Professional Documents
Culture Documents
212412
Manufactures According To
PS
Pakistan Standards
INTRODUCTION 01
APPROVED BY / ENLISTED WITH 02
QUALITY POLICY 03
PVC ENVIRONMENTAL ABOUT US 05
PVC INTRODUCTION 06
ADVANTAGES OF PVC 07
HANDLING & STORAGE
PVC 08
MARKING GENERAL 09
PROPERTIES INFO 10
FLUID PROPERTIES 47
WATER HAMMER 49
PRESSURE / TEMPERATURE 50
EARTH & WHEEL LOAD 51
JOINTING PROCEDURE 52
CHEMICAL RESISTANCE
DESIGN & 55
CONVERSION TABLE ENGINEERING 56
OTHER PRODUCTS DATA 57
INTRODUCTION
Kawsar Engineering Private Limited has established in 1994 as a manufacturer for water Hand Pumps.
Kawsar started its regular production of plastic Polyvinyl Chloride PVC Pressure and non-Pressure pipe
system for cold and potable water and other industrial uses from March 2004.After Achievement in PVC
Kawsar Now Started PPR- C, HDPE pipes & Fitting with Advance Technology. We aim to set standards in
every field we enter. Customer focus, quality and innovation are reflected in every aspect of our
business. Our strength lies in pre-empting customer expectations and product demands. KAWSAR today
is a hallmark of trust and reliability. This is why KAWSAR employs are highly skilled and experienced labor,
KAWSAR utilizes the most advanced technology on its production line and retains the modern
management system.
As a group, we have commitment to high ethical business values, quality of products, committed
deliveries and competitive pricing. These are the factor which has taken us to the path of success
achieving great heights and we are confident to achieve further heights in the times to come with the
new setup. Kawsar has highly qualified staff and has experienced staff about `12 year .
We believe that our strength lies in delighting our customers. That is why, providing quality products
backed by superior technical support services, is the KAWSAR promise to all our valued customers.
Besides its unique place in the Pakistan plastic and Hand Pumps industry, KAWSAR products are being
exported to various other countries and thus play an important role in economy of Pakistan. That's why
KAWSAR was awarded the BEST EXPORTER AWARDS TROPHY continuously from 2002-2012 from Prime
minister of Pakistan.
CERTIFICATIONS
In our quest to lead by example, our joint efforts have led KAWSAR to ISO 9001:2000 Certification and
accreditation for supreme product performance and quality by the Pakistan Standard Institute (PSI) and
Pakistan Engineering Council.
Certified Company
APPROVED BY
ENLISTED WITH
DACCAR Danish Committee for Aid to Afghan Refugee
SCA Swedish Committee for Afghanistan
IRC International Rescue Committee
UNDP United National Development Program
UNICEF United Nations Children Emergency Fund
for Pakistan and Afghanistan
ICRC International Committee of the Red Cross
QC Qatar Charity
QRC Qatar Red Crescent
SRSP Sarhad Rural Support Programme
QUALITY POLICY
Kawsar total quality control perceptive is taken as a principal while performing
the mission. Our main policy is to provide the present and future needs and
demands of our customers in the most economical way and on time. In all our
processes, we adopt in the principle of customer oriented understanding.
Aim for improvement full participation of our staff. In this process
management, our main goal is to continuously improve our production and to
respond the demands of our customers, personals and suppliers.
OUR MISSION
To increase the number of pleased and trusted customers in our
sector by satisfying them from our quality.
OUR VISION
To be committed to the mission of being the symbol of trust and contentment in the plastic and fittings market,
KAWSAR proceeds to this targets as being the leader in the domestic market. And being a under rental and
permanent supplier in the international market.
WHY KAWSAR?
Being one of the best firms in the country in manufacturing sector of PVC, PPRC, HDPE Pipes and Fittings, Kawsar
Gives at most of the importance to the Quality control and:
1. Uses the most appropriate material
2. Has the most advanced high technology
3. Has well qualified technical Staff and Experienced Labor
4. Produces Pipes in compliance with the International Standards.
5. Has Well equipped laboratory which is round the clock busy to control the
Quality at each stage of production
QUALITY CONTROL
LABORATORY TESTING
To ensure quality of pipes following tests are regularly conducted in our laboratory as per British, Pakistan
and American Standards.
JOINTING SYSTEM
Fire Resistance
• PVC piping systems are self- extinguishing and will
not support combustion. The ASTM E 84 test protocol is used
to determine the flame and smoke rating for various
materials.
Handling and Storage of PVC Pipe
Receiving Pipe
As pipe is received, it must always be thoroughly inch requires extra care as the added pipe weight can
inspected, prior to unloading. The person receiving the cause cracking from relatively minor impacts. Also plastic
pipe must look for any transportation damage cause by cause cracking from relatively minor impacts. Also plastic
over-tightened tie-down straps, improper treatment, or a pipe becomes more brittle as the temperature decrease.
shift in the load. The impact strength and flexibility of PVC and pipe are
Pipe received in a closed trailer must be inspected as the reduced. Therefore take extra care when handling skids or
trailer is opened. Take extra time to ensure that the pipe loose lengths when the temperature drops below 50°F.
has not been damaged by other materials having been
stacked on top of it, load shift, or rough handling. Storing Pipe
Visually examine the pipe ends for any cracks, splits, If possible, pipe should be stored inside. When this is not
gouges, or other forms of damage. Additionally, the pipe possible, the pipe should be stored on level ground which
should be inspected for severe deformation which could is dry and free from sharp objects. If different schedules of
later cause joining problems. The entire inside diameter pipe are stacked together, the pipe with the thickest walls
of lager diameter pipe (4” and above) must be checked for should be on the bottom.
any internal splits or cracks which could have been caused If the pipe is pallets, the pallets should be sacked with the
by loading or transit. The use of a flashlight may be pallet boards touching, rather than pallet boards being
necessary to perform this inspection. placed on the pipe. This will prevent damage to or bowing
Any damages must be observed by all parties involved, of the pipe.
including the driver, and should be clearly noted on the If the pipe is stored in racks it should be continuously
bill of lading and/or delivery ticket. A copy of this supported along its length. If this is not possible, the
document should be retained by the receiver. In addition, spacing of the supports should not exceed their feet (3”)
the manufacturer and carrier should be notified, within The pipe should be protected from the sun and be in an
24 hours of any damages, shortages, or miss-shipped area with proper ventilation. This will lessen the effects of
products. ultraviolet rays and help prevent heat buildup.
