You are on page 1of 74

ZXSDR eNodeB Hardware

Structure
ZTE University
Objectives

 After this course, you will be able to:


 Know the ZXSDR eNodeB highlights

 Master the eNodeB technical specification


 Understand the eNodeB physical hardware
 Master the eNodeB network architecture and
configuration

 Know the eNodeB maintenance method


Contents

 eNodeB Overview
 ZXSDR B8200 L200 Hardware Structure
 ZXSDR R8882 Hardware Structure
 ZXSDR eNodeB Maintenance
LTE Base Station Family

Macro indoor base station BS8800

Macro outdoor base station BS8900A

BBU B8200

RRU R8882/R8862/R8972/R8964

Pico BS8912/BS8922

Femto BS8102

Qcell R8108

© ZTE Corporation. All rights reserved


eNodeB Location in the Network
Mobility Management Entity
Serving Gateway

MME/S-GW MME/S-GW
EPC

S1
Interface between EPS
MME/SGW & eNodeB

X2 E-UTRAN
eNB eNB
X2 X2
UE eNB
 Interface between
eNodeBs

eNodeB=BBU+RRU
Node B RNC eNodeB

© ZTE Corporation. All rights reserved


eNodeB System Structure: BBU + RRU

© ZTE Corporation. All rights reserved


ZXSDR eNodeB Functionality

Control Plane User Plane

S1/X2 interface management


Voice business

Cell management

UE management Data business

System information broadcast

Image business
Mobility management

© ZTE Corporation. All rights reserved


ZXSDR eNodeB Highlights

Large capacity

Mature and stable performance

Multi-standard and smooth evolution

Compact design and easy deployment

All-IP architecture

© ZTE Corporation. All rights reserved


Network Architecture

© ZTE Corporation. All rights reserved


ZTE Unified Radio Sub-System Platform
OneNetwork Target

GSM/EDGE UMTS/HSPA TD-SCDMA CDMA2000 WiMAX LTE


GSM/EDGE

ZTE Universal SDR Platform UMTS/HSPA

LTE

Distributed Integrated
Universal
RRU
RRU
RSU Features

 MicroTCA architecture
 Multi-Standard support
 Baseband sharing and
BBU software configurable
 RRU sharing and software
configurable
BBU

Future-Proof Platform with Smooth Evolution Support


© ZTE Corporation. All rights reserved
LTE Product Portfolio
INTEGRATED
Soft defined radio
2xMCPA, MIMO

2x40 W TOC power, 35%


Femto eNB BS8210
Multi-mode eNB Multi-mode eNB power efficiency for LTE
Outdoor BS8900 Indoor BS8800

BBU+RRU
All-IP transmission, provides
IP over E1/STM-1 interface

Unified O&M for


Multi-mode BBU Multi-mode BBU Multi-mode RRU simultaneous running RATs
Outdoor B8201 Indoor B8200 R8880/R8882

ZTE SDR PRODUCTS ADAPT TO TECHNOLOGY


DIVERSITIES TCO reduction comparing
with traditional solution
HSPA HSPA+ LTE

© ZTE Corporation. All rights reserved


SDR Benefits

Clearer and
Simpler Network

Lower Total Cost of Lower Investment


Ownership (TCO) Risk

© ZTE Corporation. All rights reserved


Contents

 eNodeB Overview
 ZXSDR B8200 L200 Hardware Structure
 ZXSDR R8882 Hardware Structure
 ZXSDR eNodeB Maintenance
Hardware Structure

 The ZXSDR B8200


TL200 is designed on
the basis of
MicroTCA (also
known as uTCA—a
flexible common
platform), which is
easy to be expanded.

© ZTE Corporation. All rights reserved


BBU Technical Specifications
Index Specification

Dimension 88.4 mm x 482.6 mm x 197 mm (Height x Width x Depth)


Weight • Typical configuration: 5.25 kg
• Maximal configuration: 7.5 kg
Power supply –48 V DC (range: –57 V to –40 V)

Grounding ≤5Ω
The ground resistance can be lower than 10 Ω in areas where the
number of thunderstorm days per year is less than 20.

Operating –20 ˚C to +50 ˚C


temperature
Operating 5% –95%
humidity
– Typical configuration: 1 x PM + 1 x SA + 1 x BPL + 1 x CC + 1 x FAM

