You are on page 1of 126

Spectrum Analysis

2006-12-07 ©SKF Slide 2 [Code]


SKF [Organisation]
Basic Motions

2006-12-07 ©SKF Slide 3 [Code]


SKF [Organisation]
Module objective(s)

To introduce the concepts of spectrum analysis, and to provide


a general overview of how analysts recognize and analyze
typical machinery problems.

2006-12-07 ©SKF Slide 4 [Code]


SKF [Organisation]
FFT spectrum analysis

q.
f re
h
hig

y
e nc
FFT spectra provide tim qu
e q. fre
fre
information to help determine low

the location of the problem,


the cause of the problem and,
with trending, how long until amplitude

the problem becomes critical


frequency

2006-12-07 ©SKF Slide 5 [Code]


SKF [Organisation]
Spectrum analysis - two step approach

• First, collect
useful
information, then
• Analyze

Asset Information Page – Front and Back

2006-12-07 ©SKF Slide 6 [Code]


SKF [Organisation]
Step 1 - collect useful information

Identify all components of the machine that could cause vibration


What are the possibilities?
• The number of fan blades or impellers, gear teeth, coupling type,
belts, sheave diameters, etc.
• Type of bearings at each bearing location and their defect
frequencies
• Speeds of other machines running in the same vicinity
• Orientation, vertical or horizontal, overhung or center-hung

2006-12-07 ©SKF Slide 7 [Code]


SKF [Organisation]
Identify components that cause vibration

1800 RPM
2400 RPM

5 blade fan
motor
gearbox
gearmesh frequencies

2006-12-07 ©SKF Slide 8 [Code]


SKF [Organisation]
Step 1 - collect useful information…

Obtain all historical machinery data


• Are previously recorded values, spectra, logs, control room data, or
overall trend plots available?
• Was a baseline recorded?
• Talk with operators. Often this provides insight into the original
problem (coupling changed, flow increased, fan cleaned, etc.).
• Check maintenance records and talk to the mechanics that service
the machine.

2006-12-07 ©SKF Slide 9 [Code]


SKF [Organisation]
Step 1 - collect useful information…

Identify the machine’s running speed


Knowing the machine's running speed is critical when analyzing an FFT
spectrum. There are several ways of determining running speed.
• Read the speed from instrumentation.
• Look for peaks in the spectrum at 1800 or 3600 RPM if the machine
is a induction motor. (1500 and 3000 RPM for 50 Hz countries.)
• The running speed peak in a vibration spectrum is often the first
significant peak reading from left to right. Look for this peak and for
peaks the harmonics of running speed.
• Use a tachometer.

2006-12-07 ©SKF Slide 10 [Code]


SKF [Organisation]
Step 1 - collect useful information

Identify what type of measurement produced the FFT spectrum


• Was it a displacement, velocity, acceleration, enveloped acceleration,
etc. measurement that produced the spectrum?
• Where was the probe positioned?
• Are plots scaled consistently for easy comparison?

2006-12-07 ©SKF Slide 11 [Code]


SKF [Organisation]
Step 2 - analyze

General Analysis Techniques


• Use a coin or the probe tip to get a hand-feel of the vibration on the
machine, the base, and any piping, ductwork, or other attachments.
• Acquire tri-axial (H, V, A) vibration data at each bearing.
• For analysis purposes, acquire relative phase measurements. This
improves the likelihood of a successful diagnosis.
• Evaluate overall vibration readings across the entire machine train.
• Where does the vibration appear to originate (highest amplitude)?
• What probe directions have the highest amplitude? (significant)
• Do the dominant frequencies have a relationship to rotating components?

