Contacts Solenoid Cat. No.
Conduit Connector§
General
Actuator 1/2 inch NPT
Type Safety Auxiliary Contacts Voltage Type M20 Adaptor 12-Pin M23 8-Pin Micro (M12)♣
— 440G-T27121 ⎯ 440G-T27233 440G-T2NBBPH-1R
GD2
24V AC/DC
Standard
440G-T27251 440G-T27169 440G-T27234 ⎯
1-
AC/DC
— 440G-T27123 ⎯ ⎯ ⎯
2-Opto-electronics
Power to 2 N.C. 1 N.O.
1 N.O. 110V GD2
Lock
AC/DC Standard
440G-T27257 440G-T27178 ⎯ ⎯
3-Interlock
Release 440G-T27261 440G-T27184 ⎯ ⎯
Switches
AC/DC Standard
Fully Flex 440G-T27262 440G-T27186 ⎯ ⎯
230V
AC/DC
— 440G-T27136 ⎯ ⎯ ⎯
Operator
Interface
— 440G-T21BNPM-2B 440G-T21BNPT-2B 440G-T21BNPL-2B 440G-T2NBNPH-2B
TLS-3 GD2
Power to 24V AC/DC GD2
Standard
440G-T21BGPM-2B 440G-T21BGPT-2B 440G-T21BGPL-2B ⎯
Release
2 N.C. 1 N.O. 2 N.C.
with — 440G-T21BNPM-5B 440G-T21BNPT-5B ⎯ ⎯
Escape 110V
AC/DC GD2
Release
Standard
440G-T21BGPM-5B 440G-T21BGPT-5B ⎯ ⎯
To monitor independently the safety contact(s) and the solenoid feedback (TLS 1, 2 and 3):
Logic
Monitoring of safety contact(s) and the solenoid feedback (in series) is available, when jumpers are in place:
AND
WARNING: • For the TLS1 and TLS2: by using pins 4 and 6 on the 12-pin, M23 receptacle or Pink and Yellow wires on the
12-wire cordset (889M-F12AH-1)
• For the TLS3: by using pins 4 and 6 and pins 7 and 8 on the 12-pin, M23 receptacle or Pink and Yellow and
Power
Specifications
Safety Ratings
EN954-1, ISO13849-1, IEC/EN60204-1,
General
contacts. The TLS-GD2 head has two entry slots and it can be
(TLS-1 & -2) 2 N.O. (1 solenoid
rotated to provide four actuator entry points. A blanking plug is
Auxiliary Contacts monitoring)
provided to seat the unused slot. (TLS-3 1 N.O.)
The guard may only be opened when a signal is applied to the TLS- Thermal CurrentIlth 10 A
GD2's internal solenoid which releases the lock mechanism. This Rated Insulation Voltage (Ui) 500V
signal can be via CU1 electronic timer relays or CU2 stopped
motion detectors. Therefore the TLS-GD2 is ideal for machines Switching Current @ Voltage, Min. 5 mA @ 5V DC
which do not stop immediately or where premature interruption of Utilization Category
the machine could cause damage to tooling and components or A600/AC-15 (Ue) 600V 500V 240V 120V
cause an additional hazard. (le) 1.2 A 1.4 A 3.0 A 6.0 A
The TLS-GD2 is available in three types. The TLS-1 GD2 and TLS-3 DC-13 (Ue) 24V
GD2 incorporate a power-to-release function. Two manual release
3-Interlock
(le) 2 A
Switches
Approximate Dimensions
Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes.
126 (4.96)
General
9 (0.35)
39 (1.54)
14
33 (1.3)
27 (1.06)
25.5 (1)
22 (0.87)
(0.55)
3 (0.12)
5 (0.2)
21 17 6.5
(0.83) (0.67) 5 (0.2) 6.5 (0.26)
5.5 (0.22)
(0.26) M5
17
1-
(0.67)
57 (2.24)
21
(0.83)
86 (3.39)
73 (2.87)
2 x M5
2-Opto-electronics
14.5 (0.57)
4 (0.16)
31.5 (1.24)
3 (0.12)
6.5 (0.26)
52.5 (2.07)
60.5 (2.38)
67.5 (2.66)
17.0
(0.66)
14.5
(0.57)
31.4 (1.23)
3.0 (0.11) 52.0 (2.04)
60.0 (2.36)
Operator
Interface
67.0 (2.63)
43.0 (1.69)
21.0 (0.82)
17.25 (0.67)
This detail in key
23.5 (0.92) release only
125.0 (4.92)
6.0 (0.23)
104.0 (4.09) max.
20.5 (0.80)
14.0 (0.55)
9.0 (0.35) 5.0 (0.19)
3.25 (0.12)
5.5 (0.21)
65.25 (2.56)
Without Handle 9.75 (0.38)
75.0 (2.95) 39.0 (1.53)
Dia.
40.0 (1.57)
Dia.