You are on page 1of 8

Duplex-Filter

FDP315/350
Nominal pressure 315/350 bar (4570/4980 psi)
according DIN 24550

High performance filters for modern hydraulic systems


Features
High performance filters for modern hydraulic systems
n Modular system n  rgonomic switch-over handle with safety lock
E
n Compact design and pressure compensation
n Minimal pressure drop through optimal flow n User-optimized one-hand-operation
design n Equipped with highly efficient filter elements
n Visual/electrical/electronic maintenance n Beta rated elements according to ISO 16889
indicator multipass test
n Threaded connections n Elements with high differential pressure stability
n Change over valve on upstream side and dirt holding capacity
n Approval: VW n Worldwide distribution

Type Code
F D P 315 N 010 - D A 015 S3155 - 50 N 10

pressure filter mesh


in bar 03 fineness 03µm
10 fineness 10µm

Filter function
P High pressure sealing
R Low pressure N NBR
S Suction filter F FPM
V Suction filter E EPDM
T Tank filter(built-in) V V

Filter type indicator setting


S Standard Filter Value in 0,1 bar
D Duplex filter e.g. 50 = 5,0 bar

Filter-Nominal size indicator type


Value Nominal size / 10 S3155 400 bar, opt./el., NC/NO
010 - NG100
016 - NG160
025 - NG250
040 - NG400

Filter element size


D - DIN

Design of filter housing


A Filter housing from below

Housing style
015 HD without bypass, el. indicator
Flow rate/pressure drop curve complete filter
y y
6 6
∆p [bar]

∆p [bar]

0
t1
vs
5 5

PS
3

t1

3
vst

vst
vs
PS
PS

PS
4 4
3 0
st t1
Sv vs
3
P PS 3
3
vst
PS
2 2
10
PS vst
1 1

0 x 0 x
0 20 40 60 80 100 120 0 40 80 120 160 200

FDP350 N010 V [l/min] FDP315 N016 V [l/min]

y y
6 6
∆p [bar]

∆p [bar]

5 5

10
vst

vst
PS

PS
4 4
0
t1
0
3

t3
t1

vs
vst

vs
vs

PS

PS
PS

PS

3 3
st 3
P Sv
2 2
st 10
PS v
1 1

0 x 0 x
0 60 120 180 240 300 0 100 200 300 400 500

FDP315 N025 V [l/min] FDP315 N040 V [l/min]

190 mm2/s y = differential pressure ∆p [bar]


33 mm2/s x = flow rate V [l/min]

Separation grade characteristics

y = beta-value
x = particle size [μm]

determined by multipass tests (ISO 16889)


calibration according to ISO 11171 (NIST)
Filter performance data
tested according to ISO 16889 (multipass test)

PS vst-elements with max. p = 210 bar


PS vst 3 5(C)  200

PS vst 10 10(C)  200

Quality assurance
Thes filters and filter elements are produced according to the following international standards

Norm Title
DIN ISO 2941 Hydraulic fluid power filter elements; verification of collapse/burst resistance
DIN ISO 2942 Hydraulic fluid power filter elements; verification of fabrication integrity
DIN ISO 2943 Hydraulic fluid power filter elements; verification of material compatibility with fluids
DIN ISO 2923 Hydraulic fluid power filter elements, method for end load test
DIN ISO 2924 Hydraulic fluid power filter elements; verification of flow fatigue characteristics
ISO 3968 Hydraulic fluid power-filters-evaluation of pressure drop versus flow characteristics
ISO 10771.1 Fatigue pressure testing of metal containing envelopes in hydraulic fluid applications
ISO 16889 H
 ydraulic fluid power filters-multipass method for evaluation filtration performance of a filter element

Symbols

Order numbers
Complete filter
Ordernumber Type Description Filter Surface cm2
ZKF05-00000022 FDP350N010-DA015S3155-50N10 1275
ZKF05-00000024 FDP315N016-DA015S3155-50N10 1885

ZKF05-00000026 FDP315N025-DA015S3155-50N10 3090

ZKF05-00000028 FDP315N040-DA015S3155-50N10 5240

ZKF05-00000031 FDP350N010-DA015S3155-50N03 1275

ZKF05-00000033 FDP315N016-DA015S3155-50N03 1885

ZKF05-00000035 FDP315N025-DA015S3155-50N03 3090

ZKF05-00000037 FDP315N040-DA015S3155-50N03 5240


Technical specifications
Design: line mounting filter We draw attention to the fact that all values indicated
Nominal: 315 bar (4480 psi) are average values which do not always occur in
 (FDP350N010 350 bar (4980 psi) specific cases of application. Our products are con-
Test pressure:  410 bar (5830 psi) tinually being further developed. Values, dimensions
 (FDP350N010 455 bar (6470 psi) and weights can change as a result of this. Our special-
Temperature range:  -10 °C to +120 °C ized department will be pleased to offer you advice.
Filter head material:  St
Filter housing material:  St We recommend to contact us concerning appli-
Sealing material:  NBR/PTFE cations of our filters in areas governed by the EU
Maintenance indicator setting:  ∆ p 5 bar ± 10 % Directive 94/9 EC (ATEX 95). The standard version
Electrical data of maintenance indicator: can be used for liquids based on mineral oil (corre-
Max. voltage:  10-30 V DC sponding to the fluids in Group 2 of Directive 97/23
Max. current:  1A EC Article 9). If you consider to use other fluids
Contact load:  20 W please contact us for additional support.
Type of protection:  IP 65 in inserted and
 secured status Subject to technical alteration without prior notice.
Connector:  M12x1, 4 pole

