Scene name: Safety Subject: Safety belt and cap are extremely needed

Right Wrong

Notes:
Safety Helmet and shoes are needed for the working on the site.
Full body harness and lanyards and safety shoes and mechanical gloves also helmet are needed
for working on the tower or poles.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 4


Scene name: Safety Subject: Safety Driving

Right Wrong

Notes:
Wear seat belts when driving;
Never use hand held phone when driving;

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 5


Rigger Connect his body harness
Scene name: Safety Subject:
snap hook to the Sit connection D ring

Right Wrong

Notes:Right way direct connect the chest part to the sit part in the harness body
hole behind the sit D ring to ensure both EN 361 and EN 813 are operated

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 6


rigger pass double lanyard under his arm
Scene name: Safety Subject:
during positioning

Right Wrong

Notes:Right way double lanyard should pass above shoulders to ensure


the shock absorber will be probably response to any fall and safe the
Rigger from hit his body to tower

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 7


Scene name: Safety Subject: Electrical Safety

Right Wrong

Notes:
Can not use damage power cable ;
No electrical work without tools protective, all tools used for the electrical work should be
electrically isolated;

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 8


Scene name: Safety Subject: Banding and lifting the equipment safety

Right Wrong

Notes:
Lifting the RRU should be band lifting point and traction point ;
Lifting the antenna should be band lifting point and traction point;

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 9


Scene name: Safety Subject: Safety starts with good Housekeeping

Right Wrong

Notes:
Tools should be placed neatly and properly;
Keep the environment of the site neat and clean. Don’t leave any boxes, cables, bottles…

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 10


Contents
 Safety chapter
 Ground system chapter
 Waterproof chapter
 Laying cable chapter
 Installation equipment chapter
 Label chapter
 ISDP operation
 Picture of PAT
 Picture of Dismantle report
 Other

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 11


Scene name: OT terminal Subject: OT terminal insulation

Right Wrong

Notes:
The heat shrink tube should cover the copper wire.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 12


Scene name: RRU Subject: Grounding the RRU

Right Wrong

Notes:
Grounding on RRU should be done ;RRU earth terminal is fixed tightening; Earth terminal on RRU
should be screwed tightly ;

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 13


Remove the oil paint of the tower for
Scene name: Grounding Subject:
grounding point

Right Wrong

Notes:
Oil paint of tower is not removed on earth grounding point. electric ability surge protection will
be decreased.
Paint should be removed before connecting the ground cable, and isolation paint should cover
the scratched area after that.
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 14
Paint the oil paint of the tower for
Scene name: Grounding Subject: grounding point again after removed
painting

Right Wrong

Notes:
Oil paint of tower should be paint again after paint removed to protect the tower from corruption.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 15


Scene name: Grounding Subject: Grounding the RRU

Right Wrong

Notes:
Connect the grounding point should by screw, Grounding cable connect point paint for antirust.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 16


Scene name: Grounding Subject: Grounding the RRU

Right Wrong

Notes:
One RRU grounding cable connect one point only. And the screw must be tightly.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 17


Scene name: RRU Subject: The metal shield of RRU power cable

Right Wrong

Notes:
The metal shield of RRU power cable should be cut and grounding on clip inside RRU cabling
cavity. The metal shield can not be cut too long and it go outside the cabling cavity.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 18


Page 18
RRU power The RRU power cables grounding for
Scene name: Subject:
cable indoor site

Right Wrong

Notes:
(Indoor site)The RRU power cables should be grounded by the grounding clip on the grounding
bar before routed into the feeder window. The grounding point should waterproof.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 19


RRU power The RRU power cables grounding for
Scene name: Subject:
cable outdoor site

Right Wrong

Notes:
(Outdoor site)The RRU power cables should be grounded by the grounding clip in the outdoor
cabinet. Once grounding only.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 20


Scene name: DCDU Subject: Ground the DCDU

Right Wrong

Notes:
Ground the DCDU on the cabinet grounding bar. ( Use 6mm grounding cable. )

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 21


Scene name: BBU Subject: BBU grounding

Right Wrong

Notes:
BBU grounding cable should connect to right side

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 22


Arrester
Scene name:
Installation
Subject: GPS SPD grounding

Right Wrong

Notes:
The GPS SPD must be grounded. And the “Surge” port to GPS, “Protect” port to BBU.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 23


Scene name: BTS Subject: Grounding the BTS3900L

Right Wrong

Notes:
The grounding cable connectors must by OT terminal.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 24


Scene name: Grounding Subject: No grounding bar fixed in the shelter.

