MESURES DE DENSITE EN PLACE au DENSITOMETRE A MEMBRANE GA-LABO-R4-F27-V0

In situ density measurements with a membrane densitometer

#N/A NF P 94-061-2 5/14/2019

Contract No. H359304 Earthworks - Valley Beneficiation Plant and Railway Station Storage

Works Compaction 1st Layer Pk165-167 Material Pisolite


Part of Works South Road Zone PK165- PK167 Proctor OPM

Date of set up 8/5/2020 Reception Date 8/5/2020 Dry Density (t/m3): 1.76
Implementation workshop Hydro-Compacting Reception Hour 14h45 Moisture Content (%): 20.00
Compactor: CA512 Number of pass 6 Speed Specific Weight (t/m3): 2.74

MEASUREMENT POINT 3 4

Zone No PK165 PK167


Distance from the axis

MEASUREMENT

1st Reading (V0) 150.0 151

2nd Reading (V1) 2620.0 2626

Volume of the hole V = (V1-V0) 2470.0 2475

Hole depth 15.0 15.0

Weight of wet material WW 4800.0 4887.0

Wet density WD = WW/V 1.951 1.974


###
MOISTURE CONTENT

Tare Number A1 A2

Wet material weight + tare WeWt g 576 586

Dry material weight + tare DWt g 540 548

Tare weight g 305 305

Dry material weight DW 235 243

Weight of water WWa = WeWt - DWt 36 38

Moisture Content W = (WWa x 100)/DW 15.30 15.6

Means Moisture Content % 15.30 15.6


Dry density DD (WD x 100) / (100 +
w)
t/m3 1,692 1.707
Compactness C1 = (DD*100) / DDOPM % 96.1 97.0
Layer Thickness after survey cm

Laboratory Technician Laboratory Manager Engineer HATCH COMILOG


#N/A