Handling Pipe
The pipe should be handled with reasonable care.
Because thermoplastic pipe is much lighter in weight than
metal pipe, there is sometimes a tendency to throw it
around. This should be avoided.
The pipe should never be dragged or pushed from a truck
bed. Removing and handling pallets of pipe should be
done with a forklift. Loose pipe lengths require special
handling to avoid damage. Precautions to follow when
unloading and handling loose pieces include not banging
lengths together or dropping lengths, even from low
heights, on hard or uneven surface.
In all cause, severe contact with any sharp objects (rocks,
angle iron, forks on forklifts, etc.) should be avoided. Also
the pipe should never be lifted or moved by inserting the
forks of a forklift in to the pipe ends.
Handling PVC pipe particularly diameter greater than 4-
MARKING:
Kawsar Pipes are marked by ink jet stamping at one meter length as shown below:
Standards of Kawsar Pipes marking start from this sequence
Kawsar Trade Mark # 212412 (size) (class) (standard) date time shift A or B.
NOTE:
Dear Customer, Please do not buy any of our products without our Registered Trade Mark # 212412. Please try
to buy / contact our registered offices/ Distributors mention on our website and Last Title back page of our
catalogues for their addresses and contact Details because some people Miss use our brand name illegally. We
just want to deliver you the best Quality Products with full technical support and cooperation.
Physical Properties of PVC Materials
Above data is based upon information provided by the raw material manufactures. It should be used only as a
recommendation and not as a guarantee of performance. Underwriters Laboratories standard.
ELECTRICAL
Dielectric Constant (800 Cycle) 3.0
Dielectric Strength 425 Volts/mil
Inflammability will not support combustion
Water Absorption 0.07 %
(24 Hours at Ambient Temperature)
Range & Standard of KAWSAR PVC Pipes
Kawsar PVC pipes are manufactured in the following standard and range.
PVC Fittings
ASTM D 2466 Pressure Fittings
ASTM D 2665 DWV Fittings
ASTM F512 Fabricated Fittings and Long Elbows
Product Specifications
System: PVC Schedule 40 Pressure Pipe and Fittings System
Scope: This specification covers PVC Schedule 40 pipe and fittings for pressure applications. This
system is intended for pressure applications where the operating temperature will not exceed 140° F.
Specification: Pipe and fittings shall be manufactured from virgin rigid PVC (polyvinyl chloride) Vinyl
compounds with a Cell Class of 12454 as identified in ASTM D 1784.
PVC Schedule 40 pipe shall be iron Pipe Size (IPS) conforming to ASTM D 1785. PVC Schedule 40 fittings shall
conform to ASTM D 2466. Pipe and fittings shall be manufactured as system.
Installation shall comply with the lasts installation instructions published by Kawsar Pipe and Foundry and shall
conform to all applicable plumbing, building, and fire code requirements. Buried pipe shall be installed in
accordance with ASTM F 1668 and ASTM D 2774. Solvent cement joints shall be made in a two-step process with
primer conforming to ASTM F 656 and solvent cement conforming to ASTM D 2564. The system shall be protected
from chemical agents, fire stopping materials, thread sealant, plasticized vinyl products, or other aggressive
chemical agent not compatible with PVC compounds. Systems shall be hydrostatically tested after installation.
WARNING! Never test with or transport/store compressed air or gas in PVC pipe or fittings.
Reference Standards:
Short Specification:
Pipe and fittings shall be manufactured from PVC compound with a cell class of 12454 per ASTM D 1784 and conform with International
standards 14 and 61. Pipe shall be iron pipe size (IPS) conforming to ASTM D 1785. Fittings shall conform to ASTM D 2466.
All pipe and fittings shall be produced by a single manufacturer and shall be installed in accordance with manufacturer's recommendations
and applicable code requirements. Buried pipe shall be installed in accordance with ASTM F 1668 and ASTM D 2774. Solvent cements shall
conform to ASTM D 2564 primer conform, to ASTM 656. The system is to be manufactured by Kawsar Pipe Company and is intended for
pressure applications where the temperature will not exceed 140°F.
Product Specifications
System: PVC Schedule 40 Solid Wall Pipe and PVC DWV Fitting System
This specification cover PVC Schedule 40 solid wall pipe and PVC DWV fitting used in sanitary drain, waste, and
vent (DWV), sewer, and storm drainage applications. This system is intended for use in non-pressure application
where the operating temperature will not exceed 140°F
Specification: Pipe and fitting shall be manufactured from virgin rigid PVC (polyvinyl Chloride) vinyl compounds
with a Cell Class of 12454 as identified in ASTMD D 1784.
PVC Schedule 40 pipe shall be Iron Pipe Size (IPS) conforming to ASTM D 1785 and ASTM D 2665. PVC DWV fittings
shall conform to ASTM D 2665. All system shall utilize a separate waste and vent system.
Installation shall comply with the latest installation instructions published by and shall conform to all applicable
plumbing, building, and fire code requirements. Buried pipe shall be installed in accordance with ASTM D 2321
and ASTM F 656 and solvent cement conforming to ASTM D 2564, the system shall be protected from chemical
agents, fire stopping materials, thread sealant, plasticized vinyl products, or other aggressive chemical agent not
compatible with PVC compounds. System shall be hydrostatically tested after installation.
