet pressure (bar) 6
Water in / out T2 / T3 (Standard) ISO 228/1 G 1 external
Oil cooler heat rejection (kW) 45
After cooler heat rejection (kW) at 60% air humidity / 45°C temp 23
Heat dissipation (kW) EA / EW ** 57,2 / 5,1

Motor and electrical values


Main motor nominal power (kW) 45
Main motor max power, F-class temp rise (kW) 68,5
Main motor protection details IP55, F-class
Speed of rotation (rpm) - main motor 2980
Fan motor (kW) EA 1,50
Speed of rotation (rpm) - fan motor 1435
Voltage tolerance +/-5%
Fuse (max) (A) 400V / 690V 125 / 80
Current for package (A) 400V / 690V EA: 124 / 72 II EW: 121 / 70
Starting current la/ln DOL / Y/D / SOFT 9,3 / 3,1 / < 4
Control voltage (V) 230/24

General technical data


Cooling air flow for ventilation of compressor room (m³/s) EA / EW *** 2,99 / 0,41
Oil quantity (l) EA / EW 31 / 31
Oil carryover (mg/m³) 3
Air outlet - air cooled T1 (Standard) ISO 228/1 G2,5 external
Air outlet - water cooled T1 (Standard) ISO 228/1 G2,5 external
Condensate drain T4 (Standard) ISO 228/1 G 1/2 external
Weight without canopy (kg) EW 1150
Weight with canopy (kg) EA / EW 1300 / 1300
General arrangement drawing without canopy: FW / SW 22000347 / 22000364
General arrangement drawing with canopy: FW / SW 22000344 / 22000349
General arrangement drawing with canopy EA 22000345
Cable gland: Power (Standard) 1 x M63
Cable gland: Alarm / Signal (Standard) 2 x M20
Noise data**** [dB(A)]
Sound pressure level (LpA) / power level (LWA) without canopy EW 85 / 102
Sound pressure level (LpA) / power level (LWA) with canopy EW 79 / 96
Sound pressure level (LpA) / power level (LWA) with canopy EA 80 / 97
Capacity and power consumption measured according to ISO 1217, Annex C

* Air cooled data is based on 0% air humidity *** Calculated with 10°C temperature difference between room temp. and cooling air inlet temp.

** To be used in compressor room ventilation calculation **** Noise values determined according to ISO 2151 and ISO 3744, Uncertainty KpA / KWA 3 dB

Extra notes:
DOC. REF.: MDATA2032 REV.1 19.12.2018
Item Description
T1 Air outlet
T2 Water in
T3 Water out
T4 Condensate drain
TMC40083 rev.00/23.08.2018

TMC 35-44 – Compressor controller 2 (TMC-CC2)


This compressor from Tamrotor Marine Compressor is a single stage, oil-lubricated marine screw compressor, designed and
manufactured for continuous operation in high ambient temperatures. The compressor is supplied as a complete unit, including
starter, with all necessary equipment assembled on a common skid, ready for use without any special foundations.

TECHNICAL SPECIFICATION

Control system - Oil change


- TMC Compressor Controller (TMC-CC2) - Inlet filter element change
- Pressure transmitter (analogue pressure control) - Oil filter element change
- Temperature sensors (analogue) - Oil separator elements
- Star-Delta starting method, DOL on request change
- Phase control - Main motor lubrication
- Modbus ready service time
Full automatic, continuous running control - Belt service time
The compressor runs continuously, idling and loading - Inlet valve service time
according to the air consumption. Goes to standby stop if - Discharge valve service time
there is no air consumption. Signals for remote monitoring
Automatic stop/start running control (potential free contacts)
The compressor runs automatically, it stops and starts - Electric motor running signal
within the adjusted pressure levels. The number of starts - Common alarm signal
per hour is limited by a timer, and corresponds to the - Shut down signal
recommendations of the motor manufacturer - Load/off-load signal
- Stand-by signal
Digital display - Local/remote feedback
- Pressure display, discharge pressure - External pressure reading (4 – 20mA)
- Display, running temperature
- Display, discharge air temperature Signals for remote control
- Menu-based text and graphic display, compressor - Remote start/stop, 2-wire, 4-wire or 24V
monitoring - Remote emergency stop
- Motor current - Remote load/unload
- Display for running hours and load hours - Remote/system pressure input (4-20mA)
- PMS system (start request, start granted)
Control panel equipment
- Main switch Electrical motor
- On button, off button, reset button (integrated in - IP 55, F-class insulation, 2-poled
controller) - Space heater with switch and orange lamp
- Emergency stop button - Thermistor protection
- LED on control panel: Red alarm, Green - Duty cycle - S1 continuous
status/running, White power on - Dimensioned tested for operation in relevant
- Space heater (orange) with switch temperature
- Display for running hours and load hours - Fan on main motor shaft
- Automatic restart after power failure (selectable) - Grease nipples and vibration probes
- Selector switch for selecting Local or Remote Other standard equipment
Enable/disable of compressor - Enduro™ air end with belt drive
- Separate IE/PE - Automatic belt tensioning system
Alarm indication - Three stage oil separation system
- Common alarm lamp + display text - Oil level sight glass
- High running temperature - Air/oil separator equipped with safety valve
- High discharge temperature - Inlet valve
- Inlet filter element diff. pressure high - Discharge/non-return valve
- Oil separator element, differential - Inlet filter
pressure high - Oil filter
- Service time - Oil separator filters
- Oil cooler and compressed air after cooler
Safety shut downs - Thermal mixing valve
- Constant alarm light indication (shut down) - Water separator
- Common alarm lamp + display text - Level controlled drain
- Excessive running temperature - Sound absorbing canopy
- Motor overload, thermistor-based - Halogen free marine cables
- High pressure shut down at 10% above max - Built in vibration dampers
pressure - Cable marking
- High discharge air temperature - Door stopper on el. box
- Over current, phase fault - Paint colour, Munsell No. 7.5 BG 7/2
Fault log
- Memorises the last 15 failures with time and date
- alarm indications and shut downs
- Second fault alarm signal gives new alarm in case of
active signal
Service countdown system for
1/1
Doc.no MDATA2200 FOR QUOTATION ONLY TMC 44 - 10 EA / EW
400 V / 50 Hz Y/D 690 V / 50 Hz DOL Max Amb. 45 C° 10