Right Wrong

Notes:
Must installing the grounding bar in the shelter.(Please report if no grounding bar)

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 25


Scene name: Grounding Subject: Grounding the BTS3900

Right Wrong

Notes:
BTS grounding should be fixed correctly. BBU/DCDU/IDU/UFLP should fix the grounding cable to
the BTS grounding bar.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 26


Grounding
Scene name:
cable
Subject: The cable running standard

Right Wrong

Notes:
The PGND cable is the shorter the better. can not has remaining and roll up.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 27


Scene name: ODU Subject: Grounding for ODU

Prepare the grounding cable Connect the grounding cable

Notes:
The ODU should grounded by the specified grounding cable.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 28


The IF cable grounding for indoor site(2
Scene name: IF cable Subject:
points)

Point 1 Point 2

Notes:
(Indoor site)The IF cable should grounding 2 points by the clip. The grounding points
should waterproof.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 29


The IF cable grounding for outdoor site(2
Scene name: IF cable Subject:
points)

Point 1 Point 2

Notes:
(Outdoor site)The IF cable should grounding 2 points by the clip. The grounding points
should waterproof.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 30


Contents
 Safety chapter
 Ground system chapter
 Waterproof chapter
 Laying cable chapter
 Installation equipment chapter
 Label chapter
 ISDP operation
 Picture of PAT
 Picture of Dismantle report
 Other

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 31


Scene name: Waterproof Subject: Waterproof standard

Waterproof procedure Waterproof graphic

Step1 Step2 Step3 Step4 2 3

Connect The The Tightly


jumpers to waterproof insulation Seal the
RRU, tape is tape is two ends of
tighten the wrapped wrapped the
connectors; spirally spirally waterproof
wrapped upwards, upwards, connector
spirally downwards, downwards, when finish
insulation and then and then wrapping 1 4
tape in one upwards upwards
layers again in three again in
layers three layers

1 3 3

Notes:
The waterproof should be 1+3+3(1 layer PVC tape + 3 layers waterproof tape + 3 layers PVC tape).

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 32


Scene name: Waterproof Subject: Waterproof feeder/jumper/IF connectors

Right Wrong

Notes:
The waterproof should be 1+3+3.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 33


Scene name: Waterproof Subject: Waterproof for connectors

Right Wrong

Notes:
The 2 ends of waterproof area should be tied with cable tie, and should be tied tight. Outdoor
cable tie cut reserve 3-5mm.(Black cable tie use for outdoor, white cable tie use for indoor)

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 34


Scene name: Waterproof Subject: Waterproof for outdoor grounding

Right Wrong

Notes:
The waterproof for power/IF cable should be following 1+3+3 rule . The operation of waterproof
must be regular.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 35


Scene name: Waterproof Subject: Waterproof for outdoor cabinet

Right Wrong

Notes:
The spare hole should be filled with mud for waterproof.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 36


Scene name: Waterproof Subject: Waterproof for feeder window

Right Wrong

Notes:
The spare hole should be filled with mud for waterproof.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 37


Page 37
Contents
 Safety chapter
 Ground system chapter
 Waterproof chapter
 Laying cable chapter
 Installation equipment chapter
 Label chapter
 ISDP operation
 Picture of PAT
 Picture of Dismantle report
 Other

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 38


Scene name: Jumper cable Subject: The cable running standard

Right Wrong

Notes:
The jumper cables should fixed by cable tie. The electronical tilt should covered.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 39


Scene name: CPRI/IF cable Subject: Put the remaining cables

Right Wrong

Notes:
The remaining CPRI cable should be put behind the RRUs. The IF cable reserved 3-5m put near
the ODU.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 40


Power/IF
Scene name:
cable
Subject: The cable running standard

Right Wrong

Notes:
The RRU power cable run straightly, and fix with clip spacing distance 1-1.5M(or by the step).The
IF cable fix by cable tie spacing distance 1-1.5M(or by the step).

