D500 STANDARD SECTIONS TO STEEL 21 4" FLANGE BETWEEN 4" TO 47 8" 31 2" MIN.

21 4" FLANGE BETWEEN 4" TO 47 8" 31 2" MIN. BEARING FOR 4" SHOE (TYP.)
NOTE: 23 4" FLANGE BETWEEN 5" TO 57 8" 21 2" MIN. BEARING FOR 3" SHOE (TYP.)
1) WHEN MULTIPLE FLANGE ANGLE (F.H.) CONNECTION OPTIONS ARE SPECIFIED, THE FLANGE BETWEEN 6" TO 73 8"
4"
CHOSEN ONE MUST BE IN ACCORDANCE WITH THE PROJECT CONSULTING ENGINEER.
2 - 1 2" BOLTS ASTM A307 FLANGE BETWEEN 71 2" TO 87 8"
5"

. .
WELDED WIRE MESH 9 11 1
16" x 16" SLOTS @ 4 2" c/c * (HAMBRO SHOE)

TOP OF BEARING
CONCRETE SLAB 9 1 6" FLANGE BETWEEN 9" TO 97 8" 3
16" 11 2"
REMOVABLE 16" Ø HOLES @ 4 2" c/c * (SUPPORT) U.N.O.

T+1 4"
POUR STOP 7
ROLLBAR 8" FLANGE BETWEEN 10" TO 11 8"

SLAB
FLANGE ANGLE

. . . . .

(T)
(TYPE F.H.) 9" FLANGE OF 12" AND MORE
REMOVABLE PLYWOOD FORMING

JOIST DEPTH
TOP OF BEARING

NOMINAL
SLAB

(D)
(T)

T+1 4"
JOIST DEPTH
NOMINAL

(D)
CEILING EXTENSION

T+1 4" = SLAB THICKNESS + SHOE THICKNESS


CEILING EXTENSION TYP.
PERPENDICULAR TO A STEEL BEAM
T+1 4" = SLAB THICKNESS + SHOE THICKNESS 31 2" MIN. BEARING FOR 4" SHOE (TYP.)
( ) BOLTED JOISTS ON STEEL BEAM 21 2" MIN. BEARING FOR 3" SHOE (TYP.)
* *
* WHEN DEEP SHOE, THE c/c OF HOLE IS DIFFERENT, CONSULT THE APPROPRIATE DETAILS ON PLAN

. 3
16" 11 2"

SLAB
(T)
31 2" MIN. BEARING FOR 4" SHOE (TYP.)

WIDE FLANGE 2 - 1 2" BOLTS ASTM A307

JOIST DEPTH
TOP OF BEARING

NOMINAL
21 2"

. .
BEAM 9 11 1
16" x 16" SLOTS @ 4 2" c/c * (HAMBRO SHOE)

(D)
T+1 4"
9 1
16 " Ø HOLES @ 4 2 " c/c * (SUPPORT) U.N.O.
HAMBRO JOIST

SLAB
(T)
CEILING EXTENSION

JOIST DEPTH
TOP OF BEARING

NOMINAL
1
4" T+ 4" = SLAB THICKNESS + SHOE THICKNESS

(D)
T+1 4"
31 2" MIN. BEARING FOR 4" SHOE (TYP.)
PERPENDICULAR TO A STEEL BEAM
31 2" MIN. BEARING FOR 4" SHOE (TYP.)
1
2 2" MIN. BEARING FOR 3" SHOE (TYP.)
21 2" MIN. BEARING FOR 3" SHOE (TYP.) CEILING EXTENSION
TOP OF BEARING

HILTI STEEL DECK FASTENERS :

TOP OF BEARING
BRACING PLATE -HSN24 FOR 1 8"< t< 3 8"
T+1 4"

SELF TAPPING

. . . . . . . .
-EPN19 FOR t > 1 4" OR OR

T+1 4"
FASTENERS @ 12" c/c 3
4" Ø 24"
3
11 2" 3
11 2" t=MINIMUM THICKNESS OF

.
16" 16"

.
THE SUPPORTING STEEL
T+1 4" = SLAB THICKNESS + SHOE THICKNESS
SLAB

SLAB
(T)

(T)
( ) BOLTED JOISTS ON STEEL COLUMN

SLAB
(T)
* *
JOIST DEPTH

JOIST DEPTH
TOP OF BEARING
NOMINAL

NOMINAL
* WHEN DEEP SHOE, THE c/c OF HOLE IS DIFFERENT, CONSULT THE APPROPRIATE DETAILS ON PLAN

JOIST DEPTH
(D)

(D)
2" FLANGE HANGER

NOMINAL
SEE SPECIAL
T+1 4"

(D)
(TYPE F.H.) NOTE

CEILING EXTENSION TYP. CEILING EXTENSION


PLATE T+1 4" = SLAB THICKNESS + SHOE THICKNESS

T+1 4" = SLAB THICKNESS + SHOE THICKNESS T+1 4" = SLAB THICKNESS + SHOE THICKNESS PARALLEL TO A STEEL BEAM
PERPENDICULAR TO A STEEL BEAM PERPENDICULAR TO A STEEL BEAM WITH BRACING SPECIAL NOTE: IF THE FLANGE THICKNESS IS MORE THAN 11 16" INSTALL THE
FLANGE HANGER AT 1 2" TO THE FACE OF FLANGE