WARNING! Never test with or transport/store compressed air or gas in PVC pipe or fittings.
Referenced Standards:
ASTM D 2665 PVC Drain, Waste, and Vent Pipe & Fittings
Short Specification:
Pipe and Fittings shall be manufactured from PVC compound with a cell class of 12454 per ASTM D 1784 and conform to International
standard 14. Pipe shall be iron pipe size (IPS) conforming to ASTM D 1785 and ASTM D 2665.
All pipe and fittings shall be produced by a single manufacturer and shall be installed in accordance with manufacturer's recommendations
and applicable code requirements. Buried pipe shall be installed in accordance with ASTM D 2321 and ASTM F 1668. Solvent cements shall
conform to ASTM D 2564; primer shall conform to ASTM F 656. The system is to be manufactured by Kawsar Pipe Company and is intended
for non-pressure drainage applications where the temperature will not exceed 140°F.
PVC SCH-40 ASTM D 2665 & 1785
Outside Diameter, Wall Thickness & Tolerance for PVC Pipe Schedule 40
! NOTE: A
Testing with or use of compressed air or gas in PVC pipe or fittings can result in explosive failures and cause severe injury or death.
Never test with or transport / store compressed air or gas in PVC pipe or fittings with compressed air or gas, or air over water boosters.
Product Specifications
Installation shall comply with the latest installation instructions published by Kawsar Pipe and shall conform to all
applicable plumbing, building, and fire code requirements. Buried pipe shall be installed in accordance with
ASTM F 1668 and ATM D 2774. Solvent cement joints shall be made in a two-step process using IPS P-70 or 0atey
Industrial Grade premiers and solvent cement conforming to ASTM D 2564. The system shall be protected from
chemical agents, fire stopping materials, thread sealant, plasticized vinyl products, or other aggressive chemical
agents not compatible with PVC compounds. Systems shall be hydrostatically tested after installation.
WARNING! Never test with or transport/store compressed air or gas in PVC pipe or fittings.
Referenced Standards:
Short Specification:
Pipe and fittings shall be manufactured from PVC compound with a cell class of 12454 per ASTM D 1784 and conform with International
standards 14 and 61. Pipe shall be iron pipe size (IPS) conforming to ASTM D 1785. Socket fittings shall conform to ASTM D 2467. Threaded
fitting shall conform to ASTM D 2464 or D 2467. Flanges shall be 150# type per ANSI/ASME B 16.5.
All pipe and fittings shall be produced by a single manufacturer and shall be installed in accordance with manufacturers recommendations
and applicable code requirements. Buried pipe shall be installed in accordance with ASTM F 1668 and ASTM D 2774. Solvent cements shall
conform to ASTM D 2564, primer shall be IPS – P 70 or 0atey Industrial Grade. The system is to be manufactured by Kawsar Pipe Company
and is intended for pressure applications where the temperature will not exceed 140°F.
16
PVC PRESSURE PIPE SCH-80 ASTM D 1785
Outside Diameter, Wall Thickness & Tolerance for PVC Pipe Schedule 80
! NOTE: A
Testing with or use of compressed air or gas in PVC pipe or fittings can result in explosive failures and cause severe injury or death.
Never test with or transport / store compressed air or gas in PVC pipe or fittings with compressed air or gas, or air over water boosters.
NOM. ASTM SOCKET ENTRANCE (A) SOCKET BOTTOM (B) SOCKET LENGTH (C)
Pipe Size Standard I.D Min I.D Max. I.D Min I.D Max. Schedule 40
ASTM D2665
Minimum Hydrosratic Burst Pressure at 73oF (23o) Temperature De-Rating For Schedule 40 & 80 PVC
Minimum Hydrostatic Burst Pressure (1 PSI = 6.89 kpa)
The operator pressure of PVC pipe will be reduced as the operating
Size PSI KPI temperature increases above 73°F. To calculate this reduction, multiply
the operating pressures pages by the correction factors shown below.
1¼ 1180 8140
Operating Correction
1½ 1060 7310 Temperature (°F) PVC
2 890 6140
3 840 5790
73
4 710 4900 1.00
6 560 3680 80 .88
8 500 3450 90 .75
10 450 3100 100 .62
12 420 2890 110 .50
14 410 2830 120 .40
16 410 2830 130 .30
18 410 2830 140 .22
20 390 2690 150 NR
24 380 2620
160 NR
* These burst pressure are calculated using a 170 NR
hoop stress of 6400 psi (44.1 MPA) 180 NR
200 NR 19
www.kawsarpipe.com / Tel:+92-91-5830010
Product Specifications
System: PVC SDR Pressure Pipe and Fitting System
Scope: This specification covers PVC Standard Dimensional Ratio (SDR) pipe and fittings for pressure
applications. This system is intended for pressure applications where the operating temperature will not exceed
140°F.
Specification: Pipe and fittings shall be manufactured from virgin rigid PVC (polyvinyl chloride) vinyl compounds
with a Call Class of 12454 as identified in ASTMD D 1784.
PVC SDR pipe shall be iron Pipe Size (IPS) conforming to ASTM D 2241 for plain end pipe and ASTM D 2672 for
belled-end pipe. PVC Schedule 40 (IPS) fittings shall conform to ASTM D 2466. Pipe and fittings shall be
manufactured as a system.
Installation shall comply with the latest installation instructions published by Kawsar Pipe and shall conform to all
applicable plumbing, building, and fire code requirements. Buried pipe shall be installed in accordance with
ASTM F 1668 and ASTM D 2774. Solvent cement joints shall be made in a two-step process with primer
conforming to ASTM F 656 and solvent cement conforming to ASTM D 2564. The system shall be protected from
chemical agents, fire stopping materials, thread sealant, plasticized vinyl products, or other aggressive chemical
agents not compatible with PVC compounds. System shall by hydrostatically test after installation. WARNING!