2006-12-07 ©SKF Slide 12 [Code]


SKF [Organisation]
Spectrum analysis - identify frequency ranges…

< 1X low frequency rotational events and harmonics high frequency events
(i.e. unbalance, misalignment, looseness, etc.) (i.e. bearing or gearmesh)

1X 10X
amplitude

2X 3X

4X

frequency

2006-12-07 ©SKF Slide 13 [Code]


SKF [Organisation]
Spectrum analysis - identify frequency ranges

• Identify any harmonics of running speed (1X, 2X, 3X, etc.).


• Identify bearing fault frequencies.
• Identify fan blade frequencies, if applicable.
• Identify number of gear teeth, if applicable.
• Identify pump impeller frequencies, if applicable.
• Identify adjacent machinery vibration, if applicable.
• With electric motors, identify peaks at line frequencies. Determine if
they are electrical or mechanical.

2006-12-07 ©SKF Slide 14 [Code]


SKF [Organisation]
Spectrum analysis - verify and determine
severity

Verify
• look for harmonics of the fault frequencies
Determine Severity
• compare vibration amplitude with ISO standards
• compare the current amplitude to past readings (best method)
• compare the amplitude to other readings obtained by similar
machines running under the same conditions

2006-12-07 ©SKF Slide 15 [Code]


SKF [Organisation]
Spectral pattern recognition

< 1X low frequency rotational events and harmonics high frequency events
(i.e. unbalance, misalignment, looseness, etc.) (i.e. bearing or gearmesh)

1X 10X
amplitude

2X 3X

4X

frequency

2006-12-07 ©SKF Slide 16 [Code]


SKF [Organisation]
Harmonics…

A harmonic is a frequency that is an exact multiple of a non-sinusoidal


(impact type) fundamental frequency

2006-12-07 ©SKF Slide 17 [Code]


SKF [Organisation]
Harmonics

• The fault fundamental frequency may be produced from


a variety of sources
• shaft speed, a pump’s vane pass frequency, bearing fault frequencies, or
gear meshing frequencies

• With rolling element bearing faults, harmonics of the


fault’s fundamental frequency typically appear first
• fault frequency harmonics are the earliest indicators that a bearing
problem exists

2006-12-07 ©SKF Slide 18 [Code]


SKF [Organisation]
Sidebands…

Sidebands are produced when one frequency modulates another or when


one amplitude modulates another.

2006-12-07 ©SKF Slide 19 [Code]


SKF [Organisation]
Sidebands

• The dominant peak appears at the primary vibration frequency


• referred to as the center frequency
• The frequency that is modulating the center frequency appears as
two peaks equally spaced around the center frequency (sidebands)
• As a problem worsens, the sideband amplitudes increase and additional sidebands
appear

• The spacing between the center frequency and the sidebands identifies the
originating problem

2006-12-07 ©SKF Slide 20 [Code]


SKF [Organisation]
Waterfall plot

A waterfall plot trends spectrum changes.

2006-12-07 ©SKF Slide 21 [Code]


SKF [Organisation]
Phase & Uses

2006-12-07 ©SKF Slide 22 [Code]


SKF [Organisation]
Analyzing “Typical” Machinery
Problems

2006-12-07 ©SKF Slide 23 [Code]


SKF [Organisation]
Unbalance Principle

2006-12-07 ©SKF Slide 24 [Code]


SKF [Organisation]
Unbalance

static / mass

couple

2006-12-07 ©SKF Slide 25 [Code]


SKF [Organisation]
Unbalance – Single Plane…

2006-12-07 ©SKF Slide 26 [Code]


SKF [Organisation]
Unbalance – Two Plane…

2006-12-07 ©SKF Slide 27 [Code]


SKF [Organisation]
Unbalance – Over Hung type…An Exception…

2006-12-07 ©SKF Slide 28 [Code]


SKF [Organisation]
Unbalance - typical spectrum (pure unbalance)

2006-12-07 ©SKF Slide 29 [Code]


SKF [Organisation]
Unbalance - typical spectrum (Overhung Rotor)

2006-12-07 ©SKF Slide 30 [Code]


SKF [Organisation]
Unbalance - typical spectrum (pure unbalance)

High 1X

Low Multiples of 1X

2006-12-07 ©SKF Slide 31 [Code]


SKF [Organisation]
Unbalance - typical indications

• (Overall vibration) - high energy, low frequency, radial vibration


• (Spectrum) - higher than normal amplitude at 1X running speed frequency
• (Spectrum) - With the high 1X, there are little or no amplitude increases at
running speed harmonic frequencies (2X, 3X, 4X, etc.)

