You are on page 1of 27

CST’S EVOLUTION

IN OIL MARKET

BOLTED OIL TANKS


Edward Soley
• Began manufacturing storage tanks in 1893
• Over 375,000 installations of storage tanks and custom
covers in more than 130 countries
• 750 employees worldwide
• $300mm revenue
Parsons, Kansas Winchester, Tennessee

DeKalb, Illinois Alfreton, England

Conroe, Texas Rincon, Georgia


- Corporate Headquarters
- Manufacturing Facilities
- Engineering & Design Center
- Regional office
- Construction Resources
CST’S PRODUCT & APPLICATION
INNOVATION
• Columbian Steel tank company was founded in 1893.
• As originators of sectional steel tanks for petroleum
storage in 1916, the forerunner of the API 12B tank.
• By 1921, Columbian has sold 20,000 of these tanks
and shipped them to 14different countries!
• Over 100,000 tanks supplied…
Today, CST Industries brings the historic sectional
steel tank leadership names into a new & exciting
storage tank company.
Application and product line
• Application
TYPICAL PRODUCTS STORED MARKET SERVED
Crude Oils & sour Marine Distillate Fuels Exploration Selected Refinery Applications
Diesel Fuels Kerosene Production Oil fired power plants
Aviation Fuels Selected Mineral Spirits Pipelines Bunkering facilities
Heavy Fuel Oils Asphalt – Bitumen Terminals Aviation facilities & bases
Drilling Fluids/Mud Produced Water/Brine

• CST’s Petrotec Family:


API 12b - API 12b WITH monogram 100bbls to 10,000Bbls
API 12b+ - API 12b principles up to 35,000Bbls
WHY BOLTED TANK?
Quick assembly Factory applied high grade Robust structural design
coating
Utilization of local semi- Holiday free interior coatings Leak free joint
skilled labor
Rapid delivery Hi performance UV resistant No “hot work” – no welding
exterior or coating
Safe construction method All roof members (sheets, rafters, No X-Ray
clips) 100% factory coated

Perfect for remote locations Underside of floor sheets 100% Highly earthquake resistant
factory coated
Easy to disassemble & Total wall panel material Use of high strength steel for
relocate traceability – sheet by sheet improved economy
Easy to expand Lowest cost of ownership of any Lowest carbon footprint of any
tank type tank type
Low, low maintenance Specialty sealer & gasket Engineered joint configuration.
materials
Thing to consider in using modular
tank in oil market?
1. Design: Does structural design follow accepted industry standard?
2. Joints: are joint reliable and permanently sealed Is joint assembly system able
to be 100% visually confirmed?
3. Coatings: Do coatings offer state of art technology for longest possible life
with least possible maintenance?
4. Installation: Is tank installation simple, quick and safe?
5. Commissioning: Is tank commissioning straightforward, simple and reliable?
6. Maintenance service & repair, ownership value: Will tank offer secure and
reliable service? Will tank maintenance be minimal over an extended period
of time? Does tank offer the lowest possible life time ownership costs?
7. The supplier
1. Design: Does structural design
follow accepted industry standard?

API 12B: Bolted tank according to API 12B standard (Bolted tanks for storage of
production liquids) These are specifically defined by the American Petroleum
Institute with set sizes, steel thicknesses and fabrication requirements.

API-12B Standard Tank Sizes – Capacities with normal Imperial Dimension (Feet)
100bbl – 9 x 8 200bbl – 9 x 16 300bbl – 9 x 24 250bbl – 15 x 8 H500bbl – 15 x 16

750bbl – 15 x 24 L500bbl – 21 x 8 H1000bbl – 21 x 6 1500bbl – 21 x24 L1000bbl – 29 x 8

2000bbl – 29 x 16 3000bbl – 29 x 24 5000bbl – 38 x 24 6700bbl – 54 x 16 10000bbl – 54 x 24


1. Design: Does structural design
follow accepted industry standard?
• Petrotec API12B Range: these are bolted tanks
monogrammed to API 12B (up to 10,000bbl)

• Petrotec API12B+ Range: these are bolted tanks


designed with the principles of API12B (up to
35,000bbl).
API 12B tank - Iraq
3000Bbls
PERTAMINA UBEP –LIRIK API 12B
10,000BBL
TAC-PERTAMINA BWP MERUAPINDONESIA API
12B – 5000 BBL
Pertamina UBEP Ramba- Ramba
Camp. 5000 BBl Fire Water Tank
Erection process API 12B crude Oil Tank.
Bentayan Station Pertamina UBEP ramba
Medco –Ibul Station June 2016 . 3000 BBl Tank
Medco- Matra Station 5000 BBl Capacity. June 2016
1. Design: Does structural design
follow accepted industry standard?
2. Joints: are joint reliable and
permanently sealed?
3. Do coatings offer longest possible
life with least possible maintenance?
4. Installation: Is tank installation
simple, quick and safe?
5. Commissioning: Is it
straightforward, simple and reliable?
• In the rare of join leaks are observed. These can
typically be remedied from exterior without draining
down the tank or taking it out of service.
• Hydrostatic test water be left in the tank 3 – 4 weeks.
For testing purposes.
• After these, the tank can safely & reliably be put into
direct product service.
• CST offers a full range of services for your
installation!!!
6. Maintenance service & repair,
ownership value:

Will tank offer secure and reliable service?

Will tank maintenance be minimal over an


extended period of time?

Does tank offer the lowest possible life time


ownership costs?
Maintenance service & repair,
ownership value:
7. The suppliers

• Is the vendor reliable with a proven track-


record of successful completing significant
industrial projects?
• Are they financially stable and of such size to
accommodate the project requirements?
• Do they offer support service required for the
project?
• Mud Tanks
• Drilling Fluids
• Frac Tanks
• Completion Fluids
• Mixing Tanks
• Flowback Water
• Domes for Terminals
Thank you for your attention!