You are on page 1of 24

1 2 3 4 5 6 7 8

A A

B B

C
Power Cabinet Electrical Wiring Diagram C

ECO100 Platform V3
Reproduction, use or disclosure to third parties without express authority is strictly forbidden.

=G15 +PC
We reserve all rights in this document and in the information contained therein.

D D

POWER CABINET

E E
Alstom.

F F
03 01 27-05-2014 XAF PGG MO EC-00228 Galileo; EC00217 Typhoon System Des. XAF Drawing Nº: SUPPLY: Modify.: 03
03 01 28-03-2014 XAF PGG MO EC-00225 Draw.15100238 deleted article ECO100 Platform V3 15000032 15100095
Comp. PGG Version: 01
03 00 13-01-2014 XAF PGG MO EC-11936 Update V3 COVER Apr. MO Art. :
02 01 19-10-2012 XAF PGG MO EC-10226 Mistakes =G15 +PC
Modif. Vers. Date Des. Comp. Apr. Observations POWER CABINET Date 27-05-2014 Sheet COV 340 Sh.

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

Page index
A A
Higher Level Assignment: =G15 Location designation: +PC

Sheet Description Date Editor


COV COVER 27-05-2014 XAF
IND1 INDEX - 1 27-05-2014 XAF
B B
INF1 WIRE COLOUR CODE 27-05-2014 XAF
INF2 HOSES WIRE COLOUR CODE 27-05-2014 XAF
1 POWER DISTRIBUTION 1000V -1 27-05-2014 XAF
2 POWER DISTRIBUTION 1000V -2 27-05-2014 XAF
3 POWER DISTRIBUTION 230V 27-05-2014 XAF
4 MAIN CB MANOEUVRE 27-05-2014 XAF
C C
5 CONTACTOR MANOEUVRE 27-05-2014 XAF
6 24V SIGNALS TO CONTROL CABINET 27-05-2014 XAF
7 ARC MONITOR OPTION 27-05-2014 XAF
8 230V SIGNALS 27-05-2014 XAF
Reproduction, use or disclosure to third parties without express authority is strictly forbidden.

9 24V SIGNALS TO CONVERTER 27-05-2014 XAF


10 TERMINAL SPARE 27-05-2014 XAF
We reserve all rights in this document and in the information contained therein.

D 11 RESERVED GROUND PLATES 27-05-2014 XAF D

12 SPARE 27-05-2014 XAF


A1 CABINET EXTERNAL VIEW 27-05-2014 XAF
A2 CABINET INTERNAL VIEW 27-05-2014 XAF
A3 CABINET GROUNDING 27-05-2014 XAF
MAT1 ASSIGNED MATERIAL -1 27-05-2014 XAF
E
MAT2 ASSIGNED MATERIAL -2 27-05-2014 XAF E
MAT3 ASSIGNED MATERIAL -3 27-05-2014 XAF
MAT4 ASSIGNED MATERIAL -4 27-05-2014 XAF
MAT5 ASSIGNED MATERIAL +PC.WOODWARD VARIANT 27-05-2014 XAF
Alstom.

F F
03 01 27-05-2014 XAF PGG MO EC-00228 Galileo; EC00217 Typhoon System Des. XAF Drawing Nº: SUPPLY: Modify. 03
03 01 28-03-2014 XAF PGG MO EC-00225 Draw.15100238 deleted article ECO100 Platform V3 15000032 15100095
Comp. PGG Version: 01
03 00 13-01-2014 XAF PGG MO EC-11936 Update V3 INDEX - 1 Apr. MO Art. :
02 01 19-10-2012 XAF PGG MO EC-10226 Mistakes =G15
Modif. Vers. Date Des. Comp. Apr. Observations POWER CABINET Date 27-05-2014
+PC
Sheet IND1 340 Sh.
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

A A

INTERNAL WIRE COLOUR EXTERNAL WIRE COLOUR

AUXILIARY POWER CABLES


B
WIRE COLOUR CODE - IEC WIRE COLOUR CODE - IEC B

PHASES R,S,T
50V ac ≤ V ≤ 1000V ac
NEUTRAL PHASE R
400V dc PHASE S
50V ac ≤ V ≤ 1000V ac
GROUND PHASE T
EXTERNAL POWER SOURCE NEUTRAL
UPS 24V dc GROUND

C C

AUXILIARY POWER CABLES


Reproduction, use or disclosure to third parties without express authority is strictly forbidden.

WIRE COLOUR CODE - UL WIRE COLOUR CODE - UL


We reserve all rights in this document and in the information contained therein.

D PHASES R,S,T D
50V ac ≤ V ≤ 1000V ac
NEUTRAL PHASE R
400V dc PHASE S
50V ac ≤ V ≤ 1000V ac
GROUND PHASE T
EXTERNAL POWER SOURCE NEUTRAL
UPS 24V dc GROUND

E E

Electrical diagram colour code as IEC standard.


For real colour code check internal cabinet "wire colour code" label
Alstom.

All internal cables and external Cu material type.

F F
03 01 27-05-2014 XAF PGG MO EC-00228 Galileo; EC00217 Typhoon System Des. XAF Drawing Nº: SUPPLY: Modify.: 03
03 01 28-03-2014 XAF PGG MO EC-00225 Draw.15100238 deleted article ECO100 Platform V3 15000032 15100095
Comp. PGG Version: 01
03 00 13-01-2014 XAF PGG MO EC-11936 Update V3 WIRE COLOUR CODE Apr. MO Art. :
02 01 19-10-2012 XAF PGG MO EC-10226 Mistakes =G15 +PC
Modif. Vers. Date Des. Comp. Apr. Observations POWER CABINET Date 27-05-2014 Sheet INF1 340 Sh.

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

COLOURS ABBREVIATIONS CABLE IDENTIFICATION CABLE IDENTIFICATION


DIN 47100 UNE 21089-1 / HD 308
A COLOUR DESCRIPTION A
WH WHITE
BN BROWN
Nº COLOUR Nº COLOUR Nº OF PAIRS COLOUR Nº OF PAIRS COLOUR
GN GREEN
1 WH 31 GN/BL 1 BK/RD 28 OR/YE
YE YELLOW
2 BN 32 YE/BL 2 BK/WH 29 VI/OR
OR ORANGE
3 GN 33 GN/RD 3 BK/GN 30 VI/RD
GY GRAY
4 YE 34 YE/RD 4 BK/BL 31 VI/WH
PK PINK
5 GY 35 GN/BK 5 BK/YE 32 VI/DG
B B
BL BLUE
6 PK 36 YE/BK 6 BK/BN 33 VI/LB
LB LIGHT BLUE
7 BL 37 GY/BL 7 BK/OR 34 VI/YE
CY CYAN
8 RD 38 PK/BL 8 RD/WH 35 VI/BN
LC LIGHT CYAN
9 BK 39 GY/RD 9 RD/GN 36 VI/BK
RD RED
10 VI 40 PK/RD 10 RD/BL 37 GY/WH
BK BLACK
11 GY/PK 41 GY/BK 11 RD/YE
VI VIOLET
12 RD/BL 42 PK/BK 12 RD/BN
LM LIGHT MAGENTA
13 WH/GN 43 BL/BK 13 RD/OR
C MG MAGENTA C
14 BN/GN 44 RD/BK 14 GN/WH
GL GOLD
15 WH/YE 45 WH/BN/BK 15 GN/BL
DG DARK GREEN
16 YE/BN 46 YE/GN/BK 16 GN/YE
17 WH/GY 47 GY/PK/BK 17 GN/BN
18 GY/BN 48 RD/BL/BK 18 GN/OR
CABLE IDENTIFICATION
Reproduction, use or disclosure to third parties without express authority is strictly forbidden.