Capacity and power consumption


Normal working pressure (barg) 9
Capacity at normal working pressure (m³/h) 293,0
Capacity at normal working pressure (m³/min) 4,88
Shaft power at normal working pressure (kW) 37,8
Maximum working pressure (barg) / (MPag) 10 / 1
Minimum working pressure (barg) / (MPag) 3 / 0,3
Idling shaft power consumption (kW) 8,3
Male rotor speed (rpm) 4435

Cooling
Allowed ambient temperature MIN - MAX (C°) 0 - 45
Compressed air temp. above cooling medium temp. (C°) * 5 - 10
Air cooled compressors (EA) *
Cooling air flow (m³/s) 1,8
Max. cooling air pressure drop (Pa) 50
Cooling air temperature rise (C°) 15
Water cooled compressors (EW)
Cooling air flow (m³/s) 1,8
Water flow (l/s), Fresh water cooled at 60% air humidity / 45°C temp 0,6
Water in (max) / water out (max) (C°), Fresh water cooled 36 / 61
Water flow (l/s), Sea water cooled at 60% air humidity / 45°C temp 1,2
Water in (max) / water out (max) (C°), Sea water cooled 36 / 50
Min water inlet pressure with zero back pressure (bar)/(MPa) (Serial) 0,8 / 0,08
Max. water inlet pressure (bar) 6
Water in / out T4 / T3 (Standard) ISO 228/1 G 3/4 external
Oil cooler heat rejection (kW) 28
After cooler heat rejection (kW) at 60% air humidity / 45°C temp 13
Heat dissipation (kW) EA / EW 35,9 / 3,2

Motor and electrical values


Main motor nominal power (kW) 37
Main motor max power, F-class temp rise (kW) 45,5
Main motor protection details IP55, F-class
Main motor temperature rise B-class
Speed of rotation (rpm) - main motor 2970
Fan motor (kW) EA / EW
Speed of rotation (rpm) - fan motor
Voltage tolerance +/- 5%
Fuse (max) ( 400 V) (A) 100
Fuse (max) ( 690 V) (A) 63
Current for package ( 400 V) (A) 75
Current for package ( 690 V) (A) 43
Starting current la/ln DOL / Y/D 9,5 / 3,2
Control voltage (V) 230/24

General technical data


Oil quantity (l) 11
Oil carryover (mg/m³) 3
Air outlet - air cooled T1 (Standard) ISO 228/1 G 1 1/4 external
Air outlet - water cooled T1 (Standard) ISO 228/1 G 1 1/4 external
Condensate drain T2 (Standard) ISO 228/1 G 1/2 external
Weight with canopy (kg) 750
General arrangement drawing with canopy EA 22000386
General arrangement drawing with canopy EW 22000388
Cable gland: Power (Standard) M50
Cable gland: Alarm / Signal (Standard) 2 x M16
Noise data [dB(A)]
Sound pressure level (LpA) / power level (LWA) with canopy EA 80 / 96
Sound pressure level (LpA) / power level (LWA) with canopy EW 80 / 96

Capacity and power consumption measured according to ISO 1217, Annex C * Air cooled data is based on 0% air humidity
Noise values determined according to ISO 2151 and ISO 3744, Uncertainty KpA / KWA 3 dB
Motor nominal power and temperature rise according to IEC60034-1

Extra notes: IE3


DOC. REF.: MDATA2200 REV. 6.2.2018