You are on page 1of 5

5/17/2020 Ten Ways to Design for Intrinsic Safety - Industry Articles

Industry Article

Ten Ways to Design for Intrinsic Safety


April 04, 2016 by Tim Patel, Littelfuse

How to build electronic devices when a higher degree of safety is required.

How to build electronic devices when a higher degree of safety is required.

Introduction

There are a lot of things to consider when designing an intrinsically safe product. Flammable gasses or vapors; and
airborne dust, fibers, and filings can pose explosive hazards if sources of sparks or excess heat are present in the
environment. Over the years, hazards like these have led to catastrophic losses of property and even life.

What’s even more daunting, almost every industry related to energy or basic materials production has potentially hazardous
locations, including energy production (such as oil/gas production/refining, storage/transportation, mining, etc.), materials
processing (semiconductor fabrication, tank farms, chemicals manufacturing etc.), food production (grain milling, baking,
brewing, distilling, etc.), and many others (pharmaceutical or cosmetics manufacturing; pumping stations for gas, oil,
sewage, etc.).

In order to mitigate such hazardous potential, regulatory bodies from around the world worked in order to establish
and refine Intrinsic Safety (IS) standards meant to minimize the risk of explosions in the potentially hazardous work
environments. An IS certified device or product is designed so that it’s incapable of generating sufficient heat or spark
energy to trigger an explosion.

https://www.allaboutcircuits.com/industry-articles/ten-ways-to-design-for-intrinsic-safety/ 1/5
5/17/2020 Ten Ways to Design for Intrinsic Safety - Industry Articles
A wide variety of products must be designed for intrinsic safety (IS) in hazardous environments. UL-913 is one standard you need to be aware of
for IS.

This article touches on ten recommendations for designing circuitry for new electrically powered products intended for use
in the aforementioned potentially hazardous workplaces. The following are ten things to take into consideration during the
initial planning stages for these products.

1. Batteries Should be Selected Carefully

Batteries can pack a lot of energy, especially those based on high-density lithium-ion battery technology. When selecting
cells or batteries for use in intrinsically safe devices, take care to ensure that the cells and batteries are robust enough to
withstand the expected environmental conditions, as well as to contain or minimize the amount of electrolyte leakage that
can occur under severe short-circuit conditions.

2. Be Mindful of Multiple Power Sources

It’s quite easy to overlook the implications of having one or more facilities for connection to other devices. Most often,
circuits for low-voltage communication ports are not given proper attention because designers are so focused on
transmission and reception of data on those ports. However, each of these ports has the potential to be connected to
equipment that wasn’t designed or evaluated for intrinsic safety protection. This could result in a condition where an excess
amount of fault energy and/or power is available within the intrinsically safe device. Even when such ports are designed
only for connection to associated apparatus or intrinsically devices evaluated under the “entity concept,” take care to ensure
that the entire system maintains intrinsic safety protection.

3. Be Skeptical of Published Electrical Ratings for Semiconductors


The datasheets for many semiconductor components (e.g., zener diodes) will specify an absolute maximum power
dissipation rating for the component. However, this rating is often based on very specific temperature and mounting
conditions. Often, the given ratings in the component datasheet do not adequately reflect the conditions that the component
will be exposed to in the end-use application. Always take the time to understand and evaluate the effects that the end use
application will have on the component’s power rating, thermal rise characteristics, etc. This is essential when using
semiconductor components as shunt voltage limiters.

4. Calculate the Thermal Rise Characteristics of Power-Dissipating Components

The maximum surface temperature of components under fault conditions must be assessed for determining the appropriate
temperature class of an intrinsically safe device. To determine the maximum surface temperature of these components
analytically, you’ll need information on the components’ temperature rise characteristics. In particular, a component’s case-
to-ambient thermal resistance is required to compute the maximum case temperature of the component when dissipating a
given amount of power at a specified ambient temperature. Unfortunately, most component datasheets do not specify this
value; instead, they specify a junction-to-ambient thermal resistance. In the absence of such information, tests can be
performed to determine the required values experimentally.

5. Be Aware of Voltage-Enhancing Circuits


Although switching regulators, charge pumps, and other voltage-regulating and -enhancing circuits can be useful in
designing an efficient power supply, the same circuits pose challenges if not provided with adequate voltage limitation.
Enhanced voltage levels present at the output of such ICs can be faulted to propagate to other circuits tied to the same IC if
they aren’t adequately protected with voltage limiters. This can cause issues for separation of circuits (which is based on
the peak available fault voltage) and for the spark ignition assessment of other circuits.