© ZTE Corporation. All rights reserved


Capacity Specifications

Board Configuration Site Type Capacity Number of


Users in
CC Board BPL Board
RRC_Connect
Type Type
ed state
CC16B BPL1/BPN0 3 x 20 MHz cells (2T2R/2T4R) DL/UL: 450 Mbps/225 Mbps 3600
6 x 20 MHz cells (2T2R/2T4R) DL/UL: 600 Mbps/300 Mbps 3600
3 x 20 MHz cells (4T4R) DL/UL: 600 Mbps/300 Mbps 3600
2xBPL1/BPN0 9 x 20 MHz cells (2T2R/2T4R) DL/UL: 900 Mbps/600 Mbps 7200
12 x 20 MHz cells (2T2R/2T4R) DL/UL: 900 Mbps/600 Mbps 7200
3xBPL1/BPN0 18 x 20 MHz cells (2T2R/2T4R) DL/UL: 900 Mbps/900 Mbps 10800
BPL1A/BPN0A 3 x 20 MHz cells (2T2R/2T4R) DL/UL: 450 Mbps/225 Mbps 3600
CCE1 BPL1/BPN0 3 x 20 MHz cells (2T2R/2T4R) DL/UL: 450 Mbps/225 Mbps 3600
6 x 20 MHz cells (2T2R/2T4R) DL/UL: 600 Mbps/300 Mbps 3600
3 x 20 MHz cells (4T4R) DL/UL: 600 Mbps/300 Mbps 3600
2xBPL1/BPN0 9 x 20 MHz cells (2T2R/2T4R) DL/UL: 1200 Mbps/600 Mbps 7200
12 x 20 MHz cells (2T2R/2T4R) DL/UL: 1200 Mbps/600 Mbps 7200
3xBPL1/BPN0 18 x 20 MHz cells (2T2R/2T4R) DL/UL: 1800 Mbps/900 Mbps 10800
3xBPN2 36 x 20 MHz cells (2T2R/2T4R) DL/UL: 3600 Mbps/1800 Mbps 10800

© ZTE Corporation. All rights reserved


Power Consumption Specifications (Typical
Power Consumption at Normal Temperature)

Item Specification
3 cells/1 BPL1 120 W
6 cells/1 BPN0 90 W
24 carrier frequencies + 3 carrier 125 W
sectors (128 CEs) + 6 cells/ 1BPN2
12 carrier frequencies + 6 carrier 125 W
sectors (256 CEs) + 6 cells/ 1BPN2

Item Specification
Power consumption (typical 80 W
configuration at normal temperature)

– Typical configuration: 1 x PM + 1 x SA + 1 x BPN0 + 1 x CC16B + 1 x FAM

© ZTE Corporation. All rights reserved


ZXSDR B8200 TL200 Boards Overview
Name Slot Configuration Principle
CC 1–2 Two CCs are required for the active/standby configuration.

BPL1/BPL1A/BP 3–8 The baseband processing boards are configured in accordance with the required
N0/BPN0A/BN processing capability.
P2
SA 13
PM 14–15 • Two PMs are required when more than one baseband processing boards are
configured.

• Two PMs are required when two power supplies are operating in active/standby
mode.
FAM 16
FS 3–4 Optional. The FS board is required for the multi-mode configuration.

SE 5 Optional. One SE is required for the configuration of two RS232/RS485 interfaces


and 16 dry contacts, and a 0.5U blank panel is also required in the same slot.

UES Optional. The UES boards are configured in accordance with the actual Ethernet
requirement.
• Supporting the SyncE function: slot 2 and slot 5

• Not supporting the SyncE function: slot 1 to slot 8


UCI 3–8 Optional. The UCI boards are configured in accordance with the clock
configuration.

© ZTE Corporation. All rights reserved


ZXSDR B8200 Hardware and Interfaces

No. Interface Module Description


Cascading, debugging or local maintenance interface, GE/FE self-
1 DEBUG/CAS-/LMT CC
adaptive electrical interface
2 ETH0 CC S1/X2 interface, GE/FE self-adaptive electrical interface
3 TX/RX CC S1/X2 interface, GE/FE optical interface
4 USB CC Data updating
5 REF CC External GPS antenna interface
6 EXT CC External communication interface to connect external receiver
7 SA Interface SA/SE RS485/232 interface, 6+2 dry contact interfaces
8 -48V/-48VRTN PM Input power of –48 V
9 MON PM Debugging interface, RS232 interface
Three 2.4576G/4.9152G OBRI/ Ir optical interfaces, used for connecting
10 TX0 /RX0–TX2/RX2 BPL
RRU

© ZTE Corporation. All rights reserved


CC: Control and Clock Board

Interface (CC16B) Description


ETH0 Used as an S1/X2 Ethernet interface.
It is a GE/FE adaptive electrical interface.
DEBUG/CAS/LMT Used as an Ethernet interface for cascading, debugging, and
local maintenance.
It is a GE/FE adaptive electrical interface.
TX/RX Used as an S1/X2 Ethernet optical interface.
It is a GE/FE optical interface, and cannot be used at the same
time when the ETH0 interface is used.
The 1.25 Gbps optical module must be used.
EXT HDMI interface.
It provides one 1PPS+TOD input and one output, and outputs
testing clock signals.
REF External GPS antenna interface.
USB Serial interface for data update.

© ZTE Corporation. All rights reserved


CC: Control and Clock Board

Interface (CCE1) Description

ETH0 Used as an S1/X2 Ethernet interface.


It is a GE/FE adaptive electrical interface.

ETH1 Used as an Ethernet interface for cascading.


