Bore 

Log
PROJECT :  G+6=7 Storied Residential Building
CLIENT : Kazi Zahirul Islam and others
LOCATION : Pathshala College, Amtoli, Cumilla
BORE HOLE NO.: BH‐01
METHOD OF DRILLING Percussion

            NOTE:
DIA. OF BORING
THICKNESS
SAMPLE ID

TYPE OF
SAMPLE
DEPTH
DATE

LOG
(ft)

(ft) SOIL LAYER DESCRIPTION GRAPHICAL REPRESENTATION OF SPT N VALUE

SPT-N
0 10 20 30 40 50 60 70 80
0' 0
85
D‐1 5

DIST. SAMPLE: 
1
D‐2 10 1
22.5' Very soft elastic silt (MH)
D‐3 15 1
D‐4 20 1
D‐5 5' Very soft fat clay (CH) 25 1
D‐6 5' Very soft elastic silt (MH) 30 1
D‐7 5' Very soft lean clay (CL) 35 1
Boring Date: 15 ‐09 ‐2020

D‐8 40 4
10' Soft to stiff lean clay (CL)
DEPTH (ft)

D‐9 45 9
D‐10 50 10
4 in

D‐11 55 4
D‐12 60 13
D‐13 65 13
D‐14 70 25
Loose to very dense silty sand 
D‐15 50'
(SM)
75 29
D‐16 80 37
D‐17 85 46
D‐18 90 49
D‐19 95 73
D‐20 100' 100 74

As Per USCS Classification

Geotech & Structures


Level‐16 (B),  Rupayan Karim Tower, 80 VIP Road, Kakrail Dhaka‐
1000 Cell: +8801885973767‐66    Email: design@geostruc.com
Bore Log
PROJECT :  G+6=7 Storied Residential Building
CLIENT : Kazi Zahirul Islam and others
LOCATION : Pathshala College, Amtoli, Cumilla
BORE HOLE NO.: BH‐02
METHOD OF DRILLING Percussion

            NOTE:
DIA. OF BORING
THICKNESS
SAMPLE ID

TYPE OF
SAMPLE
DEPTH
DATE

LOG
(ft)

(ft) SOIL LAYER DESCRIPTION GRAPHICAL REPRESENTATION OF SPT N VALUE

SPT-N
0 10 20 30 40 50 60 70 80 90
0' 0
85
D‐1 5

DIST. SAMPLE: 
12.5' Very soft silt (ML) 1
D‐2 10 1
D‐3 15 1
D‐4 15' very soft elastic silt (MH) 20 1
D‐5 25 1
D‐6 5' Very soft lean clay (CL) 30 1
D‐7 5' Very stiff silt (ML) 35 1
Boring Date: 16 ‐09 ‐2020

D‐8 40 5
10' Very soft lean clay (CL)
DEPTH (ft)

D‐9 45 9
D‐10 5' Silt with sand (Non plastic) 50 12
4 in

D‐11 5' Sandy silt (Non plastic) 55 15


D‐12 5' Silt (Non plastic) 60 10
D‐13 65 32
D‐14 70 36
D‐15 75 38
D‐16 Demse to very dense silty sand  80 53
40'
D‐17 (SM) 85 60
D‐18 90 73
D‐19 95 65
D‐20 100' 100 80

As Per USCS Classification

Geotech & Structures


Level‐16 (B),  Rupayan Karim Tower, 80 VIP Road, Kakrail Dhaka‐
1000 Cell: +8801885973767‐66    Email: design@geostruc.com
Geotech & Structures
Level‐16 (B),  Rupayan Karim Tower, 80 VIP Road, Dhaka‐1000   
Cell: +8801885973767   Email: design@geostruc.com
ATTERBERG LIMITS
Project :  G+6=7 Storied Residential Building
Client : Kazi Zahirul Islam and others Bore Hole No. : 1
Location             : Pathshala College, Amtoli, Cumilla Sample No. : D‐02
Standard             :   ASTM D 4318‐00
Sample Depth : 10 ft
Soil Type             : Elastic Silt (MH)

Test Result

y = -4.115ln(x) + 73.331
65
Water Content (%)

60

55
10 Number of Blows (N) 100

Liquid Limit = 60
Plastic Limit = 35
Plasticity Index =  25
As Per USCS Classification the Soil is  Elastic Silt (MH)

Countersigned by : Test Performed by :

Engr. Md. Humayun Kabir Engr. Wali Khan


Senior Design Engineer and Authorized Person Design Engineer
Geotech & Structures Geotech & Structures
Geotech & Structures
Level‐16 (B),  Rupayan Karim Tower, 80 VIP Road, Dhaka‐1000   
Cell: +8801885973767   Email: design@geostruc.com
ATTERBERG LIMITS
Project :  G+6=7 Storied Residential Building
Client : Kazi Zahirul Islam and others Bore Hole No. : 1
Location             : Pathshala College, Amtoli, Cumilla Sample No. : D‐04
Standard             :   ASTM D 4318‐00
Sample Depth : 20 ft
Soil Type             : Elastic Silt (MH)

Test Result

y = -46.8ln(x) + 422.99
300
295
290
285
Water Content (%)

280
275
270
265
260
255
250
10 Number of Blows (N) 100

Liquid Limit = 272
Plastic Limit = 182
Plasticity Index =  90
As Per USCS Classification the Soil is  Elastic Silt (MH)

Countersigned by : Test Performed by :

