You are on page 1of 5

The sun is on your side.

Residential and commercial photovoltaic solutions.


Self-consumption has the right of way
The easiest way to cut your electricity bill is to consume the solar power you have generated. The blueplanet 5.0 TL3 to
10.0 TL3 are factory-fitted with Priwatt for this very purpose. Using this function, solar power can be used specifically to run
household appliances. The PV plant can be optionally extended to include the blueplanet gridsave eco TR1 storage system.

Solar modules

(Photo: shutterstock)
Inverter with
Priwatt function

Production meter
NEW blueplanet Battery
8.6 TL3 and 10.0 TL3

The short-cut to high yields.


Solar inverters with AC outputs of 5 to 10 kVA. Consumer
(e.g. hot water tank)

blueplanet gridsave eco 5.0 TR1


The blueplanet 5.0 TL3 to 10.0 TL3 are transformerless, Their compact housing is protection rating IP65 classified so
Load Bidirectional meter
3-phase inverters with AC outputs of 5.0 kVA / 6.5 kVA / that the inverters stand up to the toughest conditions, even
disconnecting Manual
7.5 kVA / 8.6 kVA / 9.0 kVA / 10.0 kVA. They are the ideal in outdoor applications. Nevertheless, with a weight of only relay bypass switch
devices for running small, private solar power systems in a 30 kg, they are easy to carry. Communication
DC line
smooth and efficient manner. AC line
The AC and DC peripherals can be hooked up quickly using
Each inverter has 2 MPP trackers. This enables you to get to plug connectors. The tried-and-tested display allows you to
grips with any conceivable design of a modular PV generator. conveniently adjust the settings on the inverter.
The broad input voltage range of 200 V to 800 V also opens Power control with the Digital Inputs Extension Module
up multiple string configurations.
The extension module is our cost-effective solution for regulating the power output of the blueplanet 5.0 TL3 to 10.0 TL3 via re-
mote control, if feed-in management is necessary. To this end, the optional module directly implements the grid operator’s per-
Flexible Communicative formance specifications via a ripple control receiver. In this way, the PV system can assist in correcting faults in the power grid.
 2 MPP trackers, symmetrical or asymmetrical loading  Quick start-up using the display saves time and cuts costs
 Wide MPP range D ata logger with web server
 Self-consumption with Priwatt, storage system (optional) N umerous standard communication interfaces  4 digital inputs
 Implementation of ripple control signals
Simple  Remote-controlled power adjustment instead of fixed
 Light and compact power limitation
 IP65  Lack of external data loggers ensures cost-saving solution
 AC and DC cabling using plug connectors

2 3
AC cost reduction
In Germany and Austria low voltage guidelines are already in force; a similar policy is expected for Switzerland. They stip-
ulate the deployment of external circuit-breakers circuit-breakers or substations from 30 kVA upwards. That can easily run
into four-figure sums for material, installation and operation. That is however not the case with the KACO new energy
Powador and blueplanet string inverters: circuit-breakers are built into all devices as standard! You only need the Pow-
ador-protect which directly controls these internal circuit-breakers. For operators that means simple, no-risk calculations,
and no hidden AC costs. On top of that, the Powador-protect evaluates the signals from ripple control receivers and trans-
mits these to up to 31 inverters. The Powador-protect itself can be quickly installed, is easy to handle and is therefore the
most economic solution on the market.

 Grid and system protection as per VDE-AR-N 4105

(Photo: TRITEC)
and ÖNORM
 Individual voltage and frequency adjustment
 Option to actuate the integrated inverter circuit-breakers
 No external circuit-breakers required, additional AC-side
material and labour costs no longer necessary
 Also as a supplement to Powador-proLOG
 The amount of cabling in the meter cabinet and the
sub-distribution can be kept to a minimum
 A ripple control receiver connection is integrated
NEW
blueplanet 20.0 TL3  The system can be easily incorporated into the feed-in
management without additional costs

Successful long-term investments for your business. Ripple control Powador-protect Inverter
Solar inverters with AC outputs of 10 to 20 kVA. receiver
POWADOR-protect

