Parameter listing for Micromaster 420 dated: 21.05.05 ‘The Micromaster 420 with its default factory setting can be used for a large range of simple motor control orerations. The drive can be used for more advanced operations via its more comprehensive parameter list. Specifications of the drive Input frequency: 47-63 Hz. Digital inputs: 3 programmable isolated inputs, Switchable active high / active low (Pnp / npn) Fixed frequencies: 7 Programmable. Skip Frequencies: 4 programmable, Relay outputs: 1 programmable 30 V de / SA resistive, 250 V Ac/ 2A resistive Analogue Input: 1 used for frequeney set point or PI feedback signal, 0-10-Vde Analogue Outp 1 programmable as per client requizement. 4-20 mA Serial Interface: Optional RS 232 and RS 485. Braking: DC braking / Compound braking Parameters: * Check 12006 to find the power that can be supplied by the inverter. * Change P010 back to 0 to enable run & view most of the parameters. * IfP3900 is made greater than 0 then PO10 will come back automatically to 0 after parameter set up is over. * For Factory setting enter P10~ 30 & P970 ~ 1 003 =3; expert mode to access most of the parameters. 00S = 21; displays actual frequency PO10=0; can access all parameters =1; for quick commissioning & to change motor name plate parameters = 30; for factory setting P100=0 P300= 1; asynchronous motor/induction motor P304 = 415 V;; input voltage P305 = rated current of motor from name plate P307 = rated power from name plate P310=S0HZ P311 = 1425 Rpm P700=5; USS via RS 485 P701 = 0; Digital input | disabled P702 = 0; Digital input 2 disabled P736=1 P771 =27; Analog olp function directly Proportional to motor current P731 = 52.3 ; Inverter fault (Relay state of the inverter) P757=0V: x1 (Minimum value of analog Ip) P758 = 0%: yl (% set point) 759 = 10V : x2 (Maximum value of analog V/p) P760 = 100% : y2 (% set point) P777 = 0% : x1 (% set point) P778 = 4 mA :y1( Minimum value of analog o/p). P779 = 100%: x2 ( % set point) P780 = 20 mA : y2 (maximum value of analog o/p) P1000 = 5 ; Main set point via RS 485 & No additional set point P2009 P2010 P2011 : 19200 baud rate P2014 =3000 © P700=5 & P1000=5. These parameter values are for a drive having communication with TUC 4, + If'we control the drive using digital inputs only (No communication) then enter ; P700 =2 : Control through digital inputs Onvoff for digital input 1 : Analog set point Analog Input/Output Calibration ase 2 Po76o aoe ae P0780» 20 ma ay 0x X axis PO777= 0% X axis P0757 «ov Po7sa POTTICA wa Po773 = 100% POTS =0 % wv p Te0 - | Pp (000-1 paramere fos LCS SelecHon .

You might also like