• (Spectrum) - 1X amplitude increases proportionally to speed increases


• (Phase) - Sensor shows 90° phase shift between horizontal and vertical
positions on the same bearing

• (Phase) - For predominantly static unbalance, there is usually no phase shift


across the machine or coupling in the same measurement position.

2006-12-07 ©SKF Slide 32 [Code]


SKF [Organisation]
Unbalance - summary

• If the radial measurement's 1X amplitude is high, and all harmonics (except


vane passing) are less than 30% of the 1X and do not increase with speed, there
may be unbalance.

• If the majority of vibration is in the radial plane, and the 1X amplitude is


medium to high in amplitude, and phase readings from vertical and horizontal
measurements on the same bearing differ by 90°, there may be unbalance.

• If there is a non-synchronous peak corresponding to the 1X running speed of a


nearby machine, there may be unbalance in the other machine.

• If vibration increases in both the axial and radial measurement planes, the
machine has an overhung mass, and the axial phase measurements across the
machine or coupling are in phase, there may be unbalance.

2006-12-07 ©SKF Slide 33 [Code]


SKF [Organisation]
Misalignment

2006-12-07 ©SKF Slide 34 [Code]


SKF [Organisation]
Misalignment

2006-12-07 ©SKF Slide 35 [Code]


SKF [Organisation]
Misalignment

Angular misalignment

Parallel misalignment

2006-12-07 ©SKF Slide 36 [Code]


SKF [Organisation]
Misalignment - cause and effects

Angular misalignment Parallel/offset misalignment

2006-12-07 ©SKF Slide 37 [Code]


SKF [Organisation]
Misalignment

2006-12-07 ©SKF Slide 38 [Code]


SKF [Organisation]
Misalignment… Aligned Machine

2006-12-07 ©SKF Slide 39 [Code]


SKF [Organisation]
Misalignment… Angular

2006-12-07 ©SKF Slide 40 [Code]


SKF [Organisation]
Misalignment… Offset

2006-12-07 ©SKF Slide 41 [Code]


SKF [Organisation]
Misalignment… Combination

2006-12-07 ©SKF Slide 42 [Code]


SKF [Organisation]
Misalignment - typical spectrum

high 1X and/or 2X, 3X

2006-12-07 ©SKF Slide 43 [Code]


SKF [Organisation]
Misalignment - typical indications

• (Overall vibration) - high energy, low frequency, radial and axial vibration
• (Overall vibration) - unbalance generally produces high motion in the horizontal
plane due to differences in bearing support stiffness. If vertical amplitudes are
higher than the horizontal readings at the same bearing, misalignment is
suspected.
• (Spectrum) - higher than normal 1X and harmonic amplitudes occur in both
axial and radial positions. If 2X is less than 30% of 1X, suspect unbalance, >30%
and <50%, misalignment probable, >50% and less than 100%, strong
misalignment,
• (Spectrum) – possible vibration at number of coupling elements times RPM.
• (Phase measurements) – in the radial readings on each machine, look for
combinations of 0° and180° degree phase relationships in the vertical and
horizontal planes.

2006-12-07 ©SKF Slide 44 [Code]


SKF [Organisation]
Misalignment - summary

• Misalignment produces higher than normal vibration at running


speed and possible harmonics of running speed out to approximately
5X running speed.
• Axial vibration at running speed is generally greater than 30% of the
lowest radial amplitude.
• Phase relationships across the coupling in the axial or radial planes
may indicate “pure” forms of misalignment but are ineffective when
dealing with complex misalignment or multiple sources of vibration.
• Misalignment generally produces combinations of zero and 180-
degree phase relationships in the vertical and horizontal planes.

