8 7 6 5 4 3 2 1

#12 x 1" SS SCREW


EXTRUDED CAP -USED FOR INSTALLATION GUTTER
CANOPY WIDTH & PAN 1/4-20 x 1-1/2" SS SCREW
USED FOR CANOPY OF CANOPY DECKING
(SEE NOTES)
FRAMING CONNECTIONS
GUTTER -3 ON EVERY SIDE OF BEAM
BEAM CONNECTION BRACKET
BEAM
BRACKET
GUTTER
1/4-20 x 1-1/2" SS SCREW F
F USED FOR CANOPY
FRAMING CONNECTIONS
BEAM EXTRUDED -3 ON EVERY SIDE OF BEAM
LINEAL BEAM BRACKET CONNECTION
B
A

SUPPORT COLUMN
SUPPORT COLUMN

BEAM LINEAL BEAM


EXTRUDED
CAP & PAN COLUMN
BRACKET 4" BRACKET
WELDED
COLUMN CORNER SET
BRACKET DETAIL A DETAIL A FRONT VIEW
SCALE 1 : 3 SCALE 1 : 3
ALUMINUM RIVET GUTTER E
E
CANOPY HEIGHT -10 PER CORNER SET,
(SEE NOTES) 6 PER OUTSIDE,
4 PER INSIDE
COLUMN LINEAL BEAM
#12 x 1" SS SCREW
-USED FOR INSTALLATION
COLUMN OF CANOPY DECKING

1/4-20 x 1-1/2" SS SCREW


USED FOR CANOPY
FRAMING CONNECTIONS BEAM

WELDED WELDED
D COLUMN COLUMN D
BRACKET BRACKET

SUPPORT COLUMN
COLUMN
FULLY
ALUMINUM DEFLECTOR PLATE WELDED COLUMN COLUMN
RIVET DEFLECTOR PLATE
-SEAL TO INTERIOR CONNECTION -SEAL TO INTERIOR
OF COLUMN OF COLUMN
DETAIL B ALUMINUM

SECTION VIEW OF CANOPY


SCALE 1 : 7 RIVET
6"
CONCRETE SLAB
(BY OTHERS)
CONCRETE SLAB
(BY OTHERS)
3
24" 4"
C
C 9 INCH #5 REBAR

CONCRETE FOOTING
- FOOTING SIZE AS CONCRETE FOOTING STYROFOAM BLOCKOUT
REQUIRED FOR BEARING - FOOTING SIZE AS -REMOVED AND FILLED WITH
UPLIFT AND MOMENT REQUIRED FOR BEARING CONCRETE DURING CANOPY
(BY OTHERS) UPLIFT AND MOMENT INSTALLATION
(BY OTHERS)

STYROFOAM BLOCKOUT 9 INCH #5 REBAR


DETAIL C
SCALE 1 : 8 -REMOVED AND FILLED WITH DETAIL C FRONT VIEW
CONCRETE DURING CANOPY SCALE 1 : 8
INSTALLATION

B
B

SPECIFICATIONS
Section 107300 - Aluminum Walkway Covers

1.01 General Description of Work:


A. Work in this section shall include design and fabrication of pre-engineered aluminum canopies.
B. Canopies are to be fabricated and installed according to approved shop drawings.

1.02 Design Criteria: JOB NAME:


A. International Building Code 2015
B. ASCE 7-10
C. Aluminum Design Manual 2015
COVERED
D. Local governing codes and standards for site location WALKWAY
CANOPIES
1.03 Materials:
A. All materials shall be extruded from aluminum unless indicated otherwise on the drawing.
A NOTES:
B. Material sizes shall meet or exceed the design criteria on 1.02 • DC = DRAINING COLUMN (IF APPLICABLE) A

1.04 Finishes: • CANOPY WIDTH RECOMMENDED NOT TO TITLE:

EXCEED 13'-0"
ARCHITECTUAL
ISOMETRIC VIEW
A. Factory applied baked enamel to comply with AAMA 2603
B. Color selected from manufacturers standard colors • COLUMN HEIGHT RECOMMENDED NOT TO
EXCEED 12'-0" OR WIDTH OF CANOPY, WHICH

OF CANOPY
1.05 Manufacturers:
A. Mitchell Metals, LLC -www.mitchellmetals.net - 770-431-7300
EVER IS LOWER
REVISION # :
B. Dittmer - www.dittdeck.com - 407-699-1755 • ALL FASTENERS TO BE 300 SERIES STAINLESS STEEL
C. See Specifications 2.1-C for conditions of equivalent systems by other manufacturers. OR ALUMINUM STAMP DATE: 8/16/2017 SHEET 1 OF 1