Engr. Md. Humayun Kabir Engr. Wali Khan


Senior Design Engineer and Authorized Person Design Engineer
Geotech & Structures Geotech & Structures
Geotech & Structures
Level‐16 (B),  Rupayan Karim Tower, 80 VIP Road, Dhaka‐1000   
Cell: +8801885973767   Email: design@geostruc.com
ATTERBERG LIMITS
Project :  G+6=7 Storied Residential Building
Client : Kazi Zahirul Islam and others Bore Hole No. : 1
Location             : Pathshala College, Amtoli, Cumilla Sample No. : D‐05
Standard             :   ASTM D 4318‐00
Sample Depth : 25 ft
Soil Type             : Fat Clay (CH)

Test Result

y = -2.37ln(x) + 58.862
55
Water Content (%)

50
10 Number of Blows (N) 100

Liquid Limit = 51
Plastic Limit = 28
Plasticity Index =  23
As Per USCS Classification the Soil is  Fat Clay (CH)

Countersigned by : Test Performed by :

Engr. Md. Humayun Kabir Engr. Wali Khan


Senior Design Engineer and Authorized Person Design Engineer
Geotech & Structures Geotech & Structures
Geotech & Structures
Level‐16 (B),  Rupayan Karim Tower, 80 VIP Road, Dhaka‐1000   
Cell: +8801885973767   Email: design@geostruc.com
ATTERBERG LIMITS
Project :  G+6=7 Storied Residential Building
Client : Kazi Zahirul Islam and others Bore Hole No. : 1
Location             : Pathshala College, Amtoli, Cumilla Sample No. : D‐06
Standard             :   ASTM D 4318‐00
Sample Depth : 30 ft
Soil Type             : Elastic Silt (MH)

Test Result

y = -6.34ln(x) + 76.084
60
Water Content (%)

55

50
10 Number of Blows (N) 100

Liquid Limit = 56
Plastic Limit = 35
Plasticity Index =  21
As Per USCS Classification the Soil is  Elastic Silt (MH)

Countersigned by : Test Performed by :

Engr. Md. Humayun Kabir Engr. Wali Khan


Senior Design Engineer and Authorized Person Design Engineer
Geotech & Structures Geotech & Structures
Geotech & Structures
Level‐16 (B),  Rupayan Karim Tower, 80 VIP Road, Dhaka‐1000   
Cell: +8801885973767   Email: design@geostruc.com
ATTERBERG LIMITS
Project :  G+6=7 Storied Residential Building
Client : Kazi Zahirul Islam and others Bore Hole No. : 1
Location             : Pathshala College, Amtoli, Cumilla Sample No. : D‐07
Standard             :   ASTM D 4318‐00
Sample Depth : 35 ft
Soil Type             : Lean Clay (CL)

Test Result

y = -0.939ln(x) + 29.993
30
Water Content (%)

25
10 Number of Blows (N) 100

Liquid Limit = 27
Plastic Limit = 14
Plasticity Index =  13
As Per USCS Classification the Soil is  Lean Clay (CL)

Countersigned by : Test Performed by :

Engr. Md. Humayun Kabir Engr. Wali Khan


Senior Design Engineer and Authorized Person Design Engineer
Geotech & Structures Geotech & Structures
Geotech & Structures
Level‐16 (B),  Rupayan Karim Tower, 80 VIP Road, Dhaka‐1000   
Cell: +8801885973767   Email: design@geostruc.com
ATTERBERG LIMITS
Project :  G+6=7 Storied Residential Building
Client : Kazi Zahirul Islam and others Bore Hole No. : 1
Location             : Pathshala College, Amtoli, Cumilla Sample No. : D‐08
Standard             :   ASTM D 4318‐00
Sample Depth : 40 ft
Soil Type             : Lean Clay (CL)

Test Result

y = -7.001ln(x) + 51.549
35
Water Content (%)

30

25
10 Number of Blows (N) 100

Liquid Limit = 29
Plastic Limit = 21
Plasticity Index =  8
As Per USCS Classification the Soil is  Lean Clay (CL)

Countersigned by : Test Performed by :

Engr. Md. Humayun Kabir Engr. Wali Khan


Senior Design Engineer and Authorized Person Design Engineer
Geotech & Structures Geotech & Structures
Geotech & Structures
Level‐16 (B),  Rupayan Karim Tower, 80 VIP Road, Dhaka‐1000   
Cell: +8801885973767   Email: design@geostruc.com
ATTERBERG LIMITS
Project :  G+6=7 Storied Residential Building
Client : Kazi Zahirul Islam and others Bore Hole No. : 1
Location             : Pathshala College, Amtoli, Cumilla Sample No. : D‐09
Standard             :   ASTM D 4318‐00
Sample Depth : 45 ft
Soil Type             : Lean Clay (CL)

Test Result

y = -9.142ln(x) + 73.458
50

45
Water Content (%)

40

35
10 Number of Blows (N) 100

Liquid Limit = 44
Plastic Limit = 21
Plasticity Index =  23
As Per USCS Classification the Soil is  Lean Clay (CL)

Countersigned by : Test Performed by :

Engr. Md. Humayun Kabir Engr. Wali Khan


Senior Design Engineer and Authorized Person Design Engineer
Geotech & Structures Geotech & Structures
Geotech & Structures
Level‐16 (B),  Rupayan Karim Tower, 80 VIP Road, Dhaka‐1000   
Cell: +8801885973767   Email: design@geostruc.com
ATTERBERG LIMITS
Project :  G+6=7 Storied Residential Building
Client : Kazi Zahirul Islam and others Bore Hole No. : 2
Location             : Pathshala College, Amtoli, Cumilla Sample No. : D‐02
Standard             :   ASTM D 4318‐00
Sample Depth : 10 ft
Soil Type             : Silt (ML)

