Professional Documents
Culture Documents
Sensor de Velocidad Cero PDF
Sensor de Velocidad Cero PDF
Process Protection
Motion sensors
SITRANS WM100
■ Overview
■ Technical specifications
SITRANS WM100 is a heavy-duty zero-speed alarm switch. This Mode of operation
non-contacting unit provides cost-effective equipment Measuring principle Disruption of magnetic field by
protection even in the harshest conditions. ferrous target
Typical application Monitors absence or presence of
■ Benefits motion in harsh conditions
• Up to 100 mm (4") gap between SITRANS WM100 and targets Output
• Rugged, low maintenance suitable for tough environments Contact 1 SPDT Form C dry relay contact,
• 1 SPDT Form C relay contact rated 5 A at 250 V AC, fail-safe
operation
• Provides cost-effective protection
Time delay Start up: 10 ... 14 seconds
• Visual indication of target triggered pulse (5 ... 7 seconds with 12 ppm
jumper installed)
■ Application Zero Speed (selected via a com- • 5 seconds ± 1 (minimum speed
mon jumper) 10 to 15 ppm) or
This rugged unit is impervious to dust, dirt, build-up and mois-
• 10 seconds ± 2 (minimum speed
ture and is ideal for such primary industries as mining, aggre-
gate, and cement. Operating where other systems are prone to
5 to 7.5 ppm) 7
failure, the non-contacting design eliminates the need for lubri- Rated operating conditions
cating, cleaning and part replacement. Downtime and clean-up Operating temperature -40 ... +60 °C (-40 ... +140 °F)
expenses associated with conveying equipment failure are re-
duced by the SITRANS WM100. It alarms to minimize spillage, Design
prevent extensive damage or even fire caused by belt slippage Probe body Aluminum
at the head pulley and warn against conveyor malfunction.
Process mounting 2" NPSL
The SITRANS WM100 has built-in selectable start delays and Connection box Aluminum, ¾" NPT conduit
1 Form C relay contact. With an aluminum body, it operates from entrance, 5 screw terminals plus
-40 to +60 °C (-40 to +140 °F). grounding terminal for electrical
• Key Applications: tail pulleys, driven pulleys, motor shaft sens- connection, max. 12 AWG
(3.30 mm2) wire size
ing, screw conveyor flights, bucket elevators
Gasketing Neoprene
■ Design Display Red LED for verification of pulses
Enclosure rating Type NEMA 4x, 6, IP67
Mounting
Dynamic range Minimum 6 or 12 pulses per
The WM100 probe should be mounted, using the supplied minute
mounting flange, onto a vibration-free structure. The gap be- Maximum 3000 pulses per minute
tween the probe and the target should be sufficient such that
there is no danger of the target damaging the probe. The maxi- Shipping weight 2 kg (4.4 lbs)
mum allowable gap is 100 mm (4") from the face of the target to Power supply • 115 V AC/50 to 60 Hz, 7 VA
the face of the probe for 4.5 x 4.5 mm (3/16 x 3/16") keyway. The • 230 V AC/50 to 60 Hz, 7 VA
WM100 is sensitive to lateral disturbances to its magnetic field. • ± 10 % of rated voltage
If the WM100 is responding to motion from an interfering target,
move the WM100 or install a ferrous plate (steel) as a shield be- Certificates and approvals CSAUS/C, CE, C-TICK
tween the WM100 and the interfering target. Where possible, the
probe should be mounted such that the cable inlet is pointing
downward to avoid accumulation of condensation in the casing.
Connection of the probe should be made via flexible conduit for
easier removal or adjustment of the probe.
Process Protection
Motion sensors
SITRANS WM100
■ Dimensional drawings
Dimensions Detail A
7 226 (8.90)
Circuit cap, 197 (7.76)
133 (5.25)
card aluminum 127 (5.00)
o.d.
60 (2.38)
Mounting
10-32 Locknut, 2" NPSL,
Screw x 4 plated Aluminum 6 dia. Hole for
3/4" NPT Cap gasket, Casing gasket, probe body 1/4-20 bolt or drill
Conduit neoprene neoprene and tap on 114 (4.5)
entrance BCD, 4 places
Casing, Mounting flange,
aluminum see detail A
95 (3.75) dia.
Probe clearance
hole
Process Protection
Motion sensors
SITRANS WM100
■ Schematics
Detection Terminal block
indicator LED for customer
connection
Terminal
circuit card
Note 3
Note 2
Note 1
1TB
8 7 5 4 3 2 1
5SEC/
12PPM
L2/N
L1
NC
COM
NO
115/230 VAC
50/60 HZ 2.5 VA
Ground terminal
for customer
connection