Scroll to continue with content

6. Energy-Storing Components Should be Limited

Although energy-storing components like inductors, ferrite beads, and capacitors are useful as filtering components, they
pose challenges for compliance with spark ignition requirements. The energy available and stored in inductive, capacitive,
and combination LC circuits must be limited such that there is insufficient energy to cause ignition of an explosive
atmosphere. When coupled with the safety factors applied to the available fault voltage and/or current in the circuit, the
inductance and capacitance limitations can be quite challenging. To help alleviate these challenges, encapsulation may be
used to protect circuits against spark ignition.

https://www.allaboutcircuits.com/industry-articles/ten-ways-to-design-for-intrinsic-safety/ 2/5
5/17/2020 Ten Ways to Design for Intrinsic Safety - Industry Articles

This illustration details how an encapsulated fuse, in this case the Littelfuse PICO 259-UL913, limits the energy and temperature output that
would be otherwise exposed to an explosive atmosphere.

7. Available Power in Separate Circuits Should be Limited

Although one of the main goals of intrinsic safety protection is to limit the available power in a device, it can be quite
challenging to meet the industry demands for the same products. With the need for more powerful electronics to be
provided in smaller packages, the functional needs of the circuit need to be balanced with the safety needs. Quite often, the
strategy of splitting the total available power to various “separate circuits” within an intrinsically safe device is used to
provide the maximum amount of power required to drive those portions of the circuit that need the power without
compromising safety.

8. Keep Environmental Factors in Mind for Separation Distances


One of the most important keys to preserving intrinsic safety, especially when considering the application of faults, is
providing and maintaining the required separation distances between separate circuits. When it comes to separation
distances, the requirements for intrinsic safety equipment must take into account the environments in which such devices
may be installed. These environments can contain a wide array of pollutants that can affect the insulation provided between
conductive parts of circuits. It’s essential to design in sufficient space to maintain the separation of circuits necessary to
preserve intrinsic safety protection.

9. Protective Components Should be Derated

The components that are selected as safety-critical or “infallible” must meet certain construction requirements; however,
they must also be rated such that they do not experience stresses that could be detrimental to the reliability they provide.
Intrinsic safety standards require that infallible components be used at no more than two-thirds of their rated voltage,
current, and power when subjected to normal operating conditions and fault conditions (commonly referred to as “two-
thirds derated.”) This often requires selecting components that are overrated for the application but not so overrated that
they fail to provide the needed protection.

10. Protective Components Should be Selected Carefully

The fundamentals of intrinsic safety, where circuits are designed to limit the amount of energy for protection against spark
ignition and to limit the amount of power for protection against thermal ignition, depend heavily on the reliable operation
and “failure” of protective or “infallible” components. Because these components are being relied upon to function in well-
defined ways when subjected to normal operating and fault conditions within a circuit, these components must be selected
wisely. Although the intrinsic safety standards do not necessarily force the use of specific components, there are
requirements for some widely used components that have well-known operating and failure characteristics. Fuses, current-
limiting resistors, and zener diodes are commonly used to design robust voltage and current limiting circuits that can be
relied on to maintain the energy and power limitation needed for intrinsic safety.

https://www.allaboutcircuits.com/industry-articles/ten-ways-to-design-for-intrinsic-safety/ 3/5
5/17/2020 Ten Ways to Design for Intrinsic Safety - Industry Articles

Conclusion
To recap, preventing electrical equipment from becoming sources of ignition by limiting sources of electrical sparks and
high surface temperatures, as well as maintaining required separation distances is key when thinking about the design and
development of a new device or product to be used in in a hazardous workplace. Additionally, protective components need
be chosen wisely, as the whole relies on the parts. Intrinsic safety standards increase the overall safety of the final product,
which increases the level of protection of life and property in hazardous operating environments.

Want to learn more about designing for intrinsic safety? Read the Enhancing Workplace Safety in Hazardous Locations
application note.

Industry Articles are a form of content that allows industry partners to share useful news, messages, and technology with
All About Circuits readers in a way editorial content is not well suited to. All Industry Articles are subject to strict editorial
guidelines with the intention of offering readers useful news, technical expertise, or stories. The viewpoints and opinions
expressed in Industry Articles are those of the partner and not necessarily those of All About Circuits or its writers.

Content From Partners

Embedded Solutions for Medical Device Design

Content from Microchip

Continue to site
QUOTE OF THE DAY

Engineering is achieving function while avoiding failure.”
- Henry Petroski

https://www.allaboutcircuits.com/industry-articles/ten-ways-to-design-for-intrinsic-safety/ 4/5
5/17/2020 Ten Ways to Design for Intrinsic Safety - Industry Articles

https://www.allaboutcircuits.com/industry-articles/ten-ways-to-design-for-intrinsic-safety/ 5/5

You might also like