2006-12-07 ©SKF Slide 45 [Code]


SKF [Organisation]
Bent Shaft

2006-12-07 ©SKF Slide 46 [Code]


SKF [Organisation]
Bent shaft

• Usually appears identical


to a misalignment
problem
• Phase measurement
comparisons along the
machine train are needed
to distinguish between
the two.

2006-12-07 ©SKF Slide 47 [Code]


SKF [Organisation]
Bent shaft - diagnosis

• Axial measurements
across machine
typically 180 degrees out
of phase, and

• Radial measurements
across machine
are typically in phase

2006-12-07 ©SKF Slide 48 [Code]


SKF [Organisation]
Bent Shaft

2006-12-07 ©SKF Slide 49 [Code]


SKF [Organisation]
Bent shaft - typical indications

• (Overall vibration and spectrum characteristics) Similar to


misalignment.
• (Phase measurements) In the axial position, a phase shift of 180°
exists across the shaft, and ...
• (Phase measurements) In a radial position, there is no phase shift
between bearings across the shaft.
• If both the above phase conditions are true, the problem is probably
a bent shaft.

2006-12-07 ©SKF Slide 50 [Code]


SKF [Organisation]
Bent shaft - summary

If the primary vibration plane is in the axial direction, and there is a


dominant 1X peak, and there is no coupling present, and there is a
180° phase difference in the axial direction across the shaft, and there
is no phase shift in the radial position across the machine, then there
may be a bent shaft.

2006-12-07 ©SKF Slide 51 [Code]


SKF [Organisation]
Mechanical looseness

• The machine has come


loose from its mounting

• A machine component
has come loose

• The bearing has


developed a fault, which
has worn down the
bearing elements, or the
bearing seat

2006-12-07 ©SKF Slide 52 [Code]


SKF [Organisation]
Looseness

2006-12-07 ©SKF Slide 53 [Code]


SKF [Organisation]
Structural looseness

2006-12-07 ©SKF Slide 54 [Code]


SKF [Organisation]
Mechanical looseness - diagnosis

2006-12-07 ©SKF Slide 55 [Code]


SKF [Organisation]
Mechanical looseness - indications

• (Overall vibration) - There is high energy radial vibration, especially


in the vertical measurement plane, and
• (Overall vibration) - There is normal (low) vibration in the axial plane
• (Spectrum) - There is an abnormally high running speed amplitude,
followed by higher than normal harmonics of running speed, and
perhaps 1/2 harmonics of running speed (from 2X - 10X). Harmonic
peaks may decrease in amplitude as they increase in frequency
(except at 2X, which, when measured in the vertical position, can be
higher in amplitude).

2006-12-07 ©SKF Slide 56 [Code]


SKF [Organisation]
Mechanical looseness - summary

• If there are a series of three or more synchronous or 1/2


synchronous multiples of running speed (range 2X to 10X), and their
magnitudes are greater than 20% of the 1X, then there may be
mechanical looseness.
• If the machine is rigidly connected (no coupling or belt),
and the radial 2X is high, then there may be mechanical looseness.

2006-12-07 ©SKF Slide 57 [Code]


SKF [Organisation]
Cocked bearing

2006-12-07 ©SKF Slide 58 [Code]


SKF [Organisation]
Cocked Bearings…

2006-12-07 ©SKF Slide 59 [Code]


SKF [Organisation]
Cocked Bearing

2006-12-07 ©SKF Slide 60 [Code]


SKF [Organisation]
Cocked bearing - summary

• Like misalignment, a cocked bearing usually generates considerable


axial vibration. However, phase measurements from the suspect
bearing’s axial position help differentiate the two.
• If the phase readings among the adjacent four sensor locations vary
considerably, a cocked bearing is indicated. Success in diagnosing
this condition is directly related to the stiffness of the bearing
support and the flexibility of the shaft.