Test Result

y = -4.164ln(x) + 53.281
45
Water Content (%)

40

35
10 Number of Blows (N) 100

Liquid Limit = 40
Plastic Limit = 27
Plasticity Index =  13
As Per USCS Classification the Soil is  Silt (ML)

Countersigned by : Test Performed by :

Engr. Md. Humayun Kabir Engr. Wali Khan


Senior Design Engineer and Authorized Person Design Engineer
Geotech & Structures Geotech & Structures
Geotech & Structures
Level‐16 (B),  Rupayan Karim Tower, 80 VIP Road, Dhaka‐1000   
Cell: +8801885973767   Email: design@geostruc.com
ATTERBERG LIMITS
Project :  G+6=7 Storied Residential Building
Client : Kazi Zahirul Islam and others Bore Hole No. : 2
Location             : Pathshala College, Amtoli, Cumilla Sample No. : D‐03
Standard             :   ASTM D 4318‐00
Sample Depth : 15 ft
Soil Type             : Elastic Silt (MH)

Test Result

y = -25.35ln(x) + 206.89
130

125
Water Content (%)

120

115

110
10 Number of Blows (N) 100

Liquid Limit = 125
Plastic Limit = 77
Plasticity Index =  48
As Per USCS Classification the Soil is  Elastic Silt (MH)

Countersigned by : Test Performed by :

Engr. Md. Humayun Kabir Engr. Wali Khan


Senior Design Engineer and Authorized Person Design Engineer
Geotech & Structures Geotech & Structures
Geotech & Structures
Level‐16 (B),  Rupayan Karim Tower, 80 VIP Road, Dhaka‐1000   
Cell: +8801885973767   Email: design@geostruc.com
ATTERBERG LIMITS
Project :  G+6=7 Storied Residential Building
Client : Kazi Zahirul Islam and others Bore Hole No. : 2
Location             : Pathshala College, Amtoli, Cumilla Sample No. : D‐04
Standard             :   ASTM D 4318‐00
Sample Depth : 20 ft
Soil Type             : Elastic Silt (MH)

Test Result

y = -4.552ln(x) + 74.605
65
Water Content (%)

60

55
10 Number of Blows (N) 100

Liquid Limit = 60
Plastic Limit = 41
Plasticity Index =  19
As Per USCS Classification the Soil is  Elastic Silt (MH)

Countersigned by : Test Performed by :

Engr. Md. Humayun Kabir Engr. Wali Khan


Senior Design Engineer and Authorized Person Design Engineer
Geotech & Structures Geotech & Structures
Geotech & Structures
Level‐16 (B),  Rupayan Karim Tower, 80 VIP Road, Dhaka‐1000   
Cell: +8801885973767   Email: design@geostruc.com
ATTERBERG LIMITS
Project :  G+6=7 Storied Residential Building
Client : Kazi Zahirul Islam and others Bore Hole No. : 2
Location             : Pathshala College, Amtoli, Cumilla Sample No. : D‐05
Standard             :   ASTM D 4318‐00
Sample Depth : 25 ft
Soil Type             : Elastic Silt (MH)

Test Result

y = -4.268ln(x) + 63.433
55
Water Content (%)

50

45
10 Number of Blows (N) 100

Liquid Limit = 50
Plastic Limit = 32
Plasticity Index =  18
As Per USCS Classification the Soil is  Elastic Silt (MH)

Countersigned by : Test Performed by :

Engr. Md. Humayun Kabir Engr. Wali Khan


Senior Design Engineer and Authorized Person Design Engineer
Geotech & Structures Geotech & Structures
Geotech & Structures
Level‐16 (B),  Rupayan Karim Tower, 80 VIP Road, Dhaka‐1000   
Cell: +8801885973767   Email: design@geostruc.com
ATTERBERG LIMITS
Project :  G+6=7 Storied Residential Building
Client : Kazi Zahirul Islam and others Bore Hole No. : 2
Location             : Pathshala College, Amtoli, Cumilla Sample No. : D‐06
Standard             :   ASTM D 4318‐00
Sample Depth : 30 ft
Soil Type             : Lean Clay (CL)

Test Result

y = -5.522ln(x) + 48.769
35
Water Content (%)

30

25
10 Number of Blows (N) 100

Liquid Limit = 31
Plastic Limit = 20
Plasticity Index =  11
As Per USCS Classification the Soil is  Lean Clay (CL)

Countersigned by : Test Performed by :

Engr. Md. Humayun Kabir Engr. Wali Khan


Senior Design Engineer and Authorized Person Design Engineer
Geotech & Structures Geotech & Structures
Geotech & Structures
Level‐16 (B),  Rupayan Karim Tower, 80 VIP Road, Dhaka‐1000   
Cell: +8801885973767   Email: design@geostruc.com
ATTERBERG LIMITS
Project :  G+6=7 Storied Residential Building
Client : Kazi Zahirul Islam and others Bore Hole No. : 2
Location             : Pathshala College, Amtoli, Cumilla Sample No. : D‐07
Standard             :   ASTM D 4318‐00
Sample Depth : 35 ft
Soil Type             : Silt (ML)