19 WH/PK 49 WH/GN/BK 19 WH/BL


IEC 60228 / HD 21 20 PK/BN 50 BN/GN/BK 20 WH/YE
PAIRS WIRED TOGETHER WITH SCREEN SET
21 WH/BL 51 WH/YE/BK 21 WH/BN
We reserve all rights in this document and in the information contained therein.

Nº OF PAIRS PAIR
D 22 BN/BL 52 YE/BN/BK 22 WH/OR D
1 1-1_BK
23 WH/RD 53 WH/GY/BK 23 BL/YE
2 1-2_BL
24 BN/RD 54 GY/BN/BK 24 BL/BN
3 2-1_BK
25 WH/BK 55 WH/PK/BK 25 BL/OR
4 2-2_BL
26 BN/BK 56 PK/BN/BK 26 BN/YE
5 3-1_BK
27 GY/GN 57 WH/BL/BK 27 BN/OR
6 3-2_BL
28 YE/GY 58 BN/BL/BK
7 4-1_BK
29 PK/GN 59 WH/RD/BK
8 4-2_BL
30 YE/PK 60 BN/RD/BK
E E
9 5-1_BK
... ...

Electrical diagram colour code as IEC standard.


For real colour code check internal cabinet "wire colour code" label
Alstom.

All internal cables and external Cu material type.

F F
03 01 27-05-2014 XAF PGG MO EC-00228 Galileo; EC00217 Typhoon System Des. XAF Drawing Nº: SUPPLY: Modify.: 03
03 01 28-03-2014 XAF PGG MO EC-00225 Draw.15100238 deleted article ECO100 Platform V3 15000032 15100095
Comp. PGG Version: 01
03 00 13-01-2014 XAF PGG MO EC-11936 Update V3 HOSES WIRE COLOUR CODE Apr. MO Art. :
02 01 19-10-2012 XAF PGG MO EC-10226 Mistakes =G15 +PC
Modif. Vers. Date Des. Comp. Apr. Observations POWER CABINET Date 27-05-2014 Sheet INF2 340 Sh.

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
4
4
/2.A1
5
5
/2.A1
6
6
/2.A1
A A

6
L I1=0,95 -Q1.1
t1=3s -WPE1
1 3 5
S I2=2,5
21
t2=0,1s Curve:L
M /1.E5
I I3=5

25mm²
G I4=0,2 2 4 6
t4=0,1s Curve:L
299
1

3
F=50Hz/60Hz --> According to site

InN=OFF
B B
Short-circuit Wire Protected 95mm²

35mm²
1

3
1 3 5
-F1.1
125A -WPE1 -WPE1
F:0.8A gBR
2 4 6 4 3
/1.C8 /A3.E1 /11.B1 /1.C7

292

293

294
-WPE1
12 1000V 0V 1000V 0V

-WGNDCONV
C C

1x95 - 3/0 AWG GN/YE


/11.B5 /11.B6
-T1.1 -T1.2

299 35mm²
1 3 5
1

400V 0V 400V 0V

2,5mm²
-F1.2
250A
F:100A 2 4 6

1021
1019

1020

1022
1 3 5 7N
T

-Q1.6
-WT12W1 1x240 - 535MCM AWG BK -IEC=GY UL=BL TAPE
-WT12W2 1x240 - 535MCM AWG BK -IEC=GY UL=BL TAPE
-WT12W3 1x240 - 535MCM AWG BK -IEC=GY UL=BL TAPE
-WT12W4 1x240 - 535MCM AWG BK -IEC=GY UL=BL TAPE
Reproduction, use or disclosure to third parties without express authority is strictly forbidden.

25 A
30 mA R
-WT12U1 1x240 - 535MCM AWG BK - BN TAPE
-WT12U2 1x240 - 535MCM AWG BK - BN TAPE
-WT12U3 1x240 - 535MCM AWG BK - BN TAPE
-WT12U4 1x240 - 535MCM AWG BK - BN TAPE

-WT12V1 1x240 - 535MCM AWG BK - BK TAPE


-WT12V2 1x240 - 535MCM AWG BK - BK TAPE
-WT12V3 1x240 - 535MCM AWG BK - BK TAPE
-WT12V4 1x240 - 535MCM AWG BK - BK TAPE

892

978

979

892

978

979
2 4 6 8N
We reserve all rights in this document and in the information contained therein.

-WGNDPC

1,5mm²
1x150 - 300 AWG GN/YE

D D
624
622 622

623 623

-F1.3

299

299
L1 L1 L1 L1 L2 L3
624

-F1.4
-F1.5 /6.B6 /6.B6 /6.C7 -F1.6

=G16+CC/1.E3

=G14+CONV/1.D3
=G16+CC/84.B3

=G16+CC/84.B3

=G16+CC/84.B3

PE PE PE /6.C7
PE PE

-W1.1
299

25mm²
299 25mm²
=G18+5 TOW WIRING/2.C5

PELIGRO! TENSIÓN EN CABLEADO NARANJA

299
1
1
1
1

2
2
2
2

3
3
3
3

CON INTERRUPTOR PRINCIPAL DESCONECTADO.


E -WPE1 -WPE1 E
=G24+MV/LV/1.E6
=G24+MV/LV/1.E6
=G24+MV/LV/1.E6
=G24+MV/LV/1.E6

=G24+MV/LV/1.E6
=G24+MV/LV/1.E6
=G24+MV/LV/1.E6
=G24+MV/LV/1.E7

=G24+MV/LV/1.E7
=G24+MV/LV/1.E7
=G24+MV/LV/1.E7
=G24+MV/LV/1.E7

DANGER! VOLTAGE IN ORANGE WIRING


WITH MAIN SWITCH DISCONNECTED.
20 18
DANGER ! TENSION DANS LE CÂBLAGE ORANGE /11.B4 /1.A3 /11.B3 /11.B4
AVEC INTERRUPTEUR PRINCIPAL DÉCONNECTÉ.

PERICOLO! TENSIONE IN CAVI ARANCIONI


CON INTERRUTTORE PRINCIPALE SCOLLEGATO.
Alstom.

PERIGO! TENSÃO IN CABOS LARANJAS


COM INTERRUPTOR PRINCIPAL DESLIGADO.

1kV FROM TRANSFORMER MED V_CC OVERVOLTAGES PROTECTION GROUND

F F
03 01 27-05-2014 XAF PGG MO EC-00228 Galileo; EC00217 Typhoon System Des. XAF Drawing Nº: SUPPLY: Modify.: 03
03 01 28-03-2014 XAF PGG MO EC-00225 Draw.15100238 deleted article ECO100 Platform V3 15000032 15100095
Comp. PGG Version: 01
03 00 13-01-2014 XAF PGG MO EC-11936 Update V3 POWER DISTRIBUTION 1000V -1 Apr. MO Art. :
02 01 19-10-2012 XAF PGG MO EC-10226 Mistakes =G15 +PC
Modif. Vers. Date Des. Comp. Apr. Observations POWER CABINET Date 27-05-2014 Sheet 1 340 Sh.

1 2 3 4 5 6 7 8
F
A

E
B

D
C
We reserve all rights in this document and in the information contained therein.
Reproduction, use or disclosure to third parties without express authority is strictly forbidden.
Alstom.

