Question

Which of the following connections is best suited for 3-phase, 4-wire service ?
In a three-phase Y-Y transformer connection, neutral is provided for the
The number of single phase transformers required for V − V bank of transformers is ...........
The utilization factor for transformers in open-delta connection is__________
A 3-phase star-delta transformer has primary to secondary turns ratio per phase of 5. For a primary line current of 10 A, the secondary line cu

For supplying a balanced 3-phase load of 40-kVA,rating of each transformer in V − V bank should be nearly ......... kVA
When a closed − Δ bank is converted into an open − Δ bank, each of the two remaining transformers
supplies ......... percent of the original load
A bank of three identical single phase 250 kVA, 11 kV/230 V transformer is used to provide 400 V low tension supply from a 11 kV, 3-phase s
effective kVA rating of the bank will be
A T − T connection has higher ratio of utilization that a V − V connection only when
The biggest advantage of T - T connection over the V - V connection for 3-phase power transformation is that it provides
Out of the following given choices for poly phase transformer connections which one will you select for three-to-two phase conversion ?
The symbol Yd11 represents a 3-phase transformer with HV line phasor
Why tertiary winding is used in transformers?
Tertiary winding is generally _________
Tertiary winding allows the flow of __________.
Simple phase equivalent circuit of three winding transformer can be shown as ____________.
The reasons for tapping transformers with large turns ration on HV side are
In tap changing transformers, how tap changing is achieved?
In tap changing transformers, tapping is done at _________________.
For achieving large voltage regulation tapping should be done at _____________.
When the supply frequency of a three phase induction motor is increased, then its synchronous speed is
A 3-phase 440 V, 50 Hz induction motor has 4% slip. The frequency of rotor current will be
When the rotor of 3 phase induction motor is blocked, the value of slip will be
A double squirrel-cage induction motor has
If any two phases for a 3-phase induction motor are interchanged then
if 𝑅_2 and 𝑋_2 are the per phase standstill rotor resistance and reactance of an induction motor, then the condition for maximum running t
An induction motor is analogous to
The relative speed between the magnetic fields of stator and rotor of an induction motor under steady state operation is ___________
The rotor power output of a 3-phase induction motor is 30 KW and corresponding slip is 4%. The rotor copper loss will be
What is the ratio of rotor input power to rotor copper loss in an induction motor?
An 8 pole, three phase induction motor is supplied from 50 Hz, AC supply. On full load, the frequency of induced EMF in the rotor is 2 Hz. Th
slip and the corresponding speed.
The magnetising current drawn by a 3-phase induction motor is about ……….. of full-load stator current.

The maximum torque of a 3-phase induction motor under running conditions is


A 3-phase induction motor is running at 2% slip. If the input to rotor is 1000 W, then mechanical power developed by the motor is

In three-phase induction motors sometimes copper bars are placed deep in the rotor to
If V is the supply voltage, then the torque developed in an induction motor varies as
A 3-phase Induction motor connected in star takes 20 A from the supply mains. When connected in Delta, the motor shall take from the supp
of ___________
In a double squirrel cage induction motor, the outer cage winding has
If Ns is the synchronous speed, Nr is the rotor speed and s is the slip, then the speed of stator field with respect to rotor structure is _________
In a 3-phase induction motor, maximum torque of 100 N-m occurs at a slip of 10%. The torque at slip of 5% would be
The starting current of a delta-connected 3 phase induction motor at rated voltage is 5 times the full-load current and the slip at full-load is 5
current is negligible. If an auto-transformer starter is used to limit the starting current from mains to 2 times the full-load current, the starting
percentage of the full-load torque is ___________.
The X-axis and Y-axis in a circle diagram reprasents
The speed control method of rotor rheostat control is used for
A 15kW, 1440 V, 6 pole, delta connected induction motorgave the following test results No-load test : 440V, 10 A, 280W Blocked rotor tes
1600 W The dc resistance of stator winding is 0.2 Ω per phase.Assume a factor of 1.2 due to skin effect.The value of magnetizing reactance

A starting torque of 100 Nm is developed in a three phase squirrel cage induction motor by an autotransformer starter with a tapping of 40%
autotransformer is changed to 80%, then the starting torque would be________.
DOL starting of induction motor is usally restricted to
An induction motor can run at synchronous speed when
As compared to DOL starting star-delta starting method should have
No-load test of three phase induction motor used to determine
The rotor of slip ring induction motor is connected to an ac supply, whereas its stator winding is shorted circuited. If rotating magnetic field p
winding rotates clockwise. The direction in which rotor must revolve is _________.
The most common application of three phase induction generator can be in a
In a three phase squirrel cage induction motor , applied voltage is reduced to x times its rated value. Then, its starting line current from main
torque by autotransformer starting would reduce respectively from their corresponding direct switching values by a factor of ________.
When the supply voltage to a three phase squirrel cage induction motor reduced by 20 % , the maximum torque will be decreased by________
In the circle diagram for induction motor, the diameter of the circle represents
The reactance of rotor circuit of three phase induction motor is maximum at
A star-delta starter is equivalent to an autotransformer starter with a tapping of
The following tests are conducted on three phase induction motor 1. No-load test 2. Blocked rotor test 3. stator resistance test the c
diagram of three phase induction motor can be drawn with the help of
During blocked rotor test of three phase induction motor, the power input to three phase induction motor has to supply
Crawling in an induction motor is due to
An increase in number of poles in a three phase induction motor results in