You are on page 1of 20

List of BGI Standard Commercial Cyclones Rev.

10, April, 2010

Type No. Name D50-μm Q - lpm Sharpness Calculator


VSCC 2.946 EPA Reference 2.5 16.67 1.157 Y
SCC 1.062 Triplex 1/2.5/4 3.5/1.5/1 1.21 Y
SCC 1.829 Photometer/Environmental Sampler 2.5 5 Y
SCC 2.654 Photometer/Environmental Sampler 2.5 10 Y
SCC 2.229 PM1 1 16.67 1.17 Y
SCC 3.495 PM2.5 2.5 16.67 1.19 Y
GK 2.05 KTL 2.5 4 1.32 Y
GK 2.05 SH KTL 2.5 3.5 1.32 Y
GK 2.69 Resp./Thoraccic 4/10 4.2/1.6 Y
BGI 4 H-D 4 2.2 Y
SCC 0.732 Photometer/Environmental Sampler 1 2 Y
SCC 1.197 Photometer/Environmental Sampler 1/2.5 5/2.27 Y

The purpose of this list is to present a calculator for each of the BGI cyclones for which there is a mathematical model. It should be
understood that these "calculators" are derived from the model which is deduced from actual test results. Where a cyclone has
been tested at a particular set of conditions, the information is reliable. Extrapolations are assumed to be reliable.
The main purpose of the calculator is to assist investigators who have operated at a flow rate for which there is no data, to
appreciate their results. The secondary purpose of the calculator is to select a set of operating parameters for a specific study.
All pressure drop data was collected as a separate study.
All test data was taken at Engineering standard conditions.
The publication and public availability of the information contained in these documents does not place BGI under obligation as to
the correctness of the information nor any consequences resulting from the usage thereof .
R. Gussman

Link
http://www.bgiusa.com/aam/vscc.htm
http://www.bgiusa.com/ihi/triplex.htm
http://www.bgiusa.com/aam/sccphoto.htm
http://www.bgiusa.com/aam/sccphoto.htm
http://www.bgiusa.com/aam/pm1scc.htm
http://www.bgiusa.com/aam/pm25scc.htm
http://www.bgiusa.com/ihi/ktl.htm
http://www.bgiusa.com/ihi/ktl.htm
http://www.bgiusa.com/ihi/hfrtc.htm
http://www.bgiusa.com/ihi/bgi4l.htm
http://www.bgiusa.com/aam/sccphoto.htm
http://www.bgiusa.com/aam/sccphoto.htm

s a mathematical model. It should be


est results. Where a cyclone has
umed to be reliable.
or which there is no data, to
parameters for a specific study.

ot place BGI under obligation as to


Lpm D50 HSE test data
2 19.768 18 2.36
4 10.057 15 2.758
6 6.773
VSCC - 2.946 11.4 3.57
8 5.116 15.7 2.66
10 4.116 5 18.7 2.295
12 3.446
14 2.965
4.5
16 2.603 4
18 2.32
3.5
D50
20 2.094 f(x) = 31.4800315549551 x^-0.896294180195796
3
D50= 2.50
2.5
Lpm= 16.67
2
1.5
1
Work Area 0.5
Enter in Red
Answer in Blue 0
Q-lpm D50 10 12 14 16 18 20
16.67 2.53 Lpm

31-Jul-08 Operator: rg Work Area Q vs. DP @ 760/20


VSCC 2.946 S/N 110308-5 Enter in RED Rank 2 Eqn 8156 [Power_] y=ax^b
Qs corrected to: BP=760 mm of Hg, T= 20 C Answer in BLUE r^2=0.99990895 DF Adj r^2=0.99989378 FitStdErr=0.020788523 Fstat=142773.14
Room BP: 751.3 mm of Hg Q-lpm SP a=0.0053042664
RoomTemp: 22.5 C 16.67 2.2 b=2.1473552
8
Reading 7
Critical Abs. P Temp. DP DP
Venturi Crit. Vent. Crit. Vent. Qs DUT DUT 6
Number mm of Hg C Lpm Cm of H2O hPa
DP - Cm. of H2O

