REED SWITCH ORD211

ORD211
General Purpose Ultraminiature (Low-level Load 24 V Max.)

GENERAL DESCRIPTION

The ORD211 is a small single-contact reed switch designed for general control of low-level loads
less than 24 V. The contacts are sealed within the glass tube with inert gas to maintain contact
reliability.

Features

(1) Reed contacts are hermetically sealed within a glass tube with inert gas and do not receive any
influence from the external atmospheric environment.

(2) Quick response

(3) The structure comprises an operating system and electrical circuits coaxially. Reed switches
are suited to applications in radio frequency.

(4) Reed switches are compact and light weight.

(5) Superior corrosion resistance and wear resistance of the contacts assures stable switching
operation and long life.

(6) With a permanent magnet installed, reed switches economically and easily become proximity
switches.

External Dimensions (Unit:mm)

f0.4 MAX f2.0

MAX 10.0

35.7 ±0.3

APPLICATIONS OF REED SWITCHES

1. Automotive electronic devices

2. Control equipment

3. Communication equipment

4. Measurement equipment

5. Household appliances
ORD211

ELECTRICAL CHARACTERISTICS

Rated Value
Parameter Symbol Condition Unit
Min. Typ. Max.
Pull-in Value PI — 10 — 40 AT
Drop-out Value DO — 5 — — AT
Contact Resistance CR — — — 100 mW
Breakdown Voltage — — 150 — — VDC
Insulation Resistance — — 109 — — W
Electrostatic Capacitance — — — — 0.2 pF
Contact Rating — — — — 1.0 VA
DC
Maximum Switching Voltage — — — — 24 AC V
Maximum Switching Current — — — — 0.1 A
Maximum Carry Current — — — — 0.3 A

(1) Drop-out vs. Pull-in (2) Contact resistance

(Measurement length; 22 mm)


99.9
AT
50 99

95
40
Cumulative frequency percent

90
80
70
30
Drop-out

60
50
40
30
20 20
10
5
10
1

0 0.1
10 20 30 40 50 AT 40 60 80 100 mW
Pull-in Contact resistance
ORD211

(3) Breakdown voltage (4) Insulation resistance

(DC 100 V)
99.9

DC : V 99
400
95
Breakdown voltage

Cumulative frequency percent


90
300
80
70
60
200 50
40
30
20
100
10
5

0 1
10 20 30 40 50 AT
Pull-in 0.1
10 10 10 11 10 12 10 13 10 14 W

Insulation resistance

(5) Electrostatic capacitance

(1 MHz)

pF
0.4
Electrostatic capacitance

0.3

0.2

0.1

0
10 20 30 40 50 AT
Pull-in
ORD211

OPERATING CHARACTERISTICS

Rated Value
Parameter Unit
Min. Typ. Max.
Operate Time — — 0.3 ms
Bounce Time — — 0.3 ms
Release Time — — 0.05 ms
Resonant Frequency 7000 7500 8000 Hz
Maximum Operating Frequency — — 500 Hz

(1) Operate time (2) Bounce time

(25 Hz : 100 AT energized) (25 Hz : 100 AT energized)


99.9

99
ms
0.5 Cumulative frequency percent
95

90
0.4 80
70
60
Operate time

50
0.3 40
30
20
0.2 10
5

1
0.1
0.1
0 0.1 0.2 0.3 0.4 ms
0
10 20 30 40 50 AT Bounce time
Pull-in

(3) Release time (4) Resonant frequency

(25 Hz : 100 AT energized)


99.9

ms 99
15
95
Cumulative frequency percent

90
10
Release time

80
70
60
5 50
40
30
20
0 10
10 20 30 40 50 AT
5
Drop-out
1

0.1
7000 7500 8000 Hz

Resonant frequency
ORD211

MECHANICAL CHARACTERISTICS
(1) Lead tensile test (static load) (2) Lead tensile strength
(2.27 kg - 10 sec) 99.9
AT
60 99

95

50

Cumulative frequency percent


90
80
70
40
Pull-in and Drop-out

60
50
40
30
30 20

PI 10
5
20
1
DO
0.1
10
0 2 4 6 8 10 kg
Breaking load
0

mW
80
Contact resistance

CR
60

40

Before test After test

ENVIRONMENTAL CHARACTERISTICS
(1) Temperature characteristics

CR
40

30

20 DO
Rate of change (percent)

PI
10

–10

–20

–30

–40 –20 0 20 40 60 80 100 120


Temperature °C
ORD211

(2) Temperature cycle (3) Temperature and humidity cycle

(–55°C to 125°C) (–10°C to 65°C


80% to 98% )
AT AT
60 60

50 50

40
Pull-in and Drop-out

40

Pull-in and Drop-out


30 30
PI PI

20 20
DO DO
10 10

0 0

mW mW
80 80
Contact resistance

Contact resistance

CR CR
60 60

40 40

Before test After test Before test After test

(4) High temperature storage test (5) Low temperature storage test
(125°C - 500 H) ( –40 °C - 500 H)
AT AT
60 60

50 50

40
Pull-in and Drop-out

40
Pull-in and Drop-out

30 30
PI PI

20 20
DO DO
10 10

0 0

mW mW
80
Contact resistance

80
Contact resistance

CR CR
60 60

40 40

Before test After test Before test After test


ORD211

(6) Shock test

(open Æ close)
(30 G - 11 ms)
AT
G
60
1500

50

40
Pull-in and Drop-out

1000
30

Acceleration
PI

20
DO Misoperation
area
10
500

mW
80
Contact resistance

CR
60 0 10 20 30 40 50 60
AT
Pull-in
40

Before test After test

(7) Vibration test

(20 G - 10 to 1000 Hz)


AT
60

50

40
Pull-in and Drop-out

30
PI

20
DO
10

mW
80
Contact resistance

CR
60

40

Before test After test


ORD211

LIFE EXPECTANCY DATA: ORD211

(%)
99.9

90
No failure
70

Cumulative failure rate


50 5 mA 1 mA 100 mA
30

10
Load conditions 5

Voltage : 5 VDC 1
Current : 100 mA, 1 mA, 5 mA
Load : Resistive load
0.1
0 2 3 5 7 10 5 2 3 5 7 10 6 2 3 5 7 10 7 2 3 5 7 10 8
Number of operations * Arrow indicates number
of operations where
test was completed

(%)
99.9

90 No failure
70
Cumulative failure rate

100 mA 10 mA 5 mA
50
30

10
Load conditions 5

Voltage : 12 VDC 1
Current : 5 mA, 10 mA, 100 mA
Load : Resistive load
0.1
0 2 3 5 7 10 5 2 3 5 7 10 6 2 3 5 7 10 7 2 3 5 7 10 8
Number of operations * Arrow indicates number
of operations where
test was completed

(%)
99.9

90 No failure
70
Cumulative failure rate

50 50 mA 10 mA 1 mA
30

10
Load conditions 5

Voltage : 24 VDC 1
Current : 1 mA, 10 mA, 50 mA
Load : Resistive load
0.1
0 2 3 5 7 10 5 2 3 5 7 10 6 2 3 5 7 10 7 2 3 5 7 10 8
Number of operations * Arrow indicates number
of operations where
test was completed
This datasheet has been downloaded from:

www.DatasheetCatalog.com