Paltronic 50 makes a difference between two different kinds of error – codes

Standard codes. These codes are shown steadily on the display and don’t integrate any further
information.

Flashing codes, which are shown with a second additional information code. The main code is
shown with a dot behind the number ( e.g. 63.) the additional information is shown without a dot
(e.g. 07).

Further the system distinguishes between status codes and error codes.

Status codes are information for the operator, which appear during the normal crane operation. By
using the crane in the right way, the status code shifts back automatically to normal operating
(00.). For example the code 03. shows an overload situation on the crane, which shifts back
automatically to code 00. when reducing the crane moment.

Status codes are characterised with a star ( * ) in the following description.

Error codes are codes signalising a mistake in the system. Even after repairing the mistake, the
code will not disappear automatically. The operator or the service technician has to reset the
system by pressing the OLP button or by restarting the system.

Error codes are characterised with two stars ( ** ) in the following description.
Paltronic (black box)

Paltronic codes here


(decimal place!)
Code Tables
Nr.1 Nr. Description Reason Solution
2

00. 00 System in normal working


* condition

01. 00 Checksum EPROM not ok Internal system check is not possible. EPROM (Chip) has to be changed in main board.
** Crane cannot be operated EPROM error of hardware version

02. 00 Checksum EEPROM not ok Internal system check is not possible. Change main board.
** Crane cannot be operated EEPROM error of hardware version

03. 00 Overload on a crane load limit Crane in overload on the shown load limit. Reduce crane load moment by operating a load moment
* general (until version 2.8) The second code tells, which limit is in decreasing movement.
01 Load limit HPLS overload. If necessary use the OLP button to lower the main boom cylinder
02 Load limit Nominal load Crane outriggers and stabilizers are not and get the crane out of a so called ”false overload situation“.
05 Negative Load limit used correctly; EN280 mode is activated in If the crane is built for workman basket mode and EN 280 code,
09 Slewing 1, Load limit 1 (SHB) the software and the input in P50 tells, that check the wiring and the signal. Otherwise deactivate the EN 280
10 Slewing 1, Load limit 2 (SHB) the basket is mounted. (Signal form relay mode in the software.
17 Slewing 2, Load limit 1 (ISC) contact K264/1). If the stabilizers and outriggers are used correctly (stabilizers
18 Slewing 2, Load limit 2 (ISC) down, outriggers fully out), check the wiring of the stabilizers
25 Slewing 3, Load limit 1 (no switches.
stab.)
26 Slewing 3, Load limit 2 (no
stab.)
06 Workman basket mode not
allowed.

04. Error safety check Internal error on micro controller. Change or change the main board.
** 01 Internal program fault
02 Fault internal RAM/Register
03 Error controller
Nr.1 Nr.2 Description Reason Solution

07. 00 Overload on rope winch Rope winch in overload. Reduce force on rope.
** Load moment (because of too high force on the rope or (Lower the rope or retract extension boom).
increasing movements hoist limiting switch active).
not possible.

10. 00 Error on emergency 12/24 V on emergency stop valve but no Check magnetic valve (short circuit)
** stop feedback. signal from Paltronic (Valve eventually Remove any external power supply.
Attention: Crane has no electrically overridden by feed power). Check output signal from Paltronic (has to be 0 V in overload
overload system in this situation when a lever is acted)
condition

10. 01 Error emergency cut off Spool in control valve is out of centre without Check magnetic valve
** feedback: crane a signal from Paltronic. Eventually the valve is overridden manually.
02 Error emergency cut off
feedback: stabilizers

11. 00 Broken connection to Broken connection to pressure transducer. Check wiring and connections (U230)
** pressure transducer on Faulty connection on pressure transducer Further: Interchange the plug U230 with U231, than reset system
main boom piston side U230. by pressing OLP.
(signal less than 1.25 If code 11 remains – broken wire
mA). If code 12 appears – change pressure transducer U 230.