#1 128 22.2 4.944 0.195 0.191 5


174.95 22.3 6.833 0.35 0.343
229 22.3 9.005 0.625 0.613 4
279.45 22.2 11.029 0.925 0.907
319.8 22.3 12.655 1.225 1.201 3
376.2 22.2 14.917 1.750 1.716
2
419.5 22.4 16.668 2.195 2.153
457.2 22.4 18.183 2.685 2.633 1
501.3 22.0 19.930 3.270 3.207
549.2 22.1 21.860 4.025 3.947 0
621.15 22.2 24.759 5.200 5.099 0 10 20 30
708.8 22.2 28.280 6.950 6.816 Q - Lpm
#2 203.6 21.8 7.971 0.035 0.034
296.5 21.8 11.698 0.090 0.088
359.4 21.8 14.222 0.115 0.113
SCC1.062 no calibration chamber
SCC 1.062 Combined Data
Q D50
3320 Nov
4 0.86
1.8 1.97 8
4 0.85 f(x) = 3.99741862953057 x^-1.11659429594352
1.2 3.1 3310 Nov 7 R² = 0.996707078077178

D50 - μM
1.8 2.1
1.2 3.2 6
1.5 2.45
5
1.6 2.45
1 4.2 4
1.1 3.75
3 1.14 3320 Jan 3
4 0.86
2
3.5 1.01
1

Work Area 0
Enter in Red 0.5 1 1.5 2 2.5 3 3.5 4 4.5
Answer in Blue
Flow Rate - Lpm
Q-lpm D50
8 0.39

27-Aug-08 Operator: rg Work Area CLIPBRD.WK1


SCC1.062 Enter in RED Rank 2 Eqn 8156 [Power_] y=ax^b
r^2=0.99995739 DF Adj r^2=0.99991477 FitStdErr=0.025914748 Fstat=70396.792
Qs corrected to: BP=760 mm of Hg, T= 20 C Answer in BLUE a=0.36935462
Room BP: 762.1 mm of Hg Q-lpm SP b=2.2473472
RoomTemp: 22.5 C 3.5 8.19 10
9
Reading 8
Critical Abs. P Temp. DP DP
DP - Cm of H2O

7
Venturi Crit. Vent. Crit. Vent. Qs DUT DUT
Number mm of Hg C Lpm Cm of H2O hPa 6
#2D 84.45 22.3 0.851 0.290 0.284 5
150.8 22.2 1.554 1.010 0.990
4
205.9 22.2 2.138 2.040 2.001
300.1 22.3 3.138 4.800 4.707 3
388.55 22.4 4.077 8.700 8.532 2
1
0
0.5 1.5 2.5 3.5 4.5
Q vs. DP @ 760/20
Q D50 SCC 1.829 rg 25-Feb-08
2.0 7.243
2.5 5.590
3.0 4.523
3.5 3.782 SCC 1.829
4.0 3.239

D50 - Micrometers
4.5 2.825
5.0 2.510 8
5.5 2.238 7.5
6.0 2.023 7 f(x) = 16.1801633847555 x^-1.15992804803619
6.5
Work Area
Enter in RED 6
Answer in BLUE 5.5
Q-lpm D50 5
8 1.5
4.5
4
3.5
3
2.5
2
1.5
1
0.5
0
2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0
Q - LPM

20-Jan-09 Work Area


Qs corrected to: BP=760 mm of Hg, T= 20 C Enter in RED Q vs. DP @ 760/20
Room BP: 750 mm of Hg Answer in BLUE Rank 3 Eqn 8156 [Power_] y=ax^b
r^2=0.99963912 DF Adj r^2=0.99949477 FitStdErr=0.061711042 Fstat=16619.977
RoomTemp: 19.6 C Q-lpm SP
a=0.040433666
10 7.1
b=2.2438339
Reading
10
Critical Abs. P Temp. DP DP
Venturi Crit. Vent. Crit. Vent. Qs DUT DUT 9
Number mm of Hg C Lpm Cm of H2O hPa 8
# 1D 179.9 20.2 7.188 3.420 3.354
223.1 20.2 8.951 5.400 5.296 7
DP - Cm of H2O

274.3 20.2 11.040 8.900 8.728


6
Room BP: 750 mm of Hg 5
RoomTemp: 19.6 C
4
#2D 148.7 20.1 1.546 0.130 0.127
254.6 20.1 2.678 0.370 0.363 3
349.9 20.1 3.697 0.780 0.765
461.5 20.1 4.890 1.435 1.407 2
599.4 20.1 6.365 2.610 2.560 1
0
0 4 8 12
Q - Lpm
Lpm D50
5 5.548
6
7
4.489
3.754
SCC - 2.645
8 3.215
9 2.804 6

D50 - AED
10 2.481
11 2.221 f(x) = 35.9526341447666 x^-1.1611129728355
5
12 2.008
13 1.829
14 1.679 4
15 1.549
3
Work area
Enter in Red
Answer in Blue 2
Q-lpm D50
10 2.48 1