Never test with or transport/store compressed air or gas in PVC pipe or fittings.
Referenced Standards:
ASTM D 1784 Rigid Vinyl Compounds
ASTM D 2672 Joints for IPS PVC Pipe Using Solvent Cement
2" 60.32 -- -- 1.85 2.31 2.87 3.56 4.47 Only use PVC pipe for water or
approved chemicals.
21/2" 73.02 -- -- 2.24 2.79 3.48 4.29 5.41
Refer to warnings in PPFA User bulletin
3" 88.9 -- 2.16 2.74 3.43 4.24 5.23 6.58
4-80 and ASTM D 1785.
4" 114.3 1.78 2.79 3.51 4.39 5.44 6.73 8.46
5" 141.3 2.64 3.45 4.34 5.43 6.73 8.3 10.1
6" 168.28 2.64 4.11 5.18 6.48 8.03 9.91 12.47
NOTE:
8" 219.08 3.43 5.33 6.73 8.43 10.41 12.9 --
Dear Customer, Please do not
10" 273 -- 6.65 8.41 10.5 12.98 -- -- buy any of our products without
our Registered Trade Mark #
12" 323.9 -- 7.9 9.96 12.5 15.39 -- -- 212412
www.kawsar.com.pk Contact:
14" 355.6 -- 8.95 -- 13.7 -- -- -- +92-91-5822809-5830010
Referenced Standards:
Perforated pipe is supplied with two rows of ½” diameter holes every five inches. Rows are parallel to the pipe axis and
are 120° apart.
Weight is approximate and is for shipping purposes only.
Pipe listed in this section meets or exceeds the requirements of ASTM D 2729
Failure to follow safety precautions may result in misapplication or improper installation and
NOT FOR PRESSURE testing which can cause severe personal injury and / or property damage.
! Primers and cements are extremely flammable and may be explosive. Do not store or use
! Do not use PVC Sewer pipe for pressure applications. The use
WARNING
near heat or open flame, or death or serious injury may occur.
Solvent fumes created during the joining process are heavier than air and may be trapped
of sewer pipe in pressure applications may result in system in newly installed piping systems.
NOTICE Ignition of the solvent vapors caused by spark or flame may result in injury of death from
failure and property damage. explosion or fire.
Read and obey all manufacturers' warnings and any instructions pertaining to primers and
cements.
Provide adequate ventilation to reduce fire hazard and to minimize inhalation of solvent
vapors when working with Cements, primers and new piping systems.
24
PVC SEWERAGE PIPE
BS-5255, 4514, 4660 & 5481
Non
Pressure
3" 88.7 89.1 2.9 1.17 3.5 1.41 4.6 1.82 5.7 1.58 1.8 2.2 Refer to warnings in PPFA User bulletin
4" 114.1 114.5 3.4 1.78 4.5 2.32 6.0 3.03 7.3 2.22 2.3 2.8 4-80 and ASTM D 1785.
5" 140.0 140.4 3.8 2.44 5.5 3.49 7.3 4.55 9.0 3.65 2.6 3.1
6" 168.0 168.5 4.5 3.46 6.6 5.01 8.8 6.57 10.8 5.51 3.1 3.7
7" 193.5 194.0 5.2 --- 7.7 — 10.1 — 12.4 — 3.1 3.7
8" 218.8 219.4 5.3 5.30 7.8 7.72 10.3 10.05 12.6 12.17 3.1 3.7
3.1
NOTE:
9" 244.1 244.8 5.9 --- 9.7 — 11.5 — 14.1 — 3.7
Dear Customer, Please do not
10" 272.6 273.4 6.6 8.26 9.7 11.97 12.8 15.59 15.7 18.89 3.1 3.7 buy any of our products without
12" 323.4 324.3 7.8 11.55 11.5 16.85 15.2 21.91 18.7 26.68 3.1 3.7 our Registered Trade Mark #
212412
14" 355.0 356.0 8.5 13.87 12.6 20.27 16.7 26.49 20.5 32.16 3.6 4.2 www.kawsar.com.pk Contact:
16" 405.9 406.9 9.7 17.90 14.5 26.43 19.0 34.15 23.4 46.61 4.1 4.8 +92-91-5822809-5830010
18" 456.7 457.7 11.0 22.80 16.3 33.34 21.4 43.33 — — 4.6 5.3
20" 507.5 508.5 12.2 28.08 18.1 41.16 — — — — 5.1 5.9
22" 558.3 559.3 13.4 34.02 22.9 49.80 — — — — 5.3 6.1
24" 609.1 610.1 14.6 40.41 21.7 59.27 — --- — — 5.5 6.3
—
26
DIN 8061 & 8062
Minimum Wall Thickness & Weight
110 1.8 0.95 1.9 1.160 3.2 1.640 5.3 2.610 8.2 3.900
125 1.8 1.08 2.5 1.480 3.7 2.130 6.0 3.340 9.3 5.010
140 1.8 1.21 2.8 1.840 4.1 2.650 6.7 4.180 10.4 6.270
NOTE:
Dear Customer, Please do not
160 _ 1.8 1.39 3.2 2.410 4.7 3.440 7.7 5.470 11.9 8.170 buy any of our products without
our Registered Trade Mark #
200 1.8 1.74 4.0 3.700 5.9 5.370 9.6 8.510 14.9 12.800 212412
www.kawsar.com.pk Contact:
225 _ 1.8 1.96 4.5 4.700 6.6 6.760 10.8 10.800 16.7 16.100 +92-91-5822809-5830010
250 2.0 2.40 4.9 5.650 7.3 8.310 11.9 13.200 18.6 19.900
280 2.3 3.11 5.5 7.110 8.2 ' 10.400 13.4 16.600 20.8 24.900
315 2.5 3.78 6.2 9.020 9.2 13.200 15.0 20.900 23.4 31.500
400 3.2 6.10 7.9 14.500 11.7 21.100 19.1 33.700 29.7 50.800
500 4.0 9.38 9.8 22.400 14.6 32.900 23.9 52.600 - -
630 5.0 14.70 12.4 35.700 18.4 52.200 30.0 83.200 - -
710 5.7 18.90 14.0 45.300 20.7 66.100 - - - -
27
PVC WELL CASING / SCREEN PIPES
Kawsar Casing & Screen pipes ensure that the water well remains a perennial source of clean water. Some Year
ago the choice was only was metal pipe and Screens. The disadvantages were corrosion of casing pipes,
determination of screens and formation of bacteria, resulting in abandonment of wells and, even worse
contamination of the water source.