/1.A8
/1.A8
/1.A8

6
5
4

/A3.E1
-WGNDGENSTATOR

-WPE1

1
1

299 1x95 - 3/0 AWG 1


=G14+GEN/1.D4

6
-WG1V1.1
17 1x240 - 535MCM AWG BK - BN TAPE 17

/3.E2
=G14+GEN/1.D2
-WG1V1.2
17 1x240 - 535MCM AWG BK - BN TAPE 17

02
03
03
03
=G14+GEN/1.D2
-WG1V1.3
17 1x240 - 535MCM AWG BK - BN TAPE 17

00
01
01
=G14+GEN/1.D2

Modif. Vers.
/5.E3
-KM1.1

30VA
1A
2000A
30VA
1A
2000A
30VA
1A
2000A

-T1.5
-T1.4
-T1.3
-WG1V1.4 17 4
17 1x240 - 535MCM AWG BK - BN TAPE 17
=G14+GEN/1.D2
1
2

P1
P2

Date
-WG1U1.1 18 5

S2
S1
18 1x240 - 535MCM AWG BK - BK TAPE 18

01 27-05-2014

19-10-2012
13-01-2014
28-03-2014
=G14+GEN/1.D2
3
4

P1
P2
-WG1U1.2 19 6

STATOR
S2
S1
18 1x240 - 535MCM AWG BK - BK TAPE 18

XAF
XAF
XAF
XAF

2
2

=G14+GEN/1.D3
5
6

P1
P2
-WG1U1.3

S2
S1
18 1x240 - 535MCM AWG BK - BK TAPE 18
=G14+GEN/1.D3

PGG
PGG
PGG
PGG
-WG1U1.4

Des. Comp.
18 1x240 - 535MCM AWG BK - BK TAPE 18
10mm²

=G14+GEN/1.D3
35mm²
10mm²

-WG1W1.1

MO
MO
MO
MO
19

Apr.
19 1x240 - 535MCM AWG BK -IEC=GY UL=BL TAPE

16
15
14
13
12
11
=G14+GEN/1.D3
-WG1W1.2
19 1x240 - 535MCM AWG BK -IEC=GY UL=BL TAPE 19
=G14+GEN/1.D3
-WG1W1.3
19 1x240 - 535MCM AWG BK -IEC=GY UL=BL TAPE 19
=G14+GEN/1.D4
-WG1W1.4
19 1x240 - 535MCM AWG BK -IEC=GY UL=BL TAPE 19

EC-10226 Mistakes
=G14+GEN/1.D4

EC-11936 Update V3

3
3

-WMed_I
4x2x0,75 - 18 AWG 4x2C -XPC-2-24VDC

d
11 WH
=G14+CONV/2.E6
100

100-d

EC-00225 Draw.15100238 deleted article


12 BN

Observations
=G14+CONV/2.E7
101

EC-00228 Galileo; EC00217 Typhoon System


100-c

b
13 GN
=G14+CONV/2.E7
102

100-b

a
14 YE
=G14+CONV/2.E7 100-a 103

*Cable entry view (Aerial connector view)

4
4

d
15 GY
=G14+CONV/2.E7
104
104-d

c
16 PK
=G14+CONV/2.E7

STATOR CURRENT MEASUREMENT


105
104-c

b
7 BL
=G14+CONV/2.E7
106
104-b

a
8 RD
=G14+CONV/2.E7
107
104-a

*Cable entry view (Aerial connector view)


299
Brida EMC

5
5

+PC.WOODWARD VARIANT
11
12
14
+PC/9.C4

-WINVFILTER-R
F:100A
100A

617 1 1x35 - 2 AWG 617 17


=G14+CONV/4.E7
11

-WINVFILTER-S
12
F:100A
100A

618 618 18

POWER CABINET
1 1x35 - 2 AWG
=G14+CONV/4.E7

ECO100 Platform V3
14 11

VARIANT

-WINVFILTER-T
-F1.7 -F1.8 -F1.9

12
14
F:100A
100A

+PC/9.B4 +PC/9.B4

619 1 1x35 - 2 AWG 619 19


=G14+CONV/4.E7

6
6

POWER DISTRIBUTION 1000V -2


ONLY USED FOR WOODWARD CONVERTER

STATUS FILTER (ONLY WOODWARD CONVERTER)

-XPC-400VAC
F:0.8A GBR
125A
-F1.10

-WMed_V
Apr.
Des.

Date
400V
-T1.6
1000V

29 20 17 10mm²
Comp.

29 8x1,5 - 16 AWG 8C 1
6
5
4

=G14+CONV/2.E4
1

1
0V
0V

30 2 21 18
3

=G14+CONV/2.E4
MO
XAF
4
3

PGG

3
27-05-2014
400V
1000V

31 3 31 22 19
5

=G14+CONV/2.E4
6
5

5
0V
0V

39
7
7

39 4
7

=G14+CONV/2.E5
7
*Cable entry view (Aerial connector view)

Drawing Nº:

=G15
-T1.7

15000032
F:0.8A GBR
125A
-F1.11

400V
-T1.8
1000V

32 5 32 25 10mm² 4
2

=G14+CONV/2.E4
1

2
0V
0V

VOLTAGE MEASURING

33 6 26 5
4

=G14+CONV/2.E5
4
3

+PC

4
SUPPLY:
15100095
400V
1000V

34 7 34 27 6
6

=G14+CONV/2.E5
6
5

6
0V
0V

40 8 40
8

=G14+CONV/2.E5
8
8
8

*Cable entry view (Aerial connector view)

Art. :
Sheet 2
Modify.:
Version:
-T1.9

03
01

340 Sh.
F
A

E
B

D
C
1 2 3 4 5 6 7 8

=G16+CC/18.E7

=G16+CC/18.E7
UPS INCOME
A A

=G16+CC/25.E3

=G16+CC/25.E3
1239

1240

+PC.ARC MONITOR OPTION


2,5mm²
2,5mm²
1239

+PC/7.C3

+PC/7.C4
505

503
B B
1

3
2

4
-XPC-1-230VAC

505

503
1239

1239

1239

1240

1239

1239

505 1,5mm²
3 2 11 23 12 14 42 44
-B1.1
-B1.2 -10...50ºC/14...122ºF -KA1.5 -KA1.5

503

505

503
35...95% <φ 20....80ºC/68...176ºF /3.D2 /3.D2
12 24

-XPC-1-UPS-230VAC
Reg.:85% L 11 41
YAW UPS VARIANT= Reg.:95% Reg.:10ºC/50ºF Reg.:35ºC/95ºF
67

C C
10

10
9

3
5
7
9

2
4
6
8
1
-XPC-1-230VAC

41
67

505
505
505

503
503
503
1
-B1.3
-10...50 ºC/14...122 ºF
Reg.:35ºC/95ºF 2
Reproduction, use or disclosure to third parties without express authority is strictly forbidden.

79

-XPC-1-230VAC

A1
42
44
12
14

-KA1.5
We reserve all rights in this document and in the information contained therein.

D 220 Vac D
41
11

A2
/3.C4

/3.C4

/3.D2
5

7
6

8
1240

50

58
12
11

-WPE1 -XPC-1-230VAC
6
/2.C1 /7.A4

505
505
505
505

503
503
503
503
13
14

-XPC-1-230VAC

/4.A2

/4.E2
/4.B3
/5.A4
/4.A4

/4.E4
/5.D4
/4.E3
E E
299
299

1240

1240

1240

1240
41

41

50

58

L N PE L N PE
230Vac M 230Vac M
64 W 64 W -E1.1 -E1.2
~ ~
Alstom.

240x240x90 240x240x90 1.200W 1.200W


5,2A. 5.2 A
-M1.1 -M1.2
CABINET FAN CABINET HEATING RESISTOR
MANOEUVRE
CABINET TEMPERATURE CONTROL
F F
03 01 27-05-2014 XAF PGG MO EC-00228 Galileo; EC00217 Typhoon System Des. XAF Drawing Nº: SUPPLY: Modify.: 03
03 01 28-03-2014 XAF PGG MO EC-00225 Draw.15100238 deleted article ECO100 Platform V3 15000032 15100095
Comp. PGG Version: 01
03 00 13-01-2014 XAF PGG MO EC-11936 Update V3 POWER DISTRIBUTION 230V Apr. MO Art. :
02 01 19-10-2012 XAF PGG MO EC-10226 Mistakes =G15 +PC
Modif. Vers. Date Des. Comp. Apr. Observations POWER CABINET Date 27-05-2014 Sheet 3 340 Sh.