0
5 6 7 8 9 10 11 12 13 14 15
Q - Lpm

20-Jan-09 Operator: rg
SCC 2.654 Work Area
Qs corrected to: BP=760 mm of Hg, T= 20 C Enter in RED Q vs. DP @ 760/20
Room BP: 751.8 mm of Hg Answer in BLUE Rank 3 Eqn 8156 [Power_] y=ax^b
RoomTemp: 19.6 C Q-lpm SP r^2=0.9995707 DF Adj r^2=0.99939899 FitStdErr=0.064677696 Fstat=13970.388
15 3.8 a=0.0088501376
b=2.2377792
Reading 9
Critical Abs. P Temp. DP DP
Venturi Crit. Vent. Crit. Vent. Qs DUT DUT 8
Number mm of Hg C Lpm Cm of H2O hPa 7
# 1D 176.8 20 7.039 0.710 0.696
DP - Cm of H2O

225.7 20.1 9.032 1.240 1.216 6


274.7 20.1 11.026 1.940 1.902 5
319.7 20.1 12.857 2.430 2.383
375 20.0 15.103 3.900 3.825 4
429.8 19.9 17.326 5.100 5.001 3
528.7 19.9 21.348 8.400 8.238
2
Room BP: 751.8 mm of Hg
1
RoomTemp: 19.6 C
#2D 353.9 20.0 3.729 0.180 0.177 0
458.9 20.0 4.849 0.300 0.294 0 5 10 15 20 25
Q - Lpm
at=13970.388

25
SCC D50 vs. Lpm

Lpm D50 SCC 2.229

D50 - A.E.D.
10 1.806
11 1.618 2
12 1.464
13 1.335 f(x) = 25.6299315096585 x^-1.1520589642754
1.5
14 1.225
15 1.132
16 1.051 1
17 0.98
18 0.917 0.5
19 0.862
20 0.813
0
10 11 12 13 14 15 16 17 18 19 20

Work area Q - LPM


Enter in Red
Answer in Blue
Q D50
16.7 1.00

4-Aug-08 Operator: rg
SCC 3.495 Work Area DP vs Q @ 760/20
Qs corrected to: BP=760 mm of Hg, T= 20 C Enter in RED Rank 3 Eqn 8156 [Power_] y=ax^b
Room BP: 756.1 mm of Hg Answer in BLUE r^2=0.99939318 DF Adj r^2=0.99929204 FitStdErr=0.24373644 Fstat=21410.088
RoomTemp: 22.5 C Q-lpm SP a=0.018943682
16.67 10.1 b=2.2315878
Reading 35
Critical Abs. P Temp. DP DP
30
Venturi Crit. Vent. Crit. Vent. Qs DUT DUT
Number mm of Hg C Lpm Cm of H2O hPa
25
#1 124.8 22.6 4.791 0.615 0.603
DP - Cm. of H2O

175.9 22.6 6.834 1.320 1.294 20


223.9 22.6 8.753 2.310 2.265
274.9 22.6 10.792 3.735 3.663 15
320.5 22.4 12.607 5.200 5.099
374.8 22.6 14.786 7.500 7.355 10
418.1 22.6 16.517 9.700 9.512
459.35 22.2 18.142 12.200 11.964 5
499.75 22.1 19.748 15.000 14.710
549.3 22.1 21.726 18.500 18.142 0
620.8 22 24.571 24.500 24.026 0 10 20 30
692.2 22.1 27.429 30.200 29.616 Q - Lpm
#2 207 22.6 8.078 0.135 0.132
296.9 22.6 11.672 0.275 0.270
357 22.6 14.074 0.420 0.412
0
_] y=ax^b
0.24373644 Fstat=21410.088

20 30
D 50- A E D M icro m eters
SCC D50 vs. Lpm

Lpm D50
10 4.525
11 4.051
12 3.622 D50 vs Flow Rate - Lpm
13 3.337
14 3.062 5
15 2.826
16 2.622 4.5
f(x) = 64.7300131033416 x^-1.15662223344795
17 2.444 4
18 2.287
19 2.148 3.5
20 2.024
3
2.5
2
Work area 1.5
Enter in Red
1
Answer in Blue
10 11 12 13 14 15 16 17 18 19 20
Q D50
Flow Rate - Lpm
17.72 2.33

