You are on page 1of 9

Part: : TCD Code

Di1(Si210) Elevator / Trouble Shooting


Shoo ting Ctrl No. : SI-TS-02-2
Page: 40/117

○ Operation CPU
TCD 70
70 48V Power Trouble Detection Application Si210
○ Speed CPU

[Meaning ] This is the method that detects any possible lost phase of E/L three-phase [Countermeasures ]
input power. The decision is carried out by checking the DC rectifying
voltage(DC 48V) in the c ontrolling power three-phase AC37V. 1. Verify that D48 FUSE LED(LED3.LED4) in DOP-116
PCB lights on.

[Explanation ] 2. Check the fuse(FS3, FS4) when the above LED lights off. I f it
If IALM(red) LED and P.F(red) LED lights up on DOC-131,
operation will be unable. is disconnected, replace it with a rated fuse(250V/3A).
3. If any error are not found at the above items, verify that the

V48_Down_Count >5 voltage AC 37V± 10% among pin 1, 9 and 12 of PB


TCD 70
connector in DOP-116 PCB BOARD.
4) Verify that the voltage between AB-10 pin in DOC-131 PCB
and F.G is DC48V± 10% .
Left picture below show DC 48V at a normal power and the right picture shows
wave form when a phase was lost.
Lost phase detecting circuit in DOC-131 lights ARM LED when it detects a wave
form which falls down 35V or less. If it detects such wave for 300msec, it makes
Error 70.

Voltage : DC48V±10% Voltage : DC32V±10%

[ Wave form & voltage on normal ] [ Wave form & voltage on abnormal ]
Part: : TCD Code
Di1(Si210) Elevator / Trouble Shooting
Shoo ting Ctrl No. : SI-TS-02-2
Page: 41/117

○ Operation CPU
TCD
TCD 71
71 Volta
oltage
ge Drop
Drop Dete
Detect
ctio
ion
n (ER
(ER_V
_V48
48)) Detection Application Si210
○ Speed CPU

[Meaning ] When input power(3 phases) drops to its 85% or below, [Countermeasures ]
the trouble occurs.
1. There is no special countermeasure.
Check the power source f rom the building.
2. Refer to countermeasures of TCD70.
[Explanation ] In case 85% of voltage drop continues for 90 msec, the trouble is
detected.
It is detected by the voltage(DC48V) rectified from AC37V that is
3 phases power for control.

Coil[SW_SS_48V_UNDER_85P] under_85p_count > 2


TCD 71

0x923F

+1 under_85p_count
Part: : TCD Code
Di1(Si210) Elevator / Trouble Shooting
Shoo ting Ctrl No. : SI-TS-02-2
Page: 42/117

○ Operation CPU
TCD 72 ER_C1SW_ON Detection Application Si210
○ Speed CPU

[Meaning ] C1SW ON condition lasts for over 540ms after C1SW OFF [Countermeasures ]
commanded.
1. Check the C1SW wiring according to drawing.
2. Refer to countermeasures of TCD88.
3. Replace C1SW contactor.
[Explanation ]

Coil[SW_SS_48V_
SWD_I[VI_C1SW] SWD_O[VO_C1ST] DOWN_HOLD] Check_out

0x8066 0x8081 0x923C

Coil[SV_INV_
SWD_I[VI_C1SW] SWD_O[VO_C1ST] 0x923D
SW_FAIL]

Coil[SW_SS_
0x8066 0x8081 0x9210 DSP_WD]

Check_out
TMC_Start(C1SW__
ERROR_DETECT_T)

TMC_Check(C1SW_ERROR SWD_I[V1_C1SW]
_DETECT_T,FINISH_STATE)
_DETECT_T,FINISH_STATE) TCD 72

0x802A
Part: : TCD Code
Di1(Si210) Elevator / Trouble Shooting
Shoo ting Ctrl No. : SI-TS-02-2
Page: 43/117

