2.

Lube oil cooler 70 CM/H

3. Boiler feed pump 10 CM/H

4. Sample coolers 10 CM/H

5. DPAHS water cooled surge hoppers 10 CM/H

6. Side stream filter 12 CM/H

7. Total Flow 160 CM/H Sum of (1) to (6)

8. No. of pumps 1W + 1S

9. Margin Considered 10 %

10. Design Flow per pump 176 CM/H

HEAD

11. Line losses (including fittings, valves, etc.,) 17 mWC

12. Alternator air cooler pressure drop 10 mWC

13. Static head above pump C/L to hot water inlet 6

14. Flow Element Loss 2

15. Total head 35 mWC 11+12+13+14

16. Margin on head 5 %

17. Design head 36.75 mWC

ACW PUMP (SLOP COGEN)

18. Selected flow per pump 180 CM/H

19. Selected head 40 mWC

4 RAW WATER TRANSFER PUMP HEAD AND FLOW CALCULATIONS


S.
DESCRIPTION VALUE UNIT REMARKS
No
FLOW

1. Flow requirement at the inlet of clarifier 480 CM/H

2. Clarifier reject 9.6 CM/H

3. Flow per pump 489.6 CM/H (1) + (2)