4-Aug-08 Operator: rg Work Area


DP vs Q @ 760/20
SCC 3.495 Enter in RED
Rank 2 Eqn 8156 [Power_] y=ax^b
Qs corrected to: BP=760 mm of Hg, T= 20 C Answer in BLUE
r^2=0.99947907 DF Adj r^2=0.99939225 FitStdErr=0.046960795 Fstat=24942.438
Room BP: 756.1 mm of Hg Q-lpm SP
a=0.005687401
RoomTemp: 22.5 C 16.67 2.2 b=2.1207645
7
Reading
Critical Abs. P Temp. DP DP 6
Venturi Crit. Vent. Crit. Vent. Qs DUT DUT
Number mm of Hg C Lpm Cm of H2O hPa
5
#1 125 21.9 4.788 0.170 0.167
DP- Cm. of H2O

176 21.9 6.822 0.340 0.333 4


224.3 22.3 8.760 0.560 0.549
275.9 22.2 10.817 0.870 0.853 3
320 22.3 12.582 1.195 1.172
376.2 22.2 14.822 1.690 1.657
419.6 22.4 16.566 2.150 2.108
2
459.1 22.4 18.144 2.600 2.550
499.45 22.0 19.729 3.250 3.187 1
549.8 22.1 21.745 3.990 3.913
620.7 22.2 24.583 5.100 5.001 0
691.25 22.2 27.400 6.300 6.178 0 10 20 30
#2 205.4 21.8 7.992 0.045 0.044 Q - Lpm
300.2 21.8 11.772 0.095 0.093
356.3 21.8 14.008 0.120 0.118
KTL Cyclone. D50 vs. Q. Rg - 22 Mar 01

D50 A.E .D. - M icro m eters


LPM D50
1.5 7.67
2.0 5.52
2.5 4.28 KTL (GK 2.05)
3.0 3.47
3.5 2.91
8
4.0 2.50
4.5 2.18 7 f(x) = 12.1882859007775 x^-1.14299358545477
5.0 1.94
6
5
4
3
Work area
Enter in Red 2
Answer in Blue
Q D50 1
4 2.50 1 1.5 2 2.5 3 3.5 4 4.5 5
Flow - Lpm

Q vs. DP @ 760/20
11-Aug-08 Operator: rg Work Area Rank 2 Eqn 8156 [Power_] y=ax^b
GK 2.05 Enter in RED r^2=0.99986358 DF Adj r^2=0.9998246 FitStdErr=0.063831695 Fstat=58632.413
Qs corrected to: BP=760 mm of Hg, T= 20 C Answer in BLUE a=0.031765439
Room BP: 754.2 mm of Hg Q-lpm SP b=2.4329673
RoomTemp: 22.5 C 10 8.6 17.5

Reading 15
Critical Abs. P Temp. DP DP
Venturi Crit. Vent. Crit. Vent. Qs DUT DUT
12.5
Number mm of Hg C Lpm Cm of H2O hPa
DP - Cm. of H2O

#1 123.9 21.3 4.746 1.410 1.383 10


175.3 21.3 6.797 3.490 3.423
222.8 21.2 8.690 6.000 5.884 7.5
275.6 21.2 10.796 10.400 10.199
319.9 21.2 12.563 15.000 14.710 5
Room BP: 754.7 mm of Hg
RoomTemp: 21 C
#2 119.8 21 1.313 0.064 0.063 2.5
156.1 21 1.726 0.140 0.137
203.5 21.1 2.265 0.245 0.240 0
285.05 21.2 3.193 0.510 0.500
0 5 10 15
356 21.2 3.999 0.890 0.873 Q - Lpm
KTL Cyclone. D50 vs. Q. Rg - 22 Mar 01

LPM D50

D50 - Micrometers
1.5 5.52
2.0 4.28 KTL with Shroud
2.5 3.47
3.0 2.91
6
3.5 2.5
4.0 2.18 5.5
f(x) = 8.24171793103936 x^-0.955190352539101
4.5 1.94 5
4.5
4
3.5
3
2.5
Work area
Enter in Red 2
Answer in Blue 1.5
Q D50
8.5 1.07 1
1 1.5 2 2.5 3 3.5 4 4.5 5
Q - lpm

11-Aug-08 Operator: rg Work Area Q vs. DP @ 760/20


GK 2.05 SH Enter in RED Rank 2 Eqn 8156 [Power_] y=ax^b
Qs corrected to: BP=760 mm of Hg, T= 20 C Answer in BLUE r^2=0.99992243 DF Adj r^2=0.99990027 FitStdErr=0.074496484 Fstat=103130.85
Room BP: 755.2 mm of Hg Q-lpm SP a=0.061242226
RoomTemp: 21 C 10 13.2 b=2.3323665
25
Reading
Critical Abs. P Temp. DP DP
Venturi Crit. Vent. Crit. Vent. Qs DUT DUT 20
Number mm of Hg C Lpm Cm of H2O hPa
DP - Cm. of H2O

