I BASIC INSPECTION PERIODIC INSPECTION 1600 JAM
A. PILOTS COMPARTMENT
1 PILOTAND CO PILOT OXYGEN SYSTEM
6 RUDDER PEDALS
Inspect for condition and freedom of
8 Mhr
movement
7 MASTER BRAKE CYLINDERS
Clean piston rod surfaces and upper surface
of cylinder bodies. Inspect for security and 12 Mhr
condition
8 PILOT’S AND COPILOT’S SEATS
Inspect for damage to upholstery, safety
belts and operation of safety belt inertial
8 Mhr
reels. Inspect seat adjusting mechanisms
for proper locking
9 PLACARDS AND DECALS
Inspect for security, presence and legibility
8 Mhr
10 ELECTRICAL COMPONENTS (Accessible
without interior disassembly)
B. CABIN SECTION
1 DIVIDER
Inspect for wear and other physical damage
8 Mhr
2 REFRESHMENT CENTER AND
STORAGE CABINETS
Inspect for security and damage (If Installed)
8 Mhr
3 PASSENGER SEATING
a Inspect for damage to upholstery, safety
belts and operation of safety belt inertia 8 Mhr
reels (If Installed)
b Inspect shoulder harness attachment post
(If Installed) for worn or missing grimmet
8 Mhr
and seat beltsfor worn of missing
components.
c Inspect base rail attach fittings for
8 Mhr
deformation and/cracks
4 SEAT RAIL ATTACHMENT
Inspect for corrosion, loose or failed
fasterners and evidence of structural 8 Mhr
damage
5 FLOOR PANELS
Inspect for corrosion and evidence of
8 Mhr
structural damage
6 PORTABLE FIRE EXTINGUISHER
Inspect for normal operationg pressure,
8 Mhr
signs of damage and mount security
7 INTERIOR LIGHTS
Inspect all for security of installation,
8 Mhr
cracked lense and operation
8 OXYGEN
a Check operation of manual release system.
Perform PASSENGER OXYGEN SYSTEM 8 Mhr
CHECK.
b Inspect masks and hoses for security,
proper stowage, deterioration and damage 8 Mhr
g LATCHING MECHANISM
Inspect for condition and proper operation
8 Mhr
10 ENTRANCE DOOR AND STEPS (External
inspection with no trim panel removal
required)
Visually inspect for cracks, loose or failed
fasteners and any indication of structural
8 Mhr
damage, condition and proper operation
C PILOT/CABIN SECTION
1 AUXILIARY FUSELAGE FUEL TANKS
Inspect security of attachment, loose or
8 Mhr
failed fasteners and condition
2 MOISTURE DRAIN HOLES AND VALVES
12 ELECTRICAL WIRING
Inspect for security, deterioration, chafing
8 Mhr
and any indications of damage
13 Lubricate items as specified in chapter 12
36 Mhr
D FORWARD FUSELAGE
1 PLACARDS AND DECALS
NO URAIAN PART NUMBER QUANTITY KET
10 OXYGEN SYSTEM
a Service to full pressure. Inspect bottle,
plumbing and valve for condition, security 16 Mhr
and indication of damage.
b Inspect oxygen sevice door, hinge and latch
for proper operation and evidence of 8 Mhr
damage.