12. 00 Broken connection to Broken connection to pressure transducer. Check wiring and connections (U231)
** pressure transducer on Faulty connection on pressure transducer Further: Interchange the plug U230 with U231, than reset system
main boom piston rod U231. by pressing OLP.
side (signal less than If code 12 remains – broken wire
1.25 mA). If code 11 appears – change pressure transducer U 231.
Nr.1 Nr.2 Description Reason Solution

13. 00 Broken connection to Broken connection to pressure transducer. Check wiring and connections (U236)
** pressure transducer Faulty connection on pressure transducer Further: Interchange the plug U236 with U237, than reset system
on fly-jib boom piston U236. by pressing OLP.
side (signal less than If code 13 remains – broken wire
1.25 mA). If code 14 appears – change pressure transducer U236.

14. 00 Broken connection to Broken connection to pressure transducer. Check wiring and connections (U237)
** pressure transducer Faulty connection on pressure transducer Further: Interchange the plug U236 with U237, than reset system
on fly-jib boom piston U237. by pressing OLP.
side (signal less than If code 14 remains – broken wire
1.25 mA). If code 13 appears – change pressure transducer U237.

15. 00 Broken connection to Broken connection to the level indicator or Check wiring to the level indicator on the boom.
** level indicator on system activated in the software but not If activated but not used, deactivate system via computer
crane (B1). mounted on the crane. (Paldiag.NET).
Eventually wrong switch used. If necessary change the switch to the Palfinger standard switch
(EEA 4018)
Nr.1 Nr.2 Description Reason Solution

16. 00 Broken connection to level Broken connection to the level Check wiring to the level indicator on the boom.
** indicator on fly jib (B301). indicator or system activated in the If activated but not used, deactivate system via computer
software but not mounted on the (Paldiag.NET).
crane. Eventually wrong switch If necessary change the switch to the Palfinger standard switch.
used. EEA 4018

20. 00 Too high signal value from Too high signal (above 19.7 mA) Interchange plug of the transducer U230 with U231, reset system
** pressure transducer main from pressure transducer U230. (OLP or restart).
boom piston side (U230). Short cut in the cable or defective If error 20 remains, short cut in the cable or main unit defective.
pressure transducer. If error 21 appears – change pressure transducer U230.

21. 00 Too high signal value from Too high signal (above 19.7 mA) Interchange plug of the transducer U230 with U231, reset system
** pressure transducer main from pressure transducer U231. (OLP or restart).
boom piston rod side (U231). Short cut in the cable or defective If error 21 remains, short cut in the cable or main unit defective.
pressure transducer. If error 20 appears – change pressure transducer U231.

22. 00 Too high signal value from Too high signal (above 19.7 mA) Interchange plug of the transducer U236 with U237, reset system
** pressure transducer fly jib from pressure transducer U236. (OLP or restart).
piston side (U236). Short cut in the cable or defective If error 22 remains, short circuit in the cable or main unit defective.
pressure transducer. If error 23 appears – change pressure transducer U236.

23. 00 Too high signal value from Too high signal (above 19.7 mA) Interchange plug of the transducer U236 with U237, reset system
** pressure transducer fly jib from pressure transducer U237. (OLP or restart).
piston side (U237). Short cut in the cable or defective If error 23 remains, short circuit in the cable or main unit defective.
pressure transducer. If error 22 appears – change pressure transducer U237.

30. 00 Overload on Fly Jib Fly jib in overload on the shown load Reduce fly jib load moment by operating a load moment
* general (until version 2.8) limit. The second code tells, which decreasing movement.
01 Load limit HPLS limit is in overload. If necessary use the OLP button to lower the fly jib knuckle boom
02 Load limit Nominal load cylinder and get the jib out of a so called ”false overload situation“.
05 Negative Lastgrenze
09 Reduced load limit
Nr.1 Nr.2 Description Reason Solution

32. 00 Load limit for manual extension Manual extension boom overloaded or Remove manual extension boom from overload situation (lower the
** boom reached. system activated in the software but not load)
used on the crane. Eventually deactivate system if activated but not used (PALDIAG-
Software).