Test Result

y = -3.539ln(x) + 41.305
35
Water Content (%)

30
10 Number of Blows (N) 100

Liquid Limit = 30
Plastic Limit = 23
Plasticity Index =  7
As Per USCS Classification the Soil is  Silt (ML)

Countersigned by : Test Performed by :

Engr. Md. Humayun Kabir Engr. Wali Khan


Senior Design Engineer and Authorized Person Design Engineer
Geotech & Structures Geotech & Structures
Geotech & Structures
Level‐16 (B),  Rupayan Karim Tower, 80 VIP Road, Dhaka‐1000   
Cell: +8801885973767   Email: design@geostruc.com
ATTERBERG LIMITS
Project :  G+6=7 Storied Residential Building
Client : Kazi Zahirul Islam and others Bore Hole No. : 2
Location             : Pathshala College, Amtoli, Cumilla Sample No. : D‐08
Standard             :   ASTM D 4318‐00
Sample Depth : 40 ft
Soil Type             : Lean Clay (CL)

Test Result

y = -16.62ln(x) + 95.613
50

45
Water Content (%)

40

35

30
10 Number of Blows (N) 100

Liquid Limit = 42
Plastic Limit = 19
Plasticity Index =  23
As Per USCS Classification the Soil is  Lean Clay (CL)

Countersigned by : Test Performed by :

Engr. Md. Humayun Kabir Engr. Wali Khan


Senior Design Engineer and Authorized Person Design Engineer
Geotech & Structures Geotech & Structures
Geotech & Structures
Level‐16 (B),  Rupayan Karim Tower, 80 VIP Road, Dhaka‐1000              
Cell: +8801885973767   Email: design@geostruc.com

GRAIN SIZE ANALYSIS (Sieve)
Project               :  G+6=7 Storied Residential Building
Client                : Kazi Zahirul Islam and others Bore Hole No. : 1
Location : Pathshala College, Amtoli, Cumilla Sample No. : D‐11
Standard ASTM D422‐63, D136‐05 & AASHTO T27 Sample Depth : 55 ft

TEST REPORT
Sieve Material Percent of Cumulative Percent Fineness
Size Retained Material Retained % Retained Finer Modulus
mm gm % % %
4.75 0.00 0 0 100
2.36 0.00 0 0 100
1.18 0.00 0 0 100 0.54
0.6 0.00 0 0 100
0.3 0.00 0 0 100
0.15 28.69 54 54 46
0.075 3.99 7 61 39
Pan 20.57 39.0
Total 53.25

Grain Size Distribution
100

90

80
Percent Finer (%)

70

60

50

40

30

20

10

0
0.01 0.1 1 10

Particle Size (mm)

Silt and Clay= 39 %
Sand= 61 %

Countersigned by : Test Performed by :

Engr. Md. Humayun Kabir Engr. Wali Khan


Senior Design Engineer and Authorized Person Design Engineer
Geotech & Structures Geotech & Structures
Geotech & Structures
Level‐16 (B),  Rupayan Karim Tower, 80 VIP Road, Dhaka‐1000              
Cell: +8801885973767   Email: design@geostruc.com

GRAIN SIZE ANALYSIS (Sieve)
Project               :  G+6=7 Storied Residential Building
Client                : Kazi Zahirul Islam and others Bore Hole No. : 1
Location : Pathshala College, Amtoli, Cumilla Sample No. : D‐12
Standard ASTM D422‐63, D136‐05 & AASHTO T27 Sample Depth : 60 ft

TEST REPORT
Sieve Material Percent of Cumulative Percent Fineness
Size Retained Material Retained % Retained Finer Modulus
mm gm % % %
4.75 0.00 0 0 100
2.36 0.00 0 0 100
1.18 0.00 0 0 100 0.46
0.6 0.00 0 0 100
0.3 0.00 0 0 100
0.15 20.46 46 46 54
0.075 5.69 13 59 41
Pan 18.79 42.0
Total 44.94

Grain Size Distribution
100

90

80
Percent Finer (%)

70

60

50

40

30

20

10

0
0.01 0.1 1 10

Particle Size (mm)

Silt and Clay= 42 %
Sand= 58 %

Countersigned by : Test Performed by :

Engr. Md. Humayun Kabir Engr. Wali Khan


Senior Design Engineer and Authorized Person Design Engineer
Geotech & Structures Geotech & Structures
Geotech & Structures
Level‐16 (B),  Rupayan Karim Tower, 80 VIP Road, Dhaka‐1000              
Cell: +8801885973767   Email: design@geostruc.com

GRAIN SIZE ANALYSIS (Sieve)
Project               :  G+6=7 Storied Residential Building
Client                : Kazi Zahirul Islam and others Bore Hole No. : 1
Location : Pathshala College, Amtoli, Cumilla Sample No. : D‐13
Standard ASTM D422‐63, D136‐05 & AASHTO T27 Sample Depth : 65 ft

TEST REPORT
Sieve Material Percent of Cumulative Percent Fineness
Size Retained Material Retained % Retained Finer Modulus
mm gm % % %
4.75 0.00 0 0 100
2.36 0.00 0 0 100
1.18 0.00 0 0 100 0.58
0.6 0.00 0 0 100
0.3 0.00 0 0 100
0.15 31.46 58 58 42
0.075 5.80 11 69 31
Pan 16.71 31.0
Total 53.97