11 FORWARD PRESSURE BULKHEAD
Detail inspect for cracks, failed fasteners,
corrosion and evidence of structural 16 Mhr
damage
12 NITROGEN SYSTEM
Service to full pressure. Inspect bottle,
plumbing and valve for condition, security 16 Mhr
and indication of damage
13 AOA TRANSMITTER PROBE
Inspect for cleanliness of air inlet ports (if
cone-type probe), evidence of overheating
8 Mhr
or damage and freedom of probe rotation
E MIDFUSELAGE
1 PASSENGER COMPARTMENT
WINDOWS
Inspect for cracks and delamination 32 Mhr
2 BRAKE SYSTEM
Inspect power brake valve, parking brake
valves, accumulator and pluming for leaks,
32 Mhr
security, chafing and routing. Check
accumulator precharge
3 PLACARDS AND DECALS
Inspect for security, presence and legibility
8 Mhr
4 FUEL STORAGE AREA
Inspect for leaks. Check the underside of
the fuselage for fuel stain, discoloration and
32 Mhr
evidence of leakade
F LEFT-HAND WING
1 PLACARDS AND DECALS
Inspect for security, presence and legibility
8 Mhr
2 WING SKIN (Exterior inspection only, fairing
removal is not required)
Inspect skin for cracks, loose or failed
8 Mhr
fasteners and evidence of damage
3 WING ACCESS PANELS (Exterior
inspection only panel removal is not
required)
Inspect for security, installation and
8 Mhr
evidence of damage
4 FUEL TANK FILLER
Inspect for damage or broken components
and checking loked position of filler caps 8 Mhr
a Vent Valves
Inspect for condition and security 8 Mhr
b Vent Tubes and Hoses
Inspect for condition, security and bonding
8 Mhr
provisions for security
27 WING OVERPRESSURE SWITCH
Remove and perfoorm WING
32 Mhr
OVERPRESSURE SWITCH TEST
28 PRESSURE RELIEF VALVE (Collector
Tank)
Check for security and proper operation
16 Mhr
(ensure valve opens at 2 psi)
29 LOW LEVEL SWITCH (Collector Tank)
Inspect for operation and security 8 Mhr
30 FUEL COLLECTOR TANK STRUCTURE
Inspect for cracks, loose or missing
fasteneers and evidence of structural 16 Mhr
damage
31 LEFT SPOILER BRACKET SUPPORT
FITTING (P/N 45A62036)
Visually inspect for cracks and any other
indications of structural damage. 8 Mhr
(Disassembly is not required).
32 LEVEL CONTROL SHUT-OFF VALVE (P/N
1323-518100M2)
Inspect for leaks, security and smooth float
movement. Ensure presence of washers
32 Mhr
under the shutoff valve mounting bolts
33 FUEL TANKS
Detail inspect the tank interiors for
indications of fungal or microbial 48 Mhr
contamination
34 Lubricate items as specified in chapter 12
64 Mhr
G RIGHT-HAND WING
1 PLACARDS AND DECALS
Inspect for security, presence and legibility
8 Mhr
2 WING SKIN (Exterior inspection only, fairing
removal is not required)
Inspect skin for cracks, loose or failed
8 Mhr
fasteners and evidence of damage
3 WING ACCESS PANELS (Exterior
inspection only panel removal is not
required)
Inspect for security, installation and
8 Mhr
evidence of damage
4 FUEL TANK FILLER
Inspect for damage or broken components
and checking loked position of filler caps 8 Mhr
33 FUEL TANKS
Detail inspect the tank interiors for
indications of fungal or microbial 48 Mhr
contamination
34 Lubricate items as specified in chapter 12
64 Mhr
I AFT FUSELAGE
1 PLACARDS AND DECALS
Inspect for security, presence and legibility
8 Mhr
2 EXTERNAL POWER RECEPTACLE AND
DOOR
Inspect receptacle for attachment, security
and corrosion. Inspect door for conditioin 16 Mhr
and proper latch operation
3 REAR FUSELAGE DOOR AND
FUSELAGE DOOR SEALS
Inspect door and seals for condition and
8 Mhr
proper latch operation
