You are on page 1of 4

Spec. No.

4823-DS-2260
DATA SHEET FOR Prep MYI Chk. DF Apr PR
SLOP OIL STORAGE TANKS Date 28-Jan-10
Sheet 1 of 1 Rev. 0

GENERAL INFORMATION (TO BE COMPLETED BY PURCHASER)

1 Purchaser/Agent ENAR PETROTECH SERVICES (PVT.) LTD. ###


City Karachi State Pakistan Zip Code 74900 Phone
2 User
3 Erection Site Name of Plant EPRF -II vol
Location Karachi ###
4 Tank No. T-506 Roof Type ###
5 Design Capacity 2,500 bbl Working Capacity 2,200 bbl
6 Pumping Rates In 150 GPM Out 150 GPM
7 Maximum Operating Temp. 50 ºC
8 Product Stored Slop Oil Design Sp. Gravity 0.77 At 15 ºC
9 Design Metal Temperature ºC R. Vapor Pressure 9 psi
10 Corrosion Allowance Shell 1/16" (1.6mm) Roof 1/16" (1.6mm)
Bottom 1/16" (1.6mm) Structurals _
11 Shell Design  Basic Standard 650  Appendix A  Appendix F
Design Pressure lbs/in²
12 Roof Design  Basic Standard 650  Appendix C (External Floating)
 Appendix G (Aluminum Dome)  Appendix H (Internal Floating)
Frangible Roof Joint?  Yes  No
13 Roof Design Information
14 Uniform Live Load lbs/ft²
15 Special Loads (Provide Sketch) lbs/ft²
16 Insulation Load lbs/ft²
17 Maximum Design Roof Temp. ºC
18 Gases in the Vapor Space Hydrocarbon Vapors
19 Earthquake Design?  Yes  No (Appendix E) Roof Tie Rods (3.10.4.5)?  Yes  No.
Seismic Zone 2A Importance Factor 1.0
Zone Factor (Table E-2) 0.15 Site Coefficient (Table E-3) 1.5
20 Wind Load Velocity 100 (160 km/hr.) miles/hr.
Provide Intermediate Wind Grider (3.9.7)?  Yes  No.
21 Envoronmental Effects Maximum Rainfall 2 inches/hr
Total Snow Accumulation - inches
22 Size Restrictions Maximum Diameter Maximum Height
23 Foundation Type  Earth  Concrete Ringwall  Other

REMARKS

1. Net working capacity of the tank is execlusive of dead stock and space above liquid surface due to pontoon height.
2. Check wind girder requirement based on shell thicknesses exclusive of corosion allowance.
3. Epoxy coat on tank bottom interior and shell interior upto 2m height.
4. Connections for side entry mixers to be provided.
5. Clean outdoor to be provided.
6. Manufacturer to fill in the Data Sheet.
7. Bottom (underside) of storage tanks cathodically protected, inside bottom shall be protected by sacrificial anodes.
Spec. No. 0880-SA-7552
DATA SHEET FOR Prep. by SMS Apr. by NMC
CRUDE STORAGE TANKS Date 30/10/1998
Sheet 2 of 3 Rev. 1

CONSTRUCTION DETAILS (TO BE COMPLETED BY MANUFACTURER AND/OR PURCHASER)

1 Manufacturer
Address
City State Zip Code Phone
Serial No.
2 Fabricator
Address
City State Zip Code Phone
Serial No.
3 Material Specifications: Shell
Roof
Bottom
Structurals
4 No of Shell Courses
5 Plate Wdiths, Length and Thickness (including Corrosion Allowance), in inches:
1) 4) 7)
2) 5) 8)
3) 6) 9)
6 Tank Bottom Plate Thickness: inches  Lap  But Seams
Slope 1 : 120  To  From Centre
7 Minimum Width and Thickness of Bottom Annular Plates (3.5), in inches:
8 Roof-to-Shell Detail (Figure-1)
9 Intermediate Wind Girder?  Yes  No Top Wind Girder for Use as Walkway?  Yes  No
10 Roof Type  Supported  Self-supported  Floating
Slope or Radius mm
11 Roof Plate Thickness mm  Lap  Butt  Joint
12 Paint
- Shell Exterior?  Yes  No Interior?  Yes  No
Surface Preparation Sand Blasting - SA 2.5 (Inside Lower Portion - 2m)
- Bottom Underside?  Yes  No Interior?  Yes  No
Surface Preparation Sand Blasting - SA 2.5
- Structural Steel Exterior?  Yes  No Interior?  Yes  No
Specification Sand Blasting - SA 2.5
13 Tank Bottom Coating Interior?  Yes  No Material
Application Specification
14 Inspection By Shop Owner Field Owner
15 Weld Examination Radiograph Yes
Supplementary Liquid Penetrant or Ultrasonic
16 Films Provided by Contractor Property of Owner
17 Leak Testing Bottom Yes Roof Yes
Shell Yes
18 Mill Test Reports Required?  Yes  No
Plate Yes Structural Shapes Yes
19 Purchaser's Reference Drawing
20 Tank Size Diameter 140 ft. (42.68m) Height 48 ft. (14.63m)
21 Date of Standard 650 Edition/Revision Latest
REMARKS
Spec. No. 0880-SA-7552
DATA SHEET FOR Prep. by SMS Apr. by NMC
CRUDE STORAGE TANKS Date 30/10/1998
Sheet 3 of 3 Rev. 1

APPURTENANCES (TO BE COMPLETED BY MANUFACTURER AND/OR PURCHASER)

1 Stairway Style  Circular  Straight Angle to Horizontal 45 Degrees


Ladder
2 Walkway Width 1,000 mm Length ft.
3 Drawoff Sump Standard Yes Special
4 Bolted Door Sheet?  Yes  No (Appendix A Tanks Only)  Raised  Flush
5 Scaffold Hitch Yes
6 Internal Piping Swing Line Suction Line
Heating Coil Surface Area ft 2

7 Roof Drain Hose Jointed


Siphon
8 No. and Size of Shell Manholes 3 Nos. 24" Dia.
9 No. and Size of Roof Manholes 3 Nos. 24" Dia.
10 Shell Nozzles (See Figures 3.4B, 3.5 and 3.7 and Tables 3.8, 3.9 and 3.10):

FLANGED THREADED ORIENTATION HEIGHT FROM


MARK SIZE SERVICE
SGL DBL SPL A B C D E N=O BOTTOM

2 × 20" Product Inlet/Outlet


2 × 4" Refer Drawing No. 4790-PB-101 Per API 650 Water Draw-off
1½" Thermowell Coupling

11 Roof Nozzles, including Venting Connection (See Figures 3.14 and 3.15 and Tables 3.16 and 3.17):

REINFORCMEN ORIENTATION DISTANCE


MARK SIZE FLANGED THREADED SERVICE
T N=O FROM CENTER

Gauge Hatch
Refer Drawing No. 4790-PB-101 Tank Gauging
System
Temp Sensor

NOTE: Sketches and/or separate sheets may be attached to cover special requirements.