You are on page 1of 6

SD2000 | 65.

4L | 2,000 kW
INDUSTRIAL DIESEL GENERATOR SET
EPA Certified Stationary Emergency

Standby Power Rating


2,000 kW, 2,500 kVA, 60 Hz

Prime Power Rating*


1,800 kW, 2,250 kVA, 60 Hz

*Assembled in the USA using


domestic and foreign parts

*EPA Certified Prime ratings are not available in the US or its Territories
Image used for illustration purposes only

Codes and Standards Powering Ahead


Not all codes and standards apply to all configurations. Contact
factory for details. For over 50 years, Generac has provided innovative design and
superior manufacturing.
UL2200, UL508, UL489, UL142
Generac ensures superior quality by designing and manufacturing
most of its generator components, including alternators, enclosures
CSA 22.2 and base tanks, control systems and communications software.

Generac gensets utilize a wide variety of options, configurations and


BS5514 and DIN 6271
TM

arrangements, allowing us to meet the standby power needs of


practically every application.
SAE J1349
® Generac searched globally to ensure the most reliable engines power
our generators. We choose only engines that have already been
NFPA 37, 70, 99, 110 proven in heavy-duty industrial applications under adverse
conditions.
®
NEC700, 701, 702, 708 Generac is committed to ensuring our customers’ service support
continues after their generator purchase.

ISO 3046, 7637, 8528, 9001

NEMA ICS10, MG1, 250, ICS6, AB1


SPEC SHEET

ANSI C62.41

IBC 2009, IBC 2012,


ASCE 7-05, ASCE 7-10, ICC-ES AC-
156 (2012) 1 of 6
SD2000 | 65.4L | 2,000 kW
INDUSTRIAL DIESEL GENERATOR SET
EPA Certified Stationary Emergency

STANDARD FEATURES

ENGINE SYSTEM ALTERNATOR SYSTEM TANKS (If Selected)


• Oil Drain Extension • Class H Insulation Material • UL 142
• Air Cleaner • 2/3 Pitch • Double Wall
• Fan Guard • Skewed Stator • Vents
• Stainless Steel Flexible Exhaust Connection • Permanent Magnet Excitation • Factory Pressure Tested (2 psi)
• Factory Filled Oil and Coolant • Sealed Bearing • Rupture Basin Alarm
• Radiator Duct Adapter (Open Set Only) • Full Load Capacity Alternator • Fuel Level
• Check Valve In Supply and Return Lines
Fuel System GENERATOR SET • Stainless Steel Hardware
• Flexible Fuel Lines (When Tank is Selected) • Separation of Circuits - High/Low Voltage • Fuel Line Hose
• Primary Fuel Filter • Separation of Circuits - Dual Breakers • Fuel Line Hose and Separator
• Standard Factory Testing • Electric Fuel Level
Cooling System • 2 Year Limited Warranty (Standby Rated Units) • Secondary Fuel Filter

• Closed Coolant Recovery System • 1 Year Limited Warranty (Prime Rated Units)
• UV/Ozone Resistant Hoses
• Factory-Installed Radiator ENCLOSURE (If Selected)
• Radiator Drain Extension • Structural Steel Sub-Base
• 50/50 Ethylene Glycol Antifreeze • Sub-Base Lifting Eyes
• Enamel Finish
Electrical System • Zinc Plated Fasteners
• Battery Charging Alternator • Zinc Plated Cast Aluminum Keylock Door Handles
• Battery Cables • Heavy Duty Stainless Steel Hinges with Removable
• Battery Tray Brass Pins
• Rubber-Booted Engine Electrical Connections • Modular Construction
• Solenoid Activated Starter Motor

CONTROL SYSTEM • Not in Auto (Flashing Light) • Engine Speed


• Auto/Off/Manual Switch • Battery Voltage
• Customizable Alarms, Warnings, and Events • Frequency
• Modbus® Protocol
• Predictive Maintenance Algorithm Alarms and Warnings
• Sealed Boards • Oil Pressure
• Password Parameter Adjustment Protection • Coolant Temperature
• Single Point Ground • Coolant Level
• 16 Channel Remote Trending • Engine Overspeed
• 0.2 msec High Speed Remote Trending • Battery Voltage

