a. Use a soft nylon brush to loosen any accumulation of corrosion from the battery or terminals.
b. It is important to keep the battery dry and clean. This will contribute to top performance, maximum
service life and non-contamination of cell during topping off.
Check if the battery does not have loose posts, and the case is not cracked, bulging, or
showing signs of leaking fluid.
Check if the battery surface is free of dirt and moisture.
Check if the battery connections are clean and corrosion free. This includes the frame
and body ground connections and connections at the starter motor, starter solenoid and alternator.
Check if the battery cables have no frayed wires and the insulation is intact.
Check if the battery cables are flexible and bend freely. Popping or crackling sounds
while bending the cables indicate corrosion. Replace the cables.
Check the electrolyte solution if the battery has access. Add enough distilled water to
maintain the electrolyte level just below the filler tube.
Check that the battery is properly secured and the mounting hardware is not too tight.
Always check if the status of the led light in FSCP is in “AC NORMAL”
Always check the pressure gauge of all gaseous agent, all reading must not go below 331.2 psi (left most
of the green in pressure gauge)
-Monitored the return temperatures of precision air conditioning units (PACU), %Load of uninterrupted
power supplies (UPS), and temperatures for Cold Aisles and Hot Aisles in the National Government Data
Center 1 (NGDC 1)
-Drafted guidelines for Inspection and maintenance procedure of Fire Suppression System
1. Check all initiating devices and verify time delays for system discharge. Advance
discharge of gaseous agents can be very critical; this will cause death for
persons who can’t go out of the area before the gaseous agent will be released.
2. Ensure releasing device activates properly.
3. Verify abort device and manual release functionality.
4. Check weight and/or pressure of agent containers.
5. Verify the orientation of all discharge, pipe fittings and nozzles.
6. Perform enclosure integrity test.
7. Check batteries and signal.
8. Verify as-built drawing and flow calculations.
Checklist Item #9: Overloading Electrical Sockets & Using Extension Cords Correctly
Related to overcrowding of your facility, overloading any electrical sockets is a clear fire
code violation. You may not plug too many items into a single socket, by using multiple
power strips in the same location or improper multi-plug adapters. Plugging two or more
extension cords together to extend the reach of the power in your facility, will also be
cited during a fire marshal's inspection. It is prohibited to use extension cords in lieu of
permanent wiring.