You are on page 1of 1

● Run CPU

TCD - 088 C1ST CTT ON DEFECT


Point of Application ● DI120-150
Detection ○ Speed CPU ● DI180-420
[Meaning]
[Actions to take]
When C1ST does not turn ON within 500ms after C1ST ON command
is outputted from Run CPU. 1. Check the power status of C110 and P48.

2. Check C1ST coil and auxiliary contact for screw


connection status.
Check the connection status of RC connected to C1ST
coil body.

[Diagram] 3. Check the connection and contact status of C1ST


GD operation circuit(Drawing3x02223).
Refer to 3x02223, CTL C[8] OS_C1ST
0x530C 4. Check the connection and contact status of C1ST
C110 D110 auxiliary circuit(Drawing3x02227).
R5SC R2LD STR1-08 DOR-230 DOR-230 RCC-14 A2
C1VD C A1
12
C1ST 5. Check TCD88.
8 9 5 53 54
CTT-01 CTT-02
DOR-210 PCB 1)Turn ON C1ST by force and check the input buffer(0x501F)
data. If there’s no changes found, try replacing
DOR-230 PCB.
Refer to 3x02227, I/O C[1] 2)If input signal is normal, DOR-230 PCB output buffer
P48 GD48 may be inferior.
RCA-08 DOR-230 3)If the problem exists even after replacing PCB, it may
C1ST C IS_C1ST
be coming from C1ST self defect.
13 14 0x501F
INA-15
6. Check TCD89.

Perform check by the opposite way of above item 5.


If TCD89 occurs even though C1ST OFF operation is normal,
try increasing OFF DELAY TIMER value above 500ms.
If TCD89 does not occurs by this action, C1ST OFF’s
characteristic inferior.