In = inlet
Out = outlet

*1 Vent screw
*2 Mounting Cavity M16x20 (FDP350N010, M10x20)
*3 Drain screw (not at FDP350N010)
Dimensions
All dimensions except “C” in mm.
Weight
Type A B C D E F G H I K L M N O P R S T U V W [kg]

FDP350N010 78 47 G¾ 423 474 110 66 92 119 314 14 45 224 SW27 130 243 119 33 64 90 119 25,0

FDP315N016 78 53 G1½ 334 396 110 75 125 135 450 23 62 300 SW30 150 271 150 65 90 100 150 56,0

FDP315N025 78 53 G1½ 424 486 110 75 125 135 450 23 62 300 SW30 150 271 150 65 90 100 150 61,0

FDP315N040 78 53 G1½ 636 574 110 75 125 135 450 23 62 300 SW30 150 271 150 65 90 100 150 66,0

Maintenance indicators
Differential pressure Indicators with optical and electrical indication

Material lower section: CuZn


Material upper section: PA6

40* = 40 mm wide

S3154, S3155

Contact type: normally open/normally closed 2 setting points


 . Setting point at 75 % of the indicating
1
pressure (normally open)
 . Setting point at 100 % of the indicating
2
pressure (normally closed)
Max. Voltage: 10-30 V DC
Max. current: 1 A
Max. Contact load: 20 W
Type of protection: IP65 in inserted and secured status
Plug connection: M12x1, 4-pole
LED 1*: Ready, LED green
LED 2*: Setting point 75%, LED yellow
LED 3*: Setting point 100%, LED red
Installation, operating and maintenance instructions
1. Filter installation 3. Element Replacement
When installing the filter make sure that Note: The maintenance indicator monitors the
sufficient space is available to remove filter filter side in operation, which is identified by the
element and filter housing. Preferably the filter position of the switching lever catch. The change-
should be installed with the filter housing over transfer valve must be switched prior filter
pointing downwards. The maintenance indicator servicing. Now the signal of the maintenance
must be visible. indicators cancelled and the red button can be
repressed again:
2. When should the filter element be replaced? 1. O perate and hold pressure equalizing lever
1. F
 ilters equipped with visual and electrical located behind switching lever. Pull catch knob
maintenance indicator: During cold starts, and swivel switching lever. Engage the catch on
the indicator may give a warning signal. Press the clear filter side. Place through or drip pan
the red button of the visual indicator once underneath to collect leaving oil.
again only after operating temperature has 2. Loosen vent screw of the filter side not in use
been reached. If the red button immediately by 2-3 turns; max. until contact is made with
pops up again and/or the electrical signal the safety stop.
has not switched off after reaching operating 3. Unscrew filter housing by turning counter-
temperature the filter element must be replaced clockwise. Clean the housing using a suitable
after the end of the shift. cleaning solvent.
2. P
 lease always ensure that you have original 4. Remove filter element by pulling down
Parker spare elements in stock: Disposable carefully.
elements cannot be cleaned. 5. Check o-ring on the filter housing for damage.
Replace, if necessary.
6. Make sure that the order number on the spare
element corresponds to the order number of the
filter name-plate. To ensure no contamination
occurs during the exchange of the element
first open the plastic bag and push the element
over the spigot in the filter head. Now remove
plastic bag.
7. Lightly lubricate the thread of the filter housing
and screw onto the filter head completely. After
that unscrew the filter housing 1/8 to 1/2 return.
8. T o refill the filter chamber, operate only the
pressure equalizing lever (leave the switching
lever arrested in its catch) long enough for
the medium to emerge bubble- free from the
vent bore.
9. Tighten vent screw. Check filter for leaks by
operating the pressure equalizing lever once
again.
Spare parts list
Order Numbers for spare parts

Position Description Order-Number


Element NG 100, 3µm FDAE3A02QH
Element NG 100, 10µm FDAE3A10QH
Element NG 160, 3µm FDBE1A02QH
Element NG 160, 10µm FDBE1A10QH
6
Element NG 250, 3µm FDBE2A02QH
Element NG 250, 10µm FDBE2A10QH
Element NG 400, 3µm FDBE3A02QH
Element NG 400, 10µm FDBE3A10QH
Sealing Kit
Sealing Kit FDP350N010 ZKF99-00000025
Kit 1-3 Sealing Kit FDP315N016 ZKF99-00000026
Sealing Kit FDP315N025 ZKF99-00000026
Sealing Kit FDP315N040 ZKF99-00000026
Maintenance indicator, complete unit
4+5
2 Switch points S3155-50 ZKF99-00000030
Maintenance Indicator, only electrical unit
5
2 Switch points S3155-50 ZKF99-00000033

© 2010 Parker Hannifin Corporation. Alle Rechte vorbehalten. SCG FDP315/UK/2011

Parker Hannifin GmbH


Pat-Parker-Platz 1
D-41564 Kaarst
Tel.: +49 (0)2131 4016 0
Fax: +49 (0)2131 4016 9199
www.parker.com Ihr Parker-Handelspartner

You might also like