Title :  Crystallizer feed tank datasheet
Continental Gold Buritica Mine Water 
Project : 
Treatment Project
Customer :  Continental Gold Inc 4 4‐Jan‐18 Fourth Issue ASK SG SG
Location :  Antioquia Buritica, Colombia 3 6‐Jul‐17 Third Issue ASK SG SG
                                                 Job #  : P‐30066 2 19‐Apr‐17 Second Issue ASK SG SG
 Document# :  P‐30066‐SP‐BE‐CrystallizerFeedTank‐C 1 31‐Mar‐17 First Issue ASK SG SG
Issue# Date Description Prepared Checked Approved
Revision History
Issue# Comment Remark

1 First Issue

2 Second Issue, Issued For Procurement

3 Third Issue Vendor Drawing Included

4 Fourth Issue Final Vendor Drawing Included

10

11

12

13

CERTIFIED
14
Continental Gold Buritica Mine Water 
PROJECT:
Treatment Project
CUSTOMER: Continental Gold Inc 4 4‐Jan‐18 Fourth Issue ASK SG SG
LOCATION: Antioquia Buritica, Colombia 3 6‐Jul‐17 Third Issue ASK SG SG
JOB: P‐30066 2 19‐Apr‐17 Second Issue ASK SG SG
DOC: P‐30066‐SP‐BE‐CrystallizerFeedTank‐C 1 31‐Mar‐17 First Issue ASK SG SG
Issue Date Details By Checked Approved

Tag: 6100‐TK‐180

P & ID Ref:  P‐30066‐DW‐AE‐ICD001P5‐H Crystallizer Feed Tank

For AIC Internal use‐
Quantity 1 Sales Order No:  30066
Design Code ASME RTP‐1 Sales Item No: 540
Manufacturer Precision Engineering SAP Matl. No: XICDFRPTK01
Phase Number 777
Tank Bottom Flat Bottom (See sketch on Next page)
Top Head Dome Top
Process Fluid Recovery RO Reject Water
Specific Gravity 1.00
Design Temperature Range Minimum 14°C; Maximum 43.33°C
Operating Temperature Range Minimum 18°C; Maximum 24°C
Design Pressure Atmospheric + Static Head of Water
Operating Pressure Atmospheric + Static Head of Water
Material FRP
Resin Corrosion Liner : Swancor 901‐3 Clear;  Structural :Swancor 901‐3 Grey  (Note‐4,5,6)
Cure System MEKP ‐ Cobalt
Veil C Glass
Inner Surface shall be a reinforced resin rich lamination. The combined thickness of Inner surface and Interior 
Corrosion Resistant Barrier
lamination shall not be less than 0.10 inch.
Surface Hardness Barcol Hardness is 35
Tensile Strength  satisfactory for 93 Deg C (200 Deg F) Continuous  
Heat Resistance
Tensile Strength  satisfactory for 99 Deg C (210 Deg F) Transient 
Abrasion resistance Taber Test;  55 mg lost per 1,000 cycles 
Live Loads Per P‐30066‐RA‐BE‐NONMETALLICTANKS‐C
Wind Load Per P‐30066‐RA‐BE‐NONMETALLICTANKS‐C
Seismic Zone or Parameters  Per P‐30066‐RA‐BE‐NONMETALLICTANKS‐C
Snow Loads Not Applicable
Tank Diameter 1.2192m (4ft)
Tank Straight Shell 2.0574m (6.75ft)
Capacity (Working) 1.5 m3
Nozzles:
Inlet Nozzle N1 2", ANSI Class 150, FF, FRP Plate Gusseted with 6" Projection(Note‐8). (on Side)
Overflow Nozzle (N2) 4", ANSI Class 150, FF, FRP Plate Gusseted with 6" Projection(Note‐8). (on Side)
Drain Nozzle ( N3 ) 2", ANSI Class 150, FF, FRP Plate Gusseted with 6" Projection(Note‐8). (on Side)
Outlet Nozzle (N4) 3", ANSI Class 150, FF, FRP Plate Gusseted with 6" Projection(Note‐8). (on Side)
LIT Nozzle (N5) 2", ANSI Class 300, FF, FRP Plate Gusseted with 6" Projection(Note‐8). (on Side)
Vent, Goose Neck w/ Bird Screen/w Bird 
4", ANSI Class 150, FF, FRP Plate Gusseted with 6" Projection(Note‐8). (On Top)
Screen (N6)
Recycle Inlet Nozzle N7 2", ANSI Class 150, FF, FRP Plate Gusseted with 6" Projection(Note‐8). (on Side)
Spare (N8) 2", ANSI Class 150, FF, FRP Plate Gusseted with 6" Projection(Note‐8). W/ Blind Flange (on Side)
Manway (M1) 24", ANSI Class 150, FF, FRP Plate Gusseted with 6" Projection(Note‐8). W/ Blind Flange, Davit (on Side)
Continental Gold Buritica Mine Water 
PROJECT:
Treatment Project
CUSTOMER: Continental Gold Inc 4 4‐Jan‐18 Fourth Issue ASK SG SG
LOCATION: Antioquia Buritica, Colombia 3 6‐Jul‐17 Third Issue ASK SG SG
JOB: P‐30066 2 19‐Apr‐17 Second Issue ASK SG SG
DOC: P‐30066‐SP‐BE‐CrystallizerFeedTank‐C 1 31‐Mar‐17 First Issue ASK SG SG
Issue Date Details By Checked Approved
Baffles NA
Tank Support Tie Downs Lug support (Qty to be decided by Vendor)
Pipe Support Clips Required  
Installation Location Outdoor
Color Manufactures Standard (Note‐7)
Stairway & Platform NA
Ladder    NA
Lifting Lugs By Manufacturer
Hold Down Lugs By Manufacturer
Hardware A193 Gr B7/ ZP Studs w/ A194 Gr. 2H/ZP Nut and Washers
Gaskets EPDM/ Mfg. Std. compatible for Process fluid
Insulation NA
Name plate Required  