41. 00 CAN – reading buffer writing error. Internal CAN error. Restart the system. If error remains, check all bus connections.
** If necessary change main unit.

42. CAN Error interrupt, Bus Off . CAN bus fault. Restart system. If error remains, check all bus connections.
** 00 No Specification If the error stays, change the CAN participants one by one. Every
01 Stuff Error time restart the system after changing.
02 Form Error
03 Acknowledge Error
04 Bit 1 Error
05 Bit 0 Error
06 CRC Error
07 unused

44. Error CAN addressing. An address is used more than once in Check addressing of the bus system, especially check the setting
** 00 General the system. The second code shows, of the display units (remember, that the RRC receiver has address
51-5F Spool position feeler boxes which address is used more than once. 61).
61-6F Display units and RRC System
71-7F Encoder

45. CAN Warning interrupt, Bus Off . Warnung am CAN bus. Check configuration of the system in the software (PALDIAG), if
** 00 No Specification necessary change and reset the configuration.
01 Stuff Error Check address switches of all CAN-participants (see Paltronic
02 Form Error description „Addressing of the system“). Check wiring.
03 Acknowledge Error Change CAN-participants one by one, always restart system after
04 Bit 1 Error changing a part by pressing OLP.
05 Bit 0 Error
06 CRC Error
07 unused
Nr.1 Nr.2 Description Reason Solution

46. 00 CAN transmitting not It is not possible to transmit a data diagram Check wiring and connections of the bus system. Restart the
** possible. due to a broken cable, a loose connection or system.
a wrong wiring of the bus system.

47. 00 CAN receiving not It is not possible to receive a data diagram Check wiring and connections of the bus system. Restart the
** possible. due to a broken cable, a loose connection or system.
a wrong wiring of the bus system. Received
data diagram not valid.

50. 00 Error initialisation of CAN CAN participant has got an unexpected Check wiring and connections of the bus system. Restart the
** participant restart. This can happen due to a faulty CAN system.
General part or a defective wiring. It is also possible, If the error happens again, change the part with the address
51-5F Spool position box that twice the same address was used. shown.
61-6F Display units and RRC If the error 50.00 occur, also check the CAN bus programming.
system Maybe a CAN part is activated, which does not exist. (example
71-7F Encoder encoder activated but not used on this crane)
Nr.1 Nr.2 Description Reason Solution

60. Error lever comparison The position of the control valve spool does If error occurs on a new product or right after programming, check
** 01 Main boom lowering not fit to the signal from the RRC system. the definition in the software.
02 Main boom lifting (Possible only on version 3.0 and higher). An error during operating can have the following reasons:
03 Outer boom lifting •During operating from RRC, somebody has moved a spool
04 Outer boom lowering manually (interrupts the comparison).
05 Slewing left •A control valve module is defective and makes an uncontrolled
06 Slewing right movement.
07 Extensions extending
08 Rope winch lifting
09 Fly jib outer boom lifting
10 Fly jib outer boom lowering
11 Fly jib extensions extending
27 Additional module active in
direction A
28 Additional module active in
direction B

61. Error CAN document from The spool position box found an internal Restart system. If error stays, change the part which is shown as
** spool position box to main error during start up. the faulty one.
unit The second box shows the address of the
99 Unknown participant faulty participant.
51 Spool position feeler crane
52 Spool position feeler crane
fly jib
53 Input box for ISC
54-5F These addresses must not
be used at all.
Nr.1 Nr.2 Description Reason Solution

62. 10 times no data diagram The spool position box found an internal Restart system. If error stays, change the part which is shown as
** (100 ms) error during operating. the faulty one.
99 Unknown participant The second box shows the address of the
51 Spool position feeler crane faulty participant.
52 Spool position feeler crane fly
jib
53 Input box for ISC
54-5F These addresses must not be
used at all.