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

/3.E7

/3.E7

=G16+CC/23.E3

=G16+CC/23.E3
505

505
A A

505

505

/6.C2

/6.C3
/9.B3

/9.B3
/6.C2
/3.E7

109
110

24-3

606

10

606
12 14

505

24-3
11 -KA1.2

109
110
/8.E3 /6.E3
-KA1.1 11

505
12

24-3
14
1 3

22
14
48

10
-Q1.4
B 3A B
1015

21
13
2 4

48
22 32 14 -KA1.4

/6.C5
-S1.0 /4.B7

42

43
A2

/8.B4
12
-KA1.4 11
DOOR LIMIT SWITCH /9.C3 14
24 Vdc
21 31 13 /4.B8 A1 22
21
24

637
24 Vdc

/8.B5
637
=G16+CC/59.C5

51
C C
1015

24-3

606

979

606
51
44

42
C11 D1 C1 U1 13 23 98 37
Reproduction, use or disclosure to third parties without express authority is strictly forbidden.

M -Y0 -Y2 -YC0 -M0 M -Q1 -Q3 -S51 -S33M


230 V 230 V 230 V ~
We reserve all rights in this document and in the information contained therein.

C12 D2 C2 U2 14 24 96 95 38
D D
-Q1.1
503

1039

24-3
503

503

602

604
197
43

E E

1039

24-3
503

503

503

602

604
197

/9.B2

/6.C2
/3.E7

/3.E8

/3.E7

=G16+CC/54.B6

=G16+CC/54.B6

/9.B4
Alstom.

1st OPENING COIL 2ond OPENING COIL CLOSING COIL SPRING MOTOR STATUS CONTACT TO +CC STATUS CONTACT TRIP STATUS CONTACT READY TO BE CLOSED
TO CONVERTER
F F
03 01 27-05-2014 XAF PGG MO EC-00228 Galileo; EC00217 Typhoon System Des. XAF Drawing Nº: SUPPLY: Modify.: 03
03 01 28-03-2014 XAF PGG MO EC-00225 Draw.15100238 deleted article ECO100 Platform V3 15000032 15100095
Comp. PGG Version: 01
03 00 13-01-2014 XAF PGG MO EC-11936 Update V3 MAIN CB MANOEUVRE Apr. MO Art. :
02 01 19-10-2012 XAF PGG MO EC-10226 Mistakes =G15 +PC
Modif. Vers. Date Des. Comp. Apr. Observations POWER CABINET Date 27-05-2014 Sheet 4 340 Sh.

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

A A

/6.C2
/3.E7

/9.B3

/9.B3
505

24-3

606

606
505
B B

1
-KA1.3
/8.E4
230Vac 2

24-3
692

606

606
C C
Reproduction, use or disclosure to third parties without express authority is strictly forbidden.

A1 43 13 21
-KM1.1 -KM1.1 -KM1.1 -KM1.1
/5.F3 /5.E3 /5.E3
A2 44 14 22
We reserve all rights in this document and in the information contained therein.

D /5.E4 D

601
503

196

193
601
503

196

193
/9.B2

/9.B2
/3.E8

-KM1.1 =G16+CC/54.B3
E /5.D4 E
1 2
3 4
/2.B2
5 6
13 14
/5.D5
21 22
/5.D6
31 32
Alstom.

43 44
/5.D5

STATOR CONTACTOR COIL CONTACTOR STATUS CONTACTOR STATUS NO CONTACTOR STATUS NC


TO +CC TO CONVERTER TO CONVERTER
F F
03 01 27-05-2014 XAF PGG MO EC-00228 Galileo; EC00217 Typhoon System Des. XAF Drawing Nº: SUPPLY: Modify.: 03
03 01 28-03-2014 XAF PGG MO EC-00225 Draw.15100238 deleted article ECO100 Platform V3 15000032 15100095
Comp. PGG Version: 01
03 00 13-01-2014 XAF PGG MO EC-11936 Update V3 CONTACTOR MANOEUVRE Apr. MO Art. :
02 01 19-10-2012 XAF PGG MO EC-10226 Mistakes =G15 +PC
Modif. Vers. Date Des. Comp. Apr. Observations POWER CABINET Date 27-05-2014 Sheet 5 340 Sh.

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

A A

24-3
12 14
-F1.3
/1.D5
11

91
B B
12 14
-F1.4
/1.D5
11
A1

884
-KA1.2
24 Vdc 12 14
/6.E3 A2

24-3

24-3

24-3
-F1.5
/1.D5
11

1014
1 13 22 24 12 14
10

C -B1.0 -Q1.4 -KA1.1 -F1.6 C


/4.B3
/4.B5
/5.A5
/4.E7

/4.B7

0...60ºC/32...140ºF /4.B5 /8.F3 /1.D6


Reg.:60ºC/140ºF 2 14 21 11
24-3
24-3
24-3
24-3

10

-XPC-1-24VDC
13
15
11
Reproduction, use or disclosure to third parties without express authority is strictly forbidden.

3
5
7
9

2
4
6
1
24-3

291
99

97

95

92
10
We reserve all rights in this document and in the information contained therein.

+PC.ARC MONITOR OPTION

0,5mm²
1,5mm²

1,5mm²

D D
24-3
24-3
+PC/7.C5
+PC/7.C5
24-3

291
99
10

97

95

92
=G16+CC/66.E2

=G16+CC/54.B2
=G16+CC/26.E3

=G16+CC/26.B3

=G16+CC/54.B2

=G16+CC/54.B7

=G16+CC/54.B5
E E

-KA1.2
/6.C2
12
11
/4.B4 14
22
Alstom.

21
24
24 Vdc

REMOTE CONTROL ACTIVE HIGH TEMP. POWER CABINET AUX. POWER BREAKER +PC MAIN CB OPENED BY CONV. OVERVOLTAGE 1000V
F F
03 01 27-05-2014 XAF PGG MO EC-00228 Galileo; EC00217 Typhoon System Des. XAF Drawing Nº: SUPPLY: Modify.: 03
03 01 28-03-2014 XAF PGG MO EC-00225 Draw.15100238 deleted article ECO100 Platform V3 15000032 15100095
Comp. PGG Version: 01
03 00 13-01-2014 XAF PGG MO EC-11936 Update V3 24V SIGNALS TO CONTROL CABINET -1 Apr. MO Art. :
02 01 19-10-2012 XAF PGG MO EC-10226 Mistakes =G15 +PC
Modif. Vers. Date Des. Comp. Apr. Observations POWER CABINET Date 27-05-2014 Sheet 6 340 Sh.

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

A A
-WPE1
8
/3.E2 /11.B3

=G16+CC/110.C6
=G16+CC/59.C6
B B

+PC/6.D2

+PC/6.D2
+PC/3.B8

+PC/3.B8
505

503

882

24-3

289
24-3
24-3

24-3
505

503

882

289
C C
L1 N PE
-A1.1
36397 K1 K2 K3 K4 K5 K6

IRF U>0 & Trip


Arc Monitor
Reproduction, use or disclosure to third parties without express authority is strictly forbidden.

TVOC-2 -240
We reserve all rights in this document and in the information contained therein.

I>
D D
+PC.ARC MONITOR OPTION

X3 X2 X1

1 2 3 4 5 6 7 8 9 10 21 22 23

FO quantity and possition defined on assembly drawing

E E
Alstom.