Pvc well casing and screen is widely used because it is light strong, easy to install durable corrosion resistance
and relatively inexpensive . The choice of any material depend upon its strength and weakness in relation to
the particular intended use .Condition at a water well drilling site and within a borehole or generally
aggressive. PVC casing and screens is easily able to with stand most condition but it is important for a driller
engineer or hydro geologist to be aware of conditions or circumstances that might prejudice the integrity of
PVC and consequently the bore hole. The aim is to provide a basis for the correct selection and handling of PVC
casing and screen.
PVC is a plastic. it has a low compressive and tensile strength related to steel. It can be a softened by heat,
deform by sudden or gradual stress and shattered by strong impact. Generally PVC casing is stronger than PVC
screen, and thick wall Pvc casing is stronger than thin walled casing.
PVC is much more flexible than steel, therefore it should be supported both on the ground and in the
boreholes. It strength can be reduced by prolonged exposure to strong sunlight. It is attacked by solvent such
as vinyl chloride. Volatile organic chemicals can pass through PVC by a process that is not fully understood.
Today the modern technologies have enabled us to makes use of plastic pipes for this application.
ADVANTAGE
RESISTANCE TO EXTERNAL &INTERNAL PRESSURE:
Maximum hydraulic loading on casing pipes occurs during
installation, grave packing, back filling and development
of water wells. Hydrostatic pressure is caused by the
column of drilling fluid of water present in the borehole .
Rapid installation of a gravel pack or back fill increases the
pressure on casing and screens pipes .Bridging and later
collapse of gravel or backfill into the borehole can further
subject casing pipes and screens pipes to shock loads.
Poor mud control during water well development can
also subject the casing to hydrostatic of differential
pressure loading.
RESISTANCE TO CORROSION
All Kawsar PVC pipes are resistance to corrosion. As PVC is
inherently more resistance than conventional steel
products to clogging and encrustation, at a fraction of the
cost .Kawsar PVC screen pipes are generally unaffected by
substances encountered in well: hence no deteriotion in
slots takes place. The raw material used for
manufacturing fully complies with drinking water
regulation and does not affect the quality of water.
LONG LIFE:
Well rehabilitation cost are minimized, as PVC screens are
TYPES OF SCREEN DESIGN
Kawsar Slotted screens are obtained by making cuts all over the PVC pipe in order to exploit the screen collecting
capability to maximum level. Slots are horizontal to pipes generatricles. Data show that horizontal opening are
very hydraulically efficient and provide high collapse resistance thanks to the arc shapes of the material around
them.
PVC slotted screens are usually used in fine soils to build up artesian wells, for drainage etc.
The product is manufactured according to customers need: the slots length and the number depend on the
requested open area, moreover, cuts can be made on one, two, three or four sides of the pipes whereas the slots
width is related to soil granulometry.
VERTICAL SCREEN
HORIZENTAL SCREEN
PERFORATED SCREEN
SLOTTED PIPE
.006 .008 .010 .012 .015 .020 .025 .030 .040 .050 .060 .080 .100 .125 .180 .250 .500
SLOT
WIDTH
SLOT LENGTH
SLOT LENGTH
OUTSIDE
INSIDE
SLOT
SPACING
Dear Customer, Please do not buy any of our products without our Registered Trade Mark # 212412
NOTE: www.kawsar.com.pk Contact: +92-91-5822809-5830010
KAWSAR SCREEN/SLOTED PIPE QUOTE REQUEST
Diameter: Sch. / SDR: O.D.: I.D.: Min. Wall:
NOA (in Square Inches / Foot): NOA (as a % of inside surface area):
Quantities:
Phone: ( ) Fax: ( )
Please kindly visit our website for REQUEST FORM
34
Pvc Pressure And Strength Tables
Testing methods and procedures used are in compliance with ASTM F480 standards for thermoplastic pipe in all applicable areas.
Notes:
1. Values noted with an asterisk (*) are based on minimum wall & include a 50% safety factor.
2. Values noted with a double asterisk (**) are recommended dry hanging weight for threaded PVC schedules 40 & 80.
These values are calculated based on the minimum cross sectional areas of either the box or pin thread portion of the joint
after machining. The resulting minimal area was multiplied by 7,000 psi tensile strength per ASTM D-1784 to yield the
recommended dry hanging weight. even through these calculated values are lower than actual Johnson screens test data.
Johnson recommends not to exceed the above values for well construction.
Dear Customer, Please do not buy any of our products without our Registered Trade Mark # 212412
NOTE: www.kawsar.com.pk Contact: +92-91-5822809-5830010
JOINTING TYPES
Fix the centering guides the pipes once in every 15 meters (minimum), just below the neck of the
socket, with the open end of the centering guides facing upwards while lowering .
Always use a plain casing pipe (sand trap) for the first pipe to be lowered, with a conical end
cap(Bull-nose) blanking the spigot end of the pipe. Fill this pipe with water or drilling fluid before
lowering into the well.
Wash the remain borehole thoroughly with fresh drilling fluid (Bentonite Solution) for 40 – 45
minutes from the bottom , keeping the specific gravity of the drilling fluid to below 1.4
This will prevent heavy sedimentation at the bottom of the borehole and also easy lowering of the
assembly.