#1 124.75 20.9 4.767 2.480 2.432 15


176.6 21.2 6.838 5.300 5.198
219.5 21.2 8.547 9.100 8.924
274.8 21.2 10.750 15.600 15.298 10
328 21.1 12.865 23.700 23.242
Room BP: 755.1 mm of Hg
RoomTemp: 21 C 5
#2 112.1 20.9 1.225 0.125 0.123
154 20.8 1.700 0.205 0.201
204.7 20.8 2.275 0.440 0.431 0
282.6 20.8 3.159 0.890 0.873 0 5 10 15
353.4 20.8 3.962 1.600 1.569 Q - Lpm
GK 2.69 Cyclone. D50 vs. Q rg 6-Aug-07

Lpm D50

D50 A.E.D. - Micrometers


1.6 10
2.7 6.22
4.2 4 12
f(x) = 17.7037761725892 x^-1.05215245985221
5 3.47
11
6 2.82
7 2.36 10
8 2.03
9
9 1.77
10 1.57 8
11 1.41
12 1.27 7

13 1.16 6
14 1.07
15 0.988 5

Work Area 3
Enter in Red
2
Answer in Blue
Q D50 1
8.1 2.0
0
1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 7.5 8
Flow - Lpm

8-Aug-08 Operator: rg Work Area


DP vs Q @ 760/20
GK 2.69 Enter in RED
Rank 2 Eqn 8156 [Power_] y=ax^b
Qs corrected to: BP=760 mm of Hg, T= 20 C Answer in BLUE
r^2=0.99975548 DF Adj r^2=0.99969434 FitStdErr=0.064358122 Fstat=36797.089
Room BP: 751.6 mm of Hg Q-lpm SP
a=0.013255612
RoomTemp: 21.5 C 9 2.6
b=2.4036801

Reading
12.5
Critical Abs. P Temp. DP DP
Venturi Crit. Vent. Crit. Vent. Qs DUT DUT
Number mm of Hg C Lpm Cm of H2O hPa 10

#1 126.8 20.9 4.872 0.660 0.647


174.8 20.9 0.905 0.888 7.5
DP - Cm. of H2O

224.4 20.9 8.775 2.530 2.481


274.6 20.9 10.782 4.050 3.972
319.9 20.9 12.594 5.700 5.590
5
375 20.9 14.797 8.600 8.434
416.9 20.9 16.472 11.200 10.983
Room BP: 750.5 mm of Hg
RoomTemp: 21.5 C 2.5
#2 121.5 21 1.340 0.045 0.044
156.9 21 1.745 0.065 0.064
205.4 21 2.299 0.120 0.118 0
303.2 21 3.416 0.280 0.275 0 5 10 15
355.9 21 4.018 0.400 0.392 Q - Lpm
Q D50 SCC 0.732 rg 10-Sep-05
0.5 5.006

D50 Micrometers
1.0 2.239
1.5 1.398
2.0 1.001 SCC 0.732
2.5 0.773
3.0 0.625 5
3.5 0.523 4.5 f(x) = 2.23871971069593 x^-1.16083145264709
4.0 0.448 4
3.5
Work Area 3
Enter in RED 2.5
2
Answer in Blue
1.5
Q-lpm D50 1
0.9 2.53 0.5
0
0 0.5 1 1.5 2 2.5 3 3.5 4
Q - LPM

22-Jan-09 Work Area Q vs. DP @ 760/20


Qs corrected to: BP=760 mm of Hg, T= 20 C Enter in RED Rank 13 Eqn 8156 [Power_] y=ax^b
Room BP: 755.7 mm of Hg Answer in BLUE r^2=0.99811605 DF Adj r^2=0.99434816 FitStdErr=0.10223323
RoomTemp: 20.2 C Q-lpm SP a=2.4486907
2 9.9 b=2.0119551
Reading 10
Critical Abs. P Temp. DP DP 9
Venturi Crit. Vent. Crit. Vent. Qs DUT DUT
Number mm of Hg C Lpm Cm of H2O hPa 8
Room BP: 750 mm of Hg
7
RoomTemp: 19.6 C
DP - Cm of H2O

