What is an isolated installation composed of?
An isolated installation is one that is capable of supplying the electric energy necessary to power previously determined consumptions,
independently of the existence of a power network or any other source of power generation.

The combination of wind and solar technologies guarantees a more stable and balanced generation throughout the day (day / night) and seasons
(summer / winter) during the 365 days of the year.

WIND TURBINE
Generates electricity from wind power, either during the day or at night. Its power varies relative to the needs of the installation.
Bornay produces windturbines with a power output of 600, 800, 1500, 3000 and 6000 W that covers all kind of needs.

SOLAR MODULES
Generates electricity using solar radiation: therefore, its use is limited to daylight hours.

The number of the solar modules and its power depends on the total energy required for the installation.

CONTROLLER
Controls the electricity generated by the wind turbine or the solar panels. It also controls the state of the battery bank. Prevents
the overcharge and discharge of the battery bank

BATTERY
Store the energy produced by the wind turbine and solar panels, making it available for later use. It is recommended to have
battery banks that last a minimum of three cays of autonomy.

INVERTER
The inverter transforms the energy stored in the form of continuous current in the batteries into alternating current for domestic
use. It can incorporate a charger to recharge the batteries if there is available an AC external source such as a generator set.
Furthermore, there are inverters that allow for a wide range of possibilities such as interaction with generator sets or with the
electrical grid, permitting much broader applications, for example, three-phase or parallel installations, Smart Grids, self-
consumption or network support.

2 / 11
(v2.0) is a free tool developed by www.bornay.com 2 / 11
Site of the installation.
At the site indicated the following resources are available:

T est
INST ALLAT ION

36,4738
LAT IT UDE

2,6252
LONGIT UDE

0m2
PLOT

0m2
BUILDING

-10º
MINIMUM
T EMPERAT URE

40º
MAXIMUM
T EMPERAT URE

Mo n th Win ds pe e d S o lar Radiatio n

January 3,96 m/s 4,12 kWh/m2

February 4,07 m/s 5,31 kWh/m2

March 4,03 m/s 6,47 kWh/m2

April 4,05 m/s 6,83 kWh/m2

May 3,48 m/s 7,20 kWh/m2

June 3,48 m/s 7,42 kWh/m2

July 3,65 m/s 7,49 kWh/m2

August 3,47 m/s 7,34 kWh/m2

September 3,33 m/s 6,86 kWh/m2

October 3,46 m/s 6,11 kWh/m2

November 3,90 m/s 4,50 kWh/m2

December 4,06 m/s 3,91 kWh/m2

These data were obtained from public databases available on different web pages.

The data constitute an estimate of production based on this information and cannot be used as a guarantee of production.

The only way to guarantee production is to obtain local registrations at the place of installation.

3 / 11
(v2.0) is a free tool developed by www.bornay.com 3 / 11
Your installations consumption
Co n s ume r P o we r Un its Ho ur s Co n s umptio n

Electronic equipment 1248 W 1 24,0 h 29952 Wh/day

Month Enero Febrero Marzo Abril Mayo Junio Julio Agosto Septiembre Octubre Noviembre Diciembre

GSM antennas 0W 1 24,0 h 0 Wh/day

Month Enero Febrero Marzo Abril Mayo Junio Julio Agosto Septiembre Octubre Noviembre Diciembre

Radio stations 0W 1 24,0 h 0 Wh/day

Month Enero Febrero Marzo Abril Mayo Junio Julio Agosto Septiembre Octubre Noviembre Diciembre

Refrigeration equipment 0W 1 6,0 h 0 Wh/day

Month Octubre

RF antenna 0W 1 24,0 h 0 Wh/day

Month Enero Febrero Marzo Abril Mayo Junio Julio Agosto Septiembre Octubre Noviembre Diciembre

The consumption data for the installation were furnished by the client and are used to determine the energy requirements of the installation, what
elements are needed to produce the power required, and what battery is necessary to guarantee the supply, as well as the other accessories
such as the inverter, charger and regulators.

If the data are not correct, the installation will not work as it is expected to.

Please review the data carefully to see that they correspond to the requirements of the installation, and if this is not the case, request the pertinent
modifications.

4 / 11
(v2.0) is a free tool developed by www.bornay.com 4 / 11
This is what you need in renewable energy.
With the consumption provided, we dimension the installation of renewable energies to supply the power required.