It is a GE/FE adaptive electrical interface.

DEBUG/LMT Used as an Ethernet interface for debugging and local maintenance.


It is a GE/FE adaptive electrical interface.

TX ETH2 RX Used as an S1/X2 optical interface.


It is a 1000/10000 Mbps adaptive optical interface.

TX ETH3 RX Used as an S1/X2 optical interface.


It is a 1000/10000 Mbps adaptive optical interface.

EXT HDMI interface.


It provides one 1PPS+TOD input and one output, and outputs testing clock
signals.

REF External GPS antenna interface.

USB Serial interface for data update.

© ZTE Corporation. All rights reserved


CC Module Indicator—1
Name Color Meaning Description
RUN Green Operating state • Off: The power supply is not operating properly.
indicator
• On: The board is loading the software version.

• Flashing slowly (0.3 s on, 0.3 s off): The board is operating properly.

• Flashing quickly (70 ms on, 70 ms off): The external communication of the


board is not normal.
ALM Red Alarm indicator • Off: There is no hardware fault.

• On: There is a hardware alarm reported.


MS Green Base station state • Active/standby state indication
indicator On: The board is in active state.
Off: The board is in standby state.
• USB state commissioning indication
Flashing slowly seven times (0.3 s on and 0.3 s off, 4.2 seconds in total): A
UKEY is inserted.
Off: The USB check is not passed.
Flashing quickly (70 ms on, 70 ms off): The USB commissioning is being
implemented.
Flashing slowly (0.3 s on, 0.3 s off): The USB commissioning is completed.
• System self-test state indication
Flashing quickly (70 ms on, 70 ms off): The system is performing self-test.
Flashing slowly (0.3 s on, 0.3 s off): The system self-test is completed.

© ZTE Corporation. All rights reserved


CC Module Indicator—2
Name Color Meaning Description
REF Green Reference clock • On: The reference clock source is not operating properly.
source
operating state • Off: The reference clock source is not configured.
indicator
• Flashing slowly (0.3 s on, 0.3 s off): The reference clock source is
operating properly.
ETH0 Green External • On: The Ethernet cable is connected properly.
Ethernet
interface • Flashing: Data is being transmitted or received.
(ABIS/IUB) state
indicator • Off: The Ethernet cable is not connected.
ETH1 Green Debug/LMT/CA • On: The Ethernet cable is connected properly.
S state indicator
• Flashing: Data is being transceived.

• Off: The Ethernet cable is not connected.


E0S-E3S Green E1 indicator

HS - - Reserved
Ethernet Green - • Left indicator
interface On: The interface is connected successfully.
indicator Off: The interface is not connected.
• Right indicator
Flashing: Data is being transceived.
Off: Data is not being transceived.

© ZTE Corporation. All rights reserved


CC: Control and Clock Module

 Button

Button Name Description


M/S Indicates the active/standby switch.
RST Indicates the reset switch.

© ZTE Corporation. All rights reserved


FS: Fabric Switch Module

FS Board Type Supported Wireless System CPRI Interface Rate


(Gbps)
FS5 GSM/UMTS/LTE (single-mode 1.2288/2.4576/
or multi-mode) 3.072/6.144
CR0 LTE (single-mode if there is a 1.2288/2.4576/
cloud radio requirement) 3.072/6.144/ 9.8304
FS5 Panel

CR0 Panel

© ZTE Corporation. All rights reserved


FS Module Indicator
Name Color Meaning Description
RUN Green Operating state • Off: The power supply is not operating properly.
indicator
• On: The board is loading the software version.

• Flashing slowly (0.3 s on, 0.3 s off): The board is operating properly.

• Flashing quickly (70 ms on, 70 ms off): The external communication of the board is
not normal.
ALM Red Alarm indicator • On: There is a hardware alarm reported.

• Off: There is no hardware fault.


CST Green Optical interface Reserved
state indicator
SCS Green Board clock state • On: Fsync is abnormal.
indicator
• Flashing slowly (0.3 s on, 0.3 s off): The clock is operating properly.

• Off: The 50CHIP clock is not operating properly.


FLS Green Forward • On: The TDM channel state is not normal.
baseband link
frame lock • Flashing slowly (0.3 s on, 0.3 s off): The TDM channel state is normal.
indicator
• Off: The TDM channel is not configured.
RLS Green Optical interface • Flashing according to time (the indicator flashes in an 18-second cycle, it
backward link sequentially indicates the backward baseband link frame lock state of the six optical
frame lock interfaces every three seconds):
indicator Flashing once ~ six times : The backward link of the 0th~5th optical interface is normal.
• Off: The optical link is not configured.
HS - - Reserved

