Inlet Turbine Hydraulic Efficiency

Brake Flow Speed Brake Torque Brake Pump Pump Pump Pump
Turbine Pressur
Setting Rate Force Power Motor Setting Speed Power
Under e Head Power
Q n Fb T Pb Torque
Test P H Ph E
[%] [l/min] [rpm] (N) [Nm] [W] [Nm] [%] [rpm] [W]
[kPa] [m] [W] [%]
FM61 Reaction
Turbine 10 9.18 39.0 0 0.37 3.97 5.97 0.016 0.00 0.0 0.15 45 1530 24.8
FM61 Reaction
Turbine 40 9.80 48.3 0 0.58 4.93 7.89 0.026 0.00 0.0 0.21 50 1700 36.6
FM61 Reaction
Turbine 40 10.83 59.3 0 0.61 6.05 10.71 0.027 0.00 0.0 0.26 55 1870 50.9
FM61 Reaction
Turbine 40 12.00 72.0 0 0.67 7.34 14.41 0.030 0.00 0.0 0.32 60 2040 69.0
FM61 Reaction
Turbine 40 12.29 71.8 0 0.67 7.32 14.70 0.030 0.00 0.0 0.32 60 2040 68.4
FM61 Reaction
Turbine 40 13.17 84.8 0 0.79 8.64 18.60 0.035 0.00 0.0 0.39 65 2210 90.2
FM61 Reaction
Turbine 50 14.49 99.7 0 1.02 10.17 24.08 0.046 0.00 0.0 0.49 70 2380 121.8
FM61 Reaction
Turbine 55 14.59 99.7 0 1.29 10.17 24.25 0.058 0.00 0.0 0.49 70 2380 121.8
                             

REACTION TURBINE
IMPULSE TURBINE

Brak Brake Pump Pump Pump


Brake Flow Inlet Spee Turbin Hydrauli Torqu Efficienc Pump Pump
e Motor
Turbine Settin Rate Pressur d e c e y Settin Efficienc
Force Powe Spee Powe
Under g Q e Head Power g y
r Torqu d r
Test [l/min P n H Ph T E
Fb Pb e
[%] ] [kPa] [rpm] [m] [W] [Nm] [%] [%] [%]
(N) [W] [Nm] [rpm] [W]
FM60
Impulse
Turbine 20 11.19 137.3 1080 0.03 14.00 25.61 0.001 0.14 0.5 0.63 70 2380 156.8 16.3
FM60
Impulse
Turbine 30 11.21 137.3 180 0.77 14.00 25.65 0.035 0.66 2.6 0.62 70 2380 154.9 16.6
FM60
Impulse
Turbine 40 11.19 136.5 0 1.06 13.91 25.46 0.048 0.00 0.0 0.62 70 2380 154.1 16.5
FM60
Impulse
Turbine 40 12.51 180.8 0 1.35 18.43 37.70 0.061 0.00 0.0 0.84 80 2720 240.4 15.7
FM60
Impulse
Turbine 40 13.13 206.0 0 1.43 21.00 45.06 0.064 0.00 0.0 0.98 85 2890 297.6 15.1
FM60
Impulse
Turbine 20 12.70 179.7 1860 -0.28 18.32 38.04 -0.013 -2.47 -6.5 0.82 80 2720 232.9 16.3
FM60
Impulse
Turbine 30 12.79 180.0 780 0.70 18.35 38.36 0.032 2.58 6.7 0.81 80 2720 230.7 16.6
FM60 40 12.76 180.0 0 1.31 18.35 38.27 0.059 0.00 0.0 0.82 80 2720 233.4 16.4
Impulse
Turbine
FM60
Impulse
Turbine 10 8.16 40.4 120 -0.30 4.12 5.49 -0.013 -0.17 -3.1 0.15 40 1360 22.0 25.0
FM60
Impulse
Turbine 10 6.50 40.4 180 -0.38 4.12 4.38 -0.017 -0.33 -7.4 0.15 40 1360 21.1 20.7
FM60
Impulse
Turbine 10 5.98 40.1 180 0.06 4.09 4.00 0.003 0.05 1.3 0.16 40 1360 22.2 18.0
FM60
Impulse
Turbine 10 7.62 65.3 420 -0.02 6.65 8.29 -0.001 -0.04 -0.5 0.26 50 1700 46.8 17.7
FM60
Impulse
Turbine 20 7.73 65.8 120 0.38 6.71 8.49 0.017 0.22 2.6 0.27 50 1700 47.6 17.8
FM60
Impulse
Turbine 30 7.72 65.6 0 0.59 6.68 8.43 0.026 0.00 0.0 0.26 50 1700 46.5 18.1
FM60
Impulse
Turbine 30 9.59 100.0 0 0.81 10.20 15.99 0.036 0.00 0.0 0.43 61 2074 94.3 17.0
FM60
Impulse
Turbine 30 9.73 119.0 60 1.00 12.13 19.28 0.045 0.28 1.5 0.55 70 2380 137.2 14.1
FM60
Impulse
Turbine 30 10.59 135.9 180 1.06 13.85 23.99 0.048 0.90 3.8 0.63 70 2380 156.0 15.4
FM60 50 11.00 135.1 0 1.43 13.77 24.76 0.065 0.00 0.0 0.62 70 2380 153.7 16.1
Impulse
Turbine

IMPULSE TURBINE
14.00

12.00

10.00
Flow (l/min)

8.00

6.00

4.00

2.00

0.00
16.33 16.5 16.52 15.68 15.14 16.33 16.63 16.4 24.96 20.72 17.97 17.71 17.82 18.13 16.95 14.06 15.37 16.11
Pump efficiency(%)
REACTION TURBINE
16.00

14.00

12.00

10.00
Flow (l/min)

8.00

6.00

4.00

2.00

0.00
24.1 21.6 21.0 20.9 21.5 20.6 19.8 19.9
Pump efficiency
(%)