6. Error codes of Hetronic BMS2 and Scanreco P2

Code 1 Code 2 Description Reason Solution Shown as Function


00. 00
No entry in error
System active, all ok System active, all ok Fixed code
memory
01. 01-16
System active, analogue channel No entry in error
Proportional function in use Bring back lever to neutral position Flashing code
used memory
02. 01-16 System in Standby, analogue channel Analogue channel used but system not
Bring lever into neutral position and start system. Flashing code
1-16 active started
03. 01 System in Standby, emergency Emergency cut off button has been No entry in error
Release emergency button, restart system Flashing code
system on transmitter active pressed memory
10. 00 Radio interference Interference in the radio signal Change frequency Fixed code
No entry in error
01-16 Radio interference, analogue channel Interference in the radio signal, hand
Change frequency Flashing code memory
1-16 active lever activated
11. 01 Transmitter switched off or out of No entry in error
No radio signal from transmitter Start system, Flashing code
range memory
20. 00 Complete programming / Reset System (feed power
Programming via transmitter System in programming mode Fixed code
off/on) No entry in error
01 Complete programming / Reset System (feed power memory
Data deleting, overwriting Data are being deleted or overwritten Flashing code
off/on)
21. 00 No entry in error
Loading new program Program downloading Complete programming, restart system Flashing code
memory
30. 01 System
Self check error Self check error Reset System (Power on/off) Flashing code
emergency stop
02 Internal hardware error Internal hardware error
03 Internal synchronisation error Internal synchronisation error
04 Internal bus or COM error Internal bus or COM error
05 Error watchdog Error watchdog
Reset system by switching it off and on again.
06 Error interrupt Error interrupt
Therefore take out feed power completely.
07 Error timer Error timer Flashing code
If error stays, reload file.
08 Error stack Error stack If error stays, change system.
09 Internal time error Internal time error
10 Internal counter error Internal counter error
11 Internal hardware self check error Internal hardware self check error
12 Internal plausibility check error Internal plausibility check error
31. 01 Internal RAM error Internal RAM error
Reset system by switching it off and on again.
02 Extrenal RAM error Extrenal RAM error
Therefore take out feed power completely. Flashing code
03 EEPROM error EEPROM error
If error stays, change system.
04 FLASHPROM error FLASHPROM error
32. 00 Undefiniert (not used)

20
TRAINING
M 2-2.3 BMS-2 / P2
Code 1 Code 2 Description Reason Solution Shown as Function
33. 01 Power supply > 35V Feed voltage higher than 35V Check feed line, reduce voltage
02 Check feed line, increase voltage (check quality and Flashing code
Power supply < 8V Feed voltage lower than 35V
size of wires)
04-09 undefined
10 Voltage on dump valve not correct, System
Not allowed power on dump valve Check valve for damages or shortcut, check wiring Flashing code
valve might be damaged emergency stop
12 Shortcut in emergency loop Shortcut in emergency loop Check all connected users Flashing code
15 Shortcut on one or more digital outputs
Shortcut on digital output 1-6 Check connected end users. Therefore disconnect Flashing code
1-6
all users and reset system. Then reconnect one by
16 Shortcut on one or more digital outputs System
Shortcut on digital output 7-12 one to find out the faulty user. Check faulty user. Flashing code
7-12 emergency stop
17 Error on digital output 1
Error on digital output 1 Check end user on output 1 Flashing code
feed back error
34. 01-08 Check valve (Danfoss module, Nordhydraulic
Feedback error on analogue outputs Feed power to valve not correct. System
magnetic coils). Flashing code
1-8 (power supply to valve). Defective valve. emergency stop
Check wiring for quality/damages.
35. 01-08 Check valve (Danfoss module, Nordhydraulic
Feedback error on analogue outputs Analogue signal to valve not correct. System
magnetic coils). Flashing code
1-8 (signal to valve). Defective valve. emergency stop
Check wiring for quality/damages.
50. 01-16 Lever 1-16 (analogue channel) active Lever 1-16 activated during start up or Bring lever back to neutral position, restart system. System
Flashing code
during start up. lever defective. If code stays, check lever. emergency stop
51. 01-16
Error on analogue channel 1-16 No safety contact (digital) available. Check lever (Joystick) System
Flashing code
(Comparison analogue/digital AK-DK) Lever damaged. Change if required. emergency stop
52. 01-08 Check valve (Danfoss module, Nordhydraulic
System
Valve error 1-8 (error input) Error signal from valve 1-8. magnetic coils). Change if required. Flashing code
emergency stop
Check wiring for quality/damages.
63. 01 Relay K0 in receiver is not in neutral Reset system.
Error input from start locking.
position. If code stays, change relay.
System
02 Flashing code
Start locked digital channel (switch) Bring switch to neutral position, restart system. emergency stop
Error on start locked digital channel.
not in neutral position during start up. Change switch if defective.