Professional Documents
Culture Documents
ORD211
General Purpose Ultraminiature (Low-level Load 24 V Max.)
GENERAL DESCRIPTION
The ORD211 is a small single-contact reed switch designed for general control of low-level loads
less than 24 V. The contacts are sealed within the glass tube with inert gas to maintain contact
reliability.
Features
(1) Reed contacts are hermetically sealed within a glass tube with inert gas and do not receive any
influence from the external atmospheric environment.
(3) The structure comprises an operating system and electrical circuits coaxially. Reed switches
are suited to applications in radio frequency.
(5) Superior corrosion resistance and wear resistance of the contacts assures stable switching
operation and long life.
(6) With a permanent magnet installed, reed switches economically and easily become proximity
switches.
MAX 10.0
35.7 ±0.3
2. Control equipment
3. Communication equipment
4. Measurement equipment
5. Household appliances
ORD211
ELECTRICAL CHARACTERISTICS
Rated Value
Parameter Symbol Condition Unit
Min. Typ. Max.
Pull-in Value PI — 10 — 40 AT
Drop-out Value DO — 5 — — AT
Contact Resistance CR — — — 100 mW
Breakdown Voltage — — 150 — — VDC
Insulation Resistance — — 109 — — W
Electrostatic Capacitance — — — — 0.2 pF
Contact Rating — — — — 1.0 VA
DC
Maximum Switching Voltage — — — — 24 AC V
Maximum Switching Current — — — — 0.1 A
Maximum Carry Current — — — — 0.3 A
95
40
Cumulative frequency percent
90
80
70
30
Drop-out
60
50
40
30
20 20
10
5
10
1
0 0.1
10 20 30 40 50 AT 40 60 80 100 mW
Pull-in Contact resistance
ORD211
(DC 100 V)
99.9
DC : V 99
400
95
Breakdown voltage
0 1
10 20 30 40 50 AT
Pull-in 0.1
10 10 10 11 10 12 10 13 10 14 W
Insulation resistance
(1 MHz)
pF
0.4
Electrostatic capacitance
0.3
0.2
0.1
0
10 20 30 40 50 AT
Pull-in
ORD211
OPERATING CHARACTERISTICS
Rated Value
Parameter Unit
Min. Typ. Max.
Operate Time — — 0.3 ms
Bounce Time — — 0.3 ms
Release Time — — 0.05 ms
Resonant Frequency 7000 7500 8000 Hz
Maximum Operating Frequency — — 500 Hz
99
ms
0.5 Cumulative frequency percent
95
90
0.4 80
70
60
Operate time
50
0.3 40
30
20
0.2 10
5
1
0.1
0.1
0 0.1 0.2 0.3 0.4 ms
0
10 20 30 40 50 AT Bounce time
Pull-in
ms 99
15
95
Cumulative frequency percent
90
10
Release time
80
70
60
5 50
40
30
20
0 10
10 20 30 40 50 AT
5
Drop-out
1
0.1
7000 7500 8000 Hz
Resonant frequency
ORD211
MECHANICAL CHARACTERISTICS
(1) Lead tensile test (static load) (2) Lead tensile strength
(2.27 kg - 10 sec) 99.9
AT
60 99
95
50
60
50
40
30
30 20
PI 10
5
20
1
DO
0.1
10
0 2 4 6 8 10 kg
Breaking load
0
mW
80
Contact resistance
CR
60
40
ENVIRONMENTAL CHARACTERISTICS
(1) Temperature characteristics
CR
40
30
20 DO
Rate of change (percent)
PI
10
–10
–20
–30
50 50
40
Pull-in and Drop-out
40
20 20
DO DO
10 10
0 0
mW mW
80 80
Contact resistance
Contact resistance
CR CR
60 60
40 40
(4) High temperature storage test (5) Low temperature storage test
(125°C - 500 H) ( –40 °C - 500 H)
AT AT
60 60
50 50
40
Pull-in and Drop-out
40
Pull-in and Drop-out
30 30
PI PI
20 20
DO DO
10 10
0 0
mW mW
80
Contact resistance
80
Contact resistance
CR CR
60 60
40 40
(open Æ close)
(30 G - 11 ms)
AT
G
60
1500
50
40
Pull-in and Drop-out
1000
30
Acceleration
PI
20
DO Misoperation
area
10
500
mW
80
Contact resistance
CR
60 0 10 20 30 40 50 60
AT
Pull-in
40
50
40
Pull-in and Drop-out
30
PI
20
DO
10
mW
80
Contact resistance
CR
60
40
(%)
99.9
90
No failure
70
10
Load conditions 5
Voltage : 5 VDC 1
Current : 100 mA, 1 mA, 5 mA
Load : Resistive load
0.1
0 2 3 5 7 10 5 2 3 5 7 10 6 2 3 5 7 10 7 2 3 5 7 10 8
Number of operations * Arrow indicates number
of operations where
test was completed
(%)
99.9
90 No failure
70
Cumulative failure rate
100 mA 10 mA 5 mA
50
30
10
Load conditions 5
Voltage : 12 VDC 1
Current : 5 mA, 10 mA, 100 mA
Load : Resistive load
0.1
0 2 3 5 7 10 5 2 3 5 7 10 6 2 3 5 7 10 7 2 3 5 7 10 8
Number of operations * Arrow indicates number
of operations where
test was completed
(%)
99.9
90 No failure
70
Cumulative failure rate
50 50 mA 10 mA 1 mA
30
10
Load conditions 5
Voltage : 24 VDC 1
Current : 1 mA, 10 mA, 50 mA
Load : Resistive load
0.1
0 2 3 5 7 10 5 2 3 5 7 10 6 2 3 5 7 10 7 2 3 5 7 10 8
Number of operations * Arrow indicates number
of operations where
test was completed
This datasheet has been downloaded from:
www.DatasheetCatalog.com