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 41


Power/CPRI
Scene name:
/IF Cable
Subject: The cable running standard

Right Wrong

Notes:
The power cable and signal cable need to run separately. Each 3 (power or CRPI cables) use 1
PVC, the PVC nozzle use waterproof material for protection. The IF cables no need PVC.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 42


Scene name: PVC Subject: The cable running standard

Right Wrong

Notes:
Each 3 (power or CRPI cables) use 1 PVC for protection. The IF cables no need PVC. Can’t cover
all cable ladder.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 43


Power/CPRI
Scene name:
/IF Cable
Subject: PVC pipe installtion

Right Wrong

Notes:the Power and CPRI cables should run inside PVC cable , cutting the PVC pipe is
prohibited.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 44


Scene name: PVC Subject: The cable running standard

Right Wrong

Notes:
Fix the cables by clips if there has overhead cable ladder between the tower and equipment room .

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 45


Power/Signal
Scene name:
cable
Subject: The cable running standard

Right Wrong

Notes:
The power cable and signal cable running separately, power cable left side , signal cable
right side. and laying cleanly.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 46


The cable of
Scene name:
indoor
Subject: The cable running standard

Right Wrong

Notes:
The power cable and signal cable running separately, and laying cleanly.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 47


DCDU Power Remove the shield of the power cable
Scene name: Subject:
Cable near connector

Right Wrong

Notes:
The black shield of the power cable near the power connector of DCDU should be cut and tied up.
The power cables should running by left side.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 48


Scene name: Tie Subject: The tie must be cut

Right Wrong

Notes:
All cables must be tied with white tie for indoor.The white tie must be cut no reserve.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 49


Scene name: Cable routing Subject: Power and signal cable separate

Right Wrong

Notes:
The power and signal cables should be separate. The distance more than 3-5cm.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 50


Scene name: Tie Subject: Installation standard of the tie

Right Wrong

Notes:
The outdoor black cable tire should keep a spare length after cutting(3-5MM) .

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 51


The cable of
Scene name:
indoor
Subject: The cable running standard

Right Wrong

Notes:
The cable should be arranged cleanly.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 52


Scene name: CPRI Fiber Subject: The cable running standard

Right Wrong

Notes:
The cables can not stem the free space.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 53


Scene name: Fiber Subject: The cable running standard

Right Wrong

Notes:
The fiber cables should be protection by PVC pipe.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 54


The DCDU power cable installation at DC
Scene name: Power cable Subject:
BOX side

Right Wrong

Notes:
The power cables connect should correctly, Blue for negative(--),Black for positive(+).
It should use cold terminal at DC BOX side to connect to breaker.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 55


Scene name: GPS cable Subject: The cable running

Right Wrong

Notes:
The GPS cable must be tied with black tie, and waterproof/labeling.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 56


Contents
 Safety chapter
 Ground system chapter
 Waterproof chapter
 Laying cable chapter
 Installation equipment chapter
 Label chapter
 ISDP operation
 Picture of PAT
 Picture of Dismantle report
 Other

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 57


Scene name: Bracket Subject: Bracket installation

Right Wrong

Part A
Part B

Notes:
Part A and Part B should be aligned and fix well.
The antenna bracket should match the tower structure

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 58


Scene name: Bracket Subject: Bracket installation

Right Wrong

Notes:
The ant pole bracket should match tower leg type. Such as MW/WL bracket、WL antenna support.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 59


Scene name: Bracket Subject: Bracket installation

Right Wrong

Notes:
Each side need to install two nuts and fix well. Such as MW/WL bracket、WL antenna support.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 60


Scene name: Bracket Subject: Bracket installation

Right Wrong

Notes:
Installation standard for “V” type tower member.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 61


Scene name: Bracket Subject: MW sway bar

Right Wrong

Notes:
Sway bar should try install vertically with antenna or satisfy deviation range.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 62


Scene name: Antenna Subject: Antenna preparation

Right Wrong

Notes:
Keep covered the connectors before installed.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 63


Installed the bracket assembly on the
Scene name: RRU Subject:
right direction

Right Wrong

Notes:
Follow the label on the bracket assembly carefully. And make sure the bracket assembly of the
RRU is installed on the right direction.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 64