To obtain better result, ensure that the reamed borehole is at least 15 to 20cms more than the
outside diameter of the casing pipe.
The Sand trap is the lowest pipe in a tubewell and is the first to be selected. Fit this pipe with an end
plug (cap) and centering guide.
Lower the sand trap into the borehole and hold with a split clamp with the socketed end facing
upward.
The next pipe, which is either a screen pipe or a plain pipe(depending on lithology of well ) is fitted to
sand trap by screwing them together.
36
Jointing pipe can be done either by strap wrench or with manila rope. Never used a chain range.
Clean the threads to remove mud or burrs using wire brush. Soap solution maybe used to
lubricate the joints Avoid grease or waste oil.
Fit the socked end of the next pipe (Which can be a screen /plain casing) with the fitting cap.
Connect the lifting cap securely with the wire rope of the drilling fram. Use winch of drilling
machine to lift the threaded pipe string.
This pipe string is jointed to the pipe already lowered into the borehole.
Center the assembly pipe string and permit it to descend into the borehole by releasing the split
clamp, Fill the pipe with water or mud solution to equalize pressure.
Repeat the operation till all the casing and screens are lowered according to the lithology of the
well. The time needed to make each joint is less than 5 minutes.
Lowering time can be reduced by the casing and screens on the ground to make additional
lengths. Do this correctly as per lithology of the well to avoid wrong placement of screens in the
bore well.
Do not set the lowered pipe assembly at the bottom of the borehole. Ensure at least 10 feet of
free bore below the sand trap. This help the lowered casing and screen pipes to remain hanging
and achieve a vertical installation.
Centering guides should always be fixed at a minimum interval of 1.5 meter to ensure uniform
gravel asking around the casing and screen pipes.
KAWSAR Well casing are made available up on orders within shortest possible time period in
vertical & horizontal slots along the length, however customized screening pipes provided with
pores can also be produced fulfilling all requirements while considering
requisite technical parameters.
37
www.kawsarpipe.com / Tel:+92-91-5830010
Product Specification
SCOPE
This specification designates general requirements for 5" through 6" diameter polyvinyl chloride (PVC) Electrical
Conduit and Power Duct pipe for the conveyance of electrical wires in above/below ground and/or indoor
applications.
KAWSAR offers a complete line of Electrical Conduit and Power Duct pipe products which include: Schedule 40 and 80
Conduit (NEMA TC-2, ANSI/UL651), Encased and Direct Burial Conduit (ASTM F512, NEMA TC-6 & 8 and/or ANSI/UL
651A), and Type C Telephone Duct. All KAWSAR Electrical Conduit and Power Duct pipe products are offered in 4
meters laying lengths (10 foot and 20 foot lengths are also manufactured on special order by customer. This means
that more ground can be covered during installation while eliminating the cost of unnecessary joints.
PVC MATERIALS
KAWSAR Schedule 40 and 80 Electrical Conduit shall be made from quality PVC resin, compounded to
provide physical and mechanical properties as defined in ANSI/ UL 651 and NEMA TC-2.
Reference Standards:
ASTM D 1784 Rigid Vinyl Compounds
ASTM D 1785 PVC Plastic Pipe, Schedule 40
ASTM D 2466 PVC Plastic Fittings, Schedule 40
ASTM D 2564 Solvent Cements for PVC Pipe and Fittings
ASTM D 2774 Underground Installation of Thermoplastic Pressure Piping
ASTM F 656 Primers for PVC Pipe and Fittings
ASTM F 1668 Procedures for Buried Plastic Pipe
39
Multi Conduit PVC Pipes
These guidelines should help you install Multi Conduit in the simplest way possible and should be read
in their entirety before attempting to install the system to haveas smooth an installation as possible.
To be certain that the conduit has been properly placed, the conduit work should be inspected
throughout the construction period by a trained inspector who is completely familiar with the job and
construction specifications. The inspector should confirm the Multi Conduit run is in the correct location,
proper conduit depth is maintained, the trench bottom is level, all
joints are properly made, horizontal and vertical alignment is
maintained and select backfill is used.
40
www.kawsarpipe.com / Tel:+92-91-5830010
APPLICATIONS ADVANTAGES
Underground and Above Reliable Joints & easy pull through
Ground Electric Supply Light weight Easy to Install
Data Transmission Fire Resistance
Telecommunication Non Magnetic
Power Transmission lines Non CorrosiveSafety
KAWSAR produces a wide variety of conduit pipe suitable for most applications. KAWSAR Schedule 40 and 80
products are rated for 90° C conductors and conform to ANSI/UL 651 and NEMA TC-2. This conduit is designed
with safety in mind and can be used in a variety of everyday applications. KAWSAR offers telephone duct for
networking applications. KAWSAR telephone duct is made in compliance with ASTM F512 and/or other
specified specifications for consistencyand safety.
CORROSION RESISTANCE
KAWSAR Electrical Conduit unaffected by electrolytic or galvanic corrosion, or any known corrosive soil or water
condition.
SMOOTH INTERIOR
This PVC pipe has a smooth interior that allows for wires to be pulled through easily without hanging or binding. KAWSAR
pipe is carefully designed and manufactured to provide an interior surface that will not nick or tear the wiring insulation.