InteliGen NT Display • Alarm Information Automatically Annunciated • Alarms and Warnings Time and Date Stamped
on the Display • Snap Shots of Key Operation Parameters During
Program Functions Alarms and Warnings
Full System Status Display •
• Programmable Crank Limiter Alarms and Warnings Spelled Out (No Alarm Codes)
• 7-Day Programmable Exerciser
• Power Output (kW)

• Special Applications Programmable Logic Controller


• Power Factor
SPEC SHEET

• RS-232/485 Communications
• kW Hours, Total, and Last Run

• 2-Wire Start Capability


• Real/Reactive/Apparent Power

• Date/Time Fault History (Event Log)


• All Phase AC Voltage

• Isochronous Governor Control


• All Phase Currents

• Waterproof/Sealed Connectors
• Oil Pressure

• Audible Alarms and Shutdowns


• Coolant Temperature 2 of 6
• Coolant Level
SD2000 | 65.4L | 2,000 kW
INDUSTRIAL DIESEL GENERATOR SET
EPA Certified Stationary Emergency

CONFIGURABLE OPTIONS

ENGINE SYSTEM GENERATOR SET CONTROL SYSTEM


○ 50° Ambient Cooling System ○ AC Electrical Lighting Package (ELP) ○ NFPA110 Level I and II (Programmable)
○ Critical and Hospital Grade Silencers ○ Spring Isolators (Standard/Seismic) ○ 15- LED Remote Annunciator
○ CCV (Crankcase Ventilation) ○ Remote Relay Assembly (8 or 16)
ENCLOSURE ○ Remote E-Stop - Surface Mount
ELECTRICAL SYSTEM ○ Weather Protected Enclosure
○ Local E-Stop Panel

○ Level 1 Sound Attenuation


○ Remote Communication - InternetBridge NT
○ 10A UL Battery Charger ○ 10A Run Relay, 12 outputs
○ ○ Level 2 Sound Attenuation
20 A UL Battery Charger
○ Steel Enclosure
○ Low Coolant Level Indication
○ Battery Warmer ○ 90% Alarm High Fuel Program
○ Aluminum Enclosure
ALTERNATOR SYSTEM ○ Up to 200 MPH Wind Load Rating (Contact Factory
for Availability) TANKS (Size On Last Page)
○ Alternator Upsizing ○ Louvers with Gravity Dampers ○ Mechanical Fuel Level
○ Anti-Condensation Heater ○ Enclosure Heaters ○ 12 Hour Run Time
○ 24 Hour Run Time
CIRCUIT BREAKER OPTIONS WARRANTY (Standby Gensets Only)
○ Main Line Circuit Breaker ○ 2 Year Extended Limited Warranty
○ 2nd Main Line Circuit Breaker ○ 5 Year Limited Warranty
○ Shunt Trip and Auxiliary Contact ○ 5 Year Extended Limited Warranty
○ Electronic Trip Breakers ○ 7 Year Extended Limited Warranty
○ 10 Year Extended Limited Warranty

ENGINEERED OPTIONS

ENGINE SYSTEM CONTROL SYSTEM ENCLOSURE


○ Coolant Heater Ball Valves ○ Spare Inputs (x4) / Outputs (x4) ○ Intrusion Alert Door Switch
○ Oil Heater ○ Battery Disconnect Switch ○ Level 3 Enclosure
○ Fuel Cooler ○ PM-SCi ○ Custom Enclosure
○ High Lift Pumps
○ Heavy Duty Air Filters (Open Units Only) GENERATOR SET TANKS
○ Special Testing ○ Overfill Protection Valve
ALTERNATOR SYSTEM ○ 12 VDC Enclosure Lighting Kit ○ UL2085 Tank
○ 3rd Breaker System ○ 24 VDC/120 VAC Enclosure Lighting Kit ○ ULC S-601 Tank
○ Unit Mounted Load Banks ○ Special Fuel Tanks
○ Medium Voltage Alternators ○ External Vent Extensions
○ 4th Breaker Options ○ Transfer Pumps and Controllers
○ Digital Voltage Regulator ○ Fuel Tank Heaters
SPEC SHEET