Page 64
The RRU maintenance window must be
Scene name: RRU Subject:
closed

Right Wrong

Notes:
The RRU maintenance window should be closed after installation completed.
The RRU maintenance window should be closed tight for waterproof.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 65


Scene name: RRU Subject: Protect the unused ports

Right Wrong

Notes:
The RRU unused ports should be protected. Procedure: covered first, then by PVC tape 2-3 layers.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 66


Scene name: RRU Subject: Connecting piece

Right Wrong

Notes:
The connecting piece must connect between two RRUs.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 67


Scene name: RRU Subject: RRU door

Right Wrong

Notes:
The door of the RRU should open easily.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 68


The waterproof plugs are filled in the
Scene name: RRU Subject:
vacant troughs

Right Wrong

Notes:
The water plugs should be filled in the vacant troughs of the RRU cabling cavity.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 69


Page 69
Scene name: Power cable Subject: The power cable connect correctly

Right Wrong

Notes:
The power cables connect should correctly, Blue for negative(--),Black for positive(+).

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 70


Scene name: Power cable Subject: The RRU power cable installation

Right Wrong

Notes:
Correctly peel the power cable coat, the copper wire 17mm.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 71


Scene name: RRU Subject: Antenna bracket

Right Wrong

Notes:
The antenna bracket install direction should follow the mark.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 72


Scene name: BBU Subject: BBU should be fixed with screws.

Right Wrong

Notes:
BBU/DCDU/IDU should be fixed with 4 screws. Cable ties is forbidden to use for fixing equipment.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 73


Scene name: BBU Subject: Protect the unused ports

Right Wrong

Notes:
Protect the BBU all unused ports. Such as UBBP/UMPT etc.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 74


Scene name: IDU Subject: The IF board installation

Right Wrong

Notes:
Protect the IDU all unused slots by the covers, all dummy boards should be installed

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 75


Scene name: IF cable Subject: The IF cable installation

Right Wrong

Notes:
Making the IF cable connector correctly by the installation guide, meet the quality requirement.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 76


Scene name: IDU Subject: The IDU cables installation

Right Wrong

Notes:
The IDU cables can not stem the IF board slots.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 77


Scene name: Power cable Subject: The DCDU power cable installation

Right Wrong

Notes:
The power cables connect should correctly, Blue for negative(--),Black for positive(+).

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 78


Scene name: Power cable Subject: The RRU power cable must tight

Right Wrong

Notes:
Connecting the RRU power cable to the DCDU correctly and tight.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 79


Scene name: Water sensor Subject: The water sensor installation location

Right Wrong

Notes:
The water sensor should be put on the ground.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 80


The hole of
Scene name:
equipment
Subject: The spare hole must be filled

Right Wrong

Notes:
The spare hole should be filled with mud for waterproof .

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 81


Scene name: Clean up Subject: Clean up the site

Right Wrong

Notes:
Clean up the site outside and inside ,can not leave any rubbish on site.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 82


Scene name: BTS Subject: Cabinet installation

Right Wrong

Notes:
The BTS installation accessory should installed.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 83


Contents
 Safety chapter
 Ground system chapter
 Waterproof chapter
 Laying cable chapter
 Installation equipment chapter
 Label chapter
 ISDP operation
 Picture of PAT
 Picture of Dismantle report
 Other

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


Scene name: Color ring Subject: Color ring for CPRI/PWR cable

Regulations Sample

Notes:
RRU Power cable /CPRI cable color ring should follow the regulations.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


Scene name: Color ring Subject: Color ring for Jumper cable

Regulations Sample

Notes:
Jumper cable no need color ring. use the plastics label fix on the jumper cable 2 ends. follow the
regulations.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


Scene name: Label Subject: Labeling for outdoor(RRU&ANT)

Right Wrong

Notes:
Outdoor :The jumper/power/CPRI/PGND)use the yellow label by tie binding. follow the regulations.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 87


Scene name: Label Subject: DC power cable

Right Wrong

Notes:
Indoor : The power cables should be labeling one by one. All labeling should be printing.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 88


Scene name: CPRI Fiber Subject: The CPRI fiber should be tied.

