ADXL202/ADXL210

9 14
CFILT = 0.01mF T2 = 1ms
8
12 BW = 500Hz
7
PERCENTAGE OF SAMPLES

CFILT = 0.047mF
10

TOTAL RMS NOISE – mg


6 BW = 100Hz

8 CFILT = 0.1mF
5
BW = 50Hz
4
6 CFILT = 0.47mF
BW = 10Hz
3
4
2

1 2

0 0
11.3 11.5 11.7 11.9 12.2 12.4 12.6 12.8 13.1 13.3 13.5 13.7 1 4 16 64
DUTY CYCLE OUTPUT – % per g NUMBER OF AVERAGE SAMPLES

Figure 8. Typical Sensitivity per g at +25 °C Figure 10. Typical Noise at Digital Outputs

14 20

18
12
16
TOTAL RMS NOISE – mg

10 14

% OF PARTS
12
8
10

6 8

6
4
4
2
2

0 0

–0.0125

0.0125
–1.375

–1.125

–0.875

–0.625

–0.375

0.375

0.625

0.875

1.125

1.375
0.01mF 0.047mF 0.1mF 0.47mF
500Hz 100Hz 50Hz 10Hz
CX, CY
BANDWIDTH DEGREES OF MISALIGNMENT

Figure 9. Typical Noise at XFILT Output Figure 11. Rotational Die Alignment