© ZTE Corporation. All rights reserved


Performance Indexes for LTE BPL Boards
Index Type BPL1A BPL1 BPN0A BPN0 BPN2
Number of 3 pairs 3 pairs 6 pairs 6 pairs 6 pairs
CPRI optical
interfaces
Number of 3600 3600 3600 3600 7200
users
connected to
the RRC
Number of 3 6 3 6 12
cells (20 MHz,
2T2R/2T4R)
Number of N/A 3 N/A 3 6
cells (20 MHz,
4T4R)
Data DL 450 DL 600 DL 450 DL 600 Mbps/ DL 1200
throughput Mbps/UL 225 Mbps/ UL Mbps/ UL UL 300 Mbps Mbps/ UL
Mbps 300 Mbps 225 Mbps 600 Mbps

© ZTE Corporation. All rights reserved


BPL Panel and Interfaces
BPL1/BPL1A Panel

BPN0/BPN0A Panel

Notes:
BPN0A has the same panel as BPN0, but only TX0 RX0 to TX2 RX2 CPRI optical interfaces
are available on BPN0A.
BPN2 Panel

Board Interface Description


BPL1/BPL1A/ TX0 RX0 to TX2 Three pairs of CPRI optical interfaces/electrical
BPN0A RX2 interfaces, used to connect the BBU to RSU/RRUs.
BPN0/BPN2 TX0/RX0 to Six pairs of CPRI optical interfaces/electrical
TX5/RX5 interfaces, used to connect the BBU to RSU/RRUs.

© ZTE Corporation. All rights reserved


Performance Indexes for LTE Baseband
Processing Boards
Index Type BPL1A BPL1 BPN0A BPN0 BPN2

Number of 3 pairs 3 pairs 6 pairs 6 pairs 6 pairs


CPRI optical
interfaces
Number of 3600 3600 3600 3600 7200
users
connected
to the RRC
Number of 3 6 3 6 12
cells (20
MHz,
2T2R/2T4R)
Number of N/A 3 N/A 3 6
cells (20
MHz, 4T4R)
Data DL 450 DL 600 DL 450 DL 600 DL 1200
throughput Mbps/UL Mbps/ UL Mbps/ UL Mbps/ UL Mbps/ UL
225 Mbps 300 Mbps 225 Mbps 300 Mbps 600 Mbps

© ZTE Corporation. All rights reserved


BPL Indicators
Name Color Meaning Description
RUN Green Operating • On: The board is loading the software version.
state
indicator • Off: The power supply is not operating properly.

• Flashing slowly (0.3 s on, 0.3 s off): The board is operating properly.

• Flashing quickly (70 ms on, 70 ms off): The external communication of the board is not
normal.
ALM Red Hardware • On: The hardware is faulty.
fault
indicator • Off: There is no hardware fault.

OF0– Green Optical • On: The optical interface link is not operating properly.
OF5 interface
link state • Flashing slowly (0.3 s on, 0.3 s off): The optical interface is communicating properly.
indicator
• Off: The optical module is not in position or the optical module does not receive any
optical signal.
CST - - Reserved
HS - - Reserved
BLS - - Reserved
BSA - - Reserved
LNK - - Reserved

© ZTE Corporation. All rights reserved


SA: Site Alarm Module

Interface Description

RS485/232 interface, 6+2 dry contact


interfaces
(six input lines, two 2-way interfaces)

© ZTE Corporation. All rights reserved


SA Module Indicator

Name Color Meaning Description


RUN Green Operating • Off: The power supply is not operating properly.
state
indicator • On: The board is loading the software version.

• Flashing slowly (0.3 s on, 0.3 s off): The board is


operating properly.

• Flashing quickly (70 ms on, 70 ms off): The external


communication of the board is not normal.
ALM Red Alarm • Off: There is no hardware fault.
indicator
• On: There is a hardware alarm reported.
HS - - Reserved

© ZTE Corporation. All rights reserved


PM: Power Module

PM3 PM4

Type Description
PM3 Supports 300 W power output and 10-channel power outputs.
PM4 As a high-power power board, PM4 supports 400 W power
output and 10-channel power outputs.

Interface Description

MON Debugging interface, RS232 interface

–48V/–48VRTN –48V input/–48V GND input

© ZTE Corporation. All rights reserved


PM Module Indicators

Name Color Meaning Description


RUN Green Operating • Off: The power supply is not operating properly.
state
indicator • On: The board is loading the software version.

• Flashing slowly (0.3 s on, 0.3 s off): The board is operating


properly.

• Flashing quickly (70 ms on, 70 ms off): The external


communication of the board is not normal.
ALM Red Alarm • Off: There is no hardware fault.
indicator
• On: There is a hardware alarm reported.
PWR Blue Power • Off: The 12 V power supply is not operating properly.
(PM3 supply
panel) state • On: The 12 V power supply is operating properly.
indicator
HS - - Reserved
(PM4
panel)

© ZTE Corporation. All rights reserved


FM: Fan Module

 Function:
 Provides the fan control
function and interface.
 Provides a temperature
sensor to detect
temperature of air intake.
 Displays the fan status.