41
www.kawsarpipe.com / Tel:+92-91-5830010
EPT-A-PVC Electrical Plastic Tubing for encasement in concrete | EPC 40 Electrical Plastic Conduit for normal duty application | EPC 80 Electrical Plastic Conduit for heavy-duty application
Type EB for Encased Burial in concrete Type DB for Direct Burial without Concrete Pipe Length: Standard 6 meters (6m)
Dear Customer, Please do not buy any of our products without our Registered Trade Mark # 212412
NOTE: www.kawsar.com.pk Contact: +92-91-5822809-5830010 42
www.kawsarpipe.com / Tel:+92-91-5830010
PROPERTIES
MECHANICAL PROPERTIES
ASTM TYPICAL VALUE
THERMAL PROPERTIES
ASTM TYPICAL VALUE
Coefficient of Thermal
D696 5.13 x 10-5
Expansion – in/in C
Coefficient of Thermal
D696 3.0 x 10-5
Expansion – in/in 0F
Deflection Temp. 0F Under
D648 140 0F
Load @ 264 psi
Thermal Conductivity
C177 1.3
BTU (hr) (ft) (0F/In)
ELECTRICAL PROPERTIES
Dielectric Strength
D149 1,100
Volts/mil
Dielectric Constant
D150 4,00
60 CPS @ 30 C
Power Factor
D150 1,93
60CPS @ 30C
Maximum Space
Size
Between Supports (ft)
1 1/4 - 2 5
2½-3 6
3½ - 5 7
6 8
43
www.kawsarpipe.com / Tel:+92-91-5830010
BS-6099
KAWSAR PVC Electrical Conduit Pipes as per BS-6099
Nominal Size Outer Diameter (mm) Wall Thickness
44
www.kawsarpipe.com / Tel:+92-91-5830010
17.0
21.5
26.9
33.7
42.2
60.5
89.1
114.5
45
www.kawsarpipe.com / Tel:+92-91-5830010
The chart below shows approximate friction losses, in equivalent feet, for variety of Schedule 40 & 80 PVC fittings of different sizes.
Approximate Friction Loss For PVC Fittings In Equivalent Feet Of Straight Pipe
Fitting ½” ¾” 1” 1¼” 1½” 2” 2½” 3” 4” 6” 8”
Tee (Run) 1.0 1.4 1.7 2.3 2.7 4.3 5.1 6.2 8.3 12.5 16.5
Tee (Branch) 4.0 5.0 6.0 7.3 8.4 12.0 15.0 16.4 22.0 32.7 49.0
90° Elbow 1.5 2.0 2.5 3.8 4.0 5.7 6.9 7.9 12.0 18.0 22.0
45° Elbow .80 1.1 1.4 1.8 2.1 2.6 3.1 4.0 5.1 8.0 10.6
Male/Female Adapter 1.0 1.5 2.0 2.75 3.5 4.5 5.5 6.5 9.0 14.0 ----
The table on page shows friction heads in feet and friction losses in psi for schedule 40 pipe. It also shows the gallons per minute (GPM) and
velocities (in feet per second) for various pipe sizes.
www.kawsarpipe.com / Tel:+92-91-5830010
Water Hammer
Water hammer is a term used to describe the sudden increase
in pressure created by quickly stopping, starting, or changing
How To Use The Nomograph On The
the direction of the flow of fluid in piping system. Typical Following Page.
actions which cause water hammer are:
1. Quick closing a valve. 1. Liquid Velocity (feet/second), pipeline length (feet), and
2. Quick Opening a valve. valve closing time (seconds) must be known.
3. Starting pumps with an empty discharge line. 2. Place a straight edge on the liquid velocity in pipe (line A)
4. A high speed wall of liquid (such as starting a and the pipeline length (line D).
pump) suddenly charges direction (such as 3. Mark intersection of straight edge with pivot line (line C).
going through a 90° elbow). 4. Place straight edge on mark just placed on pivot line (line
5. Moving entrapped air through the system. C) and on valve closing time for valve being used (line A).
5. The intersection of the straight edge with the pressure
The pressure increase generated must be added to the fluid increase line (line B) is the liquid momentum surge
pressure already existing in the piping system to determine the pressure (water hammer).
total pressure the system must, withstand. CAUSTION! If water The liquid momentum surge pressure should be added to the
hammer is not accounted for, the sudden pressure surge could e operating line pressure to determine the system's maximum
enough to burst the pipe, or break the fittings or valves. line pressure. The maximum line pressure is used to select the
proper piper schedule or wall thickness.
Taking the following measures will help prevent problems:
The nomograph is based on the formula
(1) Keep fluid velocities under 5 feet per second.
(2) Use actuated valves with controlled opening and P= 0.070VL
closing speeds. T
(3) Instruct operator of manual valves on the proper Where P is increase in pressure due to momentum surge in psi, L is
opening and closing speeds. inline length in feet, V is liquid velocity in feet per second, and T is
(4) When starting a pump, partially close the valve in the valve closing time in seconds.
discharge line to minimize the volume of liquid
accelerating through the system. Fully open the valve
after the line is completely filled.
(5) Use a check valve in the pipe line, near the pump to keep
the line full.
(6) Use air relief valves to control the amount of air that is
admitted or exhausted throughout the piping system.
(7) Design the piping system so that the total pressure
(operating plus water hammer surge) does not exceed
the pressure rating of the lowest rated of the lowest
rated component in the system.
www.kawsarpipe.com / Tel:+92-91-5830010
15.0 15.0
500 500
Cla
Cl
12.0 12.0
ss-
as
Cla
s-E
E
WORKING PRESSURE BARS
400 400
WORKING PRESSURE FT. HD
Cl
as
s-
9.0 9.0
D
C
Cl
Cl
as
300 s-C 300
B
3.0 3.0
100 100
0 0
20 40 60 80 20 40 60 80
TEMP oC TEMP oC
50
www.kawsarpipe.com / Tel:+92-91-5830010
Earth Load
Wheel Load
INSTALLATION / JOINTING PROCEDURE
More applications of primer may be required on hard Do not allow cement to puddle or accumulate inside the
surfaces or cold weather conditions. system.
Once the surface is primed remove all puddles of excess Solvent cement should conform to the appropriate
primer from the ftting socket. ASTM standard for the piping system as shown in the
accompanying table. All purpose cement is not recom
-
Cement must be applied while primer is wet. mended
Stir or shake the cement prior to use.
