You are on page 1of 1

>> label disesuaikan dengan Perangkat/Subrack/Board/Port aktual di site, seperti contoh terlampir

Label at WRFU >> RRU 0_GL 1800 RRU 1_GL 1800 RRU 2_GL 1800 Label at WRFU >>

RRU 0_GL 1800 RRU 1_GL 1800 RRU 2_GL 1800


ANTENNA SECTOR 1
RRU 0_UL 2100 RRU 0_UL 2100 RRU 2_UL 2100
ANTENNA SECTOR 2 RRU 3_UL 2100 RRU 4_UL 2100 RRU 5_UL 2100

UPEU -EXT-ALM0” UPEU -EXT-ALM1” Sensor Smoke

ANTENNA SECTOR 3 Label Alarm >>


to USLP out 0

USLP-IN2.1 & IN2.2”


to Phase Failure at ACPDB
to USLP out1

USLP-IN2.3 & IN2.4” to Arrester


Failure at ACPDB
Detector
Sensor Alrm
Temperatur
Label CPRI di UBBP >> BBU/UBBP/CPRI 0_GL1800 BBU/UBBP/CPRI 1_GL1800 BBU/UBBP/CPRI 2_GL1800 Label CPRI di WRFU >> MRFU 0/CPRI 0_GL1800 MRFU 0/CPRI 1_GL1800 MRFU 0/CPRI 2_GL1800
from WRFU/RRU RRU 0/CPRI 0_GL1800 RRU 0/CPRI 1_GL1800 RRU 0/CPRI 2_GL1800 from UBBP BBU/UBBP/CPRI 0_GL1800 BBU/UBBP/CPRI 1_GL1800 BBU/UBBP/CPRI 2_GL1800

BBU/UBBP/CPRI 0_GL1800 BBU/UBBP/CPRI 1_GL1800 BBU/UBBP/CPRI 2_GL1800 MRFU 0/CPRI 0_GL1800 MRFU 0/CPRI 1_GL1800 MRFU 0/CPRI 2_GL1800
RRU 0/CPRI 0_GL1800 RRU 0/CPRI 1_GL1800 RRU 0/CPRI 2_GL1800 BBU/UBBP/CPRI 0_GL1800 BBU/UBBP/CPRI 1_GL1800 BBU/UBBP/CPRI 2_GL1800

BBU/UBBP2/CPRI 0_UL2100 BBU/UBBP2/CPRI 1_UL2100 BBU/UBBP2/CPRI 2_UL2100 WRFU 0/CPRI 0_UL2100 WRFU 0/CPRI 1_UL2100 WRFU 0/CPRI 2_UL2100
RRU 0/CPRI 0_UL2100 RRU 0/CPRI 1_UL2100 RRU 0/CPRI 2_UL2100 BBU/UBBP2/CPRI 0_UL2100 BBU/UBBP2/CPRI 1_UL2100 BBU/UBBP2/CPRI 2_UL2100

BBU/UBBP2/CPRI 0_UL2100 BBU/UBBP2/CPRI 1_UL2100 BBU/UBBP2/CPRI 2_UL2100 WRFU 0/CPRI 0_UL2100 WRFU 0/CPRI 1_UL2100 WRFU 0/CPRI 2_UL2100
RRU 0/CPRI 0_UL2100 RRU 0/CPRI 1_UL2100 RRU 0/CPRI 2_UL2100 BBU/UBBP2/CPRI 0_UL2100 BBU/UBBP2/CPRI 1_UL2100 BBU/UBBP2/CPRI 2_UL2100

BBU/UBBP/CPRI 0_GL1800 BBU/UBBP/CPRI 1_GL1800 BBU/UBBP/CPRI 2_GL1800 BBU/UBBP2/CPRI 3_GL1800 BBU/UBBP2/CPRI 4_GL1800 BBU/UBBP2/CPRI 5_GL1800
RTN Grounding Cable
MRFU 0/CPRI 0_GL1800 MRFU 0/CPRI 1_GL1800 MRFU 0/CPRI 2_GL1800 MRFU 3/CPRI 3_GL1800 MRFU 4/CPRI 4_GL1800 MRFU 5/CPRI 5_GL1800

BBU/UBBP/CPRI 0_GL1800 BBU/UBBP/CPRI 1_GL1800 BBU/UBBP/CPRI 2_GL1800 MRFU 3/CPRI 3_GL1800 MRFU 4/CPRI 4_GL1800 MRFU 5/CPRI 5_GL1800
RTN Grounding Cable
MRFU 0/CPRI 0_GL1800 MRFU 0/CPRI 1_GL1800 MRFU 0/CPRI 2_GL1800 BBU/UBBP2/CPRI 3_GL1800 BBU/UBBP2/CPRI 4_GL1800 BBU/UBBP2/CPRI 5_GL1800