© ZTE Corporation. All rights reserved


FM Module Indicators

Name Color Meaning Description


RUN Green Operatin • Off: The power supply is not operating
g state properly.
indicator
• Flashing slowly (0.3 s on, 0.3 s off): The
module is operating properly.
• Flashing quickly (70 ms on, 70 ms off):
The external environment is not
normal.
ALM Red Alarm • Off: There is no hardware fault.
indicator
• On: The fan is faulty.

© ZTE Corporation. All rights reserved


UES: Universal Ethernet Switch Board

 The UES board provides the Ethernet synchronization function, and can
operate as a layer-2 switch. When operating as an Ethernet switch, this
board converges the data of other BBUs on its physical site, meaning
that there are multiple BBUs on a single physical site.

Interface Description
X1–X2 Electrical interfaces, fixedly used as cascading interfaces.
X3/ULPINK Electrical interface, used as a cascading interface or an uplink interface.
UPLINK Electrical interface or optical interface, fixedly used as a cascading
interface.
X4/UPLINK Optical interface, used as a cascading interface or an uplink interface.

© ZTE Corporation. All rights reserved


UES Indicators
Name Color Meaning Description
RUN Green Operating • Off: The power supply is not operating properly.
state • On: The board is loading the software version.
indicator • Flashing slowly (0.3 s on, 0.3 s off): The board is operating properly.
• Flashing quickly (70 ms on, 70 ms off): The external communication of the board is
not normal.

ALM Red Alarm • Off: There is no hardware fault.


indicator • On: There is a hardware alarm reported.

SCS Green 1588 • On: The 1588 protocol is supported.


function • Off: The 1588 protocol is not supported (for the time being).
indicator
ETS Green Clock state • Flashing slowly (0.3 s on, 0.3 s off): The PLL is locked, and the synchronous Ethernet
indicator clock is operating properly.
• Off: Not defined. By default, the ETS indicator is not lit.
• On: The PLL loses lock and the synchronous Ethernet clock is not operating properly.
OP1 Green Optical- • On: The link is operating properly but has no data being transceived.
interface • Flashing: The optical communication is normal.
X4/UPLINK • Off: The link is interrupted.
link state
indicator
OP2 Green Optical- • On: The link is operating properly but has no data being transceived.
interface • Flashing: The optical communication is normal.
UPLINK link • Off: The link is interrupted.
state
indicator
HS - - Reserved

© ZTE Corporation. All rights reserved


UCI: Universal Clock Interface Module

 The Universal Clock Interface (UCI) board is a RGPS interface board. The
UCI board receives, converts, and transfers BBU clocks.

Interface Description

TX RX 125 Mbps optical interface. Used to connect to an external RGPS device to get input signals.

EXT HDMI interface. Used for providing one channel of 1PPS+TOD clock signals to the CC board in
the shelf.

REF Reserved.

DLINK0 HDMI interface. Used for providing two channels of output 1PPS+TOD clock signals to the CC
board in other shelves.

DLINK1 HDMI interface. Used for providing two channels of output 1PPS+TOD clock signals to the CC
board in other shelves.

© ZTE Corporation. All rights reserved


UCI Module Indicators

Name Color Meaning Description


RUN Green Operating • Off: The power supply is not operating properly.
state
indicator • On: The board is loading the software version.
• Flashing slowly (0.3 s on, 0.3 s off): The board is
operating properly.
• Flashing quickly (70 ms on, 70 ms off): The external
communication of the board is not normal.
ALM Red Alarm • Off: There is no hardware fault.
indicator
• On: There is a hardware alarm reported.
OPT - - Reserved
P&T - - Reserved
RMD - - Reserved
LINK - - Reserved
HS - - Reserved

© ZTE Corporation. All rights reserved


Typical Configuration

Item Configuration Description

CC 1 Control and clock board

BPL 1 Baseband processing for LTE

PM 1 Power module, -48V DC input

FA 1 Fan module

SA 1 Site alarm board

© ZTE Corporation. All rights reserved


DC Power Cable

 The DC power cable is used for connecting the ZXSDR B8200


TL200 to an external power distributed unit.

Name Signal Description End A End B

-48 V RTN Voltage: 0 VDC A1 Black conductor

-48 V Voltage: -48 VDC A2 Blue conductor

© ZTE Corporation. All rights reserved


PE Cable

 The PE cable is used for connecting the ZXSDR B8200 TL200 to


the grounding network, so as to provide protection and ensure
personal safety. The PE cable is a 16 mm2 yellow-green cable
with TNR terminals at both ends.

© ZTE Corporation. All rights reserved


S1/X2 Cable

 S1/X2 optical fiber

 OMC/S1/X2 Ethernet cable

© ZTE Corporation. All rights reserved


RF Cable

 The RF cable is used for connecting the ZXSDR B8200 TL200 to


the eRRU.

 End A is used for connecting the eRRU, and end B is used for
connecting the ZXSDR B8200 TL200.

© ZTE Corporation. All rights reserved


Dry Contact Cable

 The dry contact cable is used to connect the ZXSDR B8200 TL200
to an external monitoring device, and thus receive dry contact
data from the external device or send dry contact data to the
external device.
 External view of a dry contact cable

© ZTE Corporation. All rights reserved


GPS Jumper

 The SMA(M)-SMA(M) GPS antenna cable is used to connect the


power splitter.

