13 FEED WATER TRANSFER PUMP HEAD AND FLOW CALCULATIONS

S.
DESCRIPTION VALUE UNIT REMARKS
No
FLOW

1. Process condensate return 34 CM/H

2. SCAPH return 6 CM/H

3. DM water makeup (Process + Boiler) 9 CM/H

4. Total Flow 49 CM/H (1) + (2) + (3)

5. No. of pumps 1W+1S

6. Margin considered 10 %

7. Design flow per pump 53.9 CM/H

HEAD

8. Line losses (including fittings, valves, etc.,) 12 mWC

9. Static head 18 mWC

10. Deaerator safety valve set pressure 50 mWC

11. Nozzle losses 10 mWC

12. Flow Element & Control valve loss 2.5 mWC

13. Total head 92.5 mWC

14. Margin on head 5 %

15. Design head 97.125 mWC

FEED WATER TRANSFER PUMP

16. Selected flow per pump 55 CMH

17. Selected head 100 mWC