2006-12-07 ©SKF Slide 61 [Code]


SKF [Organisation]
Soft foot…

• One of the most prevalent machine installation problems


• A condition where one or more feet of a machine are not sitting flat
and fully on the base
• When a soft foot is tightened down, it can cause a multitude of
problems from internal misalignment to motor air gap problems

2006-12-07 ©SKF Slide 62 [Code]


SKF [Organisation]
Soft Foot

2006-12-07 ©SKF Slide 63 [Code]


SKF [Organisation]
Soft foot

• A soft foot will typically produce a


marked increase or decrease in
amplitude when loosened

• Can often be corrected through


shimming while the machine is still
operating

2006-12-07 ©SKF Slide 64 [Code]


SKF [Organisation]
The need for signal processing

• Generally, low frequency vibration from unbalance or misalignment


masks the low amplitude bearing vibration signals and the bearing
faults are not detected
• Repetitious gearmesh and bearing faults typically emit low energy
vibration signals in the lower frequencies, especially in the early
states of failure. However, because these faults emit impact signals
that are highly pulse shaped and of very short duration, they
generate harmonics out to very high frequencies

2006-12-07 ©SKF Slide 65 [Code]


SKF [Organisation]
Typical Bearing Failure Rate

Detection by
Lubricant Analysis
Detection by
Acoustic Emissions
Detection by Listen
and Feel

Detection by Vibration

2006-12-07 ©SKF Slide 66 [Code]


SKF [Organisation]
Signal processing methods

• Enveloped Acceleration
• SEE (spectrum emitted energy)
• HFD (high frequency detection)

overall vibration signal (including bearing fault signal)

bearing fault signal

2006-12-07 ©SKF Slide 67 [Code]


SKF [Organisation]
Enveloped acceleration process

Band Pass Filter is specified


according to defect harmonic
frequencies of interest

defect fundamental
frequency
low frequency events filtered out, high resulting enveloped signal,
frequency defect harmonics emphasized measured in gE
due to low signal to noise ratio, these high
frequency harmonics are then summed and fundamental
folded back to the defect’s fundamental frequency frequency
harmonics

2006-12-07 ©SKF Slide 68 [Code]


SKF [Organisation]
Bearing fault concept…

Defect Force Response

2006-12-07 ©SKF Slide 69 [Code]


SKF [Organisation]
Bearing fault concept

4.3x

4.3x4.3x4.3x 4.3x 4.3x


4.3x

Filter
1x 1x 4.3x8.6x12.9x17.2x 104.3x
108.6x
112.9x
~10x

Rectify Smooth 4.3x 4.3x 4.3x


4.3x
12.9x17.2x 104.3x
108.6x
112.9x

4.3x 4.3x
4.3x
4.3x8.6x12.9x17.2x 104.3x
108.6x
112.9x

4.3x8.6x12.9x17.2x 104.3x
108.6x
112.9x

2006-12-07 ©SKF Slide 70 [Code]


SKF [Organisation]
Selecting the enveloping filter…

The acceleration envelope process groups energy related to the bearing defect
and excludes all others. Bandpass filter
5 Hz - 100 Hz

Accelerometer 50 Hz - 1 kHz Envelope


Detector
500 Hz - 10 kHz

5 kHz - 40 kHz FFT Spectrum

Felt Rolls, Bearings Bearings Gears

Filter #1 Filter #2 Filter #3 Filter #4


Frequency - Hz

2006-12-07 ©SKF Slide 71 [Code]