Right Wrong

Notes:
Indoor : The signal cables should be labeling one by one. All labeling should be printing by the
paper label. Handwritten is prohibited.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 89


Scene name: Label Subject: Wireless cabinet photos

Right Wrong

Notes: Take clear picture BTS overview , and show the “ORDC” mark and the site ID

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 90


Scene name: Label Subject: Wireless antenna photos

Right Wrong

Notes: Must show clearly the mark S1 or S2 or S3 and ORDC , the frequency for each sector

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 91


Scene name: Label Subject: MW photos

Right Wrong

Near-end and far-end


Sites’ IDs ODRC
mark
& polarity
On Both ODU and
Dish

Notes: Picture must be clear; it is needed to include RRU and jumper cable
Label: Near-end and far-end Sites’ IDs ODRC mark & polarity

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 92


Antenna &
Scene name:
RUU
Subject: Label for Bolt RRU

Right Wrong

Notes:Bolt RRU label should contain 1) ORDC mark , 2) the band (2600) , 3) the sector number

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 93


Antenna &
Scene name:
RUU
Subject: Label for 3G RRU

Right Wrong

Notes:3G RRU label should contain 1) ORDC mark , 2) the band (2100) , 3) the sector number

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 94


Antenna &
Scene name:
RUU
Subject: Label for 2G RRU

Right Wrong

Notes:2G RRU label should contain 1) ORDC mark , 2) the band (900) , 3) the sector number

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 95


Labeling sample(indoor)

The Following Rules Will be adopted according to site configuration:

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 96


Contents
 Safety chapter
 Ground system chapter
 Waterproof chapter
 Laying cable chapter
 Installation equipment chapter
 Label chapter
 ISDP operation
 Picture of PAT
 Picture of Dismantle report
 Other

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 97


Scene name: ISDP Subject: Use of NA option on ISDP

Right Wrong

Notes:the Subcontractor should use the N/A option for ISDP when the item is not available , the
use of blank photo or general photo or photo of a paper with NA on it is not accepted

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 98


The uploaded photo not match the
Scene name: ISDP Subject:
sample photo

Right Wrong

Notes:the uploaded photo should match with the sample photo and consider all the check
points mentions in the KCP standard and guide

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 99


Missing GPS coordinates from the water
Scene name: ISDP Subject:
mark of the photo

Right Wrong

Notes:all photos should be taken while the team on site through ISDP , and the water mark
should confirm this issue ( GPS coordinates and distance from site )

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 100


Contents
 Safety chapter
 Ground system chapter
 Waterproof chapter
 Laying cable chapter
 Installation equipment chapter
 Label chapter
 ISDP operation
 Picture of PAT
 Picture of Dismantle report
 Other

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 101


Scene name: WL PAT Subject: Mark on RRU

Right Wrong

Notes:
The mark on RRU should include: ORDC, Frequency, Site ID and Sector

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 102


Page 102
Scene name: WL PAT Subject: Antenna Picture

Right Wrong

Notes:Three part is needed for antenna picture: Antenna, RRU and the jumper cable connected
from Antenna to RRU;

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 103


Page 103
Scene name: PAT Subject: RRU Picture

Right Wrong

Notes: Picture must be clear; it is needed to include RRU and jumper cable

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 104


Page 104
Contents
 Safety chapter
 Ground system chapter
 Waterproof chapter
 Laying cable chapter
 Installation equipment chapter
 Label chapter
 ISDP operation
 Picture of PAT
 Picture of Dismantle report
 Other

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 105


Dismantle
Scene name:
Report
Subject: Before dismantle of tower

Right Wrong

Notes:1.Marked the MW& WL antenna dismantled;


2.The picture should take a little far from tower and must be clear

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 106


Dismantle Picture of the voltage measurement on
Scene name: Subject:
Report the "ODU"

Right Wrong

Notes:
Picture should show the red cable and black cable connected with ODU;

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 107


Dismantle
Scene name:
Report
Subject: After dismantle of tower

Right Wrong

Notes:1.Marked the free pole already dismantled;


2.The picture should take a little far from tower and must be clear

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 108


Dismantle
Scene name:
Report
Subject: Cabinet location ''after dismantle'

