SYSTEM LINE DIAGRAM

UNGROUNDED CURRENT CARRYING CONDUCTOR


GROUNDED CURRENT CARRYING CONDUCTOR
EQUIPMENT GROUNDING CONDUCTOR (EGC & GEC)
MONITORING WIRING
L1
L2
N
SOLAR
MODULE

TOOL BOX
265W
#14 AWG

-+ #8 AWG MORNINGSTAR
+ SURE SINE
REMOTE
- 300W
#10 PV WIRE #8 AWG
3 #14 AWG
INVERTER

#8 AWG AC OUT
ROOFTOP MOUNTED #10 PV #14 AWG
LB WITH DECKTITE WIRE #8 AWG
FLASHING
#14 AWG
2
MS BATTERY 15A 2A 15A
CAPACITY METER USB
#22 AWG OUTLET

#22 AWG AC
A A ON/OFF OUTLET
4 5 SWITCH
#8 AWG THWN

KEYED NOTES:
1 #8 AWG THWN

1 50A LITTLEFUSE IN LINE FUSE

2 PHOENIX PV CONNECTORS, MALE & FEMALE, 27A, 1500V


VENTED BATTERY BOX
+ - 3 SUNSAVER MPPT 15A CHARGE CONTROLLER
NOCO
MODEL# GROUP 27 4 INSTALL METER ON TOP OF TOOL BOX

5 ANDERSON CONNECTOR, 75A, 600V, 16-6 AWG

BATTERY NOTE: ALL WIRING #10 AWG THWN


UNLESS OTHERWISE NOTED
TROJAN T1275 PLUS BATTERY
12 V, 150 AMP-HR

INTERCONNECTION STANDARDS COMPLIANCE

PV MODULE
PV MODULE
SPECIFICATIONS
SPECIFICATIONS INVERTER
INVERTER
SPECIFICATIONS
SPECIFICATIONS THE INVERTERS LISTED HAVE BEEN TESTED AND LISTET BY
UNDERWRITERS LABORATORIES TO BE IN COMPLIANCE WIH
UL1741 STATIC INVERERS AND CHARGE CONTROLLERS FOR
USE IN PHOTOVOLTAIC SYSTEMS, AS WELL AS IEEE-929-2000
ROCCCOMENDED PRACTICE FOR UTILITY INTERFACEOF
PHOTOVOLTAIC (PV) SYSTEMS.

IEEE-929-2000 PROVIDES GUIDANCE REGARDING EQUIPMENT


AND FUNCTIONS NECESARRY TO ENSURE COMPATIBLE
OPERATION OF PHOTOVOLTAIC SYSTEMS CONNECTED IN
PARALLEL WITH THE ELECTRIC UTILITY.

UL1741 IS THE STANDARD APPLIED BY UNDERWRITERS


LABORATORY TO THE INVERER TO VERIFY IT MEETS THE
RECCOMENDATIONS OF 1EEE-929-2000. REFER TO BOTH
DOCUMENTS FOR DETAILS OF THE RECOMMENDATIONS AND
TEST PROCEDURES.