F F
03 01 27-05-2014 XAF PGG MO EC-00228 Galileo; EC00217 Typhoon System Des. XAF Drawing Nº: SUPPLY: Modify.: 03
03 01 28-03-2014 XAF PGG MO EC-00225 Draw.15100238 deleted article ECO100 Platform V3 15000032 15100095
Comp. PGG Version: 01
03 00 13-01-2014 XAF PGG MO EC-11936 Update V3 ARC MONITOR OPTION Apr. MO Art. :
02 01 19-10-2012 XAF PGG MO EC-10226 Mistakes =G15 +PC
Modif. Vers. Date Des. Comp. Apr. Observations POWER CABINET Date 27-05-2014 Sheet 7 340 Sh.

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

A A

A1 A1 -WPOTCONV
-KA1.1 -KA1.3

/4.C4
/4.B4
220 Vac 230Vac
/8.E4 A2 /8.E4 A2 WIRE DESCRIPTION

51
48
WH STATOR CONTACTOR OPEN/CLOSE COMMAND
B B
BN NEUTRAL - 230 V

53

54

55
GN OPEN MAIN CIRCUIT BREAKER COMMAND

50

51

52

53

54

55

56

57
-XPC-2-230VAC YE NEUTRAL - 230 V
50-d 50-c 50-b 50-a 54-d 54-c 54-b 54-a
GY SPARE

PK SPARE

51
53

52

54

55

56

57

48
BL CLOSE MAIN CB COMMAND (N/O CONTACT)
C C
RD CLOSE MAIN CB COMMAND (N/O CONTACT)

4x2x0,75 - 18 AWG 4x2C WH


-WPOTCONV

GN

RD
GY
BN

YE

PK

BL
Reproduction, use or disclosure to third parties without express authority is strictly forbidden.
We reserve all rights in this document and in the information contained therein.

D D

51
53

52

54

55

56

57

48
=G14+CONV/3.E1

=G14+CONV/3.E1

=G14+CONV/3.E1

=G14+CONV/3.E2

=G14+CONV/3.E2

=G14+CONV/3.E2

=G14+CONV/3.E2

=G14+CONV/3.E2

E d c b a d c b a E

*Cable entry view (Aerial connector view) *Cable entry view (Aerial connector view)

-KA1.1 -KA1.3
/8.B3 /8.B4
12 1 2
11 /5.B4
/4.B2 14 3 4
Alstom.

22
21
/6.C6 24
220 Vac

230V SIGNALS TO CONVERTER


F F
03 01 27-05-2014 XAF PGG MO EC-00228 Galileo; EC00217 Typhoon System Des. XAF Drawing Nº: SUPPLY: Modify.: 03
03 01 28-03-2014 XAF PGG MO EC-00225 Draw.15100238 deleted article ECO100 Platform V3 15000032 15100095
Comp. PGG Version: 01
03 00 13-01-2014 XAF PGG MO EC-11936 Update V3 230V SIGNALS Apr. MO Art. :
02 01 19-10-2012 XAF PGG MO EC-10226 Mistakes =G15 +PC
Modif. Vers. Date Des. Comp. Apr. Observations POWER CABINET Date 27-05-2014 Sheet 8 340 Sh.

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

A A

ONLY USED FOR SEG CONVERTER


/5.D6

/5.D5

/4.E6

/4.B8
/4.B6
/5.A6
/5.A5

/4.E8

200
601
193

602

606

606

606

606

604
2 4
-F1.9

601

602

606

606

606

606

604
193
+PC/2.C6

-XPC-1-24VDC
1

409
B B

10
12

+PC.WOODWARD VARIANT
8
2 4
-F1.8
+PC/2.C6
1

606
12 14 423

-KA1.4 -WSENINV
/4.B7
11 2 4
-F1.7 WIRE DESCRIPTION
+PC/2.C5
1 WH STATOR CONTACTOR STATUS NC
C C
BN STATOR CONTACTOR STATUS NO

201
200
GN MAIN C. BREAKER STATUS
108

109

110

112

113

114

115
111

-XPC-2-24VDC
YE MAIN CIRCUIT BREAKER TRIPPED
108-d 108-c 108-b 108-a 112-d 112-c 112-b 112-a
601

201
602

603

606

604

200
WH 193

PK 24 VDC FROM CONVERTER


-WSENINV
4x2x0,75 - 18 AWG 4x2C
Reproduction, use or disclosure to third parties without express authority is strictly forbidden.

GN

RD
GY
BN

YE

PK

BL
GY MAIN CIRCUIT BREAKER READY TO BE CLOSED

BL STATOR FILTER FUSES STATUS


We reserve all rights in this document and in the information contained therein.

D RD STATOR FILTER FUSES STATUS D


601

201
602

603

606

604

200
193
=G14+CONV/3.E4

=G14+CONV/3.E5

=G14+CONV/3.E5

=G14+CONV/3.E5

=G14+CONV/3.E5

=G14+CONV/3.E5

=G14+CONV/3.E5

=G14+CONV/3.E6

E E

d c b a d c b a

*Cable entry view (Aerial connector view) *Cable entry view (Aerial connector view)
Alstom.

24V SIGNALS TO CONVERTER

F F
03 01 27-05-2014 XAF PGG MO EC-00228 Galileo; EC00217 Typhoon System Des. XAF Drawing Nº: SUPPLY: Modify.: 03
03 01 28-03-2014 XAF PGG MO EC-00225 Draw.15100238 deleted article ECO100 Platform V3 15000032 15100095
Comp. PGG Version: 01
03 00 13-01-2014 XAF PGG MO EC-11936 Update V3 24V SIGNALS TO CONVERTER Apr. MO Art. :
02 01 19-10-2012 XAF PGG MO EC-10226 Mistakes =G15 +PC
Modif. Vers. Date Des. Comp. Apr. Observations POWER CABINET Date 27-05-2014 Sheet 9 340 Sh.

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

A A

B B

20
21
22
23
24
25
26
14
16
17
18
19
-XPC-1-24VDC

C C

12
13
14
11
-XPC-1-UPS-230VAC
Reproduction, use or disclosure to third parties without express authority is strictly forbidden.

20
21
22
15
16
17
18

19

-XPC-1-230VAC
We reserve all rights in this document and in the information contained therein.

D D

E E
Alstom.

F F
03 01 27-05-2014 XAF PGG MO EC-00228 Galileo; EC00217 Typhoon System Des. XAF Drawing Nº: SUPPLY: Modify.: 03
03 01 28-03-2014 XAF PGG MO EC-00225 Draw.15100238 deleted article ECO100 Platform V3 15000032 15100095
Comp. PGG Version: 01
03 00 13-01-2014 XAF PGG MO EC-11936 Update V3 TERMINAL SPARE Apr. MO Art. :
02 01 19-10-2012 XAF PGG MO EC-10226 Mistakes =G15 +PC
Modif. Vers. Date Des. Comp. Apr. Observations POWER CABINET Date 27-05-2014 Sheet 10 340 Sh.

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

A A

-WPE1
-WPE1 -WPE1 -WPE1 -WPE1 -WPE1
2
9 10 11 13 14
/1.C8
/7.A4 /11.B4 /11.B3 /11.B5 /11.B4 /1.C2 /1.C2 /11.B7 /11.B6 /11.B1

B B

-WPE1 -WPE1 -WPE1 -WPE1


15 16 17 19
/11.B7 /11.B2 /11.B1 /11.B3 /11.B2 /1.E6 /1.E6 /1.E5

C C
Reproduction, use or disclosure to third parties without express authority is strictly forbidden.
We reserve all rights in this document and in the information contained therein.

D D

E E
Alstom.