Grain Size Distribution
100

90

80
Percent Finer (%)

70

60

50

40

30

20

10

0
0.01 0.1 1 10

Particle Size (mm)

Silt and Clay= 31 %
Sand= 69 %

Countersigned by : Test Performed by :

Engr. Md. Humayun Kabir Engr. Wali Khan


Senior Design Engineer and Authorized Person Design Engineer
Geotech & Structures Geotech & Structures
Geotech & Structures
Level‐16 (B),  Rupayan Karim Tower, 80 VIP Road, Dhaka‐1000              
Cell: +8801885973767   Email: design@geostruc.com

GRAIN SIZE ANALYSIS (Sieve)
Project               :  G+6=7 Storied Residential Building
Client                : Kazi Zahirul Islam and others Bore Hole No. : 1
Location : Pathshala College, Amtoli, Cumilla Sample No. : D‐14
Standard ASTM D422‐63, D136‐05 & AASHTO T27 Sample Depth : 70 ft

TEST REPORT
Sieve Material Percent of Cumulative Percent Fineness
Size Retained Material Retained % Retained Finer Modulus
mm gm % % %
4.75 0.00 0 0 100
2.36 0.00 0 0 100
1.18 0.00 0 0 100 0.42
0.6 0.00 0 0 100
0.3 0.00 0 0 100
0.15 27.46 42 42 58
0.075 11.44 17 59 41
Pan 26.56 41.0
Total 65.46

Grain Size Distribution
100

90

80
Percent Finer (%)

70

60

50

40

30

20

10

0
0.01 0.1 1 10

Particle Size (mm)

Silt and Clay= 41 %
Sand= 59 %

Countersigned by : Test Performed by :

Engr. Md. Humayun Kabir Engr. Wali Khan


Senior Design Engineer and Authorized Person Design Engineer
Geotech & Structures Geotech & Structures
Geotech & Structures
Level‐16 (B),  Rupayan Karim Tower, 80 VIP Road, Dhaka‐1000              
Cell: +8801885973767   Email: design@geostruc.com

GRAIN SIZE ANALYSIS (Sieve)
Project               :  G+6=7 Storied Residential Building
Client                : Kazi Zahirul Islam and others Bore Hole No. : 1
Location : Pathshala College, Amtoli, Cumilla Sample No. : D‐15
Standard ASTM D422‐63, D136‐05 & AASHTO T27 Sample Depth : 75 ft

TEST REPORT
Sieve Material Percent of Cumulative Percent Fineness
Size Retained Material Retained % Retained Finer Modulus
mm gm % % %
4.75 0.00 0 0 100
2.36 0.00 0 0 100
1.18 0.00 0 0 100 0.55
0.6 0.00 0 0 100
0.3 1.18 2 2 98
0.15 38.95 51 53 47
0.075 5.01 7 60 40
Pan 31.46 41.0
Total 76.60

Grain Size Distribution
100

90

80
Percent Finer (%)

70

60

50

40

30

20

10

0
0.01 0.1 1 10

Particle Size (mm)

Silt and Clay= 41 %
Sand= 59 %

Countersigned by : Test Performed by :

Engr. Md. Humayun Kabir Engr. Wali Khan


Senior Design Engineer and Authorized Person Design Engineer
Geotech & Structures Geotech & Structures
Geotech & Structures
Level‐16 (B),  Rupayan Karim Tower, 80 VIP Road, Dhaka‐1000              
Cell: +8801885973767   Email: design@geostruc.com

GRAIN SIZE ANALYSIS (Sieve)
Project               :  G+6=7 Storied Residential Building
Client                : Kazi Zahirul Islam and others Bore Hole No. : 1
Location : Pathshala College, Amtoli, Cumilla Sample No. : D‐16
Standard ASTM D422‐63, D136‐05 & AASHTO T27 Sample Depth : 80 ft

TEST REPORT
Sieve Material Percent of Cumulative Percent Fineness
Size Retained Material Retained % Retained Finer Modulus
mm gm % % %
4.75 0.00 0 0 100
2.36 0.00 0 0 100
1.18 0.00 0 0 100 0.76
0.6 0.00 0 0 100
0.3 6.88 10 10 90
0.15 40.18 56 66 34
0.075 4.26 6 72 28
Pan 20.46 29.0
Total 71.78

Grain Size Distribution
100

90

80
Percent Finer (%)

70

60

50

40

30

20

10

0
0.01 0.1 1 10

Particle Size (mm)

Silt and Clay= 29 %
Sand= 71 %

Countersigned by : Test Performed by :

Engr. Md. Humayun Kabir Engr. Wali Khan


Senior Design Engineer and Authorized Person Design Engineer
Geotech & Structures Geotech & Structures
Geotech & Structures
Level‐16 (B),  Rupayan Karim Tower, 80 VIP Road, Dhaka‐1000              
Cell: +8801885973767   Email: design@geostruc.com

GRAIN SIZE ANALYSIS (Sieve)
Project               :  G+6=7 Storied Residential Building
Client                : Kazi Zahirul Islam and others Bore Hole No. : 1
Location : Pathshala College, Amtoli, Cumilla Sample No. : D‐17
Standard ASTM D422‐63, D136‐05 & AASHTO T27 Sample Depth : 85 ft

TEST REPORT
Sieve Material Percent of Cumulative Percent Fineness
Size Retained Material Retained % Retained Finer Modulus
mm gm % % %
4.75 0.00 0 0 100
2.36 0.00 0 0 100
1.18 0.00 0 0 100 0.85
0.6 0.00 0 0 100
0.3 12.44 19 19 81
0.15 31.26 47 66 34
0.075 2.79 4 70 30
Pan 19.64 30.0
Total 66.13