3 of 6
SD2000 | 65.4L | 2,000 kW
INDUSTRIAL DIESEL GENERATOR SET
EPA Certified Stationary Emergency

APPLICATION AND ENGINEERING DATA

ENGINE SPECIFICATIONS

General Cooling System

Make Mitsubishi Cooling System Type Unit Mounted Radiator


EPA Emissions Compliance Tier 2 Water Pump Type Centrifugal
EPA Emissions Reference See Emission Data Sheet Fan Type Pusher
Cylinder # 16 Fan Speed - RPM 710
Type 4 Cycle Fan Diameter - in (mm) 88 (2,235)
Displacement - in3 (L) 3,989 (65.4)
Bore - in (mm) 6.69 (170)
Fuel System
Stroke - in (mm) 7.09 (180) Fuel Type Ultra Low Sulfur Diesel #2
Compression Ratio 14.0:1 Fuel Specifications ASTM
Intake Air Method Turbocharged/Intercooled Fuel Filtering (Microns) 10 (Final Filters)
Cylinder Head 4-Valve Fuel Inject Pump Make Mechanical
Piston Type Aluminum Fuel Pump Type Engine Driven Gear
Crankshaft Type Dropped Forged Steel Injector Type Mitsubishi PS8 Type x 2
Engine Type S16R-Y2PTAW2-1
Engine Governing Fuel Supply Line - in (mm) 1” NPT (25.4)
Governor Electronic Fuel Return Line - in (mm) 1” NPT (25.4)
Frequency Regulation (Steady State) ±0.25%
Engine Electrical System
Lubrication System System Voltage 24 VDC
Oil Pump Type Gear Battery Charger Alternator Standard
Oil Filter Type Cartridge Battery Size See Battery Index 0161970SBY
Crankcase Capacity - qt (L) 212 (200) Battery Voltage (2) - 12 VDC
Ground Polarity Negative

ALTERNATOR SPECIFICATIONS

Standard Model K2112064N22 Standard Excitation Permanent Magnet


Poles 4 Bearings Single Sealed Cartridge
Field Type Rotating Coupling Direct via Flexible Disc
Insulation Class - Rotor H Load Capacity- Standby 100%
Insulation Class - Stator H Prototype Short Circuit Test Yes
Total Harmonic Distortion <5% Voltage Regulator Type Analog
Telephone Interference Factor (TIF) < 50 Regulation Accuracy (Steady State) ±0.5%
SPEC SHEET

4 of 6
SD2000 | 65.4L | 2,000 kW
INDUSTRIAL DIESEL GENERATOR SET
EPA Certified Stationary Emergency

OPERATING DATA

POWER RATINGS

Standby
Three-Phase 277/480 VAC @0.8pf 2,000 kW Amps: 3,007
Three-Phase 346/600 VAC @0.8pf 2,000 kW Amps: 2,406

STARTING CAPABILITIES (sKVA)


sKVA vs. Voltage Dip
K2112064N22 K2268064N22
480 VAC at 30% 7709 9417

FUEL CONSUMPTION RATES*


Diesel - gph (lph)
Fuel Pump Lift- ft (m) Percent Load Standby
3 (1) 25% 38.6 (146.0)
50% 72.1 (272.8)
Total Fuel Pump Flow (Combustion + Return) - gph (lph) 75% 107.2 (405.6)
148 (560) 100% 146.7 (555.3)
* Fuel supply installation must accommodate
fuel consumption rates at 100% load.

COOLING
Cooling Rating- Jacket Water Standby Cooling Rating- Aftercooler Standby
Coolant Flow gpm (Lpm) 489 (1,851) Coolant Flow gpm (Lpm) 243 (920)
Coolant System Capacity gal (L) 106 (401) Coolant System Capacity gal (L) 65 (246)
Heat Rejection to Coolant BTU/min (kW) 44,374 (13)
Inlet Air- 40°C Cooling Package cfm (m3/min) 101,400 (2,872) Cooling Rating- Fuel Pump Standby
Inlet Air- 50°C Cooling Package cfm (m3/min) 100,700 (2,852) Heat Rejected to Fuel BTU/min (kW) 54,350 (16)
Max. Operating Ambient Temp °F (°C) 122 (50)
Max Operating Ambient Temperature
see Bulletin No. 0199270SSD
(Before Derate)
Maximum Radiator Backpressure in H2O (kPa) 0.5 (0.12)

