Height Sensor
Weir
Channel
Section
Volumetri
c Tank
Figure 10-1: HM 150 Flow weir demonstration
h0
h
h1
z
b
The volumetric flow rate can be derived from the weir width b and the weir head z. The width b is constant.
b=6.0 cm. The weir head z, is measured indirectly. The height h of the water level is measured given the
constants: h0 = 4.7 cm, h1= 5.0 cm. The weir head z is calculated a follows, z = h0 + h1- h
2
𝑄"#$%"& = 𝐶𝑏𝑧 2𝑔𝑧
3
The actual volumetric flow rate Q can be determined with the aid of the volumetric tank of the HM 150
using stopwatch. It is advisable to measure the filling time t for 10 liters. A good volume display is obtained
in the scale range between 20 and 30 liters.
10.5. Materials/Equipment
HM 150.03 Flow Weir Accessories
1 unit HM 150.0 Basic Hydraulic Bench
HM 150.0 Basic Hydraulic Bench Accessories
1 Set Timer
1 Set Thermometer
Power and Water Supply Supplies
10.6. Procedures
Performing of the Activity
1. Check the following: Water supply from the main source
2. Check whether the equipment is free from any kind of obstruction that can affect your operation.
3. After conducting preliminary check-up, start performing if everything is in order.
4. Fill the HM 150 with water and establish the power supply.
5. Attach the rectangular-profile for the first and second trial. Record the required data for calculation
and observation.
6. After performing and getting all the data, turn off machine and disconnect the plug from the
electricity source.
7. Clean the equipment.
10.7. Activity Report
Course Code:
Course Title: Activity No.:
Group No.: Section:
Group Members: Date Performed:
Date Submitted:
Instructor:
10.7.2. Computation
10.7.3. Conclusion/s