F F
03 01 27-05-2014 XAF PGG MO EC-00228 Galileo; EC00217 Typhoon System Des. XAF Drawing Nº: SUPPLY: Modify.: 03
03 01 28-03-2014 XAF PGG MO EC-00225 Draw.15100238 deleted article ECO100 Platform V3 15000032 15100095
Comp. PGG Version: 01
03 00 13-01-2014 XAF PGG MO EC-11936 Update V3 RESERVED GROUND PLATES Apr. MO Art. :
02 01 19-10-2012 XAF PGG MO EC-10226 Mistakes =G15 +PC
Modif. Vers. Date Des. Comp. Apr. Observations POWER CABINET Date 27-05-2014 Sheet 11 340 Sh.

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

A A

B B

C C
Reproduction, use or disclosure to third parties without express authority is strictly forbidden.
We reserve all rights in this document and in the information contained therein.

D D

E E
Alstom.

F F
03 01 27-05-2014 XAF PGG MO EC-00228 Galileo; EC00217 Typhoon System Des. XAF Drawing Nº: SUPPLY: Modify.: 03
03 01 28-03-2014 XAF PGG MO EC-00225 Draw.15100238 deleted article ECO100 Platform V3 15000032 15100095
Comp. PGG Version: 01
03 00 13-01-2014 XAF PGG MO EC-11936 Update V3 SPARE Apr. MO Art. :
02 01 19-10-2012 XAF PGG MO EC-10226 Mistakes =G15 +PC
Modif. Vers. Date Des. Comp. Apr. Observations POWER CABINET Date 27-05-2014 Sheet 12 340 Sh.

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

FRONT VIEW LEFT VIEW

A A
*Pos.40

B B

*Pos.3

*Pos.1 *Pos.6 *Pos.32 *Pos.7


C C
Only UL Option
Reproduction, use or disclosure to third parties without express authority is strictly forbidden.
We reserve all rights in this document and in the information contained therein.

D D

E E
Alstom.

*Label ID related to corresponding INF label (See it on BOM)

F F
03 01 27-05-2014 XAF PGG MO EC-00228 Galileo; EC00217 Typhoon System Des. XAF Drawing Nº: SUPPLY: Modify.: 03
03 01 28-03-2014 XAF PGG MO EC-00225 Draw.15100238 deleted article ECO100 Platform V3 15000032 15100095
Comp. PGG Version: 01
03 00 13-01-2014 XAF PGG MO EC-11936 Update V3 CABINET EXTERNAL VIEW Apr. MO Art. :
02 01 19-10-2012 XAF PGG MO EC-10226 Mistakes =G15 +PC
Modif. Vers. Date Des. Comp. Apr. Observations POWER CABINET Date 27-05-2014 Sheet A1 340 Sh.

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

RIGHT VIEW FRONT VIEW LEFT VIEW

A A

-KA1.1
-KA1.2
-KA1.4
-KA1.5
-KA1.3
-Q1.4 -Q1.6 -CD1
21 11 21 11 21 11
1 3 1 3
13
1 3 5 7N -B1.0 -B1.1 -B1.2 -B1.3
22 12 22 12 22 12

24 14 24 14 24 14
42 12
A1 21
90
44 14 80

-M01
70 40
-10...50ºC/14...122ºF 60 50
-M1.1 -M1.2

-M01
0...60ºC/32...140ºF -10...50 ºC/14...122 ºF
230Vac 25 A 20....80ºC/68...176ºF35...95%
Reg.:35ºC/95ºF
Reg.:10ºC/50ºF 230Vac 230Vac
41 11
3A 22
30 mA Reg.:60ºC/140ºF Reg.:35ºC/95ºF 64 W 64 W
1 2 11 12 23 24 2 L 3 1 2
A1 A1 A1 A2 A2 A1
A2 2 4 2 4 6 8N
A2 A2 A2 2 4 14

-CD2
5357 103 107 111 115

5256 102 106 110 114

2 4 6 8

400VAC
5155 101 105 109 113
1 3 5 7

230VAC

230VAC

230VAC
-XPC-1-UPS-
-XPC-

24VDC

24VDC
-XPC-2-

-XPC-2-

-XPC-1-

-XPC-1-
5054 100 104 108 112
1 3 5 7 9 1113 1 3 5 7 9 1113 15171921 1 3 5 7 9 1113151719 212325

2 4 6 8 10 1214 2 4 6 8 101214 16182022 2 4 6 8 101214161820 222426

5054 100 104 108 112


L NPE L NPE

-CD3

-E1.1

-CD4

-CD5
POLYLUX POLYLUX POLYLUX POLYLUX POLYLUX
1.200W

B 1000 V / 400 V
10VA
1000 V / 400 V
10VA
1000 V / 400 V
10VA
1000 V / 400 V
10VA
1000 V / 400 V
10VA
5,2A.
B
-T1.1 -T1.2 -T1.6 -T1.7 -T1.8
31725 31725 31725 31725 31725

Arc Monitor Option

POLYLUX
1000 V / 400 V
10VA

-T1.9 -T1.3 -T1.4 -T1.5


31725
P2 P2 P2

S1 S2 S1 S2 S1 S2

P1 P1 P1

Protection 1 *Pos.22

1 3 5

-F1.1 -F1.10
21373 21373
C 1 3 5 1 3 5
A1
C
43
125A 125A *Pos.2
F:0.8A gBR F:0.8A GBR A2 ABB - AF2050 *Pos.5 *Pos.6
31 *Pos.37
-KM1.1
32

44
Only UL Option
23367

13

21

22

14
2 4 6 2 4 6

*Pos.46

2 4 6
Reproduction, use or disclosure to third parties without express authority is strictly forbidden.

-F1.11
21373
Only UL Option
1 3 5

125A
F:0.8A GBR
We reserve all rights in this document and in the information contained therein.

1 C11 D1 C1 C12 D2 C2 14 U2 3 95 24 13 U1 98 23 37 38 5

D D

2 4 6
ABB SACE E3

Protection 2 *Pos.22

-F1.2
21375
1 3 5
250A
F:100A

11

1214

2 4 6
2 4 6

-E1.2

E 1.200W
5.2 A
E
-F1.3 -F1.4 -F1.5
L1 PE L1 PE L1 PE

Protection 3 *Pos.22
L3 L2 L1
-M02

PE PE

14 11 12

21397
PE PE PE
-F1.6
-W1.1
Alstom.

20 18 16 14 11 9 6
21 19 17 15 13 12 10 8 6 5 4 3 2

-WPE1

CABINET: 2200x800x600
*Label ID related to corresponding INF label (See it on BOM)
F F
03 01 27-05-2014 XAF PGG MO EC-00228 Galileo; EC00217 Typhoon System Des. XAF Drawing Nº: SUPPLY: Modify.: 03
03 01 28-03-2014 XAF PGG MO EC-00225 Draw.15100238 deleted article ECO100 Platform V3 15000032 15100095
Comp. PGG Version: 01
03 00 13-01-2014 XAF PGG MO EC-11936 Update V3 CABINET INTERNAL VIEW Apr. MO Art. :
02 01 19-10-2012 XAF PGG MO EC-10226 Mistakes =G15 +PC
Modif. Vers. Date Des. Comp. Apr. Observations POWER CABINET Date 27-05-2014 Sheet A2 340 Sh.

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

ROOF
ROOF BACK PLATE
A 200mm A
STRUCTURE

SIDE
MOUNTING PLATE

MOUNTING PLATE
B B

C C

MOUNTING PLATE
MOUNTING PLATE
MOUNTING PLATE
MOUNTING PLATE
Reproduction, use or disclosure to third parties without express authority is strictly forbidden.
We reserve all rights in this document and in the information contained therein.

D D
MOUNTING PLATE

GROUND PLATES
MOUNTING PLATE

E -WPE1 E
5
STRUCTURE

300mm

BACK PLATE
/1.C7 /2.C1
200mm

STRUCTURE 200mm
200mm
CABLE ENTRY PLATE 200mm
SIDE
Alstom.