GPS antenna cable

Structure of embedded GPS


lightning arrester

© ZTE Corporation. All rights reserved


SA Panel Cable

© ZTE Corporation. All rights reserved


Contents

 eNodeB Overview
 ZXSDR B8200 L200 Hardware Structure
 ZXSDR R8882 Hardware Structure
 ZXSDR eNodeB Maintenance
Position of the ZXSDR R8882 in the Radio
Network

© ZTE Corporation. All rights reserved


Product Specifications
Specifications Description
R8882 S9000 (C) Three optical ports; a maximum of 6 Gbps; GSM single mode; 900 MHz frequency band; 2 x 60 W
R8882 S1800 (C) Three optical ports; a maximum of 6 Gbps; GSM single mode, 1800 MHz frequency band; 2 x 60 W
R8882 S9000 (B) Two optical ports; a maximum of 3 Gbps; GSM single mode, UMTS single mode, or GSM/UMTS dual mode; 900
MHz frequency band; 2 x 60 W
R8882 S9000 (B6C) Two optical ports; a maximum of 3 Gbps; GSM single mode, 900 MHz frequency band; 35MHz bandwidth for
duplexer, 2 x 60 W
R8882 S8500 (B6B) Two optical ports; a maximum of 3 Gbps; CDMA/GSM single mode, GSM/UMTS dual mode, or CDMA/LTE dual
mode; 850 MHz frequency band; 2 x 60 W
Two optical ports; a maximum of 3 Gbps; CDMA/LTE dual mode; 850 MHz frequency band; 2 x 60 W
R8882 S8000 (B4A) Two optical ports; a maximum of 3 Gbps; LTE single mode ; DD frequency band; 2 x 40 W
R8882 S2600 (B4A) Two optical ports; a maximum of 3 Gbps; LTE single mode ; 2.6 Gbps frequency band; 2 x 30 W
Two optical ports; a maximum of 3 Gbps; LTE single mode ; 2.6 Gbps frequency band; 2 x 40 W, CEPT
R8882 S2600 (B6A) Two optical ports; a maximum of 3 Gbps; LTE single mode ; 2.6 Gbps frequency band; 2 Carrier, 2 x 60 W, CEPT
R8882 S2100 (B) Two optical ports; a maximum of 3 Gbps; UMTS single mode; 2T4R; 2100 MHz frequency band; 2 x 60 W
Two optical ports; a maximum of 3 Gbps; LTE single mode or UMTS/LTE dual-mode;2100 MHz frequency band;
LTE single mode 2 x 60 W, UMTS/LTE dual-mode 2x50 W
R8882 S1900 (B6B) Two optical ports; a maximum of 3 Gbps; CDMA/GSM single mode, GSM/UMTS dual mode, or CDMA/LTE dual
mode; 1900 MHz frequency band; 2 x 50 W
Two optical ports; a maximum of 3 Gbps; CDMA/LTE dual mode; 1900 MHz frequency band; 2 x 60 W
R8882 S1800 (B6B) Two optical ports; a maximum of 3 Gbps; GSM single mode, or GSM/LTE dual mode; 1800 MHz frequency band;
2 x 60 W
R8882 S1800 (B6C) Two optical ports; a maximum of 3 Gbps; 2T2R, GSM single mode; 1800 MHz frequency band; 2 x 60 W
R8882 S1700 (B6A) Two optical ports; a maximum of 3 Gbps; LTE single mode or UMTS/LTE dual mode; 1700 MHz frequency band;
LTE single mode 2 x 60 W, UMTS/LTE dual-mode 2x50 W
R8882 S8100 (B6B) Two optical ports; a maximum of 3 Gbps; LTE single mode ; 810 MHz frequency band; 2 x 60 W
R8882 S7200 (B6A) Two optical ports; a maximum of 3 Gbps; LTE single mode; 2T2R; 720 MHz frequency band; 2 x 60 W

© ZTE Corporation. All rights reserved


ZXSDR R8882 Hardware Overview
The ZXSDR R8882 and a Base Band R8882 2x40 W
Unit (BBU) form a complete
BTS/NodeB/eNodeB, implementing
radio transmission in the covered
area, controlling radio channels and
realizing the communication with the
Base Station Controller (BSC)/Radio
Network Controller (RNC)/Long Term
Evolution (LTE).