SKF [Organisation]
Selecting the enveloping filter

Filter Frequency Speed Range Analyzing


Band Range
1 5 - 100 Hz 0 - 50 rpm 0 – 10 Hz

2 50 - 1,000 Hz 25 - 500 rpm 0 – 100 Hz

3 500 - 10,000 Hz 250 - 5,000 rpm 0 – 1,000 Hz

4 5,000 - 40,000 Hz 2,500 - … rpm 0 – 10,000 Hz

Note: Detection is peak to peak

2006-12-07 ©SKF Slide 72 [Code]


SKF [Organisation]
Rubbing…

2006-12-07 ©SKF Slide 73 [Code]


SKF [Organisation]
Rubbing

2006-12-07 ©SKF Slide 74 [Code]


SKF [Organisation]
Oil Whirl

2006-12-07 ©SKF Slide 75 [Code]


SKF [Organisation]
Oil Whip

2006-12-07 ©SKF Slide 76 [Code]


SKF [Organisation]
Electrical Motor Cross Sectional View…

2006-12-07 ©SKF Slide 77 [Code]


SKF [Organisation]
Electrical Motor – Working Principle…

2006-12-07 ©SKF Slide 78 [Code]


SKF [Organisation]
AC Motors – Normal Vibration

2006-12-07 ©SKF Slide 79 [Code]


SKF [Organisation]
AC Motors – Broken / Cracked Rotor

2006-12-07 ©SKF Slide 80 [Code]


SKF [Organisation]
AC Motors – Eccentric Rotor

2006-12-07 ©SKF Slide 81 [Code]


SKF [Organisation]
AC Motors – Loose / Open Rotor

2006-12-07 ©SKF Slide 82 [Code]


SKF [Organisation]
AC Motors – Loose Stator Coils

2006-12-07 ©SKF Slide 83 [Code]


SKF [Organisation]
AC Motors – Phase Problems

2006-12-07 ©SKF Slide 84 [Code]


SKF [Organisation]
DC Motors

2006-12-07 ©SKF Slide 85 [Code]


SKF [Organisation]
DC Motors – Current Passing through bearings

2006-12-07 ©SKF Slide 86 [Code]


SKF [Organisation]
DC Motors – Faulty Comparator Card

2006-12-07 ©SKF Slide 87 [Code]


SKF [Organisation]
DC Motors – Faulty Carbon Firing

2006-12-07 ©SKF Slide 88 [Code]


SKF [Organisation]
Plain Bearing Clearances…

2006-12-07 ©SKF Slide 89 [Code]


SKF [Organisation]
Plain Bearing Problems…

2006-12-07 ©SKF Slide 90 [Code]


SKF [Organisation]
Gear Problems…

2006-12-07 ©SKF Slide 91 [Code]


SKF [Organisation]
Gear Meshing Frequency….

2006-12-07 ©SKF Slide 92 [Code]


SKF [Organisation]
Gear Phase Related Problems…

• Gear Assembly Phase Frequency (GAPF) can result in Fractional Gear


Mesh Frequencies (if NA>1).
• It literally means (TG/NA) gear teeth will contact (TP/NA) pinion teeth
and will generate NA wear patterns, where NA in a given tooth
combination equals the product of prime factors common to the
number of teeth on the gear and pinion (NA = Assembly Phase Factor).
• GAPF (or harmonics) can show up right from the beginning if there
were manufacturing problems.
• Also, its sudden appearance in a periodic survey spectrum can
indicate damage if contaminate particles pass through the mesh,
resulting in damage to the teeth in mesh at the time of ingestion just
as they enter and leave meshing or that gears have been reoriented.

2006-12-07 ©SKF Slide 93 [Code]


SKF [Organisation]
Gears – Phase assembly problems

2006-12-07 ©SKF Slide 94 [Code]


SKF [Organisation]
Gear – Broken Teeth

2006-12-07 ©SKF Slide 95 [Code]


SKF [Organisation]
Gear - Eccentricity

2006-12-07 ©SKF Slide 96 [Code]


SKF [Organisation]
Gear – Excessive loads

2006-12-07 ©SKF Slide 97 [Code]


SKF [Organisation]
Gear – Hunting tooth

2006-12-07 ©SKF Slide 98 [Code]


SKF [Organisation]
Gear – Loose bearing fit

2006-12-07 ©SKF Slide 99 [Code]


SKF [Organisation]
Gear – Teeth Misalignment

2006-12-07 ©SKF Slide 100 [Code]


SKF [Organisation]
Belt Alignment – An practical Approach!
Is this the way!!