Grain Size Distribution
100

90

80
Percent Finer (%)

70

60

50

40

30

20

10

0
0.01 0.1 1 10

Particle Size (mm)

Silt and Clay= 30 %
Sand= 70 %

Countersigned by : Test Performed by :

Engr. Md. Humayun Kabir Engr. Wali Khan


Senior Design Engineer and Authorized Person Design Engineer
Geotech & Structures Geotech & Structures
Geotech & Structures
Level‐16 (B),  Rupayan Karim Tower, 80 VIP Road, Dhaka‐1000              
Cell: +8801885973767   Email: design@geostruc.com

GRAIN SIZE ANALYSIS (Sieve)
Project               :  G+6=7 Storied Residential Building
Client                : Kazi Zahirul Islam and others Bore Hole No. : 1
Location : Pathshala College, Amtoli, Cumilla Sample No. : D‐18
Standard ASTM D422‐63, D136‐05 & AASHTO T27 Sample Depth : 90 ft

TEST REPORT
Sieve Material Percent of Cumulative Percent Fineness
Size Retained Material Retained % Retained Finer Modulus
mm gm % % %
4.75 0.00 0 0 100
2.36 0.00 0 0 100
1.18 0.00 0 0 100 0.91
0.6 0.00 0 0 100
0.3 16.80 23 23 77
0.15 33.53 45 68 32
0.075 3.26 4 72 28
Pan 20.94 28.0
Total 74.53

Grain Size Distribution
100

90

80
Percent Finer (%)

70

60

50

40

30

20

10

0
0.01 0.1 1 10

Particle Size (mm)

Silt and Clay= 28 %
Sand= 72 %

Countersigned by : Test Performed by :

Engr. Md. Humayun Kabir Engr. Wali Khan


Senior Design Engineer and Authorized Person Design Engineer
Geotech & Structures Geotech & Structures
Geotech & Structures
Level‐16 (B),  Rupayan Karim Tower, 80 VIP Road, Dhaka‐1000              
Cell: +8801885973767   Email: design@geostruc.com

GRAIN SIZE ANALYSIS (Sieve)
Project               :  G+6=7 Storied Residential Building
Client                : Kazi Zahirul Islam and others Bore Hole No. : 1
Location : Pathshala College, Amtoli, Cumilla Sample No. : D‐19
Standard ASTM D422‐63, D136‐05 & AASHTO T27 Sample Depth : 95 ft

TEST REPORT
Sieve Material Percent of Cumulative Percent Fineness
Size Retained Material Retained % Retained Finer Modulus
mm gm % % %
4.75 0.00 0 0 100
2.36 0.00 0 0 100
1.18 0.00 0 0 100 0.81
0.6 0.00 0 0 100
0.3 8.08 13 13 87
0.15 35.63 55 68 32
0.075 3.37 5 73 27
Pan 17.14 27.0
Total 64.22

Grain Size Distribution
100

90

80
Percent Finer (%)

70

60

50

40

30

20

10

0
0.01 0.1 1 10

Particle Size (mm)

Silt and Clay= 27 %
Sand= 73 %

Countersigned by : Test Performed by :

Engr. Md. Humayun Kabir Engr. Wali Khan


Senior Design Engineer and Authorized Person Design Engineer
Geotech & Structures Geotech & Structures
Geotech & Structures
Level‐16 (B),  Rupayan Karim Tower, 80 VIP Road, Dhaka‐1000              
Cell: +8801885973767   Email: design@geostruc.com

GRAIN SIZE ANALYSIS (Sieve)
Project               :  G+6=7 Storied Residential Building
Client                : Kazi Zahirul Islam and others Bore Hole No. : 1
Location : Pathshala College, Amtoli, Cumilla Sample No. : D‐20
Standard ASTM D422‐63, D136‐05 & AASHTO T27 Sample Depth : 100 ft

TEST REPORT
Sieve Material Percent of Cumulative Percent Fineness
Size Retained Material Retained % Retained Finer Modulus
mm gm % % %
4.75 0.00 0 0 100
2.36 0.00 0 0 100
1.18 0.00 0 0 100 0.79
0.6 0.00 0 0 100
0.3 5.08 10 10 90
0.15 29.31 59 69 31
0.075 3.26 7 76 24
Pan 11.62 24.0
Total 49.27

Grain Size Distribution
100

90

80
Percent Finer (%)

70

60

50

40

30

20

10

0
0.01 0.1 1 10

Particle Size (mm)

Silt and Clay= 24 %
Sand= 76 %

Countersigned by : Test Performed by :

Engr. Md. Humayun Kabir Engr. Wali Khan


Senior Design Engineer and Authorized Person Design Engineer
Geotech & Structures Geotech & Structures
Geotech & Structures
Level‐16 (B),  Rupayan Karim Tower, 80 VIP Road, Dhaka‐1000              
Cell: +8801885973767   Email: design@geostruc.com

GRAIN SIZE ANALYSIS (Sieve)
Project               :  G+6=7 Storied Residential Building
Client                : Kazi Zahirul Islam and others Bore Hole No. : 2
Location : Pathshala College, Amtoli, Cumilla Sample No. : D‐13
Standard ASTM D422‐63, D136‐05 & AASHTO T27 Sample Depth : 65 ft