R8882 2x60 W

© ZTE Corporation. All rights reserved


Interfaces and Indicators (ZXSDR R8882 With
Two Optical Interfaces)

© ZTE Corporation. All rights reserved


Interfaces and Indicators (ZXSDR R8882 With
Two Optical Interfaces)
No. Silkscreen Interface Connector Type Compliant Protocol
1 PWR -48V DC power input 2-pin round plastic connector (male) -
interface
2 MON External monitoring interface 8-pin straight panel-mounted -
welded round socket (male)

3 AISG AISG interface 8-pin socket with a square base AISG

4 - PE interface 16 mm2 yellow/green round -


terminal
5 OPT1 Interface for connecting a LC optical connector (IEC 874) ZTE private protocol
BBU and an RRU, or
cascading RRUs
6 OPT2 Interface for connecting a LC optical connector (IEC 874) ZTE private protocol
BBU and an RRU, or
cascading RRUs
7 ANT4 TX1/ RX1 Antenna feeder interface DIN connector -
(Tx1/Rx1)
8 ANT3 RX3 Antenna feeder interface (Rx3) DIN connector -
(Optional)
9 ANT2 RX2 Antenna feeder interface (Rx2) DIN connector -
(Optional)
10 ANT1 TX0/ RX0 Antenna feeder interface DIN connector -
(Tx0/Rx0)
11 LMT Ethernet interface for 8P8C shielded angle PCB socket -
operation and maintenance with LED (left yellow, right green)

© ZTE Corporation. All rights reserved


Interfaces and Indicators (ZXSDR R8882 With
Two Optical Interfaces)

Two Optical Interfaces Three Optical Interfaces

© ZTE Corporation. All rights reserved


Indicator Description
Name Meaning Color Operation Mode
Flashing at 2 Hz: The system is operating properly.
Power-on
On and other blinking modes: The system is being started or is not operating
RUN status Green
properly.
indicator
Off: The system is not powered on.
Alarm On: There is an alarm reported.
ALM Red
indicator Off: There is no alarm reported.
Optical Flashing: Optical interface 1 is communicating properly.
interface 1
OPT1 Green On: Optical interface 1 is not communicating properly (with optical signals).
status
indicator Off: Optical interface 1 is not communicating properly (without optical signals).

Optical Flashing: Optical interface 2 is communicating properly.


interface 2
OPT2 Green On: Optical interface 2 is not communicating properly (with optical signals).
status
indicator Off: Optical interface 2 is not communicating properly (without optical signals).

Optical Flashing: Optical interface 3 is communicating properly.


interface 3
OPT3 Green On: Optical interface 3 is not communicating properly (with optical signals).
status
indicator Off: Optical interface 3 is not communicating properly (without optical signals).

Tx0 VSWR On: TX0 antenna VSWR alarm


VSWR
status Red
1 Off: normal TX0 antenna VSWR
indicator
Tx1 VSWR On TX1 antenna VSWR alarm
VSWR
status Red
2 Off: normal TX1 antenna VSWR
indicator
© ZTE Corporation. All rights reserved
Interfaces and Indicators (ZXSDR R8882 With
Three Optical Interfaces)

© ZTE Corporation. All rights reserved


Interfaces and Indicators (ZXSDR R8882 With
Three Optical Interfaces)
No. Silkscreen Interface Connector Type Compliant Protocol
1 PWR -48V DC power input interface 2-pin round plastic connector -
(male)
2 MON External monitoring interface 8-pin straight panel-mounted -
welded round socket (male)

3 AISG AISG interface 8-pin socket with a square base AISG


4 - PE interface 16 mm2 yellow/green round -
terminal
5 OPT1 Interface for connecting a BBU LC optical connector (IEC 874) ZTE private protocol
and an RRU, or cascading RRUs
6 OPT2 Interface for connecting a BBU LC optical connector (IEC 874) ZTE private protocol
and an RRU, or cascading RRUs
7 OPT3 Interface for cascading RRUs on LC optical connector (IEC 874) ZTE private protocol
the same branch
8 ANT4 TX1/ RX1 Antenna interface (Tx1/Rx1) DIN connector -
9 ANT3 RX3 Antenna interface (Rx3) DIN connector -
(Optional)
10 ANT2 RX2 Antenna interface (Rx2) DIN connector -
(Optional)
11 ANT1 TX0/ RX0 Antenna interface (Tx0/Rx0) DIN connector -
12 LMT Ethernet interface for operation 8P8C shielded angle PCB mount -
and maintenance socket with LED (left yellow, right
green)

© ZTE Corporation. All rights reserved


DC Power Cable

Name Definition Core Color


-48 V -48 V DC power Blue
-48 V GND -48 V DC ground Black

© ZTE Corporation. All rights reserved


Antenna Feeder Cable

© ZTE Corporation. All rights reserved


Fiber

Fiber Cable for Connecting an RRU to a


BBU

Fiber Cable for Cascading RRUs

© ZTE Corporation. All rights reserved


RRU Technical Specifications

Index Specification
Dimensions 480 mm x 320 mm x 150 mm
(H x W x D)
Weight 23 kg
Power Supply –48 V DC (–57 V DC to –37 V DC)
Grounding In practical applications, the grounding resistance must be less than
10 Ω.
Temperature -40℃ to +55℃
Humidity 10%–100%