200mm 300mm CABINET DOOR CABINET DOOR

F F
03 01 27-05-2014 XAF PGG MO EC-00228 Galileo; EC00217 Typhoon System Des. XAF Drawing Nº: SUPPLY: Modify.: 03
03 01 28-03-2014 XAF PGG MO EC-00225 Draw.15100238 deleted article ECO100 Platform V3 15000032 15100095
Comp. PGG Version: 01
03 00 13-01-2014 XAF PGG MO EC-11936 Update V3 CABINET GROUNDING Apr. MO Art. :
02 01 19-10-2012 XAF PGG MO EC-10226 Mistakes =G15 +PC
Modif. Vers. Date Des. Comp. Apr. Observations POWER CABINET Date 27-05-2014 Sheet A3 340 Sh.

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

Bill of materials
A A
Higher Level Assignment: =G15 Location designation: +PC

Pos. No. Ref. or Drawing nº Art. Description Manufacturer Device designation


1 1 14100161-00 - Temperature switch 1NC (0...+60ºC/+32...+140 ºF), 250 Vac 10A, DC30W, IP20 - -B1.0

2 1 14100160-00 - Temperature switch 1NC (-10...+50ºC/+14...+122ºF) + 1NO (+20....+80ºC/+68...+176ºF), 230 Vac 10A, DC30W, IP20 - -B1.1
B B
3 1 01220.0-00 22136 Adjustable mechanical hygrostat 35 ... 95% RH, AC/DC 20V - AC 250V 50/60Hz, 20W, 5 (1) A, IP20, UL STEGO -B1.2

4 1 14100159-00 - Temperature switch 1NC (-10...+50 ºC/+14...+122 ºF) 230 Vac 10A, DC 30W, IP20 - -B1.3

5 1 14200186-05 25195-05 DIN Rails PC ECO100 Cabinet - -E1

6 1 14200187-04 25197-04 PC-400V Cabinet conduits - -E1

7 1 14200272-00 32310 Closet door opening restrictor - -E1

8 1 15100226-00 54501 Switch-Contactor interconnection plate R front -E1

C 9 1 15100227-00 54502 Switch-Contactor interconnection plate S front -E1 C

10 1 15100228-00 54503 Switch-Contactor interconnection plate T front -E1

11 1 15100229-00 54504 Switch-Contactor interconnection plate R rear -E1

12 1 15100230-00 54505 Switch-Contactor interconnection plate S rear -E1


Reproduction, use or disclosure to third parties without express authority is strictly forbidden.

13 1 15100231-00 54506 Switch-Contactor interconnection plate T rear -E1

14 1 15100232-00 54507 Output contactor plate R external -E1


We reserve all rights in this document and in the information contained therein.

D 15 1 15100233-00 54508 Output contactor plate S external -E1 D

16 1 15100234-00 54509 Output contactor plate T external -E1

17 1 15100235-00 54510 Output contactor plate R internal -E1

18 1 15100236-00 54511 Output contactor plate S internal -E1

19 1 15100237-00 54512 Output contactor plate T internal -E1

20 1 15100240-00 54631 PC Lower mounting plate -E1

21 1 15100241-00 54632 PC Breaker mounting plate left -E1


E E
22 1 15100242-00 54633 Upper mounting plate PC -E1

23 1 15100243-00 54634 PC Mounting plate contactor support -E1

24 1 15100244-00 - Assembly background plate front cabinet cable entry -E1


Alstom.

25 1 15100245-00 - Assembly background plate intermediate cabinet cable entry -E1

26 1 15100246-00 - Assembly background plate rear cabinet cable entry -E1

F F
03 01 27-05-2014 XAF PGG MO EC-00228 Galileo; EC00217 Typhoon System Des. XAF Drawing Nº: SUPPLY: Modify.: 03
03 01 28-03-2014 XAF PGG MO EC-00225 Draw.15100238 deleted article ECO100 Platform V3 15000032 15100095
Comp. PGG Version: 01
03 00 13-01-2014 XAF PGG MO EC-11936 Update V3 ASSIGNED MATERIAL -1 Apr. MO Art. :
02 01 19-10-2012 XAF PGG MO EC-10226 Mistakes =G15 +PC
Modif. Vers. Date Des. Comp. Apr. Observations POWER CABINET Date 27-05-2014 MAT1 340

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

Bill of materials
A A
Higher Level Assignment: =G15 Location designation: +PC

Pos. No. Ref. or Drawing nº Art. Description Manufacturer Device designation


27 1 20200093-01 41895-01 PC protection methacrylates - -E1

28 1 5ST3 801 23808 Locking device for switches 5J6, 5SY and 5SP4 SIEMENS -E1
B B
29 1 5ST3 801-1 23806 Locking device for switch 5SU1 SIEMENS -E1

30 1 INF-12949 - Labels for cabinets and boxes ECO100 (only labels corresponding to the cabinet) - -E1

31 1 SA1 50150 Locking device for switches S 200, SN 201, F 200, DS 200 ABB -E1

32 1 VC1-1 18627 Corrosion inhibitor capsule Zerust 30 cm EXVC1-1 ZERUST -E1

33 1 15100092-03 30913-03 PC Enclosure machined, door, chassis, wall, mounted components - -E1

34 12 TUE DIN934-M12 26069 M12 DIN934 nut INDUTOR -E1(12)

C 35 2 14000066-01 33114-01 Heating resistance support - -E1(2) C

36 2 14200189-02 25199-02 Suport Q1.1 PC_e100 -E1(2)

37 2 556660 24445 Earthing strap 300mm ERICO -E1(2)

38 24 AR00120 21018 Conical spring washer DIN-6796 WOHNELEC -E1(24)


Reproduction, use or disclosure to third parties without express authority is strictly forbidden.

39 3 15100224-00 54499 Switch plate lower front R-S-T -E1(3)

40 3 15100225-00 54500 Switch plate lower rear R-S-T -E1(3)


We reserve all rights in this document and in the information contained therein.

D 41 3 KSERIES-K20 20897 Security padlock + key KSERIES-K20 IFAM -E1(3) D

42 6 12840 54602 Bolt and Nut Protection Caps M12 MOSS -E1(6)

43 6 556640 37157 Earthing strap 200mm ERICO -E1(6)

44 6 TOR-DIN-933-M12x50 18902 Screw hexagonal head M12X50 DIN 933 C8,8 zinc. - -E1(6)

45 6 TOR-DIN-933-M12x60 888 Screw hexagonal head M12X60 DIN 933 C8,8 zinc. - -E1(6)

46 9 548510 25115 Fixation insulator 40mm M8 ERICO -E1(9)

47 2 13060.0-01 23412 Compact heating resistance without thermostat, 230V 50/60Hz, 1200W, 5.2A, IP20. STEGO -E1.1, -E1.2
E E
48 9 E075743 21749 Cylindrical fuse 0.8 A, 1000Vdc CP gRB, 20x127 FERRAZ -F1.1(3), -F1.10(3), -F1.11(3)

49 3 H097228A 21373 Base triple pole drawout 1kV 125A, 20x127 FERRAZ -F1.1, -F1.10, -F1.11

50 1 P220077A 21375 Base triple pole drawout 1kV 250A, 27x60 PRE+MC PS FERRAZ -F1.2
Alstom.