4 FUEL TANK FILLER AND DOOR
Inspect for damage or broken components
and check locked position of filler cap 8 Mhr
12 ELECTRICAL COMPONENTS
Visually inspect for security of installation,
electrical connection and condition. Also
inspect power junction boxes, wiring and
16 Mhr
terminals for security of connection,
evidence of overheating, damage and
deterioration
13 HYDRAULIC FILTER ELEMENTS
Replace 8 Mhr
14 HYDRAULIC PACKAGE AIR FILTER
Clean 4 Mhr
15 HYDRAULIC SYSTEM PLUMBING,
COMPONENTS AND OUNTS
Inspect for security, leaks, chafing of
8 Mhr
damage
NO URAIAN PART NUMBER QUANTITY KET
40 ANTENNA
Inspect antennas and fillet seal for cracks,
corrosion, burns, security and evidence of 8 Mhr
damage
41 FUEL TANKS
NO URAIAN PART NUMBER QUANTITY KET
J VERTICAL STABILIZER
1 VERTICAL STABILIZER (Exterior
inspection only)
Inspect for cracks, loose or failed fasteners
and any indication of structural damage 8 Mhr
12 RUDDER OPERATION
Perform OPERATIONAL TEST and FULL
DEFLECTION LENGTH CHECK procedure 32 Mhr
K HORIZONTAL STABILIZER
1 HORIZONTAL STABILIZER SKIN AND
LEADING EDGE (Exterior inspection only)
14 ELECTRICAL HARNESS
Inspect connectors, terminals and wires for
condition, chafing, security and routing 16 Mhr
15 STARTER-GENERATOR (Generator
removal is not necessary)
a Inspect for security, visible damage and
4 Mhr
instalation.
b Inspect brushes for cracks and wear. 4 Mhr
c Inspect commutator and electrical
connections for security, wear, deterioration 4 Mhr
and damage
16 HYDROMECHANICAL UNIT (HMU)
Inspect for security and leakage 8 Mhr
17 ENGINE FUEL PUMP INLET SCREEN
(Not Installed on JT15D-5R engines)
Check for foreign matter and distortion.
32 Mhr
Clean and reinstall
18 ENGINE FUEL PUMP OUTLET FILTER
ELEMENT
Replace 16 Mhr
19 COMBUSTION CHAMBER DRAIN VALVE
14 ELECTRICAL HARNESS
Inspect connectors, terminals and wires for
condition, chafing, security and routing 16 Mhr
15 STARTER-GENERATOR (Generator
removal is not necessary)
a Inspect for security, visible damage and
4 Mhr
instalation.
b Inspect brushes for cracks and wear. 4 Mhr
c Inspect commutator and electrical
connections for security, wear, deterioration 4 Mhr
and damage
16 HYDROMECHANICAL UNIT (HMU)
Inspect for security and leakage 8 Mhr
17 ENGINE FUEL PUMP INLET SCREEN
(Not Installed on JT15D-5R engines)
Check for foreign matter and distortion.
32 Mhr
Clean and reinstall
18 ENGINE FUEL PUMP OUTLET FILTER
ELEMENT
Replace 16 Mhr
19 COMBUSTION CHAMBER DRAIN VALVE
7 ACTUATOR
Inspect for hydraulic leaks, damaged
pushrod, damaged flexible hoses and 16 Mhr
security of installation
8 DEPLOY AND STOW LIMIT SWITCH
Inspect for security of installation and
damage electrical components. Perform
16 Mhr
THRUST REVERSER STOW LIMIT
SWITCHES CHECK
9 THROTTLE FEEDBACK CABLE
Inspect for security of installation, wear,
freedom of movement, evidence of damage 8 Mhr
and safetying
10 FEEDBACK BRACKET ASSEMBLY
Inspect for security of installation, alignment
and evidence of damage. Inspect the lever
8 Mhr
and spindle for wear and alignment
11 THRUST REVERSER
Perform NORMAL THRUST REVERSER
SYSTEM CHECK and EMERGENCY 32 Mhr
STOW SYSTEM TEST
12 Lubricate items as specified in chapter 12
48 Mhr
1 HYDRAULIC LINE
Inspect for hydraulic leaks, cleanliness,
8 Mhr
security of installation and condition
2 UPPER AND LOWER DOORS
Inspect for cracks, evidence of door twisting,
loose or failed fasteners, faired position of
32 Mhr
the doors and security of installation.
