You are on page 1of 1

4. No.

of pumps 1W+1S

5. Margin considered 10 %

6. Design flow per pump 538.6 CM/H

HEAD

7. Line losses (including fittings, valves, etc.,) 8.4 mWC

8. Static head 5 mWC

9. Pressure required at the inlet of clarifier 20 mWC

10. Flow Element loss (1 No.) 2 mWC

11. Total head 35.4 mWC

12. Margin on head 5 %

13. Design head 37.2 mWC

RWT PUMP

14. Selected flow per pump 540 CM/H

15. Selected head 40 mWC

5 DMWT PUMP FOR SUGAR COGEN BOILER HEAD AND FLOW CALCULATIONS
S.
DESCRIPTION VALUE UNIT REMARKS
No
FLOW

1. Boiler capacity 210 TPH

2. Boiler blow down loss 6.30 CM/H 3.0% loss

3. Cycle loss 3.15 CM/H 1.5% loss

4. Total process losses 8.25 CM/H