Installation Instructions June 2012

Introduction REV A

Applications:
This document is for the following models:

GR-12/15/20
GRC-12
Observe and Obey: QS-12/15/20
This procedure shall be completed by a person GS-30/32/46
trained and qualified on the repair of this
machine. GS-46AV

Immediately tag and remove from service a GS-47


damaged or malfunctioning machine. GS-69DC
Repair any machine damage or malfunction
before operating the machine. Tools required:
Torx T10 screw driver
Before Starting Installation:
CAT5 Ethernet Cable
Read, understand and obey the safety rules
and operating instructions in the appropriate Laptop with an Ethernet Port and Internet Browser
operator's manual.
Be sure that all necessary tools and parts are
Glossary of terms
available and ready for use. ECM - Electronic Control Module.
Read this procedure completely and adhere GCON - Ground Controller. This ECM is located at
to the instructions. Attempting shortcuts may the ground controls.
produce hazardous conditions.
PCON - Platform Controller. This ECM is located
Indicates that a specific result is expected after at the platform controls.
performing a series of steps.
CAT5 Cable - Standard Ethernet cable used for
Indicates that an incorrect result has occurred networking purposes.
after performing a series of steps.

2 SmartLink Software Installation Part No. 216767


June 2012 Installation Instructions

REV A
Procedure
Software Version 2 Press the ground control scroll down button.

Note: Before proceeding verify the version of Result: The GCON LCD will indicate the
software installed on your machine. The software revision and hour meter information.
software revision is displayed at the GCON After 5 seconds, the ground controls LCD will
LCD. return to machine model and hour meter
information.
1 Pull out the red Emergency Stop buttons at
both the GCON and the PCON. At the GCON
turn the key switch to ground controls. SOFTWARE REV
Result: The display at the platform controls will 00000.0 Hours
show "CH".

=+ -
=+ -

Result: The display at the ground controls will


show the machine model and hour meter
information. After 3 seconds, the machine
model will not show on the display.

READY . GS1930 a GCON LCD


b scroll down button
00000.0 Hours
3 Push in the red Emergency Stop button to the
off position at both the ground and platform
controls and turn the key switch to the off
position.

Part No. 216767 SmartLink Software Installation 3


Installation Instructions June 2012

PROCEDURE REV A

Loading or Updating Machine Bootloader Mode


Software 1 Open the GCON compartment.
Note: There are two procedures available to Note: Some models will require opening the
update the machine software. These are ground control box to access the GCON.
Bootloader Mode and Machine Application
Mode. 2 Turn the key switch to the GCON position. Pull
out the red Emergency Stop button to the on
Bootloader Mode: The Bootloader mode is only position at the PCON.
available with the key switch in the GCON
position. It allows the user to update or reinstall 3 At the GCON, press and hold the Enter and
the software by directing the system into the Escape buttons. Pull out the red Emergency
Bootloader and bypassing the application Stop button to the on position at the GCON.
software. Result: The GCON LCD will display the
following screen.
Choose this mode if the GCON ECM is not
operating correctly.

Machine Application Mode: The Machine


SOFTWARE UPDATE
Application mode is available with the key switch CONNECT ETHERNET
in the GCON or PCON position. This mode of
software update requires the user to enter the
Machine Service Tool. a

Choose this mode if the machine is operating


correctly and you are updating the operating b
software.
c

a GCON LCD
b escape button
c enter button

4 SmartLink Software Installation Part No. 216767


June 2012 Installation Instructions

REV A PROCEDURE

4 Locate the diagnostic port on the side of the 7 Launch a web browser such as Internet
GCON. Remove one of the fasteners securing Explorer ® or Firefox ® on your PC or laptop.
the cover and set aside. Loosen the other Type in the IP address from step 6 into the web
fastener. Do not remove it. browser address bar and press enter.
Result: The following screen will be displayed.

a diagnostic port
8 Select the Choose File tab and navigate to the
5 Connect one end of a CAT5 Ethernet cable into
downloaded Genie Flash File (.gff).
the diagnostic port. Connect the other end into
a PC or laptop. Note: Verify it is the correct flash file.
Result: The GCON LCD will display the 9 Select the Load Flash File button to verify the
following screen. file is a .gff file.
Result: The following screen will be displayed.
OPEN WEB BROWSER
<IP ADDRESS>