COMBUSTION AIR REQUIREMENTS


Standby
Flow at Rated Power cfm (m3/min) 7,274 (206)

ENGINE EXHAUST
Standby Standby
Rated Engine Speed RPM 1,800 Exhaust Flow (Rated Output) cfm (m3/min) 19,209 (544)
Horsepower at Rated kW** hp 2,923 Max. Allowable Backpressure inHg (kPa) 1.7 (5.87)
Piston Speed ft/min (m/min) 2,126 (648) Exhaust Temp (Rated Output - Post Silencer) °F (°C) 932 (500)
BMEP psi (kPa) 323 (2,227)
SPEC SHEET

** Refer to “Emissions Data Sheet” for maximum bHP for EPA and SCAQMD permitting purposes.

Deration – Operational characteristics consider maximum ambient conditions. Derate factors may apply under atypical site conditions.
Please contact a Generac Power Systems Industrial Dealer for additional details. All performance ratings in accordance with ISO3046, BS5514, ISO8528, and DIN6271 standards.
Standby - See Bulletin 10000018933
Prime - See Bulletin 10000018926

5 of 6
SD2000 | 65.4L | 2,000 kW
INDUSTRIAL DIESEL GENERATOR SET
EPA Certified Stationary Emergency

DIMENSIONS AND WEIGHTS*

OPEN SET (Includes Exhaust Flex)


Usable
Run Time - Weight
Capacity L x W x H - in (mm)
Hours - lbs (kg)
- Gal (L)
No Tank - 241.9 (6,145) x 106.8 (2,712) x 123.5 (3,136) Contact Factory
12 1,925 (7,287) 274.5 (6,972) x 120.0 (3,048) x 150.1 (3,812) Contact Factory
24 3,850 (14,574) 274.5 (6,972) x 120.0 (3,048) x 168.1 (4,270) Contact Factory

STANDARD ENCLOSURE**
Usable
Run Time - Weight
Capacity L x W x H - in (mm)
Hours - lbs (kg)
- Gal (L)
No Tank - 266.5 (6,769) x 122.0 (3,099) x 185.3 (4,706) Contact Factory
12 1,925 (7,287) 275.5 (6,997) x 122.0 (3,099) x 196.3 (4,985) Contact Factory
24 3,850 (14,574) 275.5 (6,997) x 122.0 (3,099) x 214.3 (5,443) Contact Factory

LEVEL 1 ACOUSTIC ENCLOSURE**


Usable
Run Time - Weight
Capacity L x W x H - in (mm)
Hours - lbs (kg)
- Gal (L)
No Tank - 373.0 (9,474) x 122.0 (3,099) x 185.3 (4,706) Contact Factory
12 1,925 (7,287) 381.7 (9,669) x 122.0 (3,099) x 206.3 (5,239) Contact Factory
24 3,850 (14,574) 381.7 (9,669) x 122.0 (3,099) x 218.3 (5,544) Contact Factory

LEVEL 2 ACOUSTIC ENCLOSURE**


Usable
Run Time - Weight
Capacity L x W x H - in (mm)
Hours - lbs (kg)
- Gal (L)
No Tank - 445.4 (11,312) x 267.1 (6,785) x 185.3 (4,706) Contact Factory
12 1,925 (7,287) 445.4 (11,312) x 267.1 (6,785) x 206.3 (5,239) Contact Factory
24 3,850 (14,574) 445.4 (11,312) x 267.1 (6,785) x 218.3 (5,544) Contact Factory

* All measurements and weights are approximate and for estimation purposes only.

YOUR FACTORY RECOGNIZED GENERAC INDUSTRIAL DEALER


SPEC SHEET

Specification characteristics may change without notice. Please contact a Generac Power Systems Industrial Dealer for detailed installation drawings.

6 of 6

Generac Power Systems, Inc. | P.O. Box 8 | Waukesha, WI 53189 Part No. 10000031559
P: (262) 544-4811 ©2018 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Rev. A 03/15/18

You might also like