51 3 M081293C 21374 Cylindrical fuse 100 A, 1000 V, 27x60 with fuse indicator FERRAZ -F1.2(3)

52 3 961 175 23552 1-pole surge discharger, 760V, 25kV CA, Class I DEHN -F1.3, -F1.4, -F1.5

F F
03 01 27-05-2014 XAF PGG MO EC-00228 Galileo; EC00217 Typhoon System Des. XAF Drawing Nº: SUPPLY: Modify.: 03
03 01 28-03-2014 XAF PGG MO EC-00225 Draw.15100238 deleted article ECO100 Platform V3 15000032 15100095
Comp. PGG Version: 01
03 00 13-01-2014 XAF PGG MO EC-11936 Update V3 ASSIGNED MATERIAL -2 Apr. MO Art. :
02 01 19-10-2012 XAF PGG MO EC-10226 Mistakes =G15 +PC
Modif. Vers. Date Des. Comp. Apr. Observations POWER CABINET Date 27-05-2014 MAT2 340

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

Bill of materials
A A
Higher Level Assignment: =G15 Location designation: +PC

Pos. No. Ref. or Drawing nº Art. Description Manufacturer Device designation


53 1 952307 21397 Multi-pole surge discharger, 1kV AC, Class II, Tripolar DEHN -F1.6

54 1 G2R-2-SNI 230VAC 12030 220 V AC Relay with 2 inv. OMRON -KA1.1


B B
55 3 P2RF-08-E 12031 Base for 2-pole relays, switched G2R pluggable narrow OMRON -KA1.1, -KA1.2, -KA1.4

56 2 G2R-2-SNDI-24VDC 17865 24 V DC Relay with 2 inv. OMRON -KA1.2, -KA1.4

57 1 GHE3211102R0006 50143 Installation contactor for permanent drive. in AC with pos. indicator; 230 VAC 20A 2NO ctrl: 230VAC ABB -KA1.3

58 1 PYF08A-N 35971 Base for 2-pole relays, switched MY2N pluggable OMRON -KA1.5

59 1 MY2N-CR 35963 220 V AC Relay with 2 inv. (max.10A) OMRON -KA1.5

60 1 15100248-00 54753 Polycarbonate protection for gas output -KM1.1

C 61 1 1SFN010720R1011 23374 Auxiliary contact block 1NO+1NC for contactors AF 2050 ABB -KM1.1 C

62 1 1SFL707001R7011 23367 CONTACTOR STATOR, AC-1000 V, 1NO-1NC, AC 100-250 V, 50/60 HZ, 3-POLE ABB -KM1.1

63 2 11803.0-00 36405 Cabinet filter 250x250x22 STEGO -M1.1, -M1.2

64 2 01805.0-07 26121 Fan motor with filter, Mod. FF 018, flow 300m3 w. filter, 230 Vca, 50Hz, 64 W, 250x250x107 STEGO -M1.1, -M1.2
Reproduction, use or disclosure to third parties without express authority is strictly forbidden.

65 1 1SDA076906R1 55300 E3V-A2000 PR121/P-LSIG 2000A 3p F HR+ACC Main Switch ABB -Q1.1

66 1 5SY6203-7 21395 Circuit breaker 3A II - 6 kA - C SIEMENS -Q1.4


We reserve all rights in this document and in the information contained therein.

D 67 1 5ST3 010 11765 1NO+1NC Auxiliary switch for 5SY & 5SP 4 circuit breakers SIEMENS -Q1.4 D

68 1 F204AC-25/0.03 50141 Differential switch 25A 30 mA IV protection AC ABB -Q1.6

69 1 3SE5000-0AA11-1AJ0 54571 Roller lever SIEMENS -S1.0

70 1 3SE5000-0AH00-1AJ0 54570 Metal actuator head SIEMENS -S1.0

71 1 3SE5112-0LA00-1AJ0 54569 Limit switch 1NO+2NC SIEMENS -S1.0

72 6 TM1005AR 31725 Single-phase measurement transformer 1000V / 400V ac; 10 VA; 50/60 Hz REINFORCED INSULATION POLYLUX -T1.1, -T1.2, -T1.6, -T1.7, -T1.8, -T1.9

73 3 TC10 2000/1A 30VA CL 0.5 17374 Intensity transformer 2000/1A: 30VA; type: 0,5 CIRCUTOR -T1.3, -T1.4, -T1.5
E E
74 1 900 411 23628 Bridge for wiring 3P 125A DEHN -W1.1

75 1 15100238-00 - Assembly PC Ground plates -WPE1

76 2 15100247-00 54640 Land support plate -WPE1(2)


Alstom.

77 1 15100239-00 54596 PC TERMINAL -XPC-1-230VAC(22), -XPC-1-24VDC(26)

-XPC-1-UPS-230VAC(14), -XPC-2-230VAC(8)

F F
03 01 27-05-2014 XAF PGG MO EC-00228 Galileo; EC00217 Typhoon System Des. XAF Drawing Nº: SUPPLY: Modify.: 03
03 01 28-03-2014 XAF PGG MO EC-00225 Draw.15100238 deleted article ECO100 Platform V3 15000032 15100095
Comp. PGG Version: 01
03 00 13-01-2014 XAF PGG MO EC-11936 Update V3 ASSIGNED MATERIAL -3 Apr. MO Art. :
02 01 19-10-2012 XAF PGG MO EC-10226 Mistakes =G15 +PC
Modif. Vers. Date Des. Comp. Apr. Observations POWER CABINET Date 27-05-2014 MAT3 340

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

Bill of materials
A A
Higher Level Assignment: =G15 Location designation: +PC

Pos. No. Ref. or Drawing nº Art. Description Manufacturer Device designation


-XPC-2-24VDC(16), -XPC-400VAC(8)

B B

C C
Reproduction, use or disclosure to third parties without express authority is strictly forbidden.
We reserve all rights in this document and in the information contained therein.

D D

E E
Alstom.

F F
03 01 27-05-2014 XAF PGG MO EC-00228 Galileo; EC00217 Typhoon System Des. XAF Drawing Nº: SUPPLY: Modify.: 03
03 01 28-03-2014 XAF PGG MO EC-00225 Draw.15100238 deleted article ECO100 Platform V3 15000032 15100095
Comp. PGG Version: 01
03 00 13-01-2014 XAF PGG MO EC-11936 Update V3 ASSIGNED MATERIAL -4 Apr. MO Art. :
02 01 19-10-2012 XAF PGG MO EC-10226 Mistakes =G15 +PC
Modif. Vers. Date Des. Comp. Apr. Observations POWER CABINET Date 27-05-2014 MAT4 340

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

Bill of materials
A A
Higher Level Assignment: =G15 Location designation: +PC.WOODWARD VARIANT

Pos. No. Ref. or Drawing nº Art. Description Manufacturer Device designation


1001 3 2038608.100 32295 Blade fuse with firing pin, curve aM 100A 1000Vac size 000 NH 25kA SIBA -F1.7, -F1.8, -F1.9

1002 3 2138601 32296 Blade fuse base, single phase, 100A 1000Vac Size 000 Type NH SIBA -F1.7, -F1.8, -F1.9
B B
1003 3 2800202 32355 Standard NA/NC auxiliary Contact SIBA -F1.7, -F1.8, -F1.9

C C
Reproduction, use or disclosure to third parties without express authority is strictly forbidden.
We reserve all rights in this document and in the information contained therein.

D D

E E
Alstom.

F F
03 01 27-05-2014 XAF PGG MO EC-00228 Galileo; EC00217 Typhoon System Des. XAF Drawing Nº: SUPPLY: Modify.: 03
03 01 28-03-2014 XAF PGG MO EC-00225 Draw.15100238 deleted article ECO100 Platform V3 15000032 15100095
Comp. PGG Version: 01
03 00 13-01-2014 XAF PGG MO EC-11936 Update V3 ASSIGNED MATERIAL WOODWARD VARIANT Apr. RP Art. :
02 01 19-10-2012 XAF PGG MO EC-10226 Mistakes =G15 +PC.WOODWARD VARIANT
Modif. Vers. Date Des. Comp. Apr. Observations POWER CABINET Date 27-05-2014 MAT5 340

1 2 3 4 5 6 7 8

You might also like