© ZTE Corporation. All rights reserved


Power Consumption
Item Specifications
S44: 310 W(900 MHz) / 320 W(1800 MHz)
Average power consumption in GSM single mode S66: 295 W(900 MHz) / 305 W(1800 MHz)
S66: 355 W(850 MHz) / 440 W(1900 MHz)
S1: 140 W
S2: 165 W
S3: 185 W
S11: 210 W
Average power consumption in UMTS single mode
S22: 265 W
(900 MHz)
S33: 310 W
S1 MIMO: 210 W
S2 MIMO: 265 W
S3 MIMO: 315 W
S1: 130 W
S2: 150 W
S3: 180 W
S11: 200 W
Average power consumption in UMTS single mode
S22: 215 W
(2100 MHz)
S33: 265 W
S1 MIMO: 170 W
S2 MIMO: 215 W
S3 MIMO: 270 W
Average power consumption in CDMA single mode 310 W (850 MHz) / 320 W (1900 MHz)
Average power consumption in LTE single mode 330 W (1800 MHz)
Rated input voltage –48 V DC (–57 V DC to –37 V DC)

© ZTE Corporation. All rights reserved


Radio Performance
Item Specification
GSM single mode Maximum: 2 x 6 carriers
UMTS single mode Maximum: 2 x 4 carriers
CDMA single mode Maximum: 2 x 8 carriers
LTE single mode 1 carrier
2 x 4 GSM carriers + 2 x 1 UMTS carriers, or 2 x 2 GSM carriers +
GSM/UMTS dual mode
2 x 2 UMTS carriers
• G/L dual-mode 900 MHz: 8 GSM TRXs + LTE 10 MHz
GSM/LTE dual mode
• G/L dual-mode 1800 MHz: 8 GSM TRXs + LTE 20 MHz
CDMA/LTE dual mode 2 x 4 CDMA carriers + 2 x 1 LTE carriers
• U/L dual-mode 2100 MHz: 2x 2 UMTS carriers + LTE 20 MHz
UMTS/LTE dual mode
• U/L dual-mode 1700 MHz: 2x 2 UMTS carriers + LTE 20 MHz

© ZTE Corporation. All rights reserved


RF Specifications

Item Specification

• GSM: 850 MHz/900 MHz/1800 MHz/1900 MHz


Working • UMTS: 850 MHz/900 MHz/1900 MHz/2100 MHz
frequency band • CDMA: 850 MHz/1900 MHz
• LTE: 800 MHz/1800 MHz/2600 MHz/1700 MHz/720 MHz

• GSM (850 MHz/900 MHz/1800 MHz): 2 x 60 W(GMSK)/2 x 40 W(8PSK)


• GSM (1900 MHz): 2 x 60 W(GMSK)/2 x 32 W(8PSK)
Transmit power • UMTS: 2 x 60 W(900 MHz/2100 MHz/850 MHz),2 x 60 W(1900 MHz)
• LTE: 2 x 60 W(S1700)/2 x 60 W(S1800)/2 x 40 W(S8000)/2 x 30
W(S2600)/2 x 60 W(S7200)

• GSM: –113.5 dBm (850 MHz/900 MHz/1800 MHz)


• UMTS single antenna: –125.8 dBm
Static receiver • UMTS dual antennas: –128.5 dBm
sensitivity • CDMA: –115 dBm
• LTE single antenna: –106 dBm
• LTE dual antenna: –108.6 dBm

© ZTE Corporation. All rights reserved


Contents

 eNodeB Overview
 ZXSDR B8200 L200 Hardware Structure
 ZXSDR R8882 Hardware Structure
 ZXSDR eNodeB Maintenance
Operation And Maintenance

© ZTE Corporation. All rights reserved


Operation and Maintenance

Measuremen
t Task
Management

Performance QoS Task


KPI Management

Performance
Management

Performance
Performance
Data
Report
Management

Performance
Graphic
Analysis

© ZTE Corporation. All rights reserved


Operation and Maintenance

Monitor
equipment

Fault
managem
ent

Multiple
Faults
alarming
oriented
methods

© ZTE Corporation. All rights reserved


Operation and Maintenance

Configuration Management

• NE data configuration
• Data download/upload
• Data comparison
• Data output/input
• Data audit
• Dynamic data management
• Time synchronization

© ZTE Corporation. All rights reserved


Operation and Maintenance

Security
log

Log
managem
ent

System Operation
log log

© ZTE Corporation. All rights reserved


Operation and Maintenance

login
authentica
tion

Security operation
Specifies
manage authentica
the roles
ment tion

Ensures the
legitimacy
of the
operation

© ZTE Corporation. All rights reserved


Operation and Maintenance

RRU OAM
• The ZXSDR R8972 configures RRU in accordance
with configuration data, forwards RRU’s
management commands from the NetNumen
U31, and collects RRU’s alarm and performance
information.

SON Functions
• SON functions can help perform some network
planning, configuration, optimization, and
healing processes automatically, and lower OPEX
by reducing manual involvement in such tasks.

© ZTE Corporation. All rights reserved

You might also like