The Powador 12.0 TL3 to 20.0 TL3 are transformerless, The inverters switch to the grid from 250 V. When in opera-
3-phase inverters with AC outputs of 10.0 kVA / 12.5 kVA / tion, they still feed in at 200 V - for the highest possible solar
15.0 kVA / 17.0 kVA. The new blueplanet 20.0 TL3 INT is a yields all year round.
20.0 kVA device. These devices can be used to install extreme-
3 ~/N/PE
ly flexible, decentralized, commercial solar power systems up The units are fitted with a data logger and web server to mon-
Signal for power control
to a medium size. itor the system, a display for showing operating data and a Evaluation of ripple control signals
USB port for running updates or reading out log data. AC grid
The inverters have 2 separate MPP trackers which allow you to
meet all typical requirements of complex designs - such as the
full configuration of an east / west-facing roof.

Flexible system monitoring.


Efficient Communicative
 Up to 98.0% efficiency  Multilingual menu, graphical display Easy system monitoring can be achieved without additional devices and costs. Our inverters in the Powador TL3 range and
 2 MPP trackers, symmetrical or asymmetrical loading  Data logger with web server all of the new blueplanet inverters come equipped with data logger and web server, and offer all current interfaces.
 Wide MPP range  Quick start-up using the display saves time and cuts costs
Would you like to combine the built-in advantages with the comfort of a professional online monitoring portal? Simply keep
Simple track of your PV array using our Powador-web! You can also connect the data logger of your choice, regardless of brand,
 Preconfigured country settings to our inverters. In that way, your PV array can be extended to include additional accessories such as sensors for collecting
 Compact design environmental data, or it can be displayed on the monitoring portals of alternative providers.
 DC connection via solar connectors
You can get more information about the available products and prices from your authorised KACO Distributor.

4 5
Reference projects with system solutions by
KACO new energy.

(Photo: istock)
Collombey / 1.31 MWp / Powador 60.0 TL3 Bolzano / 500 kWp / Powador 60.0 TL3
(Photo: TRITEC) (Photo: Luna-Gruppe)

NEW
blueplanet 50.0 TL3

Rise to the occasion.


Inverters for large commercial and industrial solar power plants.

KACO new energy also offers a high level of expertise in large- purposes, there is a wide range of inverters to choose from,
scale commercial and industrial projects which count on the with AC outputs between 25 and 50 kVA. The inverters are
benefits of a decentralized design - regardless of whether it’s also available in numerous versions with features which build
a roof-mounted system or an open-area installation. For these on each other, allowing you to work to specific requirements.

Salzburg / 500 kWp / Powador 18.0 TL3 Malta / 36 kWp / Powador 20.0 TL3
More than 2 GW of
Powador 30.0 TL3 - 60.0 TL3 inverter power delivered
(Photo: Luna-Gruppe) (Photo: Elektro Neunegger)

These tried-and-tested inverters are ideal for photovoltaic  Up to 98 % efficiency


systems whose photovoltaic generators are unevenly con- 3 MPP trackers, symmetrical or asymmetrical loading
structed or are partly exposed to shade. These include fac-  Multilingual menu
tory roofs which are, for example, interspersed with chim-  Cost-saving DC input configurations available
neys, skylights or vent shafts, or solar parks on hilly ground  Data logger with web server
or open areas surrounded by trees.

blueplanet 50.0 TL3 INT  98.5% efficiency


 Wide MPP range for longer strings
The blueplanet 50.0 TL3 INT packs the output of 50 kVA  Up to 40% inverter oversizing possible
into an extremely compact, wall-mounted design with IP65  Input voltage of up to 1,100 V for flexibility and safety in the
for outdoor use. The inverter is available in three versions DC design
for individual customisation with DC switch, string protec-  Large cross-sections possible for copper and aluminium cables
tion and surge protection type I + II.  Adjustable cos phi from 0.3 ind. to 0.3 cap. for special reactive Hall in Tirol / 250 kWp / Powador 60.0 TL3
power requirements (Photo: Sonnergy GmbH)

6 7
Birds of a feather.

EN 5001008_05_170201
KACO new energy services.

5 - 7 year guarantee

5-7

Manufacturer
expertise

Full Service

Optional extended
warranty

Comprehensive
service network

Distributor details

www.kaco-newenergy.com

You might also like