W1
FLEXIBLE MASTIC (FIRE RATED AS REQUIRED)
SOFFIT INSULATION
Wall Schedule SCR-04-06 40 mm DEFLECTION ACOUSTIC FELT/FOAM STRIP TO
40
ALLOWANCE BOARD TO SPECIALIST SUPPLIER (FERMACELL)
147 4771 Type Mark Length Area IT Room Number SOFFIT RECOMMENDATIONS
WET ROOM TIMBER BATTEN
A 75X55mm
L4-W009 PT10 3092 13 m² SCR-04-06 40 mm DEFLECTION SUITABLE FISHER FIXINGS AT 400mm CENTRES TO
40
PT10 IT PT10 2920 9 m² SCR-04-06 ALLOWANCE. HEAD TRACK SPECIALIST SUPPLIER (FERMACELL)
216
D 7030 15 m² PT10 3302 12 m² SCR-04-06 TO TOP OF STUD RECOMMENDATIONS
SCREW FIXING TO SPECIALIST SUPPLIER
0
3103
40
ALLOWANCE FIRST FIX TO TIMBER BATTEN
LEG OF HEAD TRACK 75X25mm
FERMACELL DIN STANDARD U-CHANNEL 75X80X0.6mm*
790 2126 2755
2 LAYERS 12.5mm FERMACELL BOARD ON
1 NOTE: IT ROOM REQUIRES BUND
1104
147
2260 120 1135 1605 HD1 EXMESH SECURILATH 3 mm 8.59 MILD
STEEL ON EXTERNAL FACE
3 1 INTERNAL EXTERNAL KEY PLAN
PT10
147
INTERNAL FACE -FOR FLOOR BUILD UPS REFER TO POPULOUS DRAWING THFC-
WET ROOM POP-XX-00-GA-G331-1000
2 PT10 FERMACELL DIN STANDARD 75mm STUD AT TO BE READ IN CONJUNCTION WITH B+K 3008 SCREEDING PRICING
SCHEDULE SECTION 3.0 - MEASURED WORKS
2260 400mm CENTRES (for SR2 Security Rating)
60mm MINERAL STONE WOOL DENSITY 30kg/m³ -FOR DOOR SECURITY REFER TO DRAWING THFC-BHE-XX-LXX-SM-
SE
US-0701
SKIRTING TBC
FLANKING LIMIT 1, FOR THERMAL WALL DETAILS REFER TO POPULOUS DRAWING
L,W,R 55dB THFC-POP-Z02-00-GA-G252 - 1102 -1
W1 FERMACELL DIN STANDARD U-CHANNEL 75X40X0.6mm*
ACOUSTIC FELT/FOAM STRIP TO FERMACELL
1 L4-W009 - SCR-04-06 - PLAN RECOMMENDATIONS IN ABEYANCE
7030 SCALE 1 : 50 FLEXIBLE MASTIC (FIRE RATED AS REQUIRED)
FINISH TBC
SCREED LEGEND
W1
BY 1000 GAUGE SEPARETING LAYER WALL TYPE AC - ACOUSTIC PERFORMACE
FR - FIRE RESISTANCE
OTHERS AC FR
INSULATION
1200 GAUGE DPM
SE
7 Partition Type 10 - PT 10
7030 SCALE 1 : 5
W1 REVISIONS
2 L4-W009 - SCR-04-06 - RCP No. DATE DESCRIPTION
7030 SCALE 1 : 50 0 03/07/2017 CONSTRUCTION
(DULUX TRADE
3745
2864
DIAMOND MATT)
M50/FL-401
ANTISTATIC VINYL
SCREED - ONLY
BONDED SCREED - a: 5 Rochester Mews - London - NW1 9JB
FIBRE AND MESH t: 020 7267 8332
REINFORCED w: f3architects.co.uk
e: info@f3architects.co.uk
(TO POP SPEC)
FFL +28155 FFL +28155
Except for Planning purposes, figured dimensions only are to
be taken from this drawing.
All dimensions are in millimeters unless otherwise stated.
All dimensions shall be checked on site prior to works
commencing.
Any discrepancies shall be reported to the Architect.
B L4-W009 - SCR-04-06 - Elevation A A L4-W009 - SCR-04-06 - Elevation B © Copyright F3 Architecture + Design. All rights reserved.
7030 SCALE 1 : 50 7030 SCALE 1 : 50
Project Name
LILYWHITE HOUSE
782 HIGH ROAD
D4-W008
+31020
LONDON
N17 0BX
2600 STRUCT. OPENING
3865
3865
3745
2864
Drawing Title
CS IL As indicated A1 160919-THS
C L4-W009 - SCR-04-06 - Elevation C D L4-W009 - SCR-04-06 - Elevation D Drawing No Revision
7030 SCALE 1 : 50 7030 SCALE 1 : 50
THFC-5000-Z01-L04-DR-XXX- 7030 0
© Copyright F3 Architecture + Design. All rights reserved.