BP OIL CO.

ATMOSPHERIC RP11-1-1 DS
STORAGE TANKS Page 1 of 6
REFINING PRACTICE
DATA SHEET Rev. 1 Dec. 1997

PROJECT PROJECT NO. INQUIRY NO.

LOCATION UNIT

EQUIPMENT ID JOB NO. DOCUMENT NO.

DATA ISSUED FOR: j IN-HOUSE REVIEW j BP OIL APPROVAL j QUOTATION

j PURCHASE j CONSTRUCTION j

THIS SHEET IS A RECORD OF EACH ISSUE OR REVISION TO THE SUBJECT DATA. EACH TIME THE DATA IS j ALL DATA SHEETS ATTACHED
CHANGED ONLY THE NEW OR REVISED DATA SHEETS NEED TO BE ISSUED. THE EXACT SHEETS CHANGED
AND THE NATURE OF THE CHANGE SHOULD BE NOTED UNDER REMARKS. THESE REMARKS ARE NOT A
j REVISED DATA SHEET(S) ONLY
PART OF THE DATA. THE REVISED DATA SHEET(S) BECOME PART OF THE ORIGINAL DATA AND SHALL BE
ATTACHED
COMPLIED WITH IN THEIR ENTIRETY.

REV. DATE BY CHECK APPROVALS REMARKS

SECTION PROJECT BP OIL

BPOUS Engineering Services – Cleveland, Ohio


BP OIL CO. ATMOSPHERIC RP11-1-1 DS
STORAGE TANKS Page 2 of 6
REFINING PRACTICE
DATA SHEET Rev. 1 Dec. 1997

EQUIPMENT ID JOB NO. DOCUMENT NO. REV.

GENERAL INFORMATION
1. PURCHASER/AGENT
ADDRESS
CITY STATE ZIP PHONE
2. USER
3. ERECTION SITE: NAME OF PLANT
LOCATION
4. TANK NO. NOMINAL CAPACITY BARRELS NET WORKING CAPACITY BARRELS
5. PUMPING RATES: IN BARRELS/HOUR OUT BARRELS/HOUR
6. MAXIMUM OPERATING TEMPERATURE °F
7. PRODUCT STORED DESIGN SPECIFIC GRAVITY AT °F
DESIGN METAL TEMPERATURE °F VAPOR PRESSURE INCHES OF WATER
8. CORROSION ALLOWANCE SHELL INCHES ROOF INCHES
BOTTOM INCHES STRUCTURALS INCHES
9. SHELL DESIGN: j BASIC STANDARD 650 j APPENDIX A j APPENDIX F
DESIGN INTERNAL PRESSURE POUNDS/SQUARE INCH
10. ROOF DESIGN: j BASIC STANDARD 650 j APPENDIX C (EXTERNAL FLOATING) j APPENDIX H (INTERNAL FLOATING)
FRANGIBLE ROOF JOINT? j YES j NO j
APPENDIX G (ALUMINUM DOME)
11. ROOF DESIGN INFORMATION: UNIFORM LIVE LOAD POUNDS/SQUARE FOOT
SPECIAL LOADS (PROVIDE SKETCH) POUNDS/SQUARE FOOT
INSULATION LOAD POUNDS/SQUARE FOOT
MAXIMUM DESIGN ROOF TEMPERATURE °F GASES IN THE VAPOR SPACE
12. EARTHQUAKE DESIGN? j YES j NO (APPENDIX E) ROOF TIE RODS (3.10.4.5)? j YES j NO
SEISMIC ZONE (FIGURE (E-1) ESSENTIAL FACILITIES FACTOR
ZONE COEFFICIENT (TABLE E-1) SITE AMPLIFICATION FACTOR (TABLE E-2)
13. WIND LOAD: VELOCITY MILES/HOUR
PROVIDE INTERMEDIATE WINDGIRDER (3.9.7)? j YES j NO
14. ENVIRONMENTAL EFFECTS: MAXIMUM RAINFALL INCHES/HOUR TOTAL SNOW ACCUMULATION INCHES
15. SIZE RESTRICTIONS: MAXIMUM DIAMETER FEET MAXIMUM HEIGHT FEET
16. FOUNDATION TYPE: j EARTH j CONCRETE RINGWALL j OTHER
PREDICTED SETTLEMENT 10 YRS 25 YRS
REMARKS

BPOUS Engineering Services – Cleveland, Ohio


BP OIL CO. ATMOSPHERIC RP11-1-1 DS
STORAGE TANKS Page 3 of 6
REFINING PRACTICE
DATA SHEET Rev. 1 Dec. 1997

EQUIPMENT ID JOB NO. DOCUMENT NO. REV.

CONSTRUCTION DETAILS
1. MANUFACTURER
ADDRESS
CITY STATE ZIP PHONE
SERIAL NO.
2. FABRICATOR
ADDRESS
CITY STATE ZIP PHONE
3. MATERIAL SPECIFICATIONS: SHELL
ROOF
BOTTOM
STRUCTURALS
4. NO. OF SHELL COURSES
5. PLATE WIDTHS AND THICKNESSES (INCLUDING CORROSION ALLOWANCES):
1. 4. 7.
2. 5. 8.
3. 6. 9.