Notes:
1) Vendor to comply with requirements given in the datasheet and Requisition attachments P‐30066‐RA‐BE‐NONMETALLICTANKS‐C. Any deviations to be immediately 
informed to Aquatech.
2) '***' Marked data to be furnished by vendor with quote.
3) Refer sketch on Next Page. Nozzle locations shown are indicative. For Construction and Site Installation refer Vendor drawing
4) Water Chemistry(Concentration is indicated in ppm as Ion):
Recover RO Reject Water:‐Calcium=171.28mg/l;Magnesium=69.30mg/l;Sulfate=34,327.78mg/l;Silica total=0mg/l;Nitrate=32.70mg/l as N;Ammonia=0mg/l as N; 
Chloride=29,181.08mg/l; Sodium=35,206.26mg/l; Potassium=96.75mg/l; TDS=99,586.54mg/l;Hardness=7,555 mg/L as Ca CO3 ;Barium=0.00mg/l; 
Strontium=0mg/l;Fluoride=28.11mg/l;Bromide=0mg/l; pH=8.29
5) Vendor to ensure the Resin & resin structural material used is compatible for the given fluid, temperature and pressure conditions. 
6) Resin shall not have an HDT(Heat Distortion Temperature) less than 85°C (185 °F).
7) External surface of the tank to have UV Inhibitors for improved weather resistance. 
8) For All Nozzles bolt holes to straddle the principal centerlines. Gusset shall extend from the flange OD to the Tank wall.
9)  Tank drain nozzle to be as low as possible on shell. Nozzle should be able to support a load of 25LB at the end of the nozzle.
10) Vendor to furnish number of Anchors, bolt circle and size bolt required.
11)  Vendor to support the down comer(if any) adequately to prevent it from movement/vibration. 
12) Deleted. Nozzle Loads:‐  All nozzle shall to be capable of withstanding the load of  800N.
13) Vendor to provide the following documents:
      a) GA drawing for the Tank (Within 2 weeks of PO Placement)
      b) Instruction/Installation Manual

      c)The Tank vendor design drawing and documentation shall show complete design data including the following as a minimum: 
Overall tank dimensions, Elevation and plan view, Orientation, Center of Gravity, MOC of tank, Wall thicknesses, Laminate sequences of all FRP Layups, Tank capacity, Tank 
weight(Empty & Operating), Name plate Details, Testing and Inspection data, Tank restraint and hold down details,  Specific Gravity of contents, Design Temperature and 
pressure, reference codes and standards, Seismic, Wind and Snow load requirements and applicable tolerances as a minimum. 
DESIGN DATA NOZZLE SCHEDULE TH17521-7 D-17521-7 2