63. Lever not in neutral position •The spool of a certain movement is Check wiring and correct connection of the spool position plug.
** during start up. activated. To test a module, one can interchange two plugs to another
01 Main boom lowering •The wire from the spool position sensor function and check, if the code changes or stays the same after
02 Main boom lifting to Paltronic is defective restart.
03 Outer boom lifting •The plug in the Paltronic spool position Stays the same -broken wire, changes – module defective
04 Outer boom lowering box is loose. If necessary, change module or cable.
05 Slewing left •The spool position sensor is defective.
06 Slewing right Check:
07 Extensions extending The diode in the spool position box has to
08 Seilwinde Lifting light up, if the spool is in neutral position.
09 Fly-Jib outer boom Lifting
10 Fly-Jib outer boom lowering
11 Fly-Jib extensions extending
27 Additional module in A-
direction
28 Additional module in B-
direction

64. Function operated in both The spool position sensor does not get a Check wiring and correct connection of the spool position plug.
** directions signal in any direction of a function. To test a module, one can interchange two plugs and check, if
01 Main boom The cable might be loose or broken (no the code changes or stays the same after restart.
03 Outer boom power supply to the module). Code changes- spool sensor , stays the same – broken wire
05 Slewing If necessary, change module or cable.
09 Fly-Jib knuckle boom
27 Additional module
Nr.1 Nr.2 Description Reason Solution

65. Error initialisation of digital The spool position box found an internal Restart system. If error stays, change the box which is shown as
** inputs error during operating. the faulty one.
99 Unknown participant The second box shows the address of the If a participant has been removed, deactivate it in the software as
51 Spool position feeler crane faulty participant. well.
52 Spool position feeler crane At 65.99: At code 65.99 check CAN bus setting the software and correct it.
fly jib Participant has been activated in the
53 Input box for ISC software, which does not exist.
54-5F These addresses must not
be used at all.

66. Document error from A display unit has found an internal error or Restart system. If error stays change display unit.
** display unit to basic unit does not react anymore. The second code
99 Unknown participant shows the address of the defective unit.
62-6F Address of display unit

67. 10 times no data diagram A display unit has found an internal error or Restart system. If error stays change display unit.
** 99 Unknown participant does not react anymore. The second code
62-6F Address of display unit shows the address of the defective unit.

68. Error during initialisation of Display unit found an internal error during Restart system. If error stays, change the box which is shown as
** display unit operating. the faulty one.
99 Unknown participant The second box shows the address of the If a participant has been removed, deactivate it in the software as
62-6F Address of display unit faulty participant. well.
At 65.99: Participant has been activated in At code 65.99 check CAN bus setting the software and correct it.
the software, which does not exist.

70. Error on data document RRC receiver found an internal error. Paltronic has found an error on the RRC system.
** 00 - from RRC receiver to main Only on new RRC systems (Scanreco P2 and Hetronic
99 unit. BMS2):
The second code on Paltronic is the first code of the RRC status
code.

71. 61 Error 10 times no diagram RRC system does not react anymore. Restart system. If code stays change RRC.
** on digital channels On new RRC systems, check status code RRC.
100 ms no signal.
Nr.1 Nr.2 Description Reason Solution

72. 61 10 times no diagram on RRC system does not react anymore. Restart system. If code stays change RRC.
** analogue channels. On new RRC systems, check status code on RRC.

73. Error of RRC initialisation At 73.61: Check data bus cable and restart system.
** (start up process) RRC system does not react anymore. If error stays, change RRC.
61 RRC address At 73.99: On new RRC systems, check status code on RRC.
99 Unknown adderss RRC has been activated in the software but
does not exist.

75. Error document form The encoder has got an internal error. Restart system. If error stays, change encoder.
** encoder to main unit. The second code is the address of the
71-7F Address of encoder. encoder (usually 7F).

76. No answer once per The encoder has got an internal error. Check wiring.
** second from encoder. The second code is the address of the Restart system. If error stays, change encoder.
71-7F Address of encoder. encoder (usually 7F).

77. Angle change too quick. The encoder turned too quickly. Restart system. If error stays, change encoder.
** 71-7F Address of encoder.

78. Initialisation error of The encoder cannot be initialized. Restart system. If error stays, change encoder.
** encoder. The second code is the address of the If the encoder has been removed, correct setting via software.
99 Unknown encoder encoder (usually 7F). At 78.99, an encoder has been activated via software, which
70-7F Address of encoder does not exist.
(usually 7F).