Measure pad thickness
3 STANGS AND DOORS
Perform the UNPAINTED SURFACE
8 Mhr
INSPECTION
4 FAN DUCT ASSEMBLY
Inspect for cracks, security and damage to
components attached and security of 32 Mhr
installation to the engine bypass flange
5 ACTUATING MECHANISM
Inspect support assemblies, carriage, links,
lever, cams, cam followers and support
bracket for cracks, evidence of damage,
32 Mhr
freedom of movement and security of
installation. Ensure driver-link attach bolt
does not rotate
6 ACTUATING MECHANISM
Check link bearings and door-bushing
ccarriage-guide rods, linkage pivot points
and cam follower for freeedomof 32 Mhr
rotation.Measure deflection of driver links
7 ACTUATOR
NO URAIAN PART NUMBER QUANTITY KET
11 THRUST REVERSER
Perform NORMAL THRUST REVERSER
SYSTEM CHECK and EMERGENCY 32 Mhr
STOW SYSTEM TEST
12 Lubricate items as specified in chapter 12
48 Mhr
P OPERATIONAL INSPECTIONS
1 COCKPIT ADVISORY, CAUTION AND
WARNING LIGHT
Inspect for security of installation and
8 Mhr
illumination
2 EMERGENCY LIGHTING SYSTEM
Move the EMER LT switch to the TEST/ON
position. Check lights are on, then return 4 Mhr
switch to the OFF position
3 EMERGENCY LIGHTING SYSTEM
Perform EMERGENCY LIGHTING
4 Mhr
SYSTEM OPERATIONAL INSPECTION
4 PITCH TRIM AND OUT-OF-POSITION
WARNING
Actuate emergency pitch trim switch and
check for audible warning tone and out-of- 8 Mhr
position warning
5 DOOR WARNING SYSTEM
Perform DOOR WARNING SYSTEM
8 Mhr
CHECK
6 WINDSHIELD HEAT
Perform OPERATIONAL TEST 8 Mhr
7 WINDSHIELD WIPERS
Flood windshield with water and check
wipers for proper operation. Inspect for 8 Mhr
blade damage or deterioration
8 PITOT, STATIC AND AOA SENSOR
Perform PITOT, STATIC AND AOA
HEATING SYSTEM OPERATIONAL 32 Mhr
CHECK
9 AUTOMATIC INVERTER SELECTION,
MANUAL INVERTER SELECTION AND
AUTOMATIC LOAD SHEDDING
Perform INVERTER SYSTEM
32 Mhr
FUNCTIONAL TEST
10 REFRIGERANT AIR-CONDITIONER
Verify 25 ± 5°F drop across both evaporator
coils. Check for proper operation of front
16 Mhr
and rear evaporator moisture drains
19 ENGINE SHUTDOWN
Check for proper operation 8 Mhr
B 6 Month Interval
MAIN BATTERY (SAFT NI-CAD SERIES),
perform regular check as identified in the
64 Mhr
saft component maintenance manual
IV ADDITIONAL WORK
1 ELT battery life limit due to time May 31th, Replace New
30 Mhr
2021
2 Life vest life limit due to time May 30th, Repair
52 Mhr
2021
3 Life raft life limit due to time May 30th, 2021 Repair
52 Mhr
4 First and Kid life limit due to time May 30th, Replace New
30 Mhr
2021
5 Cockpit portable fire extinguisher life limit Repair
52 Mhr
due to time Nov 08th, 2021
6 Cabin portable fire extinguisher life limit due Repair
52 Mhr
to time Nov 08th, 2021
7 FDR under water locator beacon life limit Replace New