#2D 135.9 20.5 1.411 4.910 4.815 6


5
Room BP: 755.7 mm of Hg 4
RoomTemp: 20.2 C
3
#3D 241.65 20.6 0.390 0.480 0.471 2
448.9 20.6 0.744 1.380 1.353
532.7 20.6 0.888 1.840 1.804 1
0
0 0.4 0.8 1.2 1
Q - Lpm
3.5 4

Q vs. DP @ 760/20
Rank 13 Eqn 8156 [Power_] y=ax^b
DF Adj r^2=0.99434816 FitStdErr=0.10223323 Fstat=1059.6019
a=2.4486907
b=2.0119551

4 0.8 1.2 1.6 2


Q - Lpm
Q D50 SCC 1.197 rg 14-Sep-05
1.0 6.479

D50 Micrometers
2.0 2.897
3.0 1.81
4.0 1.296 SCC 1.197
5.0 1
6.0 0.809 8
7
6 f(x) = 6.47929129938743 x^-1.16103969864299
5
Work Area
Enter in RED 4
Answer in Blue 3
Q-lpm D50 2
8 0.58 1
0
0 1 2 3 4 5 6
Q - LPM

20-Jan-09 Work Area


Q vs. DP @ 760/20
Qs corrected to: BP=760 mm of Hg, T= 20 C Enter in RED
Rank 3 Eqn 8156 [Power_] y=ax^b
Room BP: 750.4 mm of Hg Answer in BLUE
r^2=0.99986078 DF Adj r^2=0.99958235 FitStdErr=0.061886395 Fstat=14364.251
RoomTemp: 19.6 C Q-lpm SP
a=0.28341769
5 10.3
b=2.2305144
Reading 12.5
Critical Abs. P Temp. DP DP
Venturi Crit. Vent. Crit. Vent. Qs DUT DUT
Number mm of Hg C Lpm Cm of H2O hPa 10
Room BP: 750 mm of Hg
RoomTemp: 19.6 C
DP - Cm of H2O

#2D 135.8 20.2 1.408 0.680 0.667


249.5 20.2 2.624 2.450 2.403
7.5
347.1 20.2 3.668 5.100 5.001
476 20.2 5.047 10.500 10.297
5

2.5

0
1 2 3 4 5
Q - Lpm
Higgins and Dewell Cyclone performance model. 17-Oct-03 rg

Based on information provided by Lee Kenny on 23 Oct 94

D50 - Microm eters


Q - lpm D50 - μm
1 10.40
2 4.85
3 3.11 12
4 2.26
5 1.77 10 f(x) = 10.4039691533402 x^-1.1
6 1.45
7 1.22 8
8 1.06
6
9 0.93
10 0.83 4

0
0 1 2 3 4 5 6 7 8 9 10
Q - LPM

Work Area
Input flow rate in red
Answer returns in Blue
Q - lpm D50 - μm
2.5 3.80

27-Aug-08 Operator: rg Work Area Q vs. DP @ 760/20


H-D Enter in RED Rank 5 Eqn 8156 [Power_] y=
Qs corrected to: BP=760 mm of Hg, T= 20 C Answer in BLUE r^2=0.99890842 DF Adj r^2=0.99836264 FitStdErr=0.133
Room BP: 762.1 mm of Hg Q-lpm SP a=0.079566598
RoomTemp: 22.5 C 2.2 0.5 b=2.2162789
12.5
Reading
Critical Abs. P Temp. DP DP
Venturi Crit. Vent. Crit. Vent. Qs DUT DUT 10
Number mm of Hg C Lpm Cm of H2O hPa
DP - Cm of H2O

# 1D 118.9 22.3 4.657 2.500 2.452 7.5


175.3 22.4 6.940 5.600 5.492
221.6 22.5 8.817 10.000 9.807
5
Room BP: 762.1 mm of Hg
RoomTemp: 22.5 C
#2D 85.9 22.2 0.866 0.060 0.059 2.5
146.2 22.2 1.505 0.245 0.240
203.6 22.3 2.114 0.495 0.485
299.85 22.5 3.137 1.110 1.089 0
0 2 4 6
Q - Lpm
2.5

0
0 2 4 6
Q - Lpm
8 9 10

Q vs. DP @ 760/20
Rank 5 Eqn 8156 [Power_] y=ax^b
890842 DF Adj r^2=0.99836264 FitStdErr=0.13375758 Fstat=4575.5332
a=0.079566598
b=2.2162789

2 4 6 8
Q - Lpm
2 4 6 8
Q - Lpm

You might also like