○ Operation CPU
TCD 73 ER_C1SW_OFF Detection Application Si210
○ Speed CPU

[Meaning ] C1SW OFF condition lasts for over 540ms after C1SW ON [Countermeasures ]
commanded.
1. Check the C1SW wiring according to drawing.
2. Refer to countermeasures of TCD89.
3. Replace C1SW contactor.
[Explanation ]

Coil[SW_SS_48V_
SWD_I[VI_C1SW] SWD_O[VO_C1ST] DOWN_HOLD] Check_out

0x8066 0x8081 0x923C

Coil[SV_INV_
SWD_I[VI_C1SW] SWD_O[VO_C1ST] 0x923D
SW_FAIL]

Coil[SW_SS_
0x8066 0x8081 0x9210 DSP_WD]

Check_out
TMC_Start(C1SW__
ERROR_DETECT_T)

TMC_Check(C1SW_ERROR SWD_I[V1_C1SW]
_DETECT_T,FINISH_STATE)
_DETECT_T,FINISH_STATE) TCD 89

0x802A

1. It detects an error when C1SW c ontact input is nothing even


C1SW contactor is turned on.
Part: : TCD Code
Di1(Si210) Elevator / Trouble Shooting
Shoo ting Ctrl No. : SI-TS-02-2
Page: 44/117

○ Operation CPU
TCD
TCD 74
74 Oper
Operat
atio
ion
n SPE
SPEC
C DA
DATA Troub
rouble
le Detection Application Si210
○ Speed CPU

[Meaning ] SPEC DATA trouble is detected in Operation CPU, [Countermeasures ]


when EEPROM SPEC DATA is not within controllable range. Inspect and correct the data of SPEC ROM(EEPROM
EEPROM-- 28C64
28C64).

Search corresponding address from the SPEC list, and then


[Explanation ] This trouble occurs when the value of SPEC DATA in EEPROM enter the address by pressing “A31E” on the Annunciator(ANN).
violates the setting. Correct the data value of corresponding address of EEPROM
and reset.
1. When the data is not
not gear-less type but designated
designated data.
2. Concerning gear type, the data of TR M/C is out of range. 1. Gear type (Address: 0106 H)
3. When the value of encoder is not 8192 P/R 2. TR M/C T ype (Address: 0108H)
4. When the data of the speed is out of range. 3. Rotary Encoder pulse (Address: 010EH)
5. When the data of IPM capacity is out of range. 4. Speed (Address: 0104H)
6. When the data of H.CT T URN is out of range. 5. IGBT capacity (Address: 010AH)
7. When the data of motor capacity is out of range. 6. H.CT TURN (Address: 010CH)
8. When the number of service floor is diff erent with SPEC. 7. Motor capacity (Address: 0102H)
9. When the number of shelter plate is different with SPEC. 8. Service floor (Address: 038CH~03CAH)
9. Number of shelter plate (Address: 0300H)

[Reference ] The data troubled can be check ed by A42E(trace data).

If data of each BIT is 1, the SPEC DATA of set BIT is the reason of the trouble.

15 14 13 12 11 10 9 8
Service Shelter
- - - - - -
floor plate
7 6 5 4 3 2 1 0
H.CT Rotary
IGB
IGBT
T Motor
otor - Speed TM Gear
TURN Encoder
Part: : TCD Code
Di1(Si210) Elevator / Trouble Shooting
Shoo ting Ctrl No. : SI-TS-02-2
Page: 45/117

○ Operation CPU
TCD 76
76 EEPR
EPROM Write Tr
Trouble Detection Application Si210
○ Speed CPU

[Meaning ] [Countermeasures ]
When different values are found over 100 times while writing data on
EEPROM and reading data from the same address.
1. Verify if SW2 switch in DOC-131
DOC-131 is switched to “W E” side.
2. Verify if EEPROM is properly inserted into DOC-131.
[Explanation ] This error means that the SPEC DATA is not written properly due to
3. Check EEPROM.
fault
4. Replace SPEC ROM.
Part: : TCD Code
Di1(Si210) Elevator / Trouble Shooting
Shoo ting Ctrl No. : SI-TS-02-2
Page: 46/117

