2216/2116
Installation
Verification
Chapter 4
Verifying RBS Installations at Site
Ensure that all cable connections at the front of the cabinet are correctly connected
It can take up to 10 minutes before all units in the cabinet are in operation.
2. In the Available monitors box, select External Alarm Status, and click → to add Alarm Inlets
In the Monitors to start box.
3. Click Start Monitor.
4. Remove the external alarm covers.
5. Ensure that the eexternal alarm cable on the RBS side of each Overvoltage Protection (OVP) module,
and the wires of the external alarm cable are properly connected.
6. Trigger the alarm by either closing or breaking it at the OVP module or by triggering the alarm detector
7. Check that the alarm is correctly recognized
8. Release the trigger on the alarm and check that the alarm disappears.
When a faulty unit is returned, it must always be accompanied by a repair delivery note. When the repair
Delivery note has been completed, it must be attached to the faulty unit before sending it to repair.