System Overview Cat.No. 15650


Analyzer type Manual 2 Channel coagulation Instrument
(Clotting, chromogenic, immunoturbidimetric)
Reagent System Open
# of parameters 18
Languages English, German, French,
Italian, Spanish, Portuguese
Manual languages avaiable English
Russian
User interface Foil keyboard with 24 keys
Display 4 line x 20 character LCD (Liquid Crystal Display)
1 LED (Temperature ready)
HumaClot DUOPlus
Manual 2-Channel Coagulation Instrument

Tests Parameters Prothrombin Time (PT)


Activated partial thromboplastin time (aPTT)
Thrombin Time (TT), Venom Time (VT)
Fibrinogen (FIB), Factors (FII - FXII)
Antithrombin (AT3), Heparin (HEP)
Activated PC resistance (APCR)
Lupus Anticoagulant (Screen, Confirm)
D-Dimer (DD), Protein C (PC), Protein S (PS)
von Willebrand Factor (VWF)
Ecarin Chromogenic Assay Thrombin (ECAT) & Hirudin (ECAH)
Plasminogen (PLG), α2-Antiplasmin (A2AP)
Calibration Prothrombin Time (PT) = ISI & 3 points (variable 100 - 1 %)
DD = 3 Points
FIB = 5 points
aPTT & TT = Normal Value
Self check Yes
Result display PT : seconds, INR, ratio, activity %, extinction
aPTT & TT: seconds, ratio, activity %
FIB: seconds, mg/dl
DD: Δ OD, ng/dl

Sample Sample type Plasma


Sample positions 12 cuvette pre-warming positions at 37 °C
Sample volume 100µl = TT
50µl = PT, aPTT
25µl = DD
Sample barcode Optional

Reagent Reagent positions 5, heated at 37°C


Reagent stirring bar Yes, 2 reagent positions

Reading Light source 2 LEDs


Wavelenght 400nm
Features Variable pulse modulation
Variable detector amplification
Optical range 0.00. - 3.000 OD
AD-converter 18 Bit (16 bit used)


Data Processing Interface 2 RS232, 1x pippette
Printer Yes Serial 9600 Bd, 8 bits, 1 Stop, no parity
Barcode Yes Serial
Pipette Yes (optional)
LIS Yes


General Physical dimension (W x D x H) Instrument without any components: 20.5 x 29 x 8 cm
Space required for routine use: 20.5 x 35 x 12 cm
Packaging: 52.5 x 33 x 20 cm
Weight: Gross: 3.6 kg, net: 1.4 kg
Electrical requirements Input: 100...240 Vac, 47...63 Hz; Power consumption: 42 W max.
Output: +5Vdc/5A; +15Vdc/2A; -15Vdc/0.8A
Enviromental Operating temperature: 18…25°C
Humidity: < 70 % non-condensing

Accessories
Standard Accessories Quantity Cat. No. Consumables Cat. No.
Double Cuvettes (25pcs.) 1 15651/1025 Hemostat aPTT-EL (6 x 4 ml / 240 Tests) 33002
Label ”Biohazard“ 1 15651/142 Hemostat D-Dimer (40 Tests) 36002
Power Cord (Europe) 1 15651/14 Hemostat Fibrinogen (100 Tests) 32002
Power Supply 100-240 Vac 1 15651/141 Hemostat Thrombin Time (60 Tests) 34002
Reagent Adapter Ø23.4/Ø16.0 mm 1 15651/11 Hemostat Thromboplastin-SI (6 x 2ml / 60 Tests) 31002
Reagent Adapter Ø24.1/Ø22.6 mm 1 15651/12 Hemostat Thromboplastin-SI (6 x 10ml / 300 Tests) 31003
Reagent Container (5 pcs.) 1 15651/165 Hemostat Control Plasma Normal (6 x 1ml) 35001
RS232 Printer Cable 1 15651/26 Hemostat Control Plasma Abnormal (6 x 1ml) 35002
Sheet ”Biohazard“ 1 15651/144 Hemostat D-Dimer Control High/Low (4 x 1ml) 36012
Stirring Bars (1 pc.) 1 15651/131 Single Cuvettes (500 pcs.) 18690
User Manual 1 15650/1 Double Cuvettes (250 pcs.) 15651/10
Warranty Card 1 15651/143 Thermal Printer Paper (5pcs.) 18909/20

Additional Accessories Cat. No.


AutoHumaPette 25 µl, 50 µl, 100 µl, 200 µl 19515A
Hand Held CCD Barcode Reader 15651/60
Stirring Bars (4 pcs.) 15651/13
Thermo Printer EU 230VAC 15651/20 Thermo Printer AutoHumaPette
Thermo Printer US 120VAC 15651/21 Cat.No. 15651/20/21/22 Cat.No. 19515A
Thermo Printer JP 120VAC 15651/22
Reagent Adapter Ø23.4/Ø16 mm 15651/11
Reagent Adapter Ø24.1/Ø22.6 mm 15651/12
Reagent Container 22.5 mm (100 pcs.) 15651/16
Reagent Container 16 mm (100pcs.) 15651/17

HemoStat Thromboplastin-SI Hand Held CCD Barcode Reader


Cat.No. 31002 Cat.No. 15651/60