79. Angle check wrong The switch fort he angle check is active, but Redo the slew angle check via software.
** 71-7F Address of encoder the encoder is in a wrong position. Check, if the encoder is mounted correctly.
(usually 7F).
Nr.1 Nr.2 Description Reason Solution

80. Service interval required. Crane or rope winch requires service due to Visit workshop and reset the interval in the software.
** 01 Service interval crane (until the service interval counter
version 2.8)
02 Service interval rope winch

81. High stand limitation active The crane has been turned into the limited Move crane out of limited area.
* 01 High stand 1 (IS001) area of the high stand imitation system. If the crane is not in the limited area, check the wiring of the
11 High stand 2 A crane function has been operated in signal switches.
12 Error crane function in stabilizer mode. If the crane should not have this system, deactivate it in the
stabilizer mode software.
Take the lever back to neutral position and press OLP.

90. 00 Load limit on fly-jib Due to wrong operation, the fly-jib is Retract fly-jib extension booms, if necessary lower load by using
* overridden by 20 bar. overloaded 20 bar above the set limit. the OLP-button.
All load moment increasing
movements as well as all
lifting movements not
possible.

91. 00 Electronic main relief valve Fly-jib lifting capacity is reached but system This is no error or mistake in the system, the jib can be used with
* on fly-jib active. Fly-jib lifting not yet in overload. all free functions. This code only can appear in version 2.4 or
is not possible any more. less.

92. 00 Writing on EEPROM takes It is not possible to program the chip. Change main unit, restart the system. Power off then restart.
** too much time.

93. 00 Load limit of crane Due to wrong operation, the fly-jib is Retract crane extension booms, if necessary lower load by using
* overridden by 20 bar. overloaded 20 bar above the set limit. the OLP-button.
All load moment increasing
movements as well as all
lifting movements not
possible.

94. 00 Lever not in neutral position Hand lever still acted after overload Put all levers to neutral position.
* after overload situation. situation. If code remains, restart the system.
Nr.1 Nr.2 Description Reason Solution

95. 00 Electronic main relief Crane lifting capacity is reached but system This is no error or mistake in the system, the crane can be used
* valve on crane active. not yet in overload. with all free functions. This code only can appear in version 2.4
Crane lifting is not or less
possible any more.

96. 00 Power Fail (low voltage) Less than 9 V in the feed line.. Check feed power.
*

98. 00 System switched off Paltronic switched off with On/Off button. Start system with On/Off button.
* manually. (also possible via RRC-feed back system)

99. 00 Programmed delay after Programmed delay after overload or load Automatically shifts back to normal mode after the programmed
* overload. limit overridden via the Paldiag.NET delay time is over or the setting via computer is completed.
software.
RRC Codes (Yellow box)

RRC codes here, (decimal Place!)


Error Codes

Code 1 Code 2 Description Reason Solution Shown as Function


00. 00 No entry in error
System active, all ok System active, all ok Fixed code
memory

01. 01-16 System active,


No entry in error
analogue channel Proportional function in use Bring back lever to neutral position Flashing code
memory
used

02. 01-16
System in Standby,
Analogue channel used but Bring lever into neutral position and start
analogue channel 1- Flashing code
system not started system.
16 active

03. 01
System in Standby,
Emergency cut off button has No entry in error
emergency system on Release emergency button, restart system Flashing code
been pressed memory
transmitter active

10. 00 Radio interference Interference in the radio signal Change frequency Fixed code

01-16 No entry in error


Radio interference,
Interference in the radio signal, memory
analogue channel 1- Change frequency Flashing code
hand lever activated
16 active

11. 01 No radio signal from Transmitter switched off or out No entry in error
Start system, Flashing code
transmitter of range memory

20. 00 Programming via Complete programming / Reset System


System in programming mode Fixed code
transmitter (feed power off/on)
No entry in error
01 memory
Data deleting, Data are being deleted or Complete programming / Reset System
Flashing code
overwriting overwritten (feed power off/on)