○ Operation CPU
TCD 77 EEPR
EPROM Read Trouble Detection Application Si210
○ Speed CPU

[Meaning ] Different data are found over 4 consecutive times while reading data [Countermeasures ]
from the same address on EEPROM. 1. Check EEPROM.
2. Verify that EEPROM is properly inserted into DOC-131
BOARD.
[Explanation ] If there is any different
different data over 4 times consecutively as same
address data is read. The error is detected 3. Replace SPEC ROM.
Part: : TCD Code
Di1(Si210) Elevator / Trouble Shooting
Shoo ting Ctrl No. : SI-TS-02-2
Page: 47/117

○ Operation CPU
TCD
TCD 78
78 Floo
Floorr Hei
Heigh
ghtt mea
measu
suri
ring
ng Table
able SUM
SUM tro
troub
uble
le Detection Application Si210
○ Speed CPU

[Meaning ] EEPROM floor height measurement table error [Countermeasures ]

1. EEPROM Address (After pressing ANN ‘A31E’)


Address of where floor height
height starts: 1A00H
Floor height table sum : Check the value of 1B10H.
[Explanation ]
2. Re-measure the floor height
3. After measuring the floor height verify if the floor indicating
Addresses starting from 1A00H of EEPROM, floor height value of each floor is saved
value of LCE are conforming to spec. If the values are c ontrary,
after measuring the floor height. In 1B10H of EEPROM, the sum of floor height of each
floor is saved. If even one of three cases below occurs, this error will occur. adjust the plate and check t he installation.
4. Consecutive failure of f loor height measurement, press ‘A31E’
on ANN, enter the address below and confirm the value.
1. When the sum obtained by adding each floor height table value s aved in
EEPROM(1A00H) and the floor height sum data saved in EEPROM
Address ;
does not match.
2. When the floor height sum data in EEPROM is 0(Zero). -Total number of floors : 0300H (Number of shelter plate )
3. When the floor height of the lowest floor of floor height table in EEPROM is not the -Top floor : 041CH
lowest floor height(150000). -Bottom floor : 0420H
-Service floor : 038CH ~ 03CAH

5. Replace SPEC ROM

[S ymptom]
* How to measure floor height
1. Low speed return operation to the lowest level with buzzer ringing and display 1) Press ‘A12E’ on ANN, and press 3.
ACD = 09.
2) If the floor height is measured successfully, press ‘FFFF ’.
2. In case there is no Non-Stop floor, operate the nearest floor.
3. Stop and standby with ACD = 09. 3) If the measuring fails, measure the floor height again.
4) If the measuring fails repeatedly, verify if the total floor number
and the highest floor in EEPROM(28C64) are identical with
those in the field.
Part: : TCD Code
Di1(Si210) Elevator / Trouble Shooting
Shoo ting Ctrl No. : SI-TS-02-2
Page: 48/117

○ Operation CPU
TCD
TCD 79 NVRA
NVRAM
M Floo
Floorr Heig
Height
ht mea
measu
surin
ring
g Tab
Table
le SUM
SUM trou
troubl
ble
e Detection Application Si210
○ Speed CPU

[Meaning ] [Countermeasures ]
NVRAM floor height table error

1. In case only TCD 79 is displayed, the system returns


automatically to normal operation mode.
[Explanation ] 2. In case TCD 79 occurs with TCD 78, perform the
countermeasures of TCD 78.
After measuring of floor height, the floor height value of each floor and the sum of
them are designed to be saved in EEPROM and NVRAM(Backup Ram).

If even one of three cases below occurs, this error will occur.

1. When the sum obtained by adding each floor height table value saved in
NVRAM(Backup RAM) and the floor height sum data saved in
RAM(Backup RAM) does not match.
2. When the floor height sum data in NVRAM is 0(Zero).
3. When the floor height of the lowest floor of f loor height table in NVRAM is
not the lowest floor height(150000).

[S ymptom]

1. Low speed return operation to the lowest level with buzzer ringing and display
ACD = 0B.

2. When DL turns on, alerts by with ACD = 27.