2006-12-07 ©SKF Slide 101 [Code]


SKF [Organisation]
Belt Related Problems - Basics

2006-12-07 ©SKF Slide 102 [Code]


SKF [Organisation]
Belt Related Problems…

2006-12-07 ©SKF Slide 103 [Code]


SKF [Organisation]
Eccentric Pulley…

2006-12-07 ©SKF Slide 104 [Code]


SKF [Organisation]
Belt – Eccentric Pulley

2006-12-07 ©SKF Slide 105 [Code]


SKF [Organisation]
Belt Angular Misalignment – in Pulley…

2006-12-07 ©SKF Slide 106 [Code]


SKF [Organisation]
Belt Vertical Misalignment – in Pulley…

2006-12-07 ©SKF Slide 107 [Code]


SKF [Organisation]
Belt offset Misalignment – in Pulley…

2006-12-07 ©SKF Slide 108 [Code]


SKF [Organisation]
Belt – Misalignment

2006-12-07 ©SKF Slide 109 [Code]


SKF [Organisation]
Belt – Resonance

2006-12-07 ©SKF Slide 110 [Code]


SKF [Organisation]
Proper Belt Alignment Technique…

2006-12-07 ©SKF Slide 111 [Code]


SKF [Organisation]
Cavitation

2006-12-07 ©SKF Slide 112 [Code]


SKF [Organisation]
Flow Turbulence

2006-12-07 ©SKF Slide 113 [Code]


SKF [Organisation]
Hydraulic / Aerodynamic forces

2006-12-07 ©SKF Slide 114 [Code]


SKF [Organisation]
Resonance…

• A condition where a structure vibrates at very large


amplitudes for a given force level
• Not a source of vibration, an amplifier of vibration
• Most resonance conditions are from a rotating or periodic
force produced inside the machine
• Occurs when a machine operates at a speed near one of
its natural frequencies

2006-12-07 ©SKF Slide 115 [Code]


SKF [Organisation]
Bump Test…

2006-12-07 ©SKF Slide 116 [Code]


SKF [Organisation]
Resonance Modes…

2006-12-07 ©SKF Slide 117 [Code]


SKF [Organisation]
Resonance Modes…

2006-12-07 ©SKF Slide 118 [Code]


SKF [Organisation]
Resonance Modes…

2006-12-07 ©SKF Slide 119 [Code]


SKF [Organisation]
Resonance Modes…

2006-12-07 ©SKF Slide 120 [Code]


SKF [Organisation]
Resonance…concepts

• Mass
• Stiffness
• Damping
Machine designers design
machinery components
so that the machine
operates at a speed 20-
30% higher/lower than
the resonant frequencies

2006-12-07 ©SKF Slide 121 [Code]


SKF [Organisation]
Correcting resonant conditions

• Bracing or Stiffening
• Changing the speed of the machine
• Damping treatments
• Reduce or eliminate the vibration source

2006-12-07 ©SKF Slide 122 [Code]


SKF [Organisation]
ISO 10816-1 (horizontal shaft)

2006-12-07 ©SKF Slide 123 [Code]


SKF [Organisation]
ISO 10816-1 (overhung – horizontal shaft )

2006-12-07 ©SKF Slide 124 [Code]


SKF [Organisation]
ISO 10816-1 (vertical shaft )

2006-12-07 ©SKF Slide 125 [Code]


SKF [Organisation]
Quick review

QUESTIONS ?