BBU/UBBP2/CPRI 0_UL2100 BBU/UBBP2/CPRI 1_UL2100 BBU/UBBP2/CPRI 2_UL2100 BBU/UBBP2/CPRI 3_UL2100 BBU/UBBP2/CPRI 4_UL2100 BBU/UBBP2/CPRI 5_UL2100
DDF grounding Cable
WRFU 0/CPRI 0_UL2100 WRFU 0/CPRI 1_UL2100 WRFU 0/CPRI 2_UL2100 MRFU 3/CPRI 3_UL2100 MRFU 4/CPRI 4_UL2100 MRFU 5/CPRI 5_UL2100

BBU/UBBP2/CPRI 0_UL2100 BBU/UBBP2/CPRI 1_UL2100 BBU/UBBP2/CPRI 2_UL2100 MRFU 3/CPRI 3_UL2100 MRFU 4/CPRI 4_UL2100 MRFU 5/CPRI 5_UL2100
DDF grounding Cable
WRFU 0/CPRI 0_UL2100 WRFU 0/CPRI 1_UL2100 WRFU 0/CPRI 2_UL2100 BBU/UBBP2/CPRI 3_UL2100 BBU/UBBP2/CPRI 4_UL2100 BBU/UBBP2/CPRI 5_UL2100

USLP-IN2.1 & IN2.2” Phase Failure at ACPDB PGND cable TP 48 GROUNDING KIT POWER RRU GROUNDING KIT POWER GROUNDING KIT POWER
Ethernet cable at UMPT to Phase Failure at ACPDB to USLP-IN2.1 & IN2.2” Sensor Door Open to Grounding BAR GL 1800 Cell 0 RRU GL 1800 Cell 1 RRU GL 1800 Cell 2

USLP-IN2.3 & IN2.4” to


ULFP out Arrester Arrester Failure at ACPDB Sensor Baterry Grounding Cable GROUNING KIT POWER RRU GROUNDING KIT POWER GROUNDING KIT POWER
Failure at ACPDB to USLP-IN2.3 & IN2.4” Temperature Cabinet TP 48 UL 2100 Cell 0 RRU UL 2100 Cell 1 RRU UL 2100 Cell 2

BTS3900A/BBU/UMPT/FE/GE 0 BTS3900A/BBU/UMPT/FE/GE 0 BTS3900A/BBU/UMPT/FE/GE 0 RTN/GE/FE___________________ RTN/GE/FE___________________ RTN/GE/FE___________________


Direc UMPT to RTN Grounding DCDU
RTN/GE/FE___________________ RTN/GE/FE___________________ RTN/GE/FE___________________ BTS3900A/BBU/UMPT/FE/GE 0 BTS3900A/BBU/UMPT/FE/GE 0 BTS3900A/BBU/UMPT/FE/GE 0

APM30 APM30 APM30 power RRU 0 GL 1800 power RRU 1 GL 1800 power RRU2 GL 1800
Power At APM Grounding DCDU
power UPEUc power UPEUc power UPEUc RRU 0 GL 1800 RRU 1 GL 1800 RRU 2 GL 1800

Phase R TP48200 Phase S TP48200 Phase T TP48200 Phase N TP48200 power RRU 0 UL 2100 power RRU 1 UL 2100 power RRU2 UL 2100
Power cable DCDU at RFC ACPDB/MCB L1 ACPDB/MCB L2 ACPDB/MCB L3 ACPDB N Bar RRU 0 UL 2100 RRU 1 UL 2100 RRU2 UL 2100
ACPDB/MCB L1 ACPDB/MCB L2 ACPDB/MCB L3 ACPDB N Bar +48 DCDU 1/RFC/BTS3900 -48 DCDU 1/RFC/BTS3900
Power cable DCDU at RFC Phase R TP48200 Phase S TP48200 Phase T TP48200 Phase N TP48200 to TP48200/Bar + TP48200/LLVD/Load1

DCDU 1 DCDU 1 DCDU 1 TP48 /LLVD MCB RFC 2 MCB RFC 2


label di cover DCDU label di cover MCB
TP48200/LLVD RFC 2/APM30 Existing RFC 2/APM30 Existing DCDU 1 DCDU 1 DCDU 1