You are on page 1of 2

duraslurry

Cementitious waterproofing slurry

DESCRIPTION duraslurry with water to produce a


viscous, creamy consistency
TYPICAL PHYSICAL PROPERTIES
duraslurry is a ready-for-use (merely
add water) Portland cement based (1 volume clean water to 2,25 - 3
Fine powder,
waterproofing slurry. It consists of a volumes duraslurry). Mixing may be
which is
blend of cements, graded quartz and Appearance done by hand or mechanical mixer and
somewhat
active chemical constituents. It is should be continued until an
hygroscopic
supplied as a fine, grey powder. homogeneous, lump-free product
Bulk density 1,1 kg/ l results. In manual mixing, lumps may
USES be broken down with the gloved hand.
Service temperature
-40º C to +80º C
(fully cured)
duraslurry is an economical, easily On completion of mixing, material must
applied method of providing a Colour Grey be used within 30 minutes.
permanent waterproof skin on Never attempt to reconstitute by
Physiological effect As cement
concrete, plaster and brick surfaces. It further dilution, mixed material that has
may be used on both new and existing become too stiff to apply.
structures on either the wet or the dry
side. FEATURES & BENEFITS COVERAGE
duraslurry is recommended for: • Easy to use. 1. Waterproofing externally against
• Foundations • Economical damp earth and moist ground.
• Basements • Wide range of applications. 2 COATS using 2-3 kg/m²
• Tunnels 2. Waterproofing internally against
• Supporting walls SURFACE PREPARATION rising damp or up to 1 m head of
• Dams underground water.
• Reservoirs duraslurry is designed for use on 2 COATS using 4-5 kg/m².
• Ponds porous, absorbent surfaces. Highly Treated floor surfaces must be
• Pools porous surfaces such as common protected against subsequent
• Silos bricks should be plaster rendered traffic with a cement rendering.
before waterproofing. All surfaces 3. Waterproofing internally to retain
• Sewage plants
must be clean and sound. They must water as in reservoirs.
• Underground structures
be free of laitance, shutter release oil, Waterproofing externally against
dust, loose particles and any other more than 1 head of underground
duraslurry acts by the conversion of
foreign matter including fungal growth. water; water pressure; surfaces
the free lime in the concrete to
Large cracks and honeycomb should below the water table; earth
insoluble calcium compounds. These
be given a thin coating of duraslurry, covered slabs.
seal against capillary ingress of water
mixed as described in this data sheet. 3 COATS using 6-7 kg/m²
into the dry slurry film. Water soluble
They should then be filled with
materials in the slurry penetrate the
substrate surface where they in turn 3:1 - 4:1 sand/cement mortar prior to APPLICATION
applying the overall duraslurry
crystallize, thus anchoring the coating
system. Floor/wall joints should be cut Any surface to be treated with
to the substrate. duraslurry must not
to a dovetail and caulked with a 4:1 duraslurry must be fully saturated
be exposed to backwater pressure,
sand/cement mortar, prior to applying beforehand, preferably the day before.
running water or rain, until it has fully
the duraslurry system. Surfaces such as floors must be free
set. The treated surface must be
protected from heat and wind. Drying of ponded water and verticals must be
should be as slow as possible. BONDING / PRIMING free of water running down the face.
Note: Since the duraslurry system is Apply duraslurry by hand using either
based on a chemical reaction taking No primer required. a medium-hard block brush or a
place inside the concrete, some notched trowel.
moisture penetration can be expected MIXING Treatment must be applied in two or
until voids are sealed by the three coats. A second coat must be
crystallization process. duraslurry only needs the addition of applied as soon as the first coat can
water to be ready for use. Gauge no longer be disturbed by brushing. If
a third coat is required it must follow
Revision 9203

Karachi: Room No.1, Mezzanine Floor, Al-Hayat Chambers, A-7, Block-7/8, K.C.H.S. Tel: +92 21 4535898-99, Fax: +92 21 4558071
Lahore: 25-A, FCC, Syed Maratib Ali Road, Gulberg 4, Tel: +92 42 5763360 Fax: +92 42 5875384
within 24 hours, with the surface
having again been pre-dampened. On
horizontal surfaces duraslurry is
normally applied by brush, although
the second coat of a three-coat system HEALTH & SAFETY
may be notch trowelled. Vertical
surfaces, except for the final coat of duraslurry is alkaline and should not
the system are usually applied by be allowed contact with skin and eyes.
notch trowel. The final coat of a Avoid inhalation of dust during mixing
system must be applied by brush and by wearing dust masks. The use of
left as smooth as possible. gloves, eye protection and dust masks
is advised. Splashes into eyes should
CLEANING be washed immediately with plenty of
clean water and medical advice sought
Tools, brushes and mixing equipment thereafter.
should be cleaned immediately after
use and before material has set with Cured duraslurry is inert and
abe super brush cleaner followed by harmless.
washing with soap and water.
IMPORTANT NOTE
PROTECTION ON COMPLETION
This data sheet is issued as a guide to
duraslurry may be overpainted with a the use of the product(s) concerned.
high quality PVA/acrylic paint. Whilst abe Construction Chemicals
endeavours to ensure that any advice,
TEMPERATURE AND RELATIVE recommendation, specification or
HUMIDITY information is accurate and correct, the
company cannot - because abe has no
Do not apply if temperature is below 5 C.
o direct or continuous control over where
and how abe products are applied -
MODEL SPECIFICATION accept any liability either directly or
indirectly arising from the use of abe
products, whether or not in accordance
Cementitious waterproofing slurry
with any advice, specification,
for reservoirs, dams, basements,
recommendation, or information given
silos and sewage plants.
by the company.
The waterproofing compound will be
duraslurry, a single-component, FURTHER INFORMATION
cementitious slurry applied in
accordance with the recommendations Where other products are to be used
of abe Construction Chemicals. The in conjunction with this material, the
slurry will have a bulk density of 1,1 kg/l. relevant technical data sheets should
be consulted to determine total
requirements. abe Construction
PACKAGING Chemicals has a wealth of technical
and practical experience built up over
duraslurry is supplied in 25 kg
years in the company’s pursuit of
polyethylene lined paper bags.
excellence in building and construction
technology.
HANDLING & STORAGE

This product has a shelf life of


six months if kept in a dry cool place in
the original packaging. In more
extreme conditions this period might
be shortened.

Revision 9203

Karachi: Room No.1, Mezzanine Floor, Al-Hayat Chambers, A-7, Block-7/8, K.C.H.S. Tel: +92 21 4535898-99, Fax: +92 21 4558071
Lahore: 25-A, FCC, Syed Maratib Ali Road, Gulberg 4, Tel: +92 42 5763360 Fax: +92 42 5875384

You might also like