Wind Energy
Wind Turbine
Bornay Wind 25.3 + 5000 2 Wind T urbines
MODEL NOMINAL POWER UNIT S

Mo n th Win ds pe e d Win d pr o duc tio n

January 3,96 m/s 19,87 kWh/day

February 4,07 m/s 21,31 kWh/day

March 4,03 m/s 21,31 kWh/day

April 4,05 m/s 21,31 kWh/day

May 3,48 m/s 13,16 kWh/day

June 3,48 m/s 13,16 kWh/day

July 3,65 m/s 15,74 kWh/day

August 3,47 m/s 13,16 kWh/day

September 3,33 m/s 11,93 kWh/day

October 3,46 m/s 13,16 kWh/day

November 3,90 m/s 19,87 kWh/day

December 4,06 m/s 21,31 kWh/day

5 / 11
(v2.0) is a free tool developed by www.bornay.com 5 / 11
Solar Energy
Solar modules
SR-M660L 315 W 315 W 8 Panels
MODEL NOMINAL POWER UNIT S

Mo n th S o lar Radiatio n S o lar P r o duc tio n

January 4,12 kWh/m2 10,37 kWh/day

February 5,31 kWh/m2 13,37 kWh/day

March 6,47 kWh/m2 16,31 kWh/day

April 6,83 kWh/m2 17,21 kWh/day

May 7,20 kWh/m2 18,15 kWh/day

June 7,42 kWh/m2 18,69 kWh/day

July 7,49 kWh/m2 18,87 kWh/day

August 7,34 kWh/m2 18,50 kWh/day

September 6,86 kWh/m2 17,30 kWh/day

October 6,11 kWh/m2 15,40 kWh/day

November 4,50 kWh/m2 11,33 kWh/day

December 3,91 kWh/m2 9,86 kWh/day

6 / 11
(v2.0) is a free tool developed by www.bornay.com 6 / 11
Consumption Vs Production
Mo n th D aily n e e ds Win d pr o duc tio n S o lar P r o duc tio n To tal P r o duc tio n

January 29,95 kWh/day 19,87 kWh/day 10,37 kWh/day 30,25 kWh/day

February 29,95 kWh/day 21,31 kWh/day 13,37 kWh/day 34,68 kWh/day

March 29,95 kWh/day 21,31 kWh/day 16,31 kWh/day 37,62 kWh/day

April 29,95 kWh/day 21,31 kWh/day 17,21 kWh/day 38,52 kWh/day

May 29,95 kWh/day 13,16 kWh/day 18,15 kWh/day 31,31 kWh/day

June 29,95 kWh/day 13,16 kWh/day 18,69 kWh/day 31,85 kWh/day

July 29,95 kWh/day 15,74 kWh/day 18,87 kWh/day 34,61 kWh/day

August 29,95 kWh/day 13,16 kWh/day 18,50 kWh/day 31,66 kWh/day

September 29,95 kWh/day 11,93 kWh/day 17,30 kWh/day 29,22 kWh/day

October 29,95 kWh/day 13,16 kWh/day 15,40 kWh/day 28,56 kWh/day

November 29,95 kWh/day 19,87 kWh/day 11,33 kWh/day 31,21 kWh/day

December 29,95 kWh/day 21,31 kWh/day 9,86 kWh/day 31,17 kWh/day

En Fe Ma Ab Ma Ju Ju Ag Se Oc No Di

Photovoltaic Wind Consumption

7 / 11
(v2.0) is a free tool developed by www.bornay.com 7 / 11
Rest of the components
Solar Controller
MODEL BlueSolar MPPT 150/45
UNITS 1 Control

TYPE MPPT

Batteries
VOLTAGE 48 V
AUTONOMY 3 Days

BATTERY CAPACITY 2170 C10


BATTERY CAPACITY 2840 C100

UNITS 4

MODEL 15 PVV 2850

Inverter
INPUT VOLTAGE 48 V
OUTPUT VOLTAGE 230 V

FREQUENCY 50 Hz
MAXIMUM SIMULTANEOUS POWER 1248 W

INVERTERS POWER 2400 W


CHARGER Yes

THREE PHASES No
UNITS 1

MODEL Phoenix MultiPlus 48/3000/35-16

8 / 11
(v2.0) is a free tool developed by www.bornay.com 8 / 11
Installation diagram

8x 2x
SR-M660L 315 W Bornay Wind 25.3 +

1x
BlueSolar MPPT 150/45 1x
Phoenix MultiPlus 48/3000/35-
16

4x
15 PVV 2850

9 / 11
(v2.0) is a free tool developed by www.bornay.com 9 / 11
Needed materials
Un its D e s c r iptio n Mo de l Lin k

8 Solar module SR-M660L 315 W

8 Modules support Module supports

2 Wind Turbine Bornay Wind 25.3 +

2 Sels supported squared tower Wind Turbine Support

1 Inverter Phoenix MultiPlus 48/3000/35-16

1 Controller BlueSolar MPPT 150/45

4 Battery 15 PVV 2850

10 / 11
(v2.0) is a free tool developed by www.bornay.com 10 / 11
Legal Advise
The information contained in this document is not binding nor does it guarantee that the results are going to be those indicated.

The data used to determine consumption were provided by the user of the application. They should be as real as possible, and it should be taken
into account that any alteration to lesser or greater means an excess or lack of power.

The data used to determine the production of energy were taken from public databases available online and verified by qualified technical
personnel, though this does not imply a guarantee of production.

In order for data of this kind to be taken as a guarantee, they have to have been registered locally in the place of installation by specific equipment
and for a particular period of time.

B-planner is an online application of Bornay Aerogeneradores, SLU, designed to facilitate the installers’ task of dimensioning installations,
reserving the right to modify it without notice.

11 / 11
(v2.0) is a free tool developed by www.bornay.com 11 / 11

You might also like