52 Mhr
due to time May 30th, 2021
8 Flight Management FMC-5000 Card life limit Repair
52 Mhr
due to time May 30th, 2021
9 Oxygen cylinder life limit due to time May Repair
36 Mhr
30th, 2021
NO URAIAN PART NUMBER QUANTITY KET
V COMMISIONING
1 Techreps 2 Org
2 Inventory in 2 Org
3 Inventory Out 2 Org
4 Certification 2 Org
B MATERIAL
I BASIC MATERIAL
1 Fuel filter 651540 2 Ea Replace New
2 O Ring MS5988-1-912 1 Ea Replace New
3 Hydraulic Filter back up AN6235-3A 2 Ea Replace New
4 O Ring MS28775-136 1 Ea Replace New
5 Gasket 3017452 4 Ea Replace New
6 Oil filter 3073301-01 2 Ea Replace New
7 Packing AS-3209-140 2 Ea Replace New
8 Coaleser 180849-28 2 Ea Replace New
9 Packing M25988/1-904 1 Ea Replace New
10 Engine oil BP2380 1 Dus Replace New
11 Brush stargen 30300-1296 8 Ea Replace New
12 Igniter 9044810-1 4 Ea Replace New
13 Cabin press control filter 137847-1 1 Ea Replace New
14 Hydraulic filter 3070961-01 1 Ea Replace New
15 Filter evaporator 128-555114-1 1 Ea Replace New
16 Water separator coalescer 180849-28 1 Ea Replace New
17 Part kit filter/fuel pump 3070961-01 2 Ea Replace New
IV ADDITIONAL WORK
1 ELT battery 452-0133 1 Ea Replace New
2 Life vest PO1074-201 10 Ea Repair
3 Liferaft 710FAUL-1901-100 1 Ea Repair
4 First and kid 400-002 1 Set Replace New
5 Cockpit portable fire extinguisher C352TS 1 Ea Repair
6 Cabin portable fire extinguisher C352TS 1 Ea Repair
7 FDR battery DK120 1 Ea Replace New
8 Flight manajemen FMC-5000 card 822-0891-008 2 Ea Repair
9 Oxygen cylinder 176419-77 1 Ea Repair
10 Oxygen cylinder regulator 172400-14 1 Ea Repair
11 Main battery RG-380E/40 1 Ea Replace New
12 Engine fire cart 13083-5 4 Ea Replace New
13 FMS update Collins 1 Set Update
14 Pilot and co-pilot oxygen mask 174262-12 2 Ea Repair
V GENERAL CONSUMABLE
1 White color paint SIKKEN 30 Kg
2 Blue color paint SIKKEN 30 Kg
3 Orange color paint SIKKEN 10 Kg
4 Cleaner EXXON 2025 20 Ltr
5 Cleaner Remover TURCO STEPI 1 Can
6 Contact Cleaner LPS3 ELECT CLEANER 4 Can
7 Degreasing Agent/White Spirite COMERCIAL 5 Ltr
8 Tyrap MS3367–1–9 30 Ea
9 Tyrap MS3367–5–9 30 Ea
10 Tyrap MS3367–6–9 30 Ea
11 Locking Wire Ukuran 22 1 Roll
12 Locking Wire Ukuran 25 1 Roll
13 Locking Wire Ukuran 32 1 Roll
14 Locking Wire Ukuran 40 1 Roll
15 Contact Cleaner LPS3 CONTACT 4 Can
16 Contact Cleaner WD–40 5 Can
17 Lubricant WL–800 2 Ltr
NO URAIAN PART NUMBER QUANTITY KET
ttd
I JASA :
A BASIC INSPECTION PERIODIC INSPECTION 1600 JAM 7700 Mhrs
B SCHEDULE SPECIAL INSPECTION AND AFTER 6 YEARS 1096 Mhrs
C DEFECT FINDING 946 Mhrs
D ADDITIONAL WORK 645 Mhrs
E COMMISIONING 1 Pkt
II MATERIAL
A BASIC MATERIAL 1 Pkt
B SCHEDULE SPECIAL INSPECTION AND AFTER 6 YEARS 1 Pkt
C DEFECT FINDING 1 Pkt
D ADDITIONAL WORK 1 Pkt
E CONSUMABLE 1 Pkt
ttd