6. TANK BOTTOM: PLATE THICKNESS INCHES j LAP j BUTT SEAMS


SLOPE INCH PER FOOT j TO j FROM CENTER
7. MINIMUM WIDTH AND THICKNESS OF BOTTOM ANNULAR PLATES (3.5)
8. ROOF-TO-SHELL DETAIL (FIGURE F-1)
9. INTERMEDIATE WINDGIRDER? j YES j NO TOP GIRDER FOR USE AS WALKWAY? j YES j NO
10. ROOF TYPE: j SUPPORTED j SELF–SUPPORTED j FLOATING
SLOPE OR RADIUS INCHES
11. ROOF PLATE: THICKNESS: INCHES j LAP j BUTT JOINT
12. PAINT:
SHELL— EXTERIOR? j YES j NO INTERIOR? j YES j NO
SURFACE PREPARATION
BOTTOM— UNDERSIDE? j YES j NO INTERIOR? j YES j NO
SURFACE PREPARATION
STRUCTURAL STEEL— EXTERIOR? j YES j NO INTERIOR? j YES j NO
SPECIFICATION
13. TANK BOTTOM COATING: INTERIOR? j YES j NO MATERIAL
APPLICATION SPECIFICATION
14. INSPECTION BY: SHOP FIELD
15. WELD EXAMINATION: RADIOGRAPH
SUPPLEMENTARY LIQUID PENETRANT OR ULTRASONIC
16. FILMS PROPERTY OF
17. LEAK TESTING BOTTOM ROOF
SHELL
18. MILL TEST REPORTS: REQUIRED? j YES j NO
PLATE STRUCTURAL SHAPES

BPOUS Engineering Services – Cleveland, Ohio


BP OIL CO. ATMOSPHERIC RP11-1-1 DS
STORAGE TANKS Page 4 of 6
REFINING PRACTICE
DATA SHEET Rev. 1 Dec. 1997

EQUIPMENT ID JOB NO. DOCUMENT NO. REV.

CONSTRUCTION DETAILS

19. PURCHASER’S REFERENCE DRAWING


20. TANK SIZE: DIAMETER FEET HEIGHT FEET
21. DATE OF STANDARD 650 EDITION/REVISION
REMARKS:

BPOUS Engineering Services – Cleveland, Ohio


BP OIL CO. ATMOSPHERIC RP11-1-1 DS
STORAGE TANKS Page 5 of 6
REFINING PRACTICE
DATA SHEET Rev. 1 Dec. 1997

EQUIPMENT ID JOB NO. DOCUMENT NO. REV.

APPURTENANCES

1. STAIRWAY STYLE: j CIRCULAR j STRAIGHT ANGLE TO HORIZONTAL DEGREES


LADDER
2. WALKWAY: WIDTH INCHES LENGTH FEET
3. DRAWOFF SUMP: STANDARD SPECIAL
4. BOLTED DOOR SHEET: j YES j NO (APPENDIX A TANKS ONLY) j RAISED j FLUSH
5. SCAFFOLD HITCH
6. INTERNAL PIPING: SWING LINE SUCTION LINE
HEATING COIL SURFACE AREA SQUARE FEET
7. ROOF DRAIN: HOSE JOINTED
SIPHON
8. NO. AND SIZE OF SHELL MANWAYS
9. NO. AND SIZE OF ROOF MANWAYS
10. SHELL NOZZLES AND MANWAYS (SEE FIGURES 3–4A, 3–4B, 3–5, AND 3–6 AND TABLES 3–3, 3–4, 3–5, 3–6, 3–7, 3–8, 3–9, AND 3–10 OF API 650):

FLANGED (1)

ORIENTATION HEIGHT SERVICE


N=0 FROM
MARK SIZE SGL DBL SPL
BOTTOM

NOTE:
(1) SGL, DBL, AND SPL designate single, double, and special flange designs as given in API 650, Figure 3.5. Note that
nozzle weld details shall be in accordance with the requirements of this Practice.

BPOUS Engineering Services – Cleveland, Ohio


BP OIL CO. ATMOSPHERIC RP11-1-1 DS
STORAGE TANKS Page 6 of 6
REFINING PRACTICE
DATA SHEET Rev. 1 Dec. 1997

EQUIPMENT ID JOB NO. DOCUMENT NO. REV.

APPURTENANCES

11. ROOF NOZZLES, INCLUDING VENTING CONNECTION (SEE FIGURES 3–12, 3–13 AND 3–14 AND TABLES 3–16 AND 3–17 OF API 65):

MARK SIZE TYPE REINFORCEMENT ORIENTATION DISTANCE SERVICE


N=0 FROM CENTER

12. NOTE: SKETCHES AND/OR SEPARATE SHEETS MAY BE ATTACHED TO COVER SPECIAL REQUIREMENTS.

13. REMARKS: