Via Camp Lonc 25, Z.I. Villapaiera - 32032 Feltre (BL) - Italy
Tel. + 39 0439 3131 - Fax + 39 0439 313300 - info@clivet.it
CLIVET RUSSIA
to ensure sustainable comfort and the well-being of people and the environment.
Designing and developing year-round air conditioning solu- commercial and industrial
comfort and the tions with innovative technologies are part of Clivet's DNA,
which means the company has always been ready for the sectors
well-being of people and future.
the environment
01 02
Contents
05 Overview
07 Features
13 Intelligent Management
14 Specifications
15 Dimensions
Dimensions
and Establishing New Industry Benchmarks
In the 21st century, saving energy and reducing emissions is increasingly important and has become a global drive for sustainable
development. The state is paying closer attention to each unit's the Integrated Part Load Value (IPLV) and advocating high-efficiency, 19 Reference Projects
energy-saving products. Clivet's efficient falling film inverter screw unit adopts several industry-leading technologies, and offers four main
advantages, including its high energy efficiency, low environmental impact, stability and reliability, and intelligent controls.
Certified in accordance with the AHRI Water-Cooled Water-Chilling and Heat Pump
Water-Heating Packages Using Vapor Compression Cycle Certification Program,which is based
on AHRI Standard 550/590(I-P) and AHRI Standard 551/591(SI).Certified units may be found in the
AHRI Directory at www.ahridirectory.org
03 04
Overview
Overview
Overview
Clivet efficient inverter full falling film water cooled screw chiller adopts the volume
ratio optimization control technology of Clivet independently-developed inverter twin
screw along with our environmentally friendly R134a refrigerant and full falling film
4 Product Structure
evaporation technology to achieve a higher partial load efficiency. Compared with IPLV comparison of traditional fixed frequency unit and Clivet inverter unit
traditional fixed-frequency screw units, this newer unit is more efficient, more stable (a 10.0
30% improvement) and has lower operating costs. Our product also employs a number
of patented technologies and operates reliably, safely and stably. It applies to projects 8.0
Microcomputer control
30% Electric control panel 7-inch color display screen Compressor
with large system air conditioning load fluctuation and longer partial load running system
The compressor screw rotor adopts a
Clivet's flexible sinking design has Providing auto-diagnosis, Easy-to-read unit status;
times (for example, in medium and large public buildings and civil buildings like hotels, 6.0 new profile, and the air supply and
made a breakthrough in the single adjustment, security protection, convenient to operate and
office buildings, hospitals, factories and shopping malls). enthalpy feature improved
plane shape, featuring a lively and remote control and other functions maintain technology that greatly enhances
4.0 futuristic look
The cooling capacity range of Clivet efficient inverter full falling film water cooled screw efficiency
chiller is 120 RT to 450 RT. It has been awarded AHRI and energy-efficient product
2.0
certifications, and made vast contributions to saving energy and reducing emissions in
Traditional fixed Clivet inverter unit
green city construction, proving to be an ideal choice for air conditioning in green frequency unit
buildings.
1 Nomenclature
W D H T -CN 120 .1 H V
Screw, Inverter
2 Operating Range
Item Unit Operating Range
Note: Normal use of the unit will be adversely affected if the above parameter exceeds the operating range.
3 Scope of Application
05 06
Features
Features
Features
Clivet's independently-developed volume ratio optimization control technology integrates the characteristic curves of a compressor, inverter and motor, and maximizes The pioneering full falling film evaporator reduces the volume of refrigerant required.
the performance and reliability of the inverter screw compressor. The maximum isentropic efficiency is 76%, far higher than other adjustment methods. Spray falling film technology allows the refrigerant to form a liquid film on the surface of the efficient heat exchange tube to implement film state evaporation
and greatly improve the heat exchange efficiency of the evaporator.
The refrigerant distributor is specially designed to avoid uneven liquid distribution and prevent local pipe dryness. (Patent No.: 201120134421.5)
Efficient heat
exchange tube
Start When the motor starts at a low speed, the slide valve Loading The motor speed increases, and the slide valve looks for the
rapidly rises to a middle position, and the unit does best Vi position. The built-in algorithm then analyzes the
not operate at the low slide valve position. operating parameters online, optimizes to adjust the slide
valve position and motor speed, and first lifts the slide valve.
Then, the motor speed matches the load accurately.
Refrigerant
liquid film
4 New Condenser
Load The motor slows, and the slide valve looks for the
Stop The motor slows and the slide valve drops to the lowest
It adopts the double-side reinforced condenser tube to optimize the tube bundle arrangement design in the condenser.
best Vi position. The built-in algorithm then position. The motor stops after its speed reaches the
reduction analyzes the operating parameters online, optimizes minimum setting value.
to adjust the position of the slide valve and motor The unique design of the built-in oil separator helps address the problem of lubricating oil separation.
speed, and first lowers the slide valve. Then the slide
valve assists in energy regulation. The product optimizes the subcooler design, improves the supercooling temperature, and reduces the pressure loss of subcooler, improving
heat exchange performance efficiency.
This product implements uniform gas transmission without any heat transmission blind spots.
2 Parallel dual compressor design
The dual-head unit is designed with the parallel system of double compressors, and the total heat exchange area is used to greatly improve the
operation efficiency when the single compressor operates. (Customization of non-parallel system accepted) Internal oil separator Internal oil separator
Filter Filter
Filter Filter
Compressor 1 Compressor 2
Cooling
water
outlet
Evaporator
Cooling
water
inlet
Condenser
Cooler
Electric control
cabinet
07 08
Stable and Reliable Accurate Capacity Adjust
1 Reliable Oil System 1 Energy Saving Principle of Inverter Adjust
Clivet's MC efficient inverter full falling film water cooled screw chiller has an oil circuit control system that adopts leading technology, The inverter screw unit regulates the cooling capacity by reducing the frequency. The COP of the partial load is better than the fixed
which ensures stable operation of the unit. frequency unit, which greatly enhances the energy efficiency.
Features
Features
Venturi
Fixed frequency screw
6%
COP(kW/kW)
Water outlet Water outlet
Inverter energy
Evaporator
Condenser
saving areas
Water inlet Water inlet
5.5%
Orifice plate
Electronic
expansion valve
Dry filter Straight ball valve Liquid outlet
of condenser
4.5%
Advanced oil control system Built-in three-stage oil separator Built-in oil separator for the
for the compressor condenser
Oil supply
This system features a differential pressure-type oil supply. All the moving parts in the compressor can stay well lubricated without an external oil pump. 4.0% Operating load (%)
Oil return
The first oil separation: The The second oil separation: The built-in high efficiency oil Double oil return system: This system adopts oil return through oil separation and Venturi injection. Oil return is 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
compressor is provided with a separator for the condenser controls the oil separation implemented through the Venturi tube injection of high pressure gas, and oil is not stored in the evaporator. An oil
three-stage oil separator to efficiency to a value above 99.99%, enabling the system heater is set in the unit. The control system preheats the lubricating oil according to the unit's status to maintain
ensure low oil content. to realize normal oil return under both partial load and full optimal viscosity, optimizing the lubrication function. The external oil filter can be replaced easily. Note: Let's use 7/32°C operating conditions as an example.
load,ensuring reliable and stable operation of the system
and increasing the unit operating range.
09 10
Environmentally Friendly Intelligent Control
1 Environmental protection refrigerant
R134a environmentally friendly refrigerant achieves high cooling efficiency,without destroying the ozone layer. The refrigerant
complies with the Montreal Protocol.
Full falling film evaporation technology greatly improves heat exchange efficiency and reduces the refrigerant charge at the same time,more
environmentally friendly.
Features
Features
Protection of the
0%
Temperature change in feed-forward controls
ozone layer
0
Preventing global
warming
R22 refrigerant unit R134a refrigerant unit Intelligent load control: Real-time load changes are predicted according to historical data, and the real-time load is prospectively revised to
Safe and intelligent unit control: The system monitors the trends of change in the unit's parameters and adjusts the operating status of the unit
Intelligent failure response: When the unit fails, in addition to executing the corresponding protective measures, the fault parameters are
Muffling
structure Communication interface: Communication protocol:
design
M20 RS485 ModBus- RTU
Compressor foot
Protection measures: more than
Shock-absorbing cushion 20 protection measures help protect
the power supply, compressor,
pressure, and temperature.
Base
Shock-absorbing cushion installation diagram Built-in discharge muffler design for compressor
11 12
Intelligent
Management Specifications
Clivet CPC comprises of an equipment layer, control layer and management layer. The equipment layer includes mainly the basic air WDHT-CN***HV SCWE 120.1 150.1 180.1 200.1 230.1 270.2 300.2 330.2 360.2 390.2 430.2 450.2
conditioning equipment such as chillers, pumps, fans, valve actuators, sensors and other auxiliary equipment in the air conditioning
RT 116.9 150.7 223.1 264.1 301.8 326.7 354.0 389.7 426.0 444.0
179.2 192.4
room. The control layer is built on PLC/DDC controllers, and its main purpose is the acquisition and analysis of system operating data. Cooling capacity
kW 411.1 530.0 630.2 676.7 784.6 928.8 1061 1149 1245 1371 1498 1562
An excellent control strategy is deployed which can reasonably control the equipment layer that includes pumps, fans, and chillers,
Power input kW
and thus simplifies operation management, improves system reliability and reduces energy consumption. In addition, an interface for 76.41 91.06 112.8 120.8 140.3 164.6 181.3 203.5 226.8 241.7 260.0 279.4
BAS communications is reserved in the control layer for remote monitoring and control of the system. The management layer is Cooling COP W/W 5.38 5.819 5.586 5.601 5.592 5.642 5.854 5.645 5.488 5.670 5.761 5.588
equipped with a computer monitoring platform and system management and control software for integrated management and Cooling IPLV W/W 8.56 9.163 8.556 8.798 8.630 8.944 8.915 8.907 9.110 9.153 9.074
8.919
monitoring of the group control system. Level 1 Level 1 Level 1 Level 1 Level 1 Level 1 Level 1 Level 1
Energy efficiency grade Level 1 Level 1 Level 1 Level 1
Qty 1 1 1 1 1 2 2 2 2 2 2 2
Web client Clivet CPC Workstation Web client
Intelligent Management
Name / R134a
Refrigerant
Charge quantity kg 130 160 175 180 210 280 300 300 310 330 335 340
Power 380V-3N-50Hz
Rated electrical current A 157.2 193.1 211.4 223.1 311.6 347.7 366.1 411.3 435.9 472.4
128.4 282.9
Master group Maximum running current A 167.1 207.0 254.3 278.4 308.6 370.0 409.9 457.2 481.3 539.3 569.6 617.3
control panel Terminal group
Startup current A < 167.1 < 207.0 < 254.3 < 278.4 < 308.6 < 370.0 <409.9 <457.2 <481.3 <539.3 < 617.3
control panel <569.6
Water flow m /h
3
63.72 82.15 97.67 104.9 121.6 143.9 164.5 178.1 193.0 212.4 232.2 242.0
Network fan Water-side
Evaporator kPa
coil thermostat pressure drop 58.9 58.9 60.5 60.2 61.2 55.9 54.4 56.1 55.1 55.1 55.3 55.7
3rd-party
Specifications
Connection
mm DN150 DN150 DN150 DN150 DN150 DN200 DN200 DN200 DN200 DN200 DN200 DN200
equipment DDC controller pipe diameter
for terminals Water flow m3/h 79.67 102.7 122.1 131.1 152.0 179.9 205.7 241.2 290.3 302.5
222.6 265.5
Condenser Water-side
3rd-party kPa 53.1 56.3 54.1 53.6 53.5 63.8 67.2 63.6 63.1 66.8 66.1 65.8
3rd-party pressure drop
instrument instrument Connection mm DN150 DN150 DN200 DN200 DN200 DN200 DN200 DN200 DN200 DN200 DN200 DN200
pipe diameter
Clivet chillers Length mm 3500 3500 3500 3500 3500 4600 4600 4600 4600 4650 4650 4650
Dimensions Width mm 1600 1600 1800 1800 1800 1850 1850 1800 1800 1900 1900 1900
Control at equipment room Monitoring at terminals
Height mm 2291 2291 2391 2391 2391 2438 2288 2288 2288 2343 2393 2393
Shipping weight kg 2763 3289 3595 3629 3802 5562 5914 5989 6060 6431 6622 6665
Operating weight kg 2943 3501 3870 3919 6435 6544 6655 7100 7340 7406
4122 6036
◎ System operation schedule setting ◎ Automatic switching to a standby device if a device fails
13 14
Dimensions
External view and related dimensions of the single compressor unit: Outside View and Related Dimensions of the Dual Compressor Unit:
WDHT-CN120.1HV-WDHT-CN230.1HV WDHT-CN270.1HV-WDHT-CN450.1HV
Model A B C D E F G H J Model A B C D E F G H J
WDHT-CN120.1HV 3500 1600 2291 2850 1500 411 671 411 671 WDHT-CN270.2HV 4600 1800 2438 3860 1700 618 793 618 793
WDHT-CN150.1HV 3500 1600 2291 2850 1500 411 671 411 671 WDHT-CN300.2HV 4600 1800 2288 3860 1700 618 793 618 793
Dimensions
Dimensions
WDHT-CN180.1HV 3500 1800 2391 2850 1700 436 696 436 696 WDHT-CN330.2HVWD 4600 1800 2288 3860 1700 618 793 618 793
WDHT-CN200.1HV 3500 1800 2391 2850 1700 436 696 436 696 HT-CN360.2HV 4600 1800 2288 3860 1700 618 793 618 793
WDHT-CN230.1HV 3500 1800 2391 2850 1700 436 696 436 696 WDHT-CN390.2HV 4650 1900 2343 3860 1800 468 818 468 818
WDHT-CN430.2HV 4650 1900 2393 3860 1800 468 818 468 818
WDHT-CN450.2HV 4650 1900 2393 3860 1800 468 818 468 818
15 16
Installation
Installation
Power inlet line phase sequence of
the customer Powe
r line inle
t loca
tion o
f the
custo
mer
17 18
Reference
Projects
Country: China
City: Guangzhou
Outdoor Unit: Water-cooled screw chiller
Indoor Unit: AHU
Total capacity: 3,650 kW
Reference Projects
Reference Projects
19 20
Midea Headquarter Building
Country: China
City: Shunde
Total Capacity: 3,700 RT
Outdoor Unit: Centrifugal chiller & Water-cooled screw chiller
& Air-cooled scroll chiller & DC Inverter VRF
Indoor Unit: AHU & Cassette & Wall Mounted & Duct
Reference Projects
Reference Projects
Control System: BMS
Completion Year: 2010
21 22
The 27th Southeast Asian Games Stadium
Country: Myanmar
City: Nay Pyi Taw
Total Capacity: 4100RT
Outdoor Unit: Water-cooled screw chiller (Heat Recovery)
Indoor Unit: MAHU
Completion Year: 2012
Total Floor Area: 40,000 m²
Reference Projects
Reference Projects
23 24
Beijing Airport T3 Terminal Hilton Hotel in Foshan (Five Star)
Country: China Country: China
City: Beijing City: Foshan
Total Capacity: 9556RT Total Capacity: 3,700 RT
Outdoor Unit: Centrifugal Chiller & Water-cooled screw chiller Outdoor Unit: Centrifugal chiller & Water-cooled screw chiller
Indoor Unit: FCU Indoor Unit: AHU & FCU
Control System: BMS Control System: BMS
Completion Year: 2007 Completion Year: 2013
Total Floor Area: 900,000 m² Total Floor Area: 90,000 m²
Reference Projects
Reference Projects
25 26
The Prime Minister Office Building
Country: Tajikistan
City: Dushanbe
Total Capacity: 2880kW
Outdoor Unit: Water-cooled screw chiller
Indoor Unit: Cassette & Duct FCU
Control System: Wired Control & Remote Control
Completion Year: 2015
Reference Projects
Indoor Unit: Cassette & Floor standing FCU
Control System: Wired Control & Remote Control
Completion Year: 2012
27 28