You are on page 1of 2

HEAT EXCHANGER SHELL ID CALCU

Shell ID according to Table 1

Number of Tubes 9577


Tube OD mm 20 0.02 meter

For Triangular Pitch


Bundle Diameter(ID) 2.473 meter
Shell ID 2.523 meter
For Squar Pitch
Bundle Diameter(ID) 2.555 meter
Shell ID 2.605 meter

By Simple geometry
Triangular Pitch 0.031 Meter
Area of the Pitch 0.001 Meter2
Total Area 8.099 Meter2

Bundle ID 3.211 Meter


Shell Id 3.261 Meter

Prem Baboo
LL ID CALCULATIONS
Table1

Triangular pitch

Number of Passes 1 2 4 6 8

K1 0.319 0.249 0.175 0.0743 0.0365

n 2.14 2.207 2.285 2.499 2.675

1/n 0.46729 0.453104 0.437637 0.40016 0.373832

Squar pitch

Number of Passes 1 2 4 6 8

K1 0.215 0.156 0.158 0.0402 0.0331

n 2.207 2.291 2.263 2.617 2.643

1/n 0.453104 0.436491 0.441891 0.382117 0.378358