N6 N2

N3

N1 N5

303 NANTUCKET BLVD. SCARBOROUGH, ONTARIO ALL NOZZLE PROJECTION IS FROM INSIDE OF TANK

SHOP ORDER TH17521-7 DATE MFD. 2017


M1 N4 N7
CUSTOMER

AQUATECH
PURCHASE ORDER EQUIP. NO.
400002174 CRYSTALLIZER FEED TANK 6100-TK-180 BLIND FLANGES & COVERS
DESCRIPTION 4'-0" x 6'-9" STRAIGHT SIDE TANK
VENT DETAIL
WORKG. PRESS. ATMOSPHERIC WORKG. TEMP. AMBIENT

MATERIAL VINYL ESTER


N6 N8

TANK NAMEPLATE FIG. 6 FIG. 5

ORIENTATION PLAN NOZZLE MARK NOZZLE TYPE


CRYSTALLIZER FEED TANK

CONSTRUCTION DETAILS LAMINATE SEQUENCE


DIMENSIONS IN INCHES 1-C GLASS + 2 MAT

QUALITY CONTROL

N O T E S: N6
CARBON STEEL

TANK REQUIREMENTS
STANDARD TANK HANDLING INSTRUCTIONS
LIFTING LUG DETAIL DETAIL OF SIDE MANWAY
INSIDE ATTACHMENT

54[2 1/8"]
REF
102[4"]

102[4"] N8 N7 N1
N2
76[3"]

50[2"]
ATTACHMENT

FRP HOLD DOWN TUBES:


29[1 1/8"]
102[4"]

USE A 6[1/4"]THK STARTER (W/ ROVING) &


OVERLAY ENTIRE TUBE & 102[4"] ATTACHMENT 22[7/8"]
W/ 9[3/8"]THK [6M+4R]

tCL
127[5"]
64[2 1/2"]

SLOT M1
tS
64[2 1/2"]

(1) COMMERCIAL WASHER & (1)


HEAVY HEX NUT.
N5
CRYSTALLIZER FEED TANK
MAT'RL = A193-B7 MINIMUM
TORQUE = 5 FT-LBS (MAX)
(BY OTHERS)

3/4"THK - C.S. BEARING PLATE


508[20"] (STUD LENGTH)

N3 N4
CERTIFIED
127[5"] 270[10 5/8"]

HOLD DOWN TUBE HEIGHT


254[10"]

BEARING PLATE FOR PRODUCTION


(BY PRECISIONEERING)
MIN.EMBEDMENT

BY:..........................................

DATE: ...................................
tS+tB = 1/2"
- THE TANK IS TO BE ANCHORED TO 4k PSI REINFORCED PAD.
- CHEMICAL EPOXY BONDED STYLE ANCHORS TO BE USED @ MINIMUM DO NOT SCALE THIS DRAWING
USE DIMENSIONS ONLY
PRESSURE IS TO BE PUT ONTO TANK, AS OUTLINED IN THE DESIGN
- TANK MUST BE ANCHORED TO CONCRETE PAD FOR ANY TEST
tB

TANK O.D. VARIES DUE TO MANUFACTURING TECHNIQUE. DRAWING DISTRIBUTION


DO NOT INSTALL ANCHOR BOLTS UNTIL TANK IS IN
POSITION TO ENSURE PROPER ANCHOR BOLT LOCATION.

ELEVATION
TUBE TYPE
KNUCKLE DETAIL
HOLD DOWN LUG DETAIL 400002174 TH17521-7 D-17521-7 2