6 Read and record the IP address.

Part No. 216767 SmartLink Software Installation 5


Installation Instructions June 2012

PROCEDURE REV A

10 Select the Reprogram Device (s) button to If you have any further questions regarding these
start the ECM software update. instructions or need assistance, please contact the
Genie Service Department at one of the following
Result: The following screen will be displayed
telephone numbers:
after the software update is complete.
United States: 800-536-1800
Note: Do not turn off power while the ECM is
being reprogrammed. Canada: 425-881-1800

Europe: UK 0044 1476 584 333


France 0033 237 260 986
Germany 49 4221 491 821
Iberica 0034 900 808 110
Italy 0039 075 941 8171
Sweden 0046 3157 5101
Other locations 0031 653 221 908
Middle East: 0097 143 990 381
or 0097 150 459 7937
11 Select the Run Application button to exit the
software update mode. Australia: 61 7 3456 4444

12 Push in the red Emergency Stop button and All other locations 001-425-881-1800
disconnect the CAT5 cable from the GCON.
13 Secure the diagnostic port cover using the
retaining fasteners removed in step 4. Do not
over tighten.
14 Perform function test. Refer to the Operator's
Manual on your machine.
15 Return the machine to service.

6 SmartLink Software Installation Part No. 216767


June 2012 Installation Instructions

REV A PROCEDURE

Machine Application Mode 4 Connect one end of a CAT5 Ethernet cable into
the diagnostic port. Connect the other end into
1 Open the GCON compartment. a PC or laptop.
Note: Some models will require opening the Result: The GCON LCD will display the
ground control box to access the GCON. following screen.
2 Turn the key switch to the GCON or PCON
position. Pull out the red Emergency Stop
buttons to the on position at the GCON and
OPEN WEB BROWSER
PCON. <IP ADDRESS>
Result: The display at the platform controls will
show "CH".
5 Read and record the IP address.
= + -
= + -
Note: The display will only show the IP address for
3 seconds. Press the scroll up button to
display the IP address again for another 3
seconds.
6 Launch a web browser such as Internet
3 Locate the diagnostic port on the side of the
Explorer ® or Firefox ® on your PC or laptop.
GCON. Remove one of the fasteners securing
Type in the IP address from step 5 into the web
the cover and set aside. Loosen the other
browser address bar and press enter.
fastener. Do not remove it.
Result: The following screen will be displayed.

a diagnostic port

Part No. 216767 SmartLink Software Installation 7


Installation Instructions June 2012

PROCEDURE REV A

7 Enter the following username and password 9 Select the Update Machine Software button.
then select OK.
Result: The following screen will be displayed.
Note: The username and password are case
sensitive.

Username: smart.link
Password: SL1000
Result: The following screen will be displayed.

10 Select the Choose File button and navigate to


the downloaded Genie Flash File (.gff).
Note: Verify it is the correct flash file.
8 Select the Software tab at the header bar.
11 Select the Load Flash File button to verify the
Result: The following screen will be displayed.
file is a .gff file.
Result: The following screen will be displayed.

8 SmartLink Software Installation Part No. 216767


June 2012 Installation Instructions

REV A PROCEDURE

12 Select the Reprogram Device (s) button to If you have any further questions regarding these
start the ECM software update. instructions or need assistance, please contact the
Genie Service Department at one of the following
Result: The following screen will be displayed
telephone numbers:
after the software update is complete.
United States: 800-536-1800
Note: Do not turn off power while the ECM is
being reprogrammed. Canada: 425-881-1800

Europe: UK 0044 1476 584 333


France 0033 237 260 986
Germany 49 4221 491 821
Iberica 0034 900 808 110
Italy 0039 075 941 8171
Sweden 0046 3157 5101
Other locations 0031 653 221 908
Middle East: 0097 143 990 381
or 0097 150 459 7937
13 Select the Run Application button to exit the
software update mode. Australia: 61 7 3456 4444

14 Push in the red Emergency Stop button and All other locations 001-425-881-1800
disconnect the CAT5 cable from the GCON.
15 Secure the diagnostic port cover using the
retaining fasteners removed in step 3. Do not
over tighten.
16 Perform function test. Refer to the Operator's
Manual on your machine.
17 Return the machine to service.

Part No. 216767 SmartLink Software Installation 9