21. 00 No entry in error


Loading new program Program downloading Complete programming, restart system Flashing code
memory
Error Codes

Code 1 Code 2 Description Reason Solution Shown as Function


30. 01 System emergency
Self check error Self check error Reset System (Power on/off) Flashing code
stop

02 Internal hardware
Internal hardware error
error

03
Internal
Internal synchronisation error
synchronisation error

04 Internal bus or COM


Internal bus or COM error
error

05
Error watchdog Error watchdog

06
Error interrupt Error interrupt
Reset system by switching it off and on
again. Therefore take out feed power
07 completely. Flashing code
Error timer Error timer
If error stays, reload file.
If error stays, change receiver.
08
Error stack Error stack

09
Internal time error Internal time error

10
Internal counter error Internal counter error

11 Internal hardware self Internal hardware self check


check error error

12 Internal plausibility
Internal plausibility check error
check error
Error Codes

Code 1 Code 2 Description Reason Solution Shown as Function


31. 01
Internal RAM error Internal RAM error

02
External RAM error External RAM error Reset system by switching it off and on
again. Therefore take out feed power
Flashing code
03 completely.
EEPROM error EEPROM error If error stays, change receiver.

04
FLASHPROM error FLASHPROM error

32. 00
Undefiniert (not used)

33. 01
Power supply > 35V Feed voltage higher than 35V Check feed line, reduce voltage
Flashing code
02 Check feed line, increase voltage (check
Power supply < 8V Feed voltage lower than 35V
quality and size of wires)

04-09
undefined

10 Voltage on dump valve not


Not allowed power on Check valve for damages or short circuit, System emergency
correct, valve might be Flashing code
dump valve check wiring stop
damaged

12 Shortcut in
Shortcut in emergency loop Check all connected users Flashing code
emergency loop

15 Shortcut on digital Shortcut on one or more digital


Check connected end users. Therefore Flashing code
output 1-6 outputs 1-6
disconnect all users and reset system. Then
16 reconnect one by one to find out the faulty
Shortcut on digital Shortcut on one or more digital
user. Check faulty user. Flashing code System emergency
output 7-12 outputs 7-12
stop
17 Error on digital output
1 Error on digital output 1 Check end user on output 1 Flashing code
feed back error
Error Codes

Code 1 Code 2 Description Reason Solution Shown as Function


34. 01-08 Feedback error on
Check valve (Danfoss module,
analogue outputs 1-8 Feed power to valve not correct. System emergency
Nordhydraulic magnetic coils). Flashing code
(power supply to Defective valve. stop
Check wiring for quality/damages.
valve).

35. 01-08
Feedback error on Analogue signal to valve not Check valve (Danfoss module,
System emergency
analogue outputs 1-8 correct. Nordhydraulic magnetic coils). Flashing code
stop
(signal to valve). Defective valve. Check wiring for quality/damages.

50. 01-16
Lever 1-16 (analogue Bring lever back to neutral position, restart
Lever 1-16 activated during start System emergency
channel) active during system. Flashing code
up or lever defective. stop
start up. If code stays, check lever.

51. 01-16 Error on analogue


channel 1-16
No safety contact (digital) Check lever (Joystick) System emergency
(Comparison Flashing code
available. Lever damaged. Change if required. stop
analogue/digital AK-
DK)

52. 01-08 Check valve (Danfoss module,


Valve error 1-8 (error Nordhydraulic magnetic coils). Change if System emergency
Error signal from valve 1-8. Flashing code
input) required. stop
Check wiring for quality/damages.

60. 00
Undefined (not used)

61. 00
Undefined (not used)

62. 00
Undefined (not used)

63. 01 Error input from start Relay K0 in receiver is not in Reset system.
locking. neutral position. If code stays, change relay.
System emergency
02 Flashing code
Start locked digital channel Bring switch to neutral position, restart stop
Error on start locked
(switch) not in neutral position system.
digital channel.
during start up. Change switch if defective.