You are on page 1of 4

CONNECTION OF

TRUSS MEMBERS
Truss diagonal web member connection: Welded Connection

Angle Bar: 65 x 65 x 8

Area = 976 mm2

I = 0.383

S = 8.39

r = 19.8

X or y = 19.2

Theoretical mass= 7.66kg.m

Maximum size of weld:

= 8 mm - 2 mm

=6 mm

Use E70, Fu=485

F3= 0.707tL30.3Fu

= 0.707 (6) (65) (0.3) (485)

= 40118.715 N
For computation of L1

 MB=0

F1 (65) = 157390 (45.8) - 40188.715(32.5)

F1 = 90805.058

F1 = 0.707tL10.3Fu

90805.058
L1 = (0.707)(6)(0.3)( 485)

L1 = 147.12 mm

For computation of L2

 MA=0

F2 (65) = 157390 (19.2) - 40188.715(32.5)

F1 = 26431.23

F1 = 0.707tL10.3Fu

26431.23
L1 = (0.707)(6)(0.3)( 485)

L1 = 42.82 mm

For Checking

Total Length = 42.82 + 147.12 + 65

= 254.94 mm

157390
Required Length = (0.707)(6)(0.3)( 485)

= 255.011 mm
Truss vertical web member connection: Welded Connection

Angle Bar: 65 x 65 x 8

Area = 976 mm2

I = 0.383

S = 8.39

r = 19.8

X or y = 19.2

Theoretical mass= 7.66kg.m

Maximum size of weld

= 8 mm - 2 mm

=6 mm

Use E70, Fu=485

P= 0.707t(2L1)0.3Fu

11540 = 0.707 (6) (2L1) (0.3) (485)

L1 = 56. 09 mm