Right Wrong

Notes:
Far overiew picture

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 109


Dismantle The packed material ''after
Scene name: Subject:
Report dismantle''
Right Wrong

Notes:
Put all the material on the ground and then take picture

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 110


Dismantle
Scene name:
Report
Subject: Picture of the Site before leaving

Right Wrong

Notes:
Show the site is clean

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 111


Page 111
Contents
 Safety chapter
 Ground system chapter
 Waterproof chapter
 Laying cable chapter
 Installation equipment chapter
 Label chapter
 ISDP operation
 Picture of PAT
 Picture of Dismantle report
 Other

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 112


Colored Tape Design

The Following Rules Will be adopted according to site configuration:

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 113


DC Breaker Distribution Design

The Following Rules Will be adopted according to site configuration:

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 114


DC Breaker Distribution Design
Scenario1:
The Old DCDU is already powering the old 2100 RRUs. A New DCDU will be added for
the new RRUs.

Scenario2:
A New DCDU will be added for the new RRUs.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 115


DC Breaker Distribution Design
Scenario3:
2 New DCDUs will be added for the new RRUs.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 116


DC Breaker Distribution Design
Scenario4:
New Cabinet will be installed. New Cabinet DCDU will be used.

Scenario 5:
The Old DCDU will be dismantled and installed on the new cabinet to power on only the
2100 RRUs. The New Cabinet DCDU will be used for new RRUs.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 117


DC Breaker Distribution Design
Scenario 6:
new Cabinet will be installed and a new DCDU will be added.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 118


DC Breaker Distribution Design
Scenario7:
New Cabinet will be installed and 15 RRUs will be on site: 3 New DCDUs Needed.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 119


WL antenna install preparation
 Install antenna according to designed height, azimuth, down tilt (mechanical tilt and
electrical
The tilt)
Following Rules Will be adopted according to site configuration:

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 120


MW antenna install preparation
Install antenna according to designed height, azimuth, vertical degree and ODU/antenna
polarization, high site or low site. Be noted the frequency of ODU and antenna must be
The Following Rules Will be adopted according to site configuration:
same. two sites antenna must be visible. You can change the higher position if there has
the LOS issue.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 121


BTS Main Boards Design

The Following Rules Will be adopted according to site configuration:

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 122


BTS Main Boards Design

The Following Rules Will be adopted according to site configuration:

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 123


BTS Main Boards Design

The Following Rules Will be adopted according to site configuration:

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 124


BTS Main Boards Design

The Following Rules Will be adopted according to site configuration:

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 125


BTS Main Boards Design

The Following Rules Will be adopted according to site configuration:

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 126


BTS Main Boards Design

The Following Rules Will be adopted according to site configuration:

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 127


BTS Main Boards Design

The Following Rules Will be adopted according to site configuration:

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 128


Wireless Solution rules : BBU/CPRI/RRU Connection

The Following Rules Will be adopted according to site configuration:

GTMUb

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 129


Wireless Solution rules : BBU/CPRI/RRU Connection

The Following Rules Will be adopted according to site configuration:

UBBPd6

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 130


Wireless Solution rules : BBU/CPRI/RRU Connection

The Following Rules Will be adopted according to site configuration:

UBBPd6

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 131


Wireless Solution rules : BBU/CPRI/RRU Connection

The Following Rules Will be adopted according to site configuration:

UBBPd4

UBBPd6

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 132


Wireless Solution rules : BBU/CPRI/RRU Connection

The Following Rules Will be adopted according to site configuration:

UBBPd6

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 133


Wireless Solution rules : RRU/Antennas Connection

The Following Rules Will be adopted according to site configuration:

RRU 3959 900M

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 134


Wireless Solution rules : RRU/Antennas Connection

The Following Rules Will be adopted according to site configuration:

RRU 3959 900M RRU 3953W

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 135


Wireless Solution rules : RRU/Antennas Connection

The Following Rules Will be adopted according to site configuration:

RRU 3959 900M RRU 3953W RRU 3959 2100M

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 136


Wireless Solution rules : RRU/Antennas Connection

The Following Rules Will be adopted according to site configuration:

3959 2100M 3953W 3953W 3959 900M

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 137