TEST REPORT
Sieve Material Percent of Cumulative Percent Fineness
Size Retained Material Retained % Retained Finer Modulus
mm gm % % %
4.75 0.00 0 0 100
2.36 0.00 0 0 100
1.18 0.00 0 0 100 0.54
0.6 0.00 0 0 100
0.3 0.00 0 0 100
0.15 46.17 54 54 46
0.075 10.40 12 66 34
Pan 29.00 34.0
Total 85.57

Grain Size Distribution
100

90

80
Percent Finer (%)

70

60

50

40

30

20

10

0
0.01 0.1 1 10

Particle Size (mm)

Silt and Clay= 34 %
Sand= 66 %

Countersigned by : Test Performed by :

Engr. Md. Humayun Kabir Engr. Wali Khan


Senior Design Engineer and Authorized Person Design Engineer
Geotech & Structures Geotech & Structures
Geotech & Structures
Level‐16 (B),  Rupayan Karim Tower, 80 VIP Road, Dhaka‐1000              
Cell: +8801885973767   Email: design@geostruc.com

GRAIN SIZE ANALYSIS (Sieve)
Project               :  G+6=7 Storied Residential Building
Client                : Kazi Zahirul Islam and others Bore Hole No. : 2
Location : Pathshala College, Amtoli, Cumilla Sample No. : D‐14
Standard ASTM D422‐63, D136‐05 & AASHTO T27 Sample Depth : 70 ft

TEST REPORT
Sieve Material Percent of Cumulative Percent Fineness
Size Retained Material Retained % Retained Finer Modulus
mm gm % % %
4.75 0.00 0 0 100
2.36 0.00 0 0 100
1.18 0.00 0 0 100 0.46
0.6 0.00 0 0 100
0.3 0.08 0 0 100
0.15 32.13 46 46 54
0.075 8.24 12 58 42
Pan 29.28 42.0
Total 69.73

Grain Size Distribution
100

90

80
Percent Finer (%)

70

60

50

40

30

20

10

0
0.01 0.1 1 10

Particle Size (mm)

Silt and Clay= 42 %
Sand= 58 %

Countersigned by : Test Performed by :

Engr. Md. Humayun Kabir Engr. Wali Khan


Senior Design Engineer and Authorized Person Design Engineer
Geotech & Structures Geotech & Structures
Geotech & Structures
Level‐16 (B),  Rupayan Karim Tower, 80 VIP Road, Dhaka‐1000              
Cell: +8801885973767   Email: design@geostruc.com

GRAIN SIZE ANALYSIS (Sieve)
Project               :  G+6=7 Storied Residential Building
Client                : Kazi Zahirul Islam and others Bore Hole No. : 2
Location : Pathshala College, Amtoli, Cumilla Sample No. : D‐15
Standard ASTM D422‐63, D136‐05 & AASHTO T27 Sample Depth : 75 ft

TEST REPORT
Sieve Material Percent of Cumulative Percent Fineness
Size Retained Material Retained % Retained Finer Modulus
mm gm % % %
4.75 0.00 0 0 100
2.36 0.00 0 0 100
1.18 0.00 0 0 100 0.58
0.6 0.00 0 0 100
0.3 2.20 2 2 98
0.15 48.83 54 56 44
0.075 6.65 7 63 37
Pan 32.04 36.0
Total 89.72

Grain Size Distribution
100

90

80
Percent Finer (%)

70

60

50

40

30

20

10

0
0.01 0.1 1 10

Particle Size (mm)

Silt and Clay= 36 %
Sand= 64 %

Countersigned by : Test Performed by :

Engr. Md. Humayun Kabir Engr. Wali Khan


Senior Design Engineer and Authorized Person Design Engineer
Geotech & Structures Geotech & Structures
Geotech & Structures
Level‐16 (B),  Rupayan Karim Tower, 80 VIP Road, Dhaka‐1000              
Cell: +8801885973767   Email: design@geostruc.com

GRAIN SIZE ANALYSIS (Sieve)
Project               :  G+6=7 Storied Residential Building
Client                : Kazi Zahirul Islam and others Bore Hole No. : 2
Location : Pathshala College, Amtoli, Cumilla Sample No. : D‐16
Standard ASTM D422‐63, D136‐05 & AASHTO T27 Sample Depth : 80 ft

TEST REPORT
Sieve Material Percent of Cumulative Percent Fineness
Size Retained Material Retained % Retained Finer Modulus
mm gm % % %
4.75 0.00 0 0 100
2.36 0.00 0 0 100
1.18 0.00 0 0 100 0.75
0.6 0.00 0 0 100
0.3 7.14 8 8 92
0.15 55.56 59 67 33
0.075 5.64 6 73 27
Pan 26.08 28.0
Total 94.42

Grain Size Distribution
100

90

80
Percent Finer (%)

70

60

50

40

30

20

10

0
0.01 0.1 1 10

Particle Size (mm)

Silt and Clay= 28 %
Sand= 72 %

Countersigned by : Test Performed by :

Engr. Md. Humayun Kabir Engr. Wali Khan


Senior Design Engineer and Authorized Person Design Engineer
Geotech & Structures Geotech & Structures
Geotech & Structures
Level‐16 (B),  Rupayan Karim Tower, 80 VIP Road, Dhaka‐1000              
Cell: +8801885973767   Email: design@geostruc.com

