One of the best selling resuscitators...

Smiths Medical is bringing you the next generation The Pneupac VR1 has been designed as a first
of emergency ventilators. The Pneupac range of response ventilator for emergency personnel in the
emergency and transport ventilators are renowned ambulance, fire and police services and also for use
throughout the world for quality and robustness. in industrial and commercial markets.
The Pneupac VR1 combines the key characteristics
of the Pneupac ventilators into a small, lightweight, The nature of the environment in which first
and highly deployable emergency ventilator. responders have to operate in requires the product
to work in demanding conditions. The key attributes
In 1974 the Pneupac 2R ventilator was launched into of the Pneupac VR1 are:
the pre-hospital market and was one of the first
units specifically designed for emergency ventilation.
Through meeting the requirements of the emergency • SIMPLICITY • PORTABILITY
services, the Pneupac 2R quickly became a market
leader in numerous countries and maintained this • SAFETY • ROBUSTNESS
position for many years. The new Pneupac VR1 is
smaller and lighter than the Pneupac 2R model.
AIRWAYMANAGEMENT

...just got smaller.

Smiths Medical offers market-leading solutions in To compliment the Pneupac VR1 a range of high
two major areas; Anaesthesia & Safety Devices and quality Portex® emergency medicine products are
Medication Delivery & Patient Monitoring. These two available including the Portex® Cricothyroidotomy Kit
areas encompass airway management, pain (PCK) and BCI® Patient Monitors. In addition carry
management, needle protection, arterial blood cases have been specifically developed to hold the
sampling, temperature management, critical care Pneupac VR1, oxygen cylinder and disposable airway
monitoring, hospital and ambulatory infusion, devices.
vascular access, surgical drainage and
insulin infusion.
AIRWAYMANAGEMENT

The Pneupac VR1. Simple, Safe, Portable and Robust

Tidal Volume/Frequency Control

Auto/Manual Control

Tidal Volume/Frequency Control Patient Demand System


There is a single control for setting the frequency A patient demand system is incorporated within the
and tidal volume, enabling the ventilator to be set ventilator which allows synchronised interaction with
rapidly for the patients’ requirements. There is a the patient’s own breathing efforts in cases of partial
detent click at the recommended adult position respiratory failure. This is only available with Pneupac
12BPM at 600ml*. VR1 and Air Mix model.

Auto/Manual Control MRI Compatible


The auto/manual control allows the operator to For in-hospital use the Pneupac VR1 is MRI
decide whether to set the ventilator in the automatic compatible to 3 Tesla.
mode or to provide ventilation manually.
Relief Valve
Air Mix Switch The high-pressure relief valve is fitted to all units at
Available on the Air Mix model, the switch allows the 40cm H2O, with a loud and distinctive alarm.
operator to deliver either 100% oxygen or 50% Alternatively a 60cm H2O valve can be factory fitted.
oxygen, prolonging the duration of the cylinder
gas supply.
*ERC/AHA/ILCOR Guidelines 2000
AIRWAYMANAGEMENT

Ergonomically designed

Air Mix Switch

Linked Manual
Controls

Gas Supply Input

Relief Valve
Patient Valve

Patient Valve Ergonomically designed


There is a high quality patient valve that can be easily The Pneupac VR1 has been designed to fit
removed for cleaning. comfortably into the hand. The shape of the unit
allows the operator to observe the face mask when
Linked Manual Controls holding the ventilator.
The linked controls on the top and bottom of the
ventilator allow the manual triggering of a single
controlled ventilation. This permits the ventilator to
be used in a variety of chest compression/ventilation
options in cardiac life support.
AIRWAYMANAGEMENT

The Complete Pneupac VR1 System

Simplicity Safety
The Pneupac VR1 has been conceived to provide The Pneupac VR1 has been designed with maximum
essential and rapid respiratory support in the most safety as a priority. Unlike other devices the Pneupac
taxing of clinical situations. The controls are therefore VR1 does not permit uncontrolled insufflation of
designed to be intuitive and simple allowing you to oxygen. The manual control triggers a single
select the appropriate ventilation (in terms of ventilation equivalent to the quantity of ventilation
frequency and volume) quickly. delivered in automatic ventilation.
AIRWAYMANAGEMENT

Portability Robust
First responders are increasingly called upon to carry The Pneupac range of ventilators, in common with
more equipment. The size of the Pneupac VR1 has other Smiths Medical products are designed to
been reduced as far as possible to provide a highly withstand the demands of emergency medicine.
portable product without compromising on key
clinical features. The new input hose is extremely
flexible, even at low temperatures and can be coiled
tightly without kinking.
Technical Specification

Product Pneupac VR1 Responder* Pneupac VR1* Pneupac VR1 Air Mix*

Product codes 520A1125 520A1123 520A1126


Principle of operation Oxygen-powered, hand-held Oxygen-powered, hand-held Oxygen-powered, hand-held
control unit with patient valve control unit with patient valve control unit with patient valve
including automatic and including automatic and including automatic and
manual modes manual modes with demand manual modes with demand
breathing breathing and Air Mix

Manual mode Preset breaths, singly or in a controlled breathing pattern may be selected by use of a push-button
or omni-directional lever

Automatic mode The ventilatory resuscitator cycles in accordance with the setting of a single control that changes the
tidal volume and frequency dependently with a constant I:E ratio of 1:2

Patient type Patients above 10kg Patients above 10kg with Patients above 10kg with
without spontaneous and without spontaneous and without spontaneous
breathing breathing breathing
Demand Not included Included Included

Control Single, calibrated, tidal volume/frequency control gives simultaneous and interdependent adjustment
of tidal volume and frequency

Tidal volume (ml) and 150/25; 300/20; 450/15; 600/12 (detent); 750/11; 900/10; 1050/10
Frequency (BPM)
Flow range (L/min) 11-32 11-32 11-32
Air Mix No No Yes
Pressure relief with 40 standard, 60 optional at point of order
pneumatic alarm (cm H2O)
Dimensions (mm) Length: 170 Length: 170 Length: 170
Height: 100** Height: 100** Height: 100**
Width: 95 Width: 95 Width: 95
Weight (kg) 370g 420g 440g

* All models claim patents pending, spontaneous breathing under power failure and they all have an IP rating IP56.
** Including patient valve.

For further information on Smiths Medical’s extensive range


of Airway Management products, please refer to our website
www.smiths-medical.com

THE DETAILS GIVEN IN THIS LEAFLET ARE CORRECT AT THE TIME OF GOING TO PRESS. THE COMPANY RESERVES THE RIGHT TO IMPROVE THE EQUIPMENT SHOWN.

For further information please call your local Smiths Medical distributor or Smiths Medical direct on +44 (0)1303 260551

Smiths Medical International Ltd


Hythe, Kent, CT21 6JL, UK
Tel: +44 (0)1303 260551 Fax: +44 (0)1303 266761
www.smiths-medical.com
For international enquiries contact your local Smiths representative
Pneupac, Pneupac VR1, Portex, BCI and PCK are trademarks of the Smiths Medical family of companies. The
symbol ® indicates that it is registered in the U.S. Patent and Trademark Office and certain other countries.
Patent pending.

© 2005 Smiths Medical Family of companies. All rights reserved. Literature NO.: LITAV2492

You might also like