52
Join Pipe and Acceptable tools
Fittings include recipro -
Assemble pipe cating saw, me -
and fttings quick- chanical cut off saw with carbide tipped blade or other
ly while cement is appropriate tool.
fuid. If cement If any indication of damage or cracking is evident at the
has hardened, cut (tube / pipe) end, cut off at least 2" of pipe beyond any
pipe, dispose of visible cracks.
fitting and start
over. 2. Remove Burrs
and Bevel
Insert pipe into
the fitting hub Remove all pipe
giving a quarter turn as the pipe is being inserted, ensur
- burrs from inside
ing an even distribution of the cement within the joint. and outside diam -
Do not quarter turn the pipe after contact with socket eter of pipe with a
bottom. de-burring tool.
Once the pipe contacts the socket bottom hold pipe and Chamfer (bevel)
ftting together until the pipe does not back out. the end of the pipe
10° - 15°. Pow -
See table for recommended set and cure times. ered and manual
Remove excess-ce chamfering tools
ment from the ex- are available.
terior. A properly 3. Clean and Dry
made joint will Pipe and
show a continuous Fittings
bead of cement
around the pe - Remove surface
rimeter. If voids dirt, grease or
appear sufficient moisture with a
cement may not clean dry cloth.
have been applied
and joint failure
may result.
53
5. Dry Fit 9. Coat Surface with Cement
With light pres - Cement must be applied while primer is wet. It is ideal
sure, pipe should if one mechanic applies the primer while a second im-
go one half to one mediately applies the cement.
third of the way Stir or shake the cement prior to use.
into the fitting
hub. Pipe and Apply a full even
fittings that are layer of cement
too tight or too to the pipe sur -
loose should not face to a point ½"
be used. beyond the hub
depth. Aggres -
sively work the
6. Applicator
cement into the
Use an applicator surface.
that is one half
the size of the
pipe's dia meter
Use of an ap -
propriately sized Apply a medium
applicator will layer of cement to
ensure that ad- the fitting sock -
equate cement is et aggressively
applied. Natural working it into
bristle brushes or the surface. On
swabs are recom - bell end pipe do
mended. Rollers are not recommended. not coat beyond
the socket depth.
Too small an applicator will not apply suffcient ce -
ment.
7. Crew Size
10. Join Pipe and Fittings
Working rapidly, especially in adverse weather condi -
tions, will improve installations. For 6" to 8" diameters Assemble pipe and fittings quickly while cement is flu-
a crew size of 2 tomechanics is required. For 10" pipe id. If cement has hardened, cut pipe, dispose of fitting
diameters and larger a crew ofto 4 mechanics may be and start over.
required. It is very impor-
tant that the pipe
8. Coat Surface is fully inserted
with Primer to the fitting stop
at the bottom of
Apply primer to
the fitting. Large
the ftting sock -
diameter pipe is
et aggressively
heavy and can
working it into
develop signifi-
the surface.
cant resistance
during insertion.
The use of a pull-
ing tool designed for plastic piping systems is recom -
mended.
54
CHEMICAL RESISTANCE OF KAWSAR uPVC & PVC PIPES:
PVC Pipes are highly resistant to salt water acids and alkalies. It is not recommended for
use with organic ester, ketones, chlorinated solvents aromatic hydrocarbon and low molecular
weight alcohols.
Resistance of uPVC & PVC Pipes to common chemicals under the conditions.
Mineral Acids Hydrochloric Acid 30% +
Sulphuric Acid 50% +
Sulphuric Acid 98% +
Solvents Acetone -
Methyl Ketone -
Toluene -
Trichloroethylene -
Turpentine +
Xylene -
Soaps & Detergents +
Gases Ammonia +
Carbon Dioxide +
Natural Gas +
Oxygen
55
CONVERSION TABLE
Conversion Conversion
Alternate
Quantity SI Unit Factor U.S. Unit Factor
SI Unit
K 1/K K 1/K
Length M 1 1 In (inch) 39.370 2.54x10-2
ft (foot) 3.281 0.305
mi (mile) 6.214x10-4 1609.344
Viscosity Pas=N s/m2 kfg s/m2 0.102 9.807 lbf s/ft2 0.0209 47.880
(dynamic) cp 1000 0.001 10.764 0.093
Specific Entropy k/kg K kcal/kg oC 2.390x10-1 4.184 BTU / Ibm oR 2.388x10-1 4.187
56
SPECIAL THANKS TO
POLYMERS STRUCTURE & PROPERTIES
(By C.A. Daniels, Ph.D. Senior Materials Engineers, USA)
We have tried to make this catalogue error free, however suggestions and
recommendations to improve the contents and materials will be highly appreciated.
58
is not Kawsa
p ipe rp
ip
tic
e,
s
la
yp
PIPE
Ever
AR
K AWS
DEALERS
KABUL MAIN WAREHOUSE: LOGAR: HELMAND OFFICE:
Kabul Logar Road, Binihisar Qalai Wazir Opposite of Logar Lashkare Gah City Jade-e-Khyber Opp.
Phone:-0202200901 Jame Masjid Logar. at Haji Ubaidy Market.
Cell: 0799010108-0789007075-0777282028 Cell:- 070074078 Cell: 0700487141 / 0798160812
alkawsar.af@gmail.com
PUL-E-KHUMRI:
GHAZNI DISTRIBUTOR: Former Chowk Baghlan Khwaja
Bazari Mekhcha Farooshi Muhi-U-Din Building Pul-e-Khumri.
Market Mohammad Anwar Ghazni City Cell:0700705749
Cell: 0799231540, 0799395102
KHOAST OFFICE:
KHOAST OFFICE: Markazi choak-e-Ijaz Market,
Sabiqa Ada-e-khoast Bazar, Khoast Bazar Cell: 0799148889
Infront of Madina Market, Cell: 0799115094
For more details about our products, Catalogs or Technical Data Sheet please visit our website