GRAIN SIZE ANALYSIS (Sieve)
Project               :  G+6=7 Storied Residential Building
Client                : Kazi Zahirul Islam and others Bore Hole No. : 2
Location : Pathshala College, Amtoli, Cumilla Sample No. : D‐17
Standard ASTM D422‐63, D136‐05 & AASHTO T27 Sample Depth : 85 ft

TEST REPORT
Sieve Material Percent of Cumulative Percent Fineness
Size Retained Material Retained % Retained Finer Modulus
mm gm % % %
4.75 0.00 0 0 100
2.36 0.00 0 0 100
1.18 0.00 0 0 100 0.92
0.6 0.00 0 0 100
0.3 17.18 23 23 77
0.15 33.33 46 69 31
0.075 3.15 4 73 27
Pan 19.54 27.0
Total 73.20

Grain Size Distribution
100

90

80
Percent Finer (%)

70

60

50

40

30

20

10

0
0.01 0.1 1 10

Particle Size (mm)

Silt and Clay= 27 %
Sand= 73 %

Countersigned by : Test Performed by :

Engr. Md. Humayun Kabir Engr. Wali Khan


Senior Design Engineer and Authorized Person Design Engineer
Geotech & Structures Geotech & Structures
Geotech & Structures
Level‐16 (B),  Rupayan Karim Tower, 80 VIP Road, Dhaka‐1000              
Cell: +8801885973767   Email: design@geostruc.com

GRAIN SIZE ANALYSIS (Sieve)
Project               :  G+6=7 Storied Residential Building
Client                : Kazi Zahirul Islam and others Bore Hole No. : 2
Location : Pathshala College, Amtoli, Cumilla Sample No. : D‐18
Standard ASTM D422‐63, D136‐05 & AASHTO T27 Sample Depth : 90 ft

TEST REPORT
Sieve Material Percent of Cumulative Percent Fineness
Size Retained Material Retained % Retained Finer Modulus
mm gm % % %
4.75 0.00 0 0 100
2.36 0.00 0 0 100
1.18 0.00 0 0 100 0.82
0.6 0.00 0 0 100
0.3 5.08 10 10 90
0.15 31.69 62 72 28
0.075 3.18 6 78 22
Pan 11.20 22.0
Total 51.15

Grain Size Distribution
100

90

80
Percent Finer (%)

70

60

50

40

30

20

10

0
0.01 0.1 1 10

Particle Size (mm)

Silt and Clay= 22 %
Sand= 78 %

Countersigned by : Test Performed by :

Engr. Md. Humayun Kabir Engr. Wali Khan


Senior Design Engineer and Authorized Person Design Engineer
Geotech & Structures Geotech & Structures
Geotech & Structures
Level‐16 (B),  Rupayan Karim Tower, 80 VIP Road, Dhaka‐1000              
Cell: +8801885973767   Email: design@geostruc.com

GRAIN SIZE ANALYSIS (Sieve)
Project               :  G+6=7 Storied Residential Building
Client                : Kazi Zahirul Islam and others Bore Hole No. : 2
Location : Pathshala College, Amtoli, Cumilla Sample No. : D‐19
Standard ASTM D422‐63, D136‐05 & AASHTO T27 Sample Depth : 95 ft

TEST REPORT
Sieve Material Percent of Cumulative Percent Fineness
Size Retained Material Retained % Retained Finer Modulus
mm gm % % %
4.75 0.00 0 0 100
2.36 0.00 0 0 100
1.18 0.00 0 0 100 0.81
0.6 0.00 0 0 100
0.3 13.92 15 15 85
0.15 47.46 51 66 34
0.075 4.37 5 71 29
Pan 26.79 29.0
Total 92.54

Grain Size Distribution
100

90

80
Percent Finer (%)

70

60

50

40

30

20

10

0
0.01 0.1 1 10

Particle Size (mm)

Silt and Clay= 29 %
Sand= 71 %

Countersigned by : Test Performed by :

Engr. Md. Humayun Kabir Engr. Wali Khan


Senior Design Engineer and Authorized Person Design Engineer
Geotech & Structures Geotech & Structures
Geotech & Structures
Level‐16 (B),  Rupayan Karim Tower, 80 VIP Road, Dhaka‐1000              
Cell: +8801885973767   Email: design@geostruc.com

GRAIN SIZE ANALYSIS (Sieve)
Project               :  G+6=7 Storied Residential Building
Client                : Kazi Zahirul Islam and others Bore Hole No. : 2
Location : Pathshala College, Amtoli, Cumilla Sample No. : D‐20
Standard ASTM D422‐63, D136‐05 & AASHTO T27 Sample Depth : 100 ft

TEST REPORT
Sieve Material Percent of Cumulative Percent Fineness
Size Retained Material Retained % Retained Finer Modulus
mm gm % % %
4.75 0.00 0 0 100
2.36 0.00 0 0 100
1.18 0.00 0 0 100 0.89
0.6 0.00 0 0 100
0.3 17.11 17 17 83
0.15 56.67 55 72 28
0.075 3.11 3 75 25
Pan 26.80 26.0
Total 103.69

Grain Size Distribution
100

90

80
Percent Finer (%)

70

60

50

40

30

20

10

0
0.01 0.1 1 10

Particle Size (mm)

Silt and Clay= 26 %
Sand= 74 %

Countersigned by : Test Performed by :

Engr. Md. Humayun Kabir Engr. Wali Khan


Senior Design Engineer and Authorized